HomeMy WebLinkAbout2025-12-16 - PC - Special Meeting CITY OF HERMOSA BEACH PLANNING COMMISSION Special Meeting Agenda Call and Notice of Special Meeting: The Chairperson of the City of Hermosa Beach Planning Commission has called a Special Meeting to consider and take action on only those matters set forth on the agenda. Tuesday, December 16, 2025 5:00 PM Council Chambers 1315 Valley Drive Hermosa Beach, CA 90254 Planning Commissioners Kate Hirsh, Chairperson Stephen Izant, Vice Chairperson Michael Flaherty, Commissioner Peter Hoffman, Commissioner Greg McNally, Commissioner Alison Becker, Community Development Director AMERICANS WITH DISABILITIES ACT OF 1990 To comply with the Americans with Disabilities Act of 1990, Assistive Listening Devices (ALD) are available for check out at the meeting. If you require special assistance to participate in this meeting, you must call or submit your request in writing to the Office of the City Clerk at (310) 318-0204 or at cityclerk@hermosabeach.gov at least 48 hours before the meeting. PARTICIPATION AND VIEWING OPTIONS Hermosa Beach Planning Commission meetings are open to the public and are being held in person in the City Hall Council Chambers located at 1315 Valley Drive, Hermosa Beach, CA 90254. Public comment is only guaranteed to be taken in person at City Hall during the meeting or prior to the meeting by submitting an Comment fo an item on the agenda. As a courtesy only, the public may view and participate on action items listed on the agenda via the following: Zoom: https://us02web.zoom.us/j/82539742028?pwd=OUNTRDNvd2I6TzBpTDIjc2x6bGFwd z09 • Phone: Toll Free: (833) 548 0276; Meeting ID: 825 3974 2028, then #; Passcode: 207860• eComment: Submit an eComment by 3:00 p.m. on the meeting date. • Supplemental Email: Supplemental emails are available for agenda items only and must be sent to planning@hermosabeach.gov. Supplemental emails should indicate the agenda item and meeting date in the subject line and must be received no later than three (3) hours before the meeting start time. Emails received after the deadline but before the meeting ends will be posted to the agenda the next business day. Writings distributed to all, or majority of all, of the Commission after the agenda has been posted shall be available for inspection at the Community Development Department located at 1315 Valley Drive, Hermosa Beach, CA 90254 during regular business hours. • Please be advised that while the City will endeavor to ensure these remote participation methods are available, the City does not guarantee that they will be technically feasible or work all the time. Further, the City reserves the right to terminate these remote participation methods (subject to Brown Act restrictions) at any time and for whatever reason. Please attend in person or by submitting an eComment to ensure your public participation. Similarly, as a courtesy, the City will also plan to broadcast the meeting via the following listed mediums. However, these are done as a courtesy only and not guaranteed to be technically feasible. Thus, in order to guarantee live time viewing and/or public participation, members of the public shall attend in Council Chambers. Cable TV: Spectrum Channel 8 and Frontier Channel 31 in Hermosa Beach• YouTube: https://www.youtube.com/c/CityofHermosaBeach90254• Live Stream: www.hermosabeach.gov/agenda • Cablecast App: Available on supported devices and smart TVs• If you experience technical difficulties while viewing a meeting on any of our digital platforms, please try another viewing option. View the Commission staff reports and attachments at www.hermosabeach.gov/agenda. Page 2 of 324 Pages PLEASE TAKE NOTICE that the Chairperson of the Planning Commission has called a Special Meeting to take place at 5:00 p.m. on Tuesday, December 16, 2025 to consider and take action on those matters set forth on the agenda below. 1.CALL TO ORDER 2.PLEDGE OF ALLEGIANCE 3.ROLL CALL 4.STAFF ITEMS 4.a Rotation of Planning Commission Chairperson and Vice Chairperson - 25-CDD-180 7 (Planning Manager Alexis Oropeza) Recommendation: In accordance with past direction and practice, the Chairperson and Vice Chairperson of the Planning Commission rotate every nine months. The current Chairperson, Kate Hirsh, and the current Vice Chairperson, Stephen Izant, served from March 1, 2025, through November 30, 2025. On December 16, 2025, the Chairperson position will rotate to Stephen Izant and the Vice Chairperson will rotate to Michael Flaherty for the term running from December 16, 2025 through August 31, 2026. 5.APPROVAL OF AGENDA This is the time for Planning Commission to discuss any changes to the order of agenda items. 6.PUBLIC COMMENT This is the time for members of the public to address the Planning Commission on any item(s) listed on the special meeting agenda only. Public comments are limited to 3 minutes per speaker. 7.CONSENT CALENDAR The following matters will be acted upon collectively with a single motion and vote to approve with the majority consent of the Planning Commission. Commissioners may orally register a negative vote on any Consent Calendar item without pulling the item for separate consideration before the vote on the Consent Calendar. There will be no separate discussion of these items unless a Commissioner removes an item from the Consent Calendar, either under Approval of the Agenda or under this item before the vote on the Consent Calendar. Items removed for separate discussion will be provided a separate public comment period. Recommendation: To approve the consent calendar. 7.a ACTION MINUTES OF THE PLANNING COMMISSION SPECIAL AND REGULAR MEETINGS OF NOVEMBER 18, 2025 - 25-CDD-185 8 Page 3 of 324 (Planning Manager Alexis Oropeza) Recommendation: Staff recommend Planning Commission receive and file the action minutes of the Planning Commission special and regular meetings of November 18, 2025 7.b LOCATION: 620 9TH STREET - 25-CDD-172 21 TWO YEAR TIME EXTENSION REQUEST FOR A CONDITIONAL USE PERMIT (CUP 23-10), PRECISE DEVELOPMENT PLAN (PDP 23-07), AND VESTING TENTATIVE PARCEL MAP (VTPM NO 84231) FOR A 3- UNIT ATTACHED CONDOMINIUM PROJECT AT 620 9TH STREET IN THE TWO-FAMILY RESIDENTIAL (R-2) ZONE. CEQA: Determine that the project remains categorically exempt from the California Environmental Quality Act pursuant to the previously approved Class 3 Exemption for New Construction as defined in Section 15303(b) of the CEQA guidelines. Recommendation: Staff recommends that the Planning Commission: Determine the project remains categorically exempt from the California Environmental Quality Act (CEQA) pursuant to the previously approved Class 3 Exemption for New Construction as defined in Section 15303(b) of the CEQA guidelines and; 1. Adopt by Minute Order a two-year time extension for Conditional Use Permit 23-10, Precise Development Plan 23-07, and Vesting Tentative Parcel Map No 84231 for a 3-unit attached condominium project. 2. 8.PUBLIC HEARINGS 8.a LOCATION: 1054 AVIATION BOULEVARD - 25-CDD-171 43 PRECISE DEVELOPMENT PLAN (PDP25-01) FOR NEW 6,487- SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING, AT 1054 AVIATION BOULEVARD, LOCATED WITHIN THE GENERAL COMMERCIAL ZONE (C-3). CEQA: Determine the project is exempt from the California Environmental Quality Act. (Assistant Planner Johnny Case) Recommendation: Staff recommends the Planning Commission: Determine the project is categorically exempt from the California Environmental Quality Act (CEQA); and 1. Adopt a Resolution approving a Precise Development Plan (PDP25-01) for a new 6,487 square-foot multi-tenant commercial building located at 1054 Aviation Boulevard, subject to conditions of approval (Attachment 1). 2. Page 4 of 324 8.b LOCATION: 901 HERMOSA AVENUE - 25-CDD-183 86 A PRECISE DEVELOPMENT PLAN AND LOT LINE ADJUSTMENT TO REMODEL AND ADD A THIRD STORY TO AN EXISTING COMMERCIAL BUILDING AT 901 HERMOSA AVENUE IN THE DOWNTOWN COMMERCIAL ZONE AND COASTAL ZONE CEQA: Determine the project is exempt from the California Environmental Quality Act. (Contract Planner Kaneca Pompey) Recommendation: Staff recommends the Planning Commission: Determine the project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to section 15301, class 1 and section 15305, class 5 of the CEQA guidelines. 1. Adopt a Resolution approving Precise Development Plan (PDP23-04) and Lot Line Adjustment (LLA 23-03) to remodel and add to an existing two-story commercial building that measures 12,012 square feet located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot, subject to conditions of approval (Attachment 1), including approval of a Coastal Development Permit by the California Coastal Commission. 2. 8.c LOCATION: CITYWIDE - 25-CDD-168 291 A ZONE TEXT AMENDMENT (TA25-03) AMENDING VARIOUS SECTIONS OF TITLE 17 OF THE HERMOSA BEACH MUNICIPAL CODE SECTION PERTAINING TO APPEAL PERIODS AND THE TRANSMISSION OF PLANNING COMMISSION DECISIONS TO CITY COUNCIL CEQA: The project qualified for a Categorical Exemption per Section 15061(b)(3) of the California Environmental Quality Act Guidelines. (Planning Manager Alexis Oropeza) Recommendation: Staff recommends the Planning Commission: Find the adoption of the proposed ordinance exempt from review under the California Environmental Quality Act (“CEQA”) and 1. Adopt a Resolution (Attachment 1) recommending that the City Council adopt the proposed ordinance approving Zone Text Amendment 25-03. 2. 8.d LOCATION: CITYWIDE - 25-CDD-175 308 A ZONE TEXT AMENDMENT (TA 25-04) AMENDING HERMOSA BEACH MUNICIPAL CODE SECTION 17.08.020(D) PERTAINING TO HOME OCCUPATIONS Page 5 of 324 CEQA: The project is exempt from the CEQA per section 15061(b)(3) of the California Environmental Quality Act Guidelines. (Community Development Director Alison Becker) Recommendation: Staff recommends that the Planning Commission: Find that the adoption of the proposed ordinance exempt from review under the California Environmental Quality Act (“CEQA”); and 1. Adopt a Resolution (Attachment 1) recommending that the City Council adopt the proposed ordinance approving Zone Text Amendment 25-04 amending Section 17.08.020(D) pertaining to Home Occupations (Citywide). 2. 9.COMMUNITY DEVELOPMENT DIRECTOR REPORT 322 10.COMMISSIONER ITEMS Requests from Commissioners for possible future agenda items. No discussion or debate of these requests shall be undertaken; the sole action is whether to schedule the item for consideration on a future agenda. No public comment will be taken. Commissioners should consider the city’s work plan when considering new items. 10.a PLANNING COMMISSION COMMENTS Planning Commission members may briefly respond to public comments, may ask a question for clarification, or make a brief announcement or report on his or her own activities or meetings attended. 11.FUTURE AGENDA ITEMS Requests from the Planning Commission for possible future agenda items and questions from Planning Commission members regarding the status of future agenda items. No discussion or debate of these requests shall be undertaken; the sole action is whether to schedule the item for consideration on a future agenda. No public comment will be taken. Planning Commission members should consider the city's work plan when considering new items. 11.a PLANNING COMMISSION TENTATIVE FUTURE AGENDA - 25-CDD- 179 323 (Planning Manager Alexis Oropeza) Recommendation: Staff recommend Planning Commission receive and file the tentative future agenda for the Planning Commission regular meeting of January 20, 2026. 12.ADJOURNMENT Page 6 of 324 City of Hermosa Beach | Page 1 of 1 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-180 Honorable Chair and Members of the Hermosa Beach Planning Commission Rotation of Planning Commission Chairperson and Vice Chairperson (Planning Manager Alexis Oropeza) Recommended Action: In accordance with past direction and practice, the Chairperson and Vice Chairperson of the Planning Commission rotate every nine months. The current Chairperson, Kate Hirsh, and the current Vice Chairperson, Stephen Izant, served from March 1, 2025, through November 30, 2025. On December 16, 2025, the Chairperson position will rotate to Stephen Izant and the Vice Chairperson will rotate to Michael Flaherty for the term running from December 16, 2025 through August 31, 2026. Respectfully Submitted by: Alexis Oropeza, Planning Manager Approved: Alison Becker, AICP, Community Development Director Page 7 of 324 City of Hermosa Beach | Page 1 of 1 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-185 Honorable Chair and Members of the Hermosa Beach Planning Commission ACTION MINUTES OF THE PLANNING COMMISSION SPECIAL AND REGULAR MEETINGS OF NOVEMBER 18, 2025 (Planning Manager Alexis Oropeza) Recommended Action: Staff recommend Planning Commission receive and file the action minutes of the Planning Commission special and regular meetings of November 18, 2025 Attachments: 1. Planning Commission Action Minutes Special Meeting of November 18, 2025 2. Planning Commission Action Minutes Regular Meeting of November 18, 2025 Respectfully Submitted by: Alexis Oropeza, Planning Manager Approved: Alison Becker, Community Development Director Page 8 of 324 1 CITY OF HERMOSA BEACH Planning Commission Special Meeting Minutes November 18, 2025 5:00 p.m. Council Chambers 1315 Valley Drive Hermosa Beach, CA 90254 Members Present: Chairperson Kate Hirsh, Commissioner Greg McNally, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty Staff Present: Community Development Director Alison Becker, Associate Planner Jake Whitney, Assistant Planner DeDe Tran, Assistant Planner Johnny Case, Interim City Attorney Sarah Locklin _____________________________________________________________________ 1. CALL TO ORDER Chairperson Hirsh called the meeting to order at 5:09 p.m. 2. ROLL CALL Associate Planner Jake Whitney announced a quorum. 3. APPROVAL OF AGENDA Moved by: Chairperson Kate Hirsh Seconded by: Vice Chairperson Stephen Izant To approve the order of the agenda. Page 9 of 324 2 Ayes (5): Chairperson Kate Hirsh, Commissioner Greg McNally, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, and Commissioner Michael Flaherty Motion Carried 4. PUBLIC COMMENT Public Comment provided by: Eric Horn (In-Person) Tony Higgins (Virtual) 5. STAFF ITEMS 5.a 6TH CYCLE HOUSING ELEMENT IMPLEMENTATION STATUS REPORT - 25-CDD-167 Community Development Director Alison Becker provided a presentation Interim City Attorney Sarah Locklin provided a presentation Planning Commissioners asked questions and received answers from staff and Interim City Attorney Sarah Locklin. Public Comment provided by: John David (In-Person) David Grethen (In-Person) Tony Higgins (Virtual) Laura Pena (Virtual) Kristen (Last name not provided) (Virtual) Moved by: Commissioner Peter Hoffman Seconded by: Vice Chairperson Stephen Izant Staff recommends Planning Commission: 1. Receive and file staff presentation. Ayes (5): Chairperson Kate Hirsh, Commissioner Greg McNally, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, and Commissioner Michael Flaherty Motion Carried 5.b DISCUSSION OF LAND VALUE RECAPTURE ORDINANCE A PROGRAM OF THE 2021-2029 CERTIFIED HOUSING ELEMENT - 25- CDD-077 Page 10 of 324 3 Community Development Director Alison Becker provided a presentation Planning Commissioners asked questions and received answers from staff and Interim City Attorney Sarah Locklin Public Comment was provided by: John David (In-Person) John Burry (In-Person) David Grethen (In-Person) Laura Pena (Virtual) Nancy Schwappach (Virtual) Planning Commissioners deliberated and asked further questions of staff and Interim City Attorney Sarah Locklin Planning Commissioners recommended City Council to: 1. Move Staff Recommendation B: exempt smaller lots with a minimum density of 1 to 2 units from any dollar amount LVR fee. 2. Move Staff Recommendation D: Direct staff to explore zoning regulations that encourage development of residential units on “small lots” 3. Move Staff Recommendation E: A temporary LVR fee reduction for lots with a density of 3-4 units for 24 months to $40 dollars per square foot. Moved by: Vice Chairperson Stephen Izant Seconded by: Commissioner Peter Hoffman Staff recommends the Planning Commission: 1. Receive a staff report and solicit public input; and 2. Provide a recommendation to City Council. Ayes (5): Chairperson Kate Hirsh, Commissioner Greg McNally, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, and Commissioner Michael Flaherty Motion Carried 6. ADJOURNMENT The meeting was adjourned at 7:42 p.m. Page 11 of 324 4 Page 12 of 324 1 CITY OF HERMOSA BEACH PLANNING COMMISSION MEETING MINUTES November 18, 2025 6:00 p.m. Council Chambers 1315 Valley Drive Hermosa Beach, CA 90254 Members Present: Chairperson Kate Hirsh, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, Commissioner McNally Staff Present: Associate Planner Jake Whitney, Assistant Planner Johnny Case, Community Development Director Alison Becker, Assistant Planner DeDe Tran, Contract Planner Kaneca Pompey, Interim City Attorney Sarah Locklin _____________________________________________________________________ 1. CALL TO ORDER Chairperson Hirsh called the meeting to order at 7:55 p.m. 2. PLEDGE OF ALLEGIANCE The Pledge of Allegiance was led by Vice Chairperson Izant. 3. ROLL CALL Associate Planner Jake Whitney announced a quorum. 4. APPROVAL OF AGENDA This is the time for Planning Commission to discuss any changes to the order of agenda items. Item 7d moved first on the agenda. Page 13 of 324 2 Commissioner Hoffman motioned to approve the consent calendar, Seconded by Vice Chairperson Izant. Voice vote was taken. Motion carried unanimously. 5. PUBLIC COMMENT This is the time for members of the public to address the Planning Commission on any items within the Commission's jurisdiction and on items where public comment will not be taken. The public is invited to attend and provide public comment. Public comments are limited to three minutes per speaker from those present in the Council Chambers and via the remote participation option(s) listed on the agenda. This time allotment may be modified due to time constraints at the discretion of the Chair. No action will be taken on matters raised in oral and written communications, except that the Planning Commission may take action to schedule issues raised during public comment for a future agenda. Speakers with comments regarding departmental operations are encouraged to submit those comments directly to the Community Development Director or the Office of the City Manager. In-Person public comments:  No public comments provided. 6. CONSENT CALENDAR The following matters will be acted upon collectively with a single motion and vote to approve with the majority consent of the Planning Commission. Commissioners may orally register a negative vote on any Consent Calendar item without pulling the item for separate consideration before the vote on the Consent Calendar. There will be no separate discussion of these items unless a Commissioner removes an item from the Consent Calendar, either under Approval of the Agenda or under this item before the vote on the Consent Calendar. Items removed for separate discussion will be provided a separate public comment period. Moved by: Chairperson Kate Hirsh Seconded by: Vice Chairperson Stephen Izant To approve the consent calendar. 6.a ACTION MINUTES OF THE PLANNING COMMISSION REGULAR MEETING OF OCTOBER 21, 2025 - 25-CDD-161 (Planning Manager Alexis Oropeza) Staff recommend Planning Commission receive and file the action minutes of the Planning Commission regular meeting of October 21, 2025. 7. PUBLIC HEARING 7.a PRECISE DEVELOPMENT PLAN (PDP 25-02), CONDITIONAL USE PERMIT (CUP 25-06), AND VESTING TENTATIVE PARCEL MAP NO. 84794 FOR A NEW TWO-UNIT RESIDENTIAL CONDOMINIUM AT 1035 Page 14 of 324 3 LOMA DRIVE, WITHIN THE MULTIPLE-FAMILY (R-3) ZONE - 25-CDD- 150 CEQA: Determine the project is categorically exempt from the California Environmental Quality Act. (Assistant Planner Johnny Case) Assistant Planner Johnny Case provided a presentation. Planning Commissioners asked questions and received answers from staff and Interim City Attorney Sarah Locklin. Applicant's representative Stacy Straus spoke. Public Comment was provided by:  Olivier Enders (in-person)  Francesca Enders (in-person)  Rachel Enders Clark (virtual) Applicant's representative Brandon Straus spoke. Public Comment was provided by:  Nancy Scwappach Planning Commissioners deliberated. Moved by: Vice Chairperson Stephen Izant Seconded by: Commissioner Peter Hoffman Staff recommends that the Planning Commission: 1. Determine the project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to a Class 3 categorical exemption, as defined in section 15303 of the CEQA Guidelines for new construction; and 2. Adopt a Resolution (Attachment 1) approving Conditional Use Permit (CUP 25-06), Precise Development Plan (25-02) and Vesting Tentative Parcel Map No. 84794 allowing two new residential condominium buildings in the Multiple-Family Residential zone (R-3) subject to conditions. Ayes (5): Chairperson Kate Hirsh, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, and Commissioner McNally Motion Carried Page 15 of 324 4 7.b PRECISE DEVELOPMENT PLANS (PDP 25-07 and PDP 25-08), CONDITIONAL USE PERMITS (CUP 25-09 and CUP 25-10), AND VESTING TENTATIVE PARCEL MAP NO. 84793 FOR TWO NEW TWO- UNIT RESIDENTIAL CONDOMINIUMS AT 714 AND 722 LOMA DRIVE IN THE TWO-FAMILY RESIDENTIAL (R-2) ZONE - 25-CDD-162 CEQA: Determine that the projects are categorically exempt from the California Environmental Quality Act (CEQA) (Assistant Planner DeDe Tran) Commissioner Hoffman recused himself from the item. Assistant Planner DeDe Tran provided a presentation. Applicant's architect Alex Ioda provided a presentation. Public Comment was provided by:  Larry Nakamura Planning Commissioners deliberated. Moved by: Commissioner Michael Flaherty Seconded by: Vice Chairperson Stephen Izant Staff recommends that the Planning Commission: 1. Determine the projects are categorically exempt from the California Environmental Quality Act (CEQA) pursuant to a Class 3 categorical exemption, as defined in section 15303 of the CEQA Guidelines for new construction; and 2. Adopt Resolution (Attachment 1) approving Conditional Use Permits (CUP25-09 & CUP25-10), Precise Development Plans (PDP25-07 & PDP25-08), and Vesting Tentative Parcel Map No. 84793 allowing two new two-unit residential condominium buildings in the Two-Family Residential Zone (R-2) subject to conditions. Ayes (4): Chairperson Kate Hirsh, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, and Commissioner McNally Recused (1): Commissioner Peter Hoffman Motion Carried 7.c CONVEX SLOPE DETERMINATION (CSD 25-01) AND PRECISE DEVELOPMENT PLAN (PDP 25-04) FOR A STRUCTURAL REHABILITATION, REMODEL, AND ADDITION TO A FOUR-UNIT APARTMENT BUILDING LOCATED AT 3232 HERMOSA AVE IN THE MULTIPLE FAMILY RESIDENTIAL (R-3) ZONE - 25-CDD-165 Page 16 of 324 5 CEQA: Determine the project is categorically exempt from the California Environmental Quality Act. (Associate Planner Jake Whitney) Associate Planner Jake Whitney provided a presentation. Planning Commissioners asked questions and received answers from staff. Applicant's representative Brandon Straus spoke. Applicant's representative Kit Bobko spoke. Public Comment was provided by:  Nancy Schwappach (virtual) Applicant's representative Brandon Straus spoke. Planning Commissioners deliberated. Community Development Director Alison Becker spoke. Planning Commissioners deliberated. Moved by: Commissioner Michael Flaherty Seconded by: Commissioner Peter Hoffman Staff recommends that the Planning Commission: 1. Determine that the project is categorically exempt from the California Environmental Quality Act (CEQA) per Section 15302 of the State CEQA Guidelines; and 2. Adopt a Resolution (Attachment 1) approving Convex Slope Determination (CSD 25-01) and Precise Development Plan 25-05 subject to conditions of approval as amended. Condition of Approval number 4 was modified to read " Prior to issuance of a demolition permit, if the owner does not provide evidence that none of the existing units are “Protected Units” under state law, the owner shall execute a covenant to the satisfaction of the Community Development Director to make two (2) units available for rent to “Lower Income Households” as defined by California Health and Safety Code 50079.5 for a period of at least 55 years. Such units must be of an “equivalent size” as defined by California Government Code Section 65915. Enforcement of the terms of said covenant shall be the responsibility of the City of Hermosa Beach and its authorized agents. The Applicant shall submit a copy of the recorded covenant to the Community Development Department for inclusion in this file." Additionally, Condition of Approval number 13 Page 17 of 324 6 was modified to read "A Encroachment Permit is required for any new or existing non-conforming structures or uses located over or within the public right-of-way". Ayes (5): Chairperson Kate Hirsh, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, and Commissioner McNally Motion Carried 7.d PRECISE DEVELOPMENT PLAN (PDP 23-06) FOR THE REMODEL OF AN EXISTING TWO-STORY SINGLE-FAMILY RESIDENCE AND REMODEL OF AN EXISTING TWO-CAR GARAGE WITH SECOND FLOOR WORKSHOP INTO A RESIDENCE WITH FOUR GARAGE PARKING SPACES- 25-CDD-163 CEQA: Determine the project is exempt from the California Environmental Quality Act. (Contract Planner Kaneca Pompey) Contract Planner Kaneca Pompey delivered a presentation. Planning Commissioners posed questions and received answers. Applicant's representative addressed the Planning Commission Moved by: Commissioner Peter Hoffman Seconded by: Commissioner Michael Flaherty Staff recommends the Planning Commission: 1. Determine the project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to section 15301, Class 1; 2. Adopt a Resolution approving Precise Development Plan (PDP 23- 06) to remodel an existing two-story single-family residence and remodel of an existing two-car garage with second floor workshop into a residence with four garage parking spaces, subject to conditions of approval (Attachment 1) Ayes (5): Chairperson Kate Hirsh, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, and Commissioner McNally Motion Carried 8. STAFF ITEMS Page 18 of 324 7 8.a COMMUNITY DEVELOPMENT DIRECTOR REPORT Community Development Director Alison Becker announced that at the December Planning Commission meeting there would be a rotation of chairperson role and that a schedule for the Planning Commission meetings for the following year would be provided. 9. PLANNING COMMISSION COMMENTS Planning Commission members may briefly respond to public comments, may ask a question for clarification, or make a brief announcement or report on his or her own activities or meetings attended. Commissioner Flaherty and Commissioner Hoffman discussed issues regarding technical difficulties. Commissioner Hoffman and Commissioner Flaherty discussed the timing of future special meetings. Community Development Director Alison Becker responded. Chairperson Hirsh provided comment. 10. FUTURE AGENDA ITEMS Questions from Planning Commission members regarding the status of future agenda items. No discussion or debate of these requests shall be undertaken. 10.a PLANNING COMMISSION TENTATIVE FUTURE AGENDA - 25-CDD- 159 (Planning Manager Alexis Ororpeza) Moved by: Commissioner Peter Hoffman Seconded by: Commissioner Michael Flaherty Staff recommend Planning Commission receive and file the tentative future agenda for the Planning Commission regular meeting of December 16, 2025. Ayes (5): Chairperson Kate Hirsh, Commissioner Peter Hoffman, Vice Chairperson Stephen Izant, Commissioner Michael Flaherty, and Commissioner McNally Motion Carried 11. PUBLIC COMMENT This time is set aside for the public to address the Commission on any item of interest within the subject matter jurisdiction of the Commission that could not be heard under Item 4 during the first public participation item because there were too many prior public speakers and the thirty-minute maximum time limit was exhausted. Page 19 of 324 8 No public comment provided. 12. ADJOURNMENT The meeting was adjourned at 10:46pm. Page 20 of 324 City of Hermosa Beach | Page 1 of 3 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-172 Honorable Chair and Members of the Hermosa Beach Planning Commission LOCATION: 620 9TH STREET TWO YEAR TIME EXTENSION REQUEST FOR A CONDITIONAL USE PERMIT (CUP 23-10), PRECISE DEVELOPMENT PLAN (PDP 23-07), AND VESTING TENTATIVE PARCEL MAP (VTPM NO 84231) FOR A 3-UNIT ATTACHED CONDOMINIUM PROJECT AT 620 9TH STREET IN THE TWO-FAMILY RESIDENTIAL (R-2) ZONE. CEQA: Determine that the project remains categorically exempt from the California Environmental Quality Act pursuant to the previously approved Class 3 Exemption for New Construction as defined in Section 15303(b) of the CEQA guidelines. Recommended Action: Staff recommends that the Planning Commission: 1. Determine the project remains categorically exempt from the California Environmental Quality Act (CEQA) pursuant to the previously approved Class 3 Exemption for New Construction as defined in Section 15303(b) of the CEQA guidelines and; 2. Adopt by Minute Order a two-year time extension for Conditional Use Permit 23- 10, Precise Development Plan 23-07, and Vesting Tentative Parcel Map No 84231 for a 3-unit attached condominium project. Background: The project site is an interior 5,413-square-foot lot located in the Two-Family Residential (R-2) zone and is currently developed with a single-family residence. An application was filed on August 8, 2023 by the applicants Brett Drogmund and Pricilla Lee for a Conditional Use Permit (23-10), Precise Development Plan (23-07), and Vesting Tentative Parcel Map (No 84231) for a three-unit attached condominium project at 620 9th Street. On December 11, 2023 the Planning Commission held a duly noticed public hearing to consider the application and ultimately approved the project and all requested entitlements via Planning Commission Resolution No. 23-25. Furthermore, Condition No. 26 of the approval resolution states that approval of the permits shall expire 24 months from the date of approval, and that one or more-time extensions may be requested in writing to the Director of the Community Development Department (Attachment 1). In accordance with Page 21 of 324 City of Hermosa Beach | Page 2 of 3 this condition, the applicants subsequently file for an extension that was received by the Department on October 7, 2025. Past Board, Commission, and Council Actions Meeting Date Description December 11, 2023 The Planning Commission holds a duly noticed public hearing and approves PC Resolution 23-25 for a new 3- unit attached condominium project located at 620 9th Street. Project Description: The project consists of a two-year extension of the planning entitlements for a previously approved three-unit attached condominium project located at 620 9th Street. The approved plans call for the demolition of the existing duplex on site, resulting in the net increase of one unit on the subject property. Discussion: Hermosa Beach Municipal Code (HBMC) Section 17.70.020 specifies that all permits or variances granted by the Planning Commission or City Council become null and void if not established within the date specified in such permit or variance, or if no date is specified, within two (2) years from the date of approval of such permit or variance. Furthermore, One (1) or more extensions of time may be requested by filing a written request with the Community Development Department at least thirty (30) days prior to the expiration date, including the reason therefor and payment of a fee set by resolution of the City Council. The Planning Commission may deny, approve or conditionally approve each extension for a period not to exceed two (2) years; provided that a public hearing shall be held pursuant to HBMC Chapter 17.68 prior to amendment of permit conditions. The applicant indicated that additional time was needed as the plans are currently in plan check and they are working on securing additional soil testing. As a result, the applicant will not be ready to begin construction before the expiration of the initial approval. The applicant tentatively expects to complete plan check by June of 2026 with construction expected to begin following approval (Attachment 2). Staff supports the two-year time extension of the project to allow the applicant sufficient time to complete the plan check process and provide assurances for project continuity. Environmental Determination: Pursuant to the California Environmental Quality Act (CEQA), the proposed project remains categorically exempt pursuant to previously approved Class 3 Exemption for New Construction as defined in Section 15303(b) of the CEQA guidelines. Moreover, Page 22 of 324 City of Hermosa Beach | Page 3 of 3 none of the exceptions to the categorical exemption(s) apply, nor would the project result in a significant cumulative impact of successive projects of the same type in the same place over time or have a significant effect on the environment due to unusual circumstances or damage a scenic highway or scenic resources within a state scenic highway. The project site is also not considered a historic or potentially historic resource based on the City’s 2013 historic resource windshield survey. Attachments: 1. PC Resolution 23-25 2. Applicant’s Time Extension Request Letter Respectfully Submitted by: Jake Whitney, Associate Planner Legal Review: Sarah Locklin, Interim City Attorney Concur: Alexis Oropeza, Planning Manager Approved: Alison Becker, Community Development Director Page 23 of 324 Page 24 of 324 Page 25 of 324 Page 26 of 324 Page 27 of 324 Page 28 of 324 Page 29 of 324 Page 30 of 324 Page 31 of 324 Page 32 of 324 Page 33 of 324 Page 34 of 324 Page 35 of 324 Page 36 of 324 Page 37 of 324 Page 38 of 324 Page 39 of 324 Page 40 of 324 Page 41 of 324 https://esrour.sharepoint.com/Shared Documents/WORD/1-Nondre/2-4UNITS/HB/620 9th/City App/Extension/Letter of Request for Extension.doc SROUR & ASSOCIATES Real Estate Development Services Group, Inc. 2615 Pacific Coast Highway, Suite 206, Hermosa Beach, CA 90254 310/372-8433 ▪ srour@esrour.com ▪ www.srourandassociates.com November 6, 2025 Jake Whitney, Associate Planner City of Hermosa Beach Community Development Department Planning Division 1315 Valley Drive Hermosa Beach, CA 90254 Dear Mr. Whitney, Thank you for your assistance with the application for extension of the entitlement: PDP 23-07 and CUP 23-10-time extension for 620 9th Street, a 3-unit condominium project. The applicant requests an extension of the Precise Development Plan and Use Permit, as the applicant is currently in plan check for the construction drawings and will not be ready to start construction prior to the expiration of the initial approval. The plan check comments call for additional soils testing to determine if there are corrosives that may impact the construction materials, as well as coordination of site drainage and architectural design to ensure there will not be impacts to the structure. This process is taking longer than the initial 24-month entitlement period that was given by the Planning Commission. The applicant expects to have completed plan check by June 1, 2026, and construction to start immediately following. Thank you again for your assistance and consideration of this request. Sincerely, Stacy Straus On behalf of property owners Brett Drogmund and Priscilla Lee Page 42 of 324 City of Hermosa Beach | Page 1 of 7 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-171 Honorable Chair and Members of the Hermosa Beach Planning Commission LOCATION: 1054 AVIATION BOULEVARD PRECISE DEVELOPMENT PLAN (PDP25-01) FOR NEW 6,487-SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING, AT 1054 AVIATION BOULEVARD, LOCATED WITHIN THE GENERAL COMMERCIAL ZONE (C-3). CEQA: Determine the project is exempt from the California Environmental Quality Act. (Assistant Planner Johnny Case) Recommended Action: Staff recommends the Planning Commission: 1. Determine the project is categorically exempt from the California Environmental Quality Act (CEQA); and 2. Adopt a Resolution approving a Precise Development Plan (PDP25-01) for a new 6,487 square-foot multi-tenant commercial building located at 1054 Aviation Boulevard, subject to conditions of approval (Attachment 1). Executive Summary: This is a request for approval of a Precise Development Plan (PDP25-01) to demolish an existing commercial structure and propose a new 6,487 square-foot multi-tenant building. Staff recommend that the Planning Commission approve the project subject to conditions of approval and determine that the project is categorically exempt from the California Environmental Quality Act. Background: The project site is an existing 16,696-square-foot lot located within the Aviation Corridor character area. The project site is located on the South side of Aviation Boulevard and is at the corner of Aviation Boulevard and Owosso Avenue. The site has a General Plan land use designation of Community Commercial (CC) and is zoned as General Commercial (C-3) (Attachment 2). Additionally, the project is not located within the Coastal Zone. The site is currently developed with a 4,765-square-foot commercial structure and surface parking. The site was developed in 1945. Page 43 of 324 City of Hermosa Beach | Page 2 of 7 Site Information Table: The following table describes the existing site characteristics Site Information General Plan Community Commercial (CC) Zoning General Commercial (C-3) Lot Size 16,696 square feet Surrounding Zoning North: C-3 East: C-3 and R-2 South: R-1 West: C-3 Surrounding Uses North: Vacant East: Office South: Residential West: Retail Project Description: The proposed project involves demolishing the existing 4,765-square-foot, single-story commercial building and replacing it with a 6,487-square-foot multi-tenant commercial building. The new building would feature tenant spaces of varying sizes:  Retail space one: 647 square feet  Retail space two: 1,565 square feet  Retail space three: 1,306 square feet  Retail space four: 897 square feet In addition, the structure would include an 886-square-foot mezzanine for storage within retail space one (1), and a 185 square-foot common area that would contain the trash bins, janitor’s office, and a unisex toilet. The project includes a new surface parking lot with 25 parking spaces. Discussion: The following provides a summary of the Development Standards for the General Commercial Zone (C-3). Criteria Required Provided LOT STANDARDS HEIGHT: 35 feet 24 feet 11 inches YARDS: Front Not Required 0 feet to 8 feet 8 inches (varies) Side 8 feet 8 foot minimum (varies) Rear 8 feet 22 feet 8 inches PARKING: Total Parking Spaces Minimum 25 spaces 25 spaces Page 44 of 324 City of Hermosa Beach | Page 3 of 7 Parking/Vehicular Access The proposed parking is arranged to be located to the side and behind the proposed building. Vehicular access is provided via a driveway off Aviation Boulevard, which would serve as an entrance only. Vehicles would exit from an existing driveway on Owosso Avenue. Per HBMC Section 17.44.030, offices and general retail uses require one (1) space per 250 square feet of gross floor area, requiring this project to provide a total of 25 parking spaces. The project proposes a total of 25 spaces, consisting of 16 standard spaces, eight (8) compact spaces, and one (1) accessible parking space. Site/ Floor Plan The project proposes a new multi-tenant commercial building comprising four units. The primary pedestrian entrances are oriented towards Aviation Boulevard and Owosso, with additional entrances located behind the building and serve the proposed parking lot. Landscape The project adds 642 square feet of new landscaping, bringing the total on-site landscaping to 1,104 square feet. The new landscaping would enhance the buffer between adjacent residential zones and would be incorporated along the property frontage, improving the overall building façade. All on-site landscaping is subject to HBMC Chapter 8.60, Water Efficient Landscaping. Additionally, the project will be conditioned to comply with low-impact development standards and to reduce urban runoff, subject to HBMC Section 8.44.095(F)(1). This project application was routed for review by various city departments, including Building and Safety, Public Works, and the Environmental Programs Manager in the City Manager’s office. The noted departments do not object to the proposed PDP subject to the conditions of approval set forth in the draft Resolution (Attachment 1). Findings: A Precise Development Plan may only be approved or conditionally approved when positive findings can be made for all the findings pursuant to Hermosa Beach Municipal Code (HBMC) Section 17.58.040. In accordance with Hermosa Beach Municipal Code (HBMC) Sections 17.58.010 and 17.58.020, in order to promote excellence in design, layout, and physical features of development to achieve reasonable quality and compatibility with its surroundings, all remodels or additions exceeding 1,500 square feet require a Precise Development Plan issued by the Planning Commission. In considering an application for a Precise Development Plan, City staff reviews the project using the review considerations for Precise Development Plans identified in HBMC Section 17.58.030. The review considerations are used to help inform the three required findings which must be made pursuant to Hermosa Beach Municipal Code Section 17.58.040 in order to approve a PDP. Page 45 of 324 City of Hermosa Beach | Page 4 of 7 Review Considerations for a PDP 1. Building proportions, massing, and architectural details; 2. Site design, orientation, location, and architectural design of buildings relative to existing structures on or adjacent to the property, topography, and other physical features of the natural and built environment; 3. Size, location, design, development, and arrangement of site access for modes of transportation, including on-site vehicle and bicycle parking; 4. Height, materials, and design of fences, walls, and screen plantings; 5. Location and type of landscaping including selection and size of plant materials, and design of hardscape; and 6. Size, location, design, color, lighting, and materials of all signs. 1. The design, layout and other physical features of the project comply with all other applicable provisions of this Title [Title 17, Zoning] and all other titles of the Hermosa Beach Municipal Code; The design, layout, and physical features of the project do comply with all applicable provisions of the Hermosa Beach zoning code and all other titles of the Hermosa Beach Municipal Code. The project consists of demolishing the existing 4,765-square-foot, single-story one (1) tenant commercial building, and proposes a 6,487-square-foot four (4) tenant building. The proposed building is of a modern design which would enhance the aesthetics of the site and the broader community. Additionally, the proposed project proposes 642 square feet of new landscape to the existing and maintains 462 square feet of existing landscaping already provided on site. The new landscaping would enhance the buffer between adjacent residential zones and would be incorporated along the property frontage, complementing the overall building façade. The new landscaping advances the City’s goal of landscape enhancement in accordance with PDP review consideration number five (5) as listed above. 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; and The subject property has a General Plan land use designation of Community Commercial (CC) and there are no applicable specific plans or design guidelines. The purpose of this designation is to provide opportunities and location for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is located within the Aviation Corridor character area, which aims to provide ground-floor uses to serve the daily needs of residents east of Pacific Coast Highway. Buildings within the Aviation Corridor shall be one (1) or two (2) stories tall, have high-quality signage/materials and maximum Page 46 of 324 City of Hermosa Beach | Page 5 of 7 transparency in order to attract shoppers, arranged along the side or behind the building. This proposed project would demolish the existing building and propose a new building of a more modern aesthetic, inclusive of a variety of material to create interest and break monotony. The front of the proposed building, facing Aviation Boulevard, consists of large windows promoting high levels of transparency. Additionally, the proposed parking is arranged to be located behind the proposed building. The design, layout, and other physical features of the proposed project are consistent with the General Plan Goal & Policies as further described below: General Plan Consistency Goals & Policies Findings Land Use Element Goal 1: Create a sustainable urban form and land use patterns that support a robust economy and high quality of life for residents. Policy 1.3 Access to daily activities. Strive to create sustainable development patterns such that the majority of residents are within walking distance to a variety of neighborhood goods and services Policy 1.7 Compatibility of Uses. Ensure the placement of new uses does not create or exacerbate nuisances between different types of land uses. The proposed project will increase access to services in the community and contributes to more options for residents to have access to daily activities. All future uses will be subject to compliance with the permitted used of the zone per the city’s municipal code. Goal 3: A series of unique, destination- oriented districts throughout Hermosa Beach. Policy 3.3 Diverse retail and office centers. Provide incentives to transform existing single-use commercial properties that are accessible into retail destinations by adding a diversity of uses, providing new pedestrian connections to adjacent residential areas, reducing the visual prominence of parking lots, making the centers more pedestrian-friendly and enhancing the definition and character of street frontage and associated streetscapes. The proposed project will be transforming existing single-use commercial properties into a four-tenant space which will add diversity of uses provided to the residents and visitors of the region. Goal 6: A pedestrian focused urban form that creates visual interest and comfortable outdoor environment. The proposed project incorporates human scaled details by incorporating large windows and awnings along the Page 47 of 324 City of Hermosa Beach | Page 6 of 7 General Plan Consistency Goals & Policies Findings Policy 6.6 Human scaled buildings. Encourage building and design to include human-scale details such as windows on street, awnings and architectural features that create a visual interesting pedestrian environment. Policy 6.7 Pedestrian oriented design. Eliminate urban form conditions that reduce walkability by discouraging surface parking and parking structures along walkways, long blank walls along walkways, and garage dominated building facades. pedestrian pathway along Aviation Boulevard. The modern aesthetic of the proposed building incorporates a variety of materials creating visually interesting façade along Aviation Boulevard. The proposed project promotes walkability as the proposed parking is located behind the proposed building, away from pedestrian walkways Along Aviation Boulevard, and rather than long blank walls the project proposes a façade inclusive of a variety of materials to create interest and breaks monotony. Parks & Open Space Element Goal 5. Scenic vistas, viewpoints, and resources are maintained or enhanced Policy 5.7 Light pollution. Preserve nighttime skyward views and reduce glare by minimizing shoreline lighting levels. Nighttime views would be protected by a condition of approval requiring all exterior lighting to be downcast to minimize light pollution. 3. The design, layout and other physical features of the project comply with any design or development standards applicable to the zone, unless waived or modified pursuant to the provisions of this Title. The subject property has a Zoning designation of General Commercial (C-3) and is not located in the Coastal Zone. The design, layout and physical features of the project do comply with the design and development standards applicable to the zone, including maximum building height, setbacks, and parking requirements. The building height does not exceed 35 feet in height as required in the C-3 zoning district. This compliance with existing height standards directly conforms with PDP review consideration number four (4). The Project has not requested waiver or modification of applicable design or development standards. Environmental Analysis: Pursuant to the California Environmental Quality Act (CEQA), the proposed project qualifies for a Class 3 categorical exemption, as defined in 15303 of the CEQA Guidelines, for New Construction as it consists of a commercial structure less than 10,000 square feet in floor area not containing hazardous substances within an urbanized area. Moreover, none of the exceptions to the categorical exemption(s) apply to the project, as defined in Section 15300.2 of the State of CEQA Guidelines. The project would not result in a significant cumulative impact of successive project of the same type in the same place over time; the project would not have a significant effect on the environment due to unusual circumstances; the project would not damage a scenic highway or scenic Page 48 of 324 City of Hermosa Beach | Page 7 of 7 resources within a state scenic highway; the project is not located on a hazardous waste site; and the project would not cause a substantial adverse change in the significance of a historical resource. The property was further not found to be listed on the City’s inventory of Potentially Historic Resources pursuant to Figure 7.2 of Appendix C of the PLAN Hermosa Program Environmental Impact Report. Public Notification: For the December 16, 2025 Planning Commission hearing, a total of 475 public hearing notices were mailed to the applicant, occupant, and property owner of properties within a 500-foot radius on December 3, 2025. A legal ad was published on December 4, 2025 in the Easy Reader, a newspaper of general circulation. Additionally, the applicant received two notice posters to post on-site and provided proof of posting a minimum of ten days in advance of the public hearing, in accordance with Hermosa Beach Municipal Code (HBMC) § 17.68.050. Public notification materials are included as Attachment 4. As of writing the report, the staff have received no public comments. Attachments: 1. Draft Resolution 2. Zoning Map 3. Project Plans 4. Public Notification Package Respectfully Submitted by: Johnny Case, Assistant Planner Concur: Alexis Oropeza, Planning Manager Legal Review: Sarah Locklin, Interim City Attorney Approved: Alison Becker, Community Development Director Page 49 of 324 1 PC Resolution 25-XX A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, APPROVING, PRECISE DEVELOPMENT PLAN (PDP 25-01) FOR NEW 6,487-SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING, AT 1054 AVIATION BOULEVARD, LOCATED WITHIN THE GENERAL COMMERCIAL ZONE (C-3) AND DETERMINING THAT THE PROJECT IS CATEGORICALLY EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA). The Planning Commission of the City of Hermosa Beach does hereby resolve, and order as follows: WHEREAS, on April 15, 2025, applicant Michael Greenberg (“applicant”), filed a development application seeking approval Precise Development Plan 25-01, (the “project”) for the construction of a new multi-tenant building at 1054 Aviation Boulevard in Hermosa Beach (“project site”); and WHEREAS, in accordance with Hermosa Beach Municipal Code (“HBMC”) Section 17.58.010 and 17.58.020, in order to promote excellence in design, layout, and physical features of development to achieve reasonable quality and compatibility with its surroundings, all remodels or additions exceeding 1,500 square feet require a Precise Development Plan issued by the Planning Commission; and WHEREAS, the Planning Commission conducted a duly noticed public hearing to consider the subject application on December 16, 2025, at which time testimony and evidence, both written and oral, was presented to and considered by the Planning Commission; and WHEREAS, the proposed project is Categorically Exempt from the California Environmental Quality Act as defined in Section 15303(c), Class 3 Exemption, New Construction or Conversion of Small Structures, because the proposal pertains to construction of one new structure. More specifically, the project is comprised of the construction of a commercial building not exceeding 10,00-square-feet in floor area in an urbanized area. Section 15300.2 of the CEQA Guidelines list the exceptions to the exemption and these exceptions to the exemptions define circumstances that override or negate the City’s ability to use a categorical exemption. Specifically, these exceptions to Page 50 of 324 2 the exemptions are:  The project is located in a sensitive environment such that the project may impact an officially mapped and designated environmental resource of hazardous or critical concern;  The cumulative effect of successive projects of the same type in the same place, over time, is significant;  The project may have a significant environmental impact due to unusual circumstances;  The project may damage scenic resources (i.e. trees, historic buildings, or rock outcroppings) within an official state scenic highway;  The project is located on a listed hazardous waste site; None of the exceptions to the Categorical Exemptions apply, nor will the location of the project impact an environmental resource of hazardous or critical concern. The project will not result in a significant cumulative impact of successive projects of the same type in the same place over time or have a significant effect on the environment due to unusual circumstances or damage a scenic highway or scenic resources within a state scenic highway. The site is not located on a hazardous waste site and will not cause a substantial adverse change in the significance of a historical resource. The existing home is not a significant landmark in the City nor is it considered a potential historic resource, as the property was not found to be listed on the City’s inventory of Potentially Historic Resources pursuant to Figure 7.2 of Appendix C of the PLAN Hermosa Program Environmental Impact Report. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: Section 1. Based on the testimony and evidence received, the Planning Commission hereby finds, determines, and declares the following pertaining to the application for Precise Development Plan 25-01 pursuant to Sections 17.58.030 and 17.58.040 of the Hermosa Beach Municipal Code. 1. The design, layout, and other physical features of the project comply with all other applicable provisions of this Title [Title 17, Zoning] and all other titles of the Hermosa Beach Municipal Code; The design, layout, and physical features of the project do comply with all applicable provisions of the Hermosa Beach zoning code and all other titles of the Hermosa Beach Municipal Code. The project consists of demolishing the existing 4,765-square-foot, single-story one (1) tenant commercial building, and proposes a 6,487 square foot Page 51 of 324 3 four (4) tenant building. The proposed building is of a modern design which would enhance the aesthetics of the site and the broader community. Additionally, the proposed project proposes 642 square feet of new landscape to the existing and maintains 462 square feet of existing landscaping already provided on site. The new landscaping would enhance the buffer between adjacent residential zones and would be incorporated along the property frontage, complementing the overall building façade. The new landscaping advances the City’s goal of landscape enhancement in accordance with PDP review consideration number five (5). 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; and The subject property has a General Plan land use designation of Community Commercial (CC) and there are no applicable specific plans or design guidelines. The purpose of this designation is to provide opportunities and location for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is located within the Aviation Corridor character area, which aims to provide ground-floor uses to serve the daily needs of residents east of Pacific Coast Highway. Buildings within the Aviation Corridor shall be one (1) or two (2) stories tall, have high-quality signage/materials and maximum transparency in order to attract shoppers, arranged along the side or behind the building. This proposed project would demolish the existing building and propose a new building of a more modern aesthetic, inclusive of a variety of material to create interest and break monotony. The front of the proposed building, facing Aviation Boulevard, consists of large windows promoting high levels of transparency. Additionally, the proposed parking is arranged to be located behind the proposed building. The design, layout, and other physical features of the proposed project are consistent with the General Plan Goals & Policies as further described below: General Plan Consistency Goals & Policies Goals & Policies Land Use Element Page 52 of 324 4 General Plan Consistency Goals & Policies Goals & Policies Goal 1: Create a sustainable urban form and land use patterns that support a robust economy and high quality of life for residents. Policy 1.3 Access to daily activities. Strive to create sustainable development patterns such that the majority of residents are within walking distance to a variety of neighborhood goods and services Policy 1.7 Compatibility of Uses. Ensure the placement of new uses does not create or exacerbate nuisances between different types of land uses. The proposed project will increase access to services in the community and contributes to more options for residents to have access to daily activities. All future uses will be subject to compliance with the permitted used of the zone per the city’s municipal code. Goal 3: A series of unique, destination- oriented districts throughout Hermosa Beach. Policy 3.3 Diverse retail and office centers. Provide incentives to transform existing single-use commercial properties that are accessible into retail destinations by adding a diversity of uses, providing new pedestrian connections to adjacent residential areas, reducing the visual prominence of parking lots, making the centers more pedestrian-friendly and enhancing the definition and character of street frontage and associated streetscapes. The proposed project will be transforming existing single-use commercial properties into a four-tenant space which will add diversity of uses provided to the residents and visitors of the region. Goal 6: A pedestrian focused urban form that creates visual interest and comfortable outdoor environment. Policy 6.6 Human scaled buildings. Encourage building and design to include human-scale details such as windows on street, awnings and architectural features The proposed project incorporates human scaled details by incorporating large windows and awnings along the pedestrian pathway along Aviation Boulevard. The modern aesthetic of the proposed building incorporates a variety Page 53 of 324 5 General Plan Consistency Goals & Policies Goals & Policies that create a visual interesting pedestrian environment. Policy 6.7 Pedestrian oriented design. Eliminate urban form conditions that reduce walkability by discouraging surface parking and parking structures along walkways, long blank walls along walkways, and garage dominated building facades. of materials creating visually interesting façade along Aviation Boulevard. The proposed project promotes walkability as the proposed parking is located behind the proposed building, away from pedestrian walkways Along Aviation Boulevard, and rather than long blank walls the project proposes a façade inclusive of a variety of materials to create interest and breaks monotony. Parks & Open Space Element Parks & Open Space Element Goal 5. Scenic vistas, viewpoints, and resources are maintained or enhanced Policy 5.7 Light pollution. Preserve nighttime skyward views and reduce glare by minimizing shoreline lighting levels. Nighttime views would be protected by a condition of approval requiring all exterior lighting to be downcast to minimize light pollution. 3. The design, layout, and other physical features of the project comply with any design or development standards applicable to the zone, unless waived or modified pursuant to the provisions of this Title. The subject property has a Zoning designation of General Commercial (C-3) and is not located in the Coastal Zone. The design, layout and physical features of the project do comply with the design and development standards applicable to the zone, including maximum building height, setbacks, and parking requirements. The building height does not exceed 35 feet in height as required in the C-3 zoning district. This compliance with existing height standards directly conforms with PDP review consideration number four (4). The project has not requested waiver or modification of applicable design or development standards. Section 2. Based on the foregoing, the Planning Commission hereby approves the subject Precise Development Plans for the construction of a new 6,487 square-foot Page 54 of 324 6 multi-tenant commercial building located at 1054 Aviation Boulevard (PDP 25-01) as set forth in Planning Commission Resolution 25-XX, subject to the following Conditions of Approval: General: 1. The development and continued use of the property shall be in conformance with submitted plans received and reviewed by the Planning Commission at its meeting of December 16, 2025 in accordance with the conditions below. The Community Development Director may approve minor modifications that do not otherwise conflict with the HBMC or requirements of this approval. 2. The project shall fully comply with all requirements of the C-3 Zone as applicable and the Condominium Ordinance in Chapter 17.22 of the Hermosa Beach Municipal Code (HBMC), including but not limited to: a) Height, including required all roof-mounted equipment, shall fully comply with the 35-foot height limit. Precise building height compliance shall be reviewed at the time of building plan review, to the satisfaction of the Community Development Director. Design and construction shall comply with HBMC Section 17.22.060 except as specifically stated in this Resolution. b) Architectural treatments and accessory facilities shall be as shown on building elevations, site, and floor plans. 3. The project shall comply with all requirements of the Building Division, Public Works Department, Fire Department, and HBMC. 4. This approval shall not be effective for any purposes until the permittee and the owners of the property involved have filed at the office of the Planning Division of the Community Development Department with their affidavits stating that they are aware of, and agree to accept, all of the conditions of this grant. The Conditional Use Permit and Precise Development Plan shall be recorded, and proof of recordation shall be submitted to the Community Development Department prior to the issuance of a building permit. 5. Approval of this permit shall expire twenty-four (24) months from the date of Page 55 of 324 7 approval by the Planning Commission unless significant construction or improvements or the use authorized hereby has commenced. One or more extensions of time may be requested. No extension shall be considered unless requested, in writing to the Community Development Director including the reason therefore, at least 60 days prior to the expiration date. No additional notice of expiration shall be provided. 6. The Planning Commission may review this Precise Development Plan and may amend the subject conditions or impose any new conditions if deemed necessary to mitigate detrimental effects on the surrounding neighborhood. 7. The subject property shall be developed, maintained, and operated in full compliance with the conditions of this permit and any law, statute, ordinance, or other regulation applicable to any development or activity on the subject property. Failure of the permittee to cease any development or activity not in full compliance shall be a violation of these conditions. 8. To the extent permitted by law, Permittee shall defend, indemnify and hold harmless the City of Hermosa Beach, its City Council, its officers, employees and agents (the “indemnified parties”) from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void any permit or approval for this project authorized by the City, including (without limitation) reimbursing the City its actual attorney’s fees and costs in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. The permittee shall reimburse the City for any court and attorney's fees which the City may be required to pay as a result of any claim or action brought against the City because of this permit. Although the permittee is the real party in interest in an action, the City may, at its sole discretion, participate at its own expense in the defense of the action, but such participation shall not relieve the permittee of any obligation under this condition. 9. Each of the above conditions is separately enforced, and if one of the conditions of approval is found to be invalid by a court of law, all the other conditions shall remain valid and enforceable. Planning: Page 56 of 324 8 10. All conditions of approval shall be printed verbatim on all plans submitted for plan review to the Community Development Department. These conditions shall be indexed on the cover sheet and referenced on the site plan. 11. Any proposed onsite landscaping shall comply with HBMC Chapter 8.60, Water Efficient Landscaping and HBMC Section 8.44.095(F)(1) and must be submitted to the Community Development Department for approval. 12. Any proposed roof-top mounted equipment shall be screened to the satisfaction of the Community Development Director or designee. 13. Lighting: Outdoor lighting and lighting for signs associated with commercial uses designed so as not to adversely impact residences. No flashing, blinking or high intensity lighting. Adequate lighting to illuminate parking areas and corridors to access parking and public sidewalk. Lighting for signs may only be illuminated during business hours. 14. Lighting: All exterior lighting shall be downcast, fully shielded and illumination shall be contained within the property boundaries. Lighting shall be energy conserving and motion detector lighting shall be used for all lighting except low-level (3 feet or less in height) security lighting and porch lights. Lamp bulbs and images shall not be visible from within any onsite or offsite residential unit. Exterior lighting shall not be deemed finally approved until 30 days after installation, during which period the building official may order the dimming or modification of any illumination found to be excessively brilliant or impacting to nearby properties. 15. Signs: All proposed signage shall comply with the requirements of HBMC Chapter 17.50, Signs. 16. Window Treatments: Reflective window tints shall be prohibited on all windows. The ground floor street-facing windows shall provide a minimum visible light transparency transmittance level of 50 percent. 17. The applicant shall comply with all applicable mitigation measures of the General Plan Program EIR (SCH No. 201581009) as adopted by the City Council including: a) Construction projects within the city shall demonstrate compliance with all Page 57 of 324 9 applicable standards of the Southern California Air Quality Management District, including the following provisions of District Rule 403: i. All unpaved demolition and construction areas shall be wetted at least twice daily during excavation and construction, and temporary dust covers shall be used to reduce dust emissions and meet SCAQMD Rule 403. Wetting could reduce fugitive dust by as much as 50 percent. ii. The construction area shall be kept sufficiently dampened to control dust caused by grading and hauling, and at all times provide reasonable control of dust caused by wind. iii. All clearing, earth moving, or excavation activities shall be discontinued during periods of high winds (i.e., greater than 15 mph), so as to prevent excessive amounts of dust. iv. All dirt/soil loads shall be secured by trimming, watering, or other appropriate means to prevent spillage and dust. v. All dirt/soil materials transported off-site shall be required to cover their loads as required by California Vehicle Code Section 23114 to prevent excessive amount of dust. vi. General contractors shall maintain and operate construction equipment so as to minimize exhaust emissions. vii. Trucks having no current hauling activity shall not idle but shall be turned off (MM 4.2-2A). b) In accordance with Section 2485 in Title 13 of the California Code of Regulations, the idling of all diesel-fueled commercial vehicles (weighing over 10,000 pounds) during construction shall be limited to 5 minutes at any location (MM 4.2-2b). c) Construction projects within the city shall comply with South Coast Air Quality Management District Rule 1113 limiting the volatile organic compound Page 58 of 324 10 content of architectural coatings (MM 4.2-2c). For any project where earthmoving or ground disturbance activities are proposed at depths that encounter older Quaternary terrace deposits (depths between 15 and 35 feet), a qualified paleontologist shall be present during excavation or earthmoving activities (MM 4.4- 3). d) If paleontological resources are discovered during earthmoving activities, the construction crew shall immediately cease work in the vicinity of the find and notify the City. The project applicant(s) shall retain a qualified paleontologist to evaluate the resource and prepare a recovery plan in accordance with Society of Vertebrate Paleontology guidelines (1996). The recovery plan may include, but is not limited to, a field survey, construction monitoring, sampling and data recovery procedures, museum storage coordination for any specimen recovered, and a report of findings. Recommendations in the recovery plan that are determined by the lead agency to be necessary and feasible shall be implemented before 11 construction activities can resume at the site where the paleontological resources were discovered (MM 4.4-3). Building: At the time of building and safety plan check submittal, plans shall demonstrate compliance with the following: 18. The area designated as Mezzanine Storage, will require more clarification and details to ensure fire ratings, use, etc. 19. This proposed project is a core and shell, which will require additional submittals for the tenant improvements before occupancy is allowed. 20. Submit all architectural, structural, grading, shoring, and associated plans for plan review and approval and acquire all required permits. 21. Include electrical calculations, single line, and placement of any utility equipment (as required per the utility providers). It is recommended that the applicant contact all of the utilities to ensure that the project site accounts for the placement of all utilities, including; Fire Department Connection, Electrical Transformers, and any other required utility meters. Page 59 of 324 11 22. Include the location of proposed utilities; sewer lines, main water line, etc. 23. Separate submittal and plan approval required from LA County Fire Land Development Unit, prior to permit issuance. Separate submittal and plan approval required from LA County Fire Sprinkler Unit prior to framing approval Public Works: 24. No new walls or foundation footing will be allowed to be constructed on or over the public right-of-way. 25. A residential encroachment permit is required for non-confirming structures located over or within the public right-of-way. 26. If public improvements are required. The following items are required, Items 3-8. Prior to issuance of a building permit, an approved civil engineering plans prepared by a licensed civil engineer, and approved by Public Works, addressing grading, undergrounding of all utilities, pavement, sidewalk, curb and gutter improvements, on-site and off-site drainage (no sheet flow permitted), installation of utility laterals, and all other improvements necessary to comply with the Municipal Code and Public Works specifications, shall be filed with the Community Development Department. 27. Civil engineering plans shall include adjacent properties/structures, sewer laterals, and storm drain main lines on street. 28. Project construction shall protect private and public property in compliance with Sections 15.04.070 and 15.04.140. No work in the public right of way shall commence unless and until all necessary permits are attained from the Public Works Department including, if required, an approved residential or commercial encroachment permit. 29. Sewer manhole rim/lid elevations must be submitted prior to grading and plan check. 30. Sewer lateral video must be submitted with plan check submittal if the developer plans to use the existing sewer lateral. Sewer lateral work may be required after review Page 60 of 324 12 of the sewer lateral video. 31. The project must comply with Storm Water and Urban Runoff Pollution Control Regulations (HBMC Ch. 8.44). Implement required Low Impact Development Standards, provide calculations and documents i.e. Appendix D and E of the Storm Water LID Guidelines, submit at time of grading and plan check along with an erosion control plan. Section 3. Each of the above conditions is separately enforced, and if one of the conditions of approval is found to be invalid by a court of law, all the other conditions shall remain valid and enforceable. Section 4. Pursuant to the Code of Civil Procedure Section 1094.6, any legal challenge to the decision of the Planning Commission, after a formal appeal to the City Council, must be made within 90 days after the final decision by the City Council. PASSED, APPROVED, and ADOPTED on the 16th of December, 2025 VOTE: AYES: NOES: ABSTAIN: ABSENT: CERTIFICATION I hereby certify the foregoing Resolution P.C. 25-XX is a true and complete record of the action taken by the Planning Commission of the City of Hermosa Beach, California, at its regular meeting of December 16, 2025. Page 61 of 324 13 Kate Hirsch, Chairperson Alison Becker, Secretary Date Page 62 of 324 Paci f ic Coast Hwy Prospect A v e AUBREYPARK 8th StBonnie B rae St 15th St AubreyParkCt14th St OceanDrOwosso AvePierAv e 11th Pl Montgomery Dr 11th P l Aviation Blvd 11th St 10th St 11th St 9th St 10th St 7th St 8th Pl 9th St 8th StCoronaS t 13th St Zoning MapPlanning Commission Meeting December 16, 2025 1054 Aviation Blvd APN: 4186-001-020 Zone: C-3 General Commercial Precise Development Plan Description Legend R-1 Single Family Residential R-1A Limited Single-Family Residential R-2 Two Family Residential R-2B Limited Multiple Family Residential R-3 Multiple Family Residential R-P Residential-Professional RPD Residential Planned Development R-3PD Multiple Family Planned Development C-1 Neighborhood Commercial C-2 Downtown Commercial C-3 General Commercial M-1 Light Manufacturing OS Open Space OS-1 Restricted Open Space OS-2 Restricted Open Space OS-O Open Space Overlay MHP Mobile Home Park SPA Specific Plan Area (Residential) SPA Specific Plan Area (Commercial) -HE Housing Element Overlay 500' Notification Radius Page 63 of 324 DWG. NAME: 3D RENDERING - COVER TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 1054 AVIATIONHERMOSA BEACH, CA 90254HODGY’S TOY CHEST COVER9/18/2025 4:08:53 PMPage 64 of 324 1 2 4 5 6 1 2 4 5 6IA 1A 3 3 HODGY'S TOY CHEST 56 4 3 12 465 3 12IA 1A 1054 AVIATION BLVD.HERMOSA BEACH, CA 90254CONSULTANTSCIVIL SURVEY CONSULTANTSSHEET INDEXPROJECT DATAA-01PROPOSED SITE PLANDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL) A-02A-03PROPOSED BUILDING ELEVATIONSA-04HODGY’S TOY CHEST PROPERTY OWNERSCIVIL SURVEYA-05VICINITY MAPPROPOSED AREA CALCULATIONSA-00SYMBOL LEGENDABBREVIATION ABV.A.H.A.W.B.O.W.C.H.CLG.CLR.COL.CONC.C.W.DBL. CW.DIM.DN.ELEV.FLR.FX.HORZ.HT.LAND.LT.WT.MAX.MIN.O-X-OPLINE.REQD.SECT.S.F.E.SHT.SK.SL.T.O.W.ABOVEACTUAL HEIGHTAWNING WINDOWBOTTOM OF WALLCRITICAL HEIGHTCEILINGCLEARCOLUMNCONCRETECASEMENT WINDOWDOUBLE CASEMENT WINDOWDIMENSIONDOWNELEVATIONFLOORFIXEDHORIZONTALHEIGHTLANDINGLIGHT WEIGHT CONCRETEMAXIMUMMINIMUMFIXED OPERABLE FIXEDPROPERTY LINEREQUIREDSECTIONSUB FLOOR ELEVATIONSHEETSKEWEDSLOPEDTOP OF WALLDIFFERENTIAL IN FLOOR ELEVATION,FINISH SURFACE, OR CHANGE INWALL PLANLIGHT WEIGHT CONCRETEFLOOR ELEVATIONTOP/BOTTOM RISER# OF RISERS UP/DOWNDN. 0 R. @ 0"ROOM NAMESLOPE RUNSLOPE RISEEXTENTS OF REVISIONREVISION NUMBERNORTH ARROW DESIGNATIONSKYLIGHT LETTER DESIGNATIONDOOR NUMBER DESIGNATIONWINDOW LETTER DESIGNATIONSECTION NUMBERSHEET NUMBERA1ASURFACE DESCRIPTIONSLOPED SURFACE(ARROW POINTS DOWN SLOPE)ELEVATION DESIGNATIONSHEET NUMBERROOF SLOPE DESCRIPTIONELEVATIONELEVATIONFLOW LINE(ARROW POINTS DOWN SLOPE)SUB FLOOR ELEVATION / SLAB SUB-FLOOR ELEVATION / CEILING TYPEAROOF SLOPE4:12CBA-00DPUBLIC WORKS NOTES 1. ALL LANDSCAPE IRRIGATION BACKFLOW DEVICES MUST MEET CURRENT CITY REQUIREMENTS FORPROPER INSTALLATION.2. NO DISCHARGE OF CONSTRUCTION WASTEWATER, BUILDING MATERIALS, DEBRIS, OR SEDIMENTFROM THE SITE IS PERMITTED. NO REFUSE OF ANY KIND GENERATED ON A CONSTRUCTION SITE MAYBE DEPOSITED IN RESIDENTIAL, COMMERCIAL, OR PUBLIC REFUSE CONTAINERS AT ANY TIME. THEUTILIZATION OF WEEKLY REFUSE COLLECTION SERVICE BY THE CITY'S HAULER FOR ANY REFUSEGENERATED AT THE CONSTRUCTION SITE IS STRICTLY PROHIBITED. FULL DOCUMENTATION OF ALLMATERIALS/TRASH LANDFILLED AND RECYCLED MUST BE SUBMITTED TO THE PERMITS DIVISION INCOMPLIANCE OF THE CITY'S CONSTRUCTION AND DEMOLITION RECYCLING ORDINANCE.3. A PROPERTY LINE CLEANOUT MUST BE INSTALLED ON A 6" SANITARY SEWER LATERAL. IF THERE ISNO 6" SEWER LATERAL, THEN A NEW ONE MUST BE INSTALLED. THE SEWER LATERAL MUST STAY WITHIN THE JOB SITES PROPERTY LINES. SEE CITY STANDARD PLAN ST-5. CLEANOUT MUST BE ADDED TOTHE SITE PLAN.4. A BACKWATER VALVE IS REQUIRED ON THE SANITARY SEWER LATERAL IF THE DISCHARGES FROMFIXTURES WITH FLOOD LEVEL RIMS ARE LOCATED BELOW THE NEXT UPSTREAM MANHOLE COVER OFTHE PUBLIC SEWER. SEE CITY STANDARD PLAN ST-24. MUST BE SHOWN ON THE PLAN IF APPLICABLE.5. IF ANY EXISTING SEWER LATERAL IS USED, IT MUST BE TELEVISED TO CHECK ITS STRUCTURALINTEGRITY. THE TAPE MUST BE MADE AVAILABLE FOR REVIEW BY THE PUBLIC WORKS DEPARTMENT.THE PUBLIC WORKS DEPARTMENT WILL REVIEW THE TAPE AND DETERMINE AT THAT TIME IF THESANITARY LATERAL NEEDS REPAIRING, REPLACED, OR THAT IT IS STRUCTURALLY SOUND AND CAN BEUSED IN ITS PRESENT CONDITION.6. ANY UNUSED WATER OR SANITARY SEWER LATERALS MUST BE ABANDONED AT THE CITY MAIN.7. NOT USED.8. THE SIDEWALK MUST BE REPLACED FROM THE NORTH PROPERTY LINE TO THE SOUTH PROPERTY LINEAND SHOWN ON THE PLANS.9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL THE STREET SIGNS, STREETLAMPS/LIGHTS, PARKING METERS, AND OR TREES AROUND THE PROPERTY. IF THEY ARE DAMAGED,LOST OR REMOVED, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE THEM AT THECONTRACTOR'S EXPENSE. THE CONTRACTOR IS ALSO RESPONSIBLE FOR ANY STREET MARKINGSTHAT ARE DAMAGED OR REMOVED BY THE CONTRACTOR'S OPERATIONS. CONTACT THE PUBLICWORKS INSPECTOR FOR SIGN SPECIFICATION AND SUPPLIERS.10. THE BACK OF DRIVEWAY APPROACH MUST BE SIX INCHES HIGHER THAN THE FLOW LINE ON THESTREET.11. SIDEWALK, DRIVEWAY, CURB, AND GUTTER REPAIRS OR REPLACEMENT MUST BE COMPLETED PERPUBLIC WORKS SPECIFICATIONS. SEE CITY STANDARD PLANS ST-1, ST-2, AND ST-3. THE PLANSMUST HAVE A PROFILE OF THE DRIVEWAY, PERCENTAGE (%) OF SLOPE ON DRIVEWAY, AND DRIVEWAYELEVATIONS FOR EACH SIDE AND THE MIDDLE. IN THE CASE WHERE THE GARAGE LEVEL IS BELOW THESTREET DRAINAGE FLOW LINES, THE COMBINED SLOPE OF PUBLIC AND PRIVATE APPROACH SHALLNOT EXCEED 15%. IT SHALL BE THE DUTY OF EVERY PERSON CUTTING OR MAKING AN EXCAVATION ISMADE ACROSS ANY PUBLIC STREET, ALLEY OR SIDEWALK, ADEQUATE CROSSINGS SHALL BEMAINTAINED FOR VEHICLES AND FOR PEDESTRIANS.12. WATER METERS MUST REMAIN ACCESSIBLE FOR METER READERS DURING CONSTRUCTION. WATERMETERS SHALL BE PLACED NEAR THE PROPERTY LINE AND OUT OF THE DRIVEWAY APPROACHWHENEVER POSSIBLE. WATER METER PLACEMENT MUST BE SHOWN ON THE PLANS.13. THE WATER METER BOX MUST BE PURCHASED FROM THE CITY, AND MUST HAVE A TRAFFIC RATEDLID IF THE BOX IS LOCATED IN THE DRIVEWAY.14. IF ANY PARKWAY TREES ARE REMOVED, THEY MUST BE REPLACED WITH TREES SELECTED FROMTHE CITY'S APPROVED PARKWAY TREE LIST, AND PLANTED IN ROOT BARRIER BOXES.15. EROSION AND SEDIMENT CONTROL DEVICES BMPS (BEST MANAGEMENT PRACTICES) MUST BEIMPLEMENTED AROUND THE CONSTRUCTION SITE TO PREVENT DISCHARGES TO THE STREET ANDADJACENT PROPERTIES. BMPS MUST BE IDENTIFIED AND SHOWN ON THE PLAN. CONTROL MEASURESMUST ALSO BE TAKEN TO PREVENT STREET SURFACE WATER ENTERING THE SITE.16. ALL STORM WATER, NUISANCE WATER, ETC. DRAIN LINES INSTALLED WITHIN THE STREET RIGHT OFWAY MUST BE CONSTRUCTED OF DUCTILE IRON PIPE. DRAINS MUST BE SHOWN ON PLANS.17. ALL RUNOFF WATER FROM THE ROOF AND SIDE YARDS AND PATIOS MUST DISCHARGE ONTOGOULD AVENUE. DRAINS MUST BE SHOWN ON THE PLANS.18. PLAN HOLDER MUST HAVE THE PLANS RECHECKED AND STAMPED FOR APPROVAL BY THE PUBLICWORKS DEPARTMENT BEFORE THE BUILDING PERMIT IS ISSUED.PLANNING NOTES1. ALL BUILDING FEATURES PROJECTING INTO REQUIRED SETBACKS SHALL BE INDICATED ONSITE/PLOT PLAN.2. SEPARATE PERMITS AND PLANS ARE REQUIRED FOR SPAS, POOLS, SOLAR SYSTEMS,DEMOLITIONAND SEWER CAP OF EXISTING BUILDINGS. IF SUCH IMPROVEMENTS OR DEMOLITION IS REQUIREDAS A CONDITION OF APPROVAL FOR DISCRETIONARY ACTIONS OR TO COMMENCE BUILDING, THENSUCH PERMITS MUST BE OBTAINED BEFORE OR AT THE TIME THE PROPOSED BUILDING PERMIT ISISSUED.3. A WALL, FENCE OR HEDGE FORTY-TWO (42) INCHES IN HEIGHT MAY BE LOCATED AND MAINTAINEDON ANY PART OF A LOT. A FENCE, WALL OR HEDGE NOT MORE THAN SIX FEET IN HEIGHT MAY BELOCATED ANYWHERE ON THE LOT TO THE REAR OF THE REAR LINE OF THE REQUIRED FRONT YARD,PROVIDED THAT ON THE SIDE STREET LINE OF A CORNER LOT A FENCE, WALL OR HEDGE HIGHERTHAN FORTY-TWO (42) INCHES MAY EXTEND ONLY FROM THE REAR LOT LINE TO THE REAR LINE OFTHE REQUIRED SIDE YARD.4. BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN SUCH A POSITION AS TO BE PLAINLYVISIBLE AND LEGIBLE FROM THE STREET PER CRC SECTION 319 .1.5. A. NO PARKING SPACE FOR RESIDENTIAL USES WITHIN ANY BUILDING SHALL BE LESS THAN ANINSIDE DIMENSION OF EIGHT FEET, SIX INCHES WIDE OR LESS THAN TWENTY (20) FEET LONG. INRESIDENTIAL ZONES, GUEST PARKING SPACES LOCATED IN TANDEM BEHIND A REQUIRED PARKINGSPACE SHALL HAVE A MINIMUM LENGTH OF SEVENTEEN (17) FEET. GUEST PARKING SPACESSITUATED PARALLEL TO ALLEYS AND LOCATED BEHIND GARAGE DOORS WITH A NINE-FOOT SETBACKSHALL HAVE A MINIMUM LENGTH OF TWENTY-TWO (22) FEET.6. A 'CAPPED TEE' FITTING MUST BE INSTALLED OVER THE COLD WATER SUPPLY LINE ABOVE THEWATER HEATER FOR FUTURE SOLAR WATER HEATING. P&T RELIEF VALVE SHALL TERMINATE OUTSIDETHE BUILDING.7. ROUTE UNDERGROUND CONDUIT TO POWER POLE PER PUBLIC WORKS DEPARTMENT HANDOUTST-13. STUB OUT TO PROPERTY LINE FOR FUTURE UNDER-GROUNDING OF UTILITIES WHENAPPLICABLE.8. PROVIDE VISUAL SCREENING FOR PROPOSED MECHANICAL EQUIPMENT AND UTILITY METERS (TOPNEED NOT BE SCREENED IF LOCATED ON INTERIOR SIDE OF DWELLING).9. GAS AND ELECTRIC METERS MUST CLEAR PROPERTY LINES BY 3'-0".10. CONTRACTOR TO CHECK CITY RECORDS TO DETERMINE EXISTENCE OF CESSPOOL ON PROPERTY.IF THERE IS AN EXISTING CESSPOOL, IT MUST BE LOCATED AND THEN INSPECTED BY CITYPERSONNEL BEFORE DEMOLITION OR BUILDING PERMITS CAN BE ISSUED.11. A TREE REMOVAL PERMIT OR TREE PROTECTION PLAN MAY BE REQUIRED FOR THE REMOVAL ORPRESERVATION OF TREES (HBMC. 12.36.060).12. ALL UTILITY AND EQUIPMENT LOCATIONS, INCLUDING FIRE SPRINKLER CHECK VALVES, ELECTRICAND WATER METERS, UTILITY CABINETS, ETC. AND ANY REQUIRED PROTECTIVE POLES. (NOTE: CBCAND SCE REQUIRE THAT ELECTRIC BOXES MUST PROVIDE 3 FEET CLEAR TO ANY OBSTRUCTION,AND IF LOCATED ADJACENT TO A PARKING AREA PROTECTIVE BARRIERS 3 FEET AWAY FROM THEBOX IS REQUIRED. PROTECTIVE BARRIERS MAY NOT ENCROACH INTO THE REQUIRED PARKING ORVEHICLE MANEUVERING AREA.)MAXIMUM HEIGHT NOTEPARAPETS, SATELLITE ANTENNAE, RAILS, SKYLIGHTS, AND ROOFEQUIPMENT, MUST BE WITH THE MAXIMUM HEIGHT LIMIT.PROPOSED PROJECT INFORMATIONCOVERGENERAL NOTESCLIENT NAME: HODGY’S TOY CHESTPROJECT ADDRESS: 1054 AVIATION, HERMOSA BEACH, CA 90254TELEPHONE: (310) 955 7756EMAIL: - MGREENBERG@SKXMAIL.COMIT IS THE DESIGNER'S INTENTION IN THE CONTRACT DOCUMENTS TO COMMUNICATE THE PROJECTDESIGN AND TO FULFILL THE REQUIREMENTS AS SET BY APPLICABLE BUILDING CODES, ORDINANCES,AND REGULATIONS OF ALL GOVERNING AUTHORITIES HAVING JURISDICTION, IN A MANNERCOMMENSURATE TO THE STANDARDS OF THE PROFESSION. ANY ERRORS OR OMISSIONS REGARDINGDIMENSIONS AND/OR MATERIALS AND ASSEMBLIES SHOULD BE BROUGHT TO THE DESIGNER'SATTENTION IMMEDIATELY UPON DISCOVERY, ALLOWING THE DESIGNER TO ADDRESS THE ISSUE IN ATIMELY, PROFESSIONAL MANNER.1. 2022 CRC, 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGBS, 2022 CEES AND THE CITY OF`HERMOSA BEACH'2. AQMD NOTIFICATION IS REQUIRED 10 DAYS BEFORE BEGINNING ANY DEMOLITION WORK.REQUIRED FORM IS AVAILABLE AT THE COMMUNITY DEVELOPMENT DEPARTMENT. PROVIDE PROOFOF NOTIFICATION (MAIL WITH RETURN RECEIPT) 10 DAYS BEFORE BUILDING PERMIT IS ISSUED, ORCOMPLETE ASBESTOS NOTIFICATION WAIVER.3. SOILS REPORTS MUST MEET THE REQUIREMENTS OF CHAPTER 4 OF THE 2022 C.R.C. (NOTREQUIRED FOR THIS REMODEL PER CITY BUILDING OFFICIAL) - R401.4.1 GEO-TECHNICALEVALUATION. IN LIEU OF A COMPLETE GEO-TECHNICAL EVALUATION, THE LOAD-BEARING VALUES INTABLE R401.4.1 SHALL BE ASSUMED. (1500 PSF. FOR CLAY, SANDY SILTY CLAY, CLAYEY SILT, SILTAND SANDY SILT CLAY SOILS) .4. STUMPS AND ROOTS SHALL BE REMOVED TO A DEPTH OF 12" IN THE AREA OCCUPIED BY THEBUILDING.5. INSTALLATION OF INTERIOR AND EXTERIOR WALL AND CEILING COVERINGS SHALL CONFORM TOCHAPTER 7 OF 2016 CRC.6. "ALL NEW FIXTURES SHALL BE WATER CONSERVING. CPC 402.07. ALL HOSE BIBS MUST BE PROTECTED BY BACK FLOW PREVENTION AND HAVE AN ANTI-SIPHONDEVICE.8. PROVIDE APPROVED BACKWATER VALVE FOR ALL PLUMBING FIXTURES LOCATED BELOW THEELEVATION OF THE NEXT UPSTREAM MANHOLE COVER. FIXTURES ABOVE SUCH ELEVATION SHALLNOT DISCHARGE THROUGH THE BACKWATER VALVE. PROVIDE CAST IRON WASTE PIPING RISERS.9. ALL WINDOW COVERINGS REQUIRED BY CFIR. FORM SHALL BE POSTED PRIOR TO FINALINSPECTION.10. WRITTEN APPROVAL FROM THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD).(714) 396:2000 PER RULE 1403 FOR THE PROPER DISPOSAL OF ASBESTOS.11. ONLY LOS ANGELES COUNTY HEALTH DEPARTMENT APPROVED DEVICES MAY BE UTILIZED FORLANDSCAPE IRRIGATION BACK FLOW PREVENTION DEVICES.12. N/A13. PROVIDE DRIP PAN OR SIMILAR DEVICE FOR LAUNDRY ROOM, WATER HEATER, AND DISHWASHER.14. PROVIDE SURVEY STAKES PRIOR TO FOUNDATION INSPECTION TO VERIFY LOT LINES.15. THE DESIGNER IS NOT RESPONSIBLE FOR SITE GRADING OR DRAINAGE.16. IAPMO APPROVAL REQUIRED FOR ONE PIECE LAVATORY.17. POST INSULATION COMPLIANCE CARD IN CONSPICUOUS LOCATION IN DWELLING PRIOR TO FINALINSPECTION.18. IT IS THE GENERAL CONTRACTORS RESPONSIBLITY TO VERIFY THAT THE BUILDING IS WITHIN THEHEIGHT LIMIT PRIOR TO FRAMING THE ROOF RAFTERS. CONTACT THE CIVIL SURVEY CONSULTANTS.19. CONTROL VALVE FOR SHOWERS AND TUB/SHOWERS SHALL BE OF THE PRESSURE BALANCE ORTHERMOSTATIC MIXING VALVE TYPE. CPC. SECT. 418.020. VERIFY CLEARANCES WITH OVERHEAD UTILITY LINES FROM ALL PERMANENT AND TEMPORARYSTRUCTURE INCLUDING SCAFFOLDING AND OTHER WORKING AREAS DURING CONSTRUCTION.CLEARANCE TO BE 8 FT. HORIZONTAL AND 12 FT. VERTICAL. VERIFY WITH SOUTHERN CALIFORNIAEDISON CO. BEFORE COMMENCING CONSTRUCTION.21. SEPARATE PERMITS AND PLANS ARE REQUIRED FOR SPAS, POOLS, SOLAR SYSTEMS, DEMOLITIONAND SEWER CAP OF EXISTING BUILDINGS. IF SUCH IMPROVEMENTS OR DEMOLITION IS REQUIREDAS A CONDITION OF APPROVAL FOR DISCRETIONARY ACTIONS OR TO COMMENCE BUILDING, THENSUCH PERMITS MUST BE OBTAINED BEFORE OR AT THE TIME THIS PROPOSED BUILDING PERMIT ISISSUED.22. CRC. 309.7 - GARAGE DOOR EXTENSION SPRINGS SHALL BE FABRICATED FROM EITHER HANDDRAWN - SPRING WIRE (ASTM. A227-21)OR OIL-TEMPERED WIRE (ASTM. A229-71) AND INSULATEDIN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. (CBC. 1211)23. DESIGN STANDARDS. MINIMUM DESIGN STANDARD SHALL BE 9,000 CYCLES. (ONE CYCLE ISEQUAL TO DOOR OPENING PLUS DOOR CLOSING AT MAXIMUM WORKING LOAD). (CBC. 1211.2)24. PHYSICAL CYCLING TESTS OF EACH EXTENSION SPRING DESIGN AND CONTAINMENT DEVICESSHALL BE TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY. (CBC. 1211.3)25. EACH EXTENSION SPRING SHALL BE EQUIPPED WITH AN APPROVED DEVICE CAPABLE OFRESTRAINING THE SPRING OR ANY PART THEREOF IN THE EVENT IT BREAKS. (CBC. 1211.4)26. DUCTS PENETRATING WALL OR CEILING PENETRATIONS BETWEEN GARAGE AND DWELLING UNITSHALL BE CONSTRUCTED OF 26 GAUGE MINIMUM SHEET METAL AND SHALL HAVE NO OPENING INTOTHE GARAGE-PER SECT R302.5.2.27. ALL SITE DRAINAGE SHALL BE TERMINATED AT PUBLIC WAY VIA NON-EROSIVE DEVICE PER HBMC.28. "AS OF JULY 1, 2022, AN AUTOMATIC GARAGE DOOR BACKUP BATTERY IS REQUIRED ONNEW GARAGE DOOR OPENERS PER CALIFORNIA SENATE BILL 969.TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 S.F.E. / SLABXX.LT.WT.XX'NXX' SLAB / FLAT CLG.FAMILY ROOM12"DWG. NAME: PROPOSED PROJECT INFORMATIONCOVER AA-08DESIGNER OF RECORDPROPOSED MEZZANINE FLOOR PLANA-06FIXTURE FLOW RATES:ALL PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE FOLLOWING MAXIMUM FLOWRATES(EFF. JULY 1, 2018): (CGBSC 4.303.1)A. WATER CLOSETS: 1.28 GALLONS/FLUSHB. SHOWERHEADS - SINGLE: 1.8 GPM@ 80 PSIC. SHOWERHEADS - MULTIPLE: 1.8 GPM @ 80 PSI COMBINEDD. LAVATORY FAUCETS: 1.2 GPM @60 PSIE. KITCHEN FAUCETS: 1.5 GPM @60 PSIA-07PROPOSED STAIRCASE DETAILSA-08PROPOSED BUILDING SECTIONSPROPOSED SIGN LOCATION AND WALL ELEVATIONSAPPLICABLE CODESCITY, STATE, NATIONALLY2022 CBC, 2022 CMC, 2022 CPC, 2022 CEC, 2022 CGBS, 2022CEES AND SUMMARY OF RULES FOR EXPANSIONS AND ALTERATIONSTO NON-CONFORMING BUILDINGS AND USES (HERMOSA BEACHMUNICIPAL CODE (HBMC) CHAPTER 17.52) THE CITY OF `HERMOSABEACH'SEPARATE PERMITCONTRACTOR TO SUBMIT SEPARATE PERMIT APPLICATIONS FORDEMOLITION, FIRE SPRINKLER, HVAC, SIGNAGE.FIRE SPRINKLER SYSTEM PROVIDED SHALL COMPLY WITH NFPA 13D. FIRE SPRINKLER PLANS SHALL BESUBMITTED TO THE SPRINKLER PLAN CHECK UNIT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATIONIN ACCORDANCE WITH FIRE CODE 901.2A-09HARRY DESIGNS LLC (310) 714-13281623 6TH STREET,MANHATTAN BEACH, CA 90266HARRYDESIGNS@AOL.COMGEO TECHNICAL CONSULTANTSCIVIL ENGINEER FOR C-SHEETLOS ALAMITOS, CA. 9072010641 HUMBOLT STREETNORCAL ENGINEERING 562.799.9469PERU CONSULTANTS (310) 270-08115061 ROCKVALLEY ROAD,RANCHO PALOS VERDES, CA 90275C SHEET - TITLE SHEETC SHEET - DEMOLITION PLANC-1C SHEET - GRADING AND DRAINAGE PLANC-2C SHEET - PUBLIC IMPROVEMENTSC-3C SHEET - DETAILSC-4C SHEET - DRIVEWAY PROFILE AND SECTIONSC-5PROPOSED FIRST FLOOR PLAN3914 DEL AMO BLVD. SUITE 921TORRANCE, CA. 90503DENN ENGINEERS 310.542.94331. "ENCLOSED SPACE UNDER STAIRS THAT IS ACCESSED BY A DOOR OR ACCESS PANEL SHALL HAVEWALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH ½INCH GYPSUM BOARD. CRC R302.7"2. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS, AND SIMILAR FIXTURES SHALL BEMECHANICALLY VENTILATED IN ACCORDANCE WITH THE CRC R303.3.13. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIEDDIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACHSEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN ORSNOW. VENTILATION OPENINGS SHALL HAVE THE LEAST DIMENSION OF 1/16 INCH MINIMUM AND ¼INCH MAXIMUM. CRC R806.4. DOOR OPENING BETWEEN GARAGE AND DWELLING SHALL BE PROTECTED BY 1-3/8" THICK, TIGHTFITTING, SELF-CLOSING SOLID CORE WOOD DOOR OR A 1 3/4" THICK SELF-CLOSING HAVING A FIREPROTECTION RATING OF NOT LESS THAN 20 MINUTES. CRC R302.5.15. "SOIL ENGINEER TO INSPECT AND APPROVE FOUNDATION AND SUBMIT APPROVAL TO CITY, PRIORTO CITY INSPECTION."6. UFER GROUND REQUIRED IN FOOTING PER CALIFORNIA ELECTRIC CODE, ARTICLE 250-52(A)(3).7. "PROVIDE A LA COUNTY FIRE DEPARTMENT APPROVED AUTOMATIC SPRINKLER SYSTEMTHROUGHOUT THE STRUCTURE.P.C. NOTES:NPROPOSED ROOF PLANSUBJECT PROPERTYPROPOSED TRASH AND BATHROOM DETAILSA-10PROPOSED DEMO PLANA-11PROPOSED LANDSCAPE AND HARDSCAPE PLANA-02A3D RENDER1-3DC SHEET - EROSION CONTROL PLANC-6C-7FIRE SPRINKLER NOTES:PROJECT SUMMARY:PROJECT LOCATION: 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254LEGAL DESCRIPTION: TRACT NO 5826 (EX OF ST) LOT 3 AND ALL OF LOTS 4AND LOT 5ASSESSOR'S PARCEL #: 4186-001-020ZONING: C3OCCUPANCY: MCONSTRUCTION TYPE: VBNO. OF UNITS: 4 RETAIL STORESNO OF STORIES: RETAIL STORES + MEZZANINEFIRE SPRINKLER: YES - NFPA 13DSCOPE OF WORK:APPLICABLE AREAS OF WORK:DEMO OF EXISTING PET STORE AND BUILD 4 NEW RETAIL STORES(NON-MEDICAL).GENERAL BUILDING INFORMATIONGROSS BUILDING S.F. : 6487 S.F. (INCLUDES COMMON AREA AND MEZZANINE)NET BUILDING S.F. : 6301 S.F. (EXCLUDES COMMON AREA)COMMON AREA (TRASH, JANITOR'S OFFICE, UNISEX TOILET): 185 S.F.GROSS RETAIL AREAS (INCLUDES EXTERIOR AND HALFCOMMON INTERIOR WALLS )GROSS RETAIL SPACE 1: 1647 S.F.GROSS RETAIL SPACE 2: 1565 S.F.GROSS RETAIL SPACE 3: 1306 S.F.GROSS RETAIL SPACE 4: 897 S.F.MEZZANINE GROSS AREA: 886 S.F.TOTAL GROSS FLOOR AREA: 6301 S.F.NET RETAIL AREAS (EXCLUDING EXTERIOR ANDINTERIOR WALLS)NET S.F. RETAIL 1: 1558 S.F.NET S.F. RETAIL 2: 1478 S.F.NET S.F. RETAIL 3: 1216 S.F.NET S.F. RETAIL 4: 812 S.F.MEZZANINE AREA: 886 S.F.TOTAL NET RETAIL: 5950 S.F.ZONING INFORMATION REQUIRED PROVIDEDAREA:LOT AREA EXISTING: - 16,696 S.F.LOT COVERAGE MAX: 65% (10,852 S.F.) 33.54% (5601 S.F.)FLOOR AREA RATIO:FAR = 6301 / 16,696 (TOTAL GROSS FLOOR AREA/LOT AREA)FAR = 0.37YARDS:FRONT: 0'-0" MIN. 8'-8" ACTUALSIDE: 8'-0" MIN. 8'-0" VARIESSIDE STREET: 8'-0" MIN. 8'-0" VARIESREAR: 0'-0" 22'-8" ACTUALPARKING AND DRIVEWAYS:GROSS RETAIL AREA 6301 S.F.NUMBER OF SPACES: 1/250 S.F. 25 SPOTSADA SPOTS: 1/25 SPOTS 1 SPOTCOMPACT SPOTS (30% OF REQ'D): 8 SPOTS 8 SPOTSFULL PARKING SPOT DIMENSIONS : 8'-6" X 18'-0"ADA SPOT DIMENSIONS: 9'-0" X 18'-0"COMPACT SPOT DIMENSIONS: 7'-5" X 15'-0"PARALLEL SPOT DIMENSIONS: 8'-6" X 20'-0"9/18/2025 4:13:35 PMPage 65 of 324 886 S.F MEZZANINE STORAGE5415 S.F. TOTAL 897 S.F. RETAIL 4 1306 S.F. RETAIL 31565 S.F. RETAIL2 1647 S.F. RETAIL 1185 S.F.SERVICES157'-858"177'-034"NORTH5601 S.F. FOUNDATION FOOTPRINT3'-814"22'-6"17'-4" 78'-81 8"32'-834"50'-0"80'-618"111'-1"91'-1112"3'-112"40'-078" TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 A-00DWG. NAME: PROPOSED AREA CALCULATION 17.04.040 GENERAL DEFINITIONS."LOT COVERAGE" MEANS:A. THAT PORTION OF A LOT COVERED BY THE AREA WITHIN THE FOUNDATION OF THE MAIN BUILDINGAND ALL ACCESSORY BUILDINGS AND STRUCTURES,B. THE AREA COVERED BY CANTILEVERS PROJECTING FROM A BUILDING, ANDC. THE AREA COVERED BY DECKS AND STAIRS MORE THAN THIRTY (30) INCHES ABOVE GRADE ASTHAT TERM IS DEFINED IN SECTION 17.04.040.THE FOLLOWING SHALL NOT BE INCLUDED WHEN CALCULATING LOT COVERAGE:A. THE AREA COVERED BY ARCHITECTURAL PROJECTIONS, EAVES, AND UNENCLOSED BALCONIES (I.E.,BALCONIES OPEN ON AT LEAST TWO SIDES AND WHICH MAY BE UNDER ANOTHER BALCONY) THATPROJECT FIVE (5) FEET OR LESS FROM THE FACE OF A BUILDING,B. NON-STRUCTURAL STAIRS, PATIOS, WALKWAYS, AND PLANTERS WHICH ESTABLISH FINISH GRADE,ANDC. FENCES AND WALLS.SCALE: 3/32":12"MEZZANINE FLOOR PLANSCALE: 3/32":12"FIRST FLOOR PLANSCALE: 3/32":12"LOT COVERAGE PLANPROJECT SUMMARY:PROJECT LOCATION: 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254LEGAL DESCRIPTION: TRACT NO 5826 (EX OF ST) LOT 3 AND ALL OF LOTS 4 AND LOT 5ASSESSOR'S PARCEL #: 4186-001-020ZONING: C3OCCUPANCY: MCONSTRUCTION TYPE: VBNO. OF UNITS: 4 RETAIL STORESNO OF STORIES: RETAIL STORES + MEZZANINEFIRE SPRINKLER: YES - NFPA 13DSCOPE OF WORK:APPLICABLE AREAS OF WORK:DEMO OF EXISTING PET STORE AND BUILD 4 NEW RETAIL STORES (NON-MEDICAL).GENERAL BUILDING INFORMATIONGROSS BUILDING S.F. : 6487 S.F. (INCLUDES COMMON AREA AND MEZZANINE)NET BUILDING S.F. : 6301 S.F. (EXCLUDES COMMON AREA)COMMON AREA (TRASH, JANITOR'S OFFICE, UNISEX TOILET): 185 S.F.GROSS RETAIL AREAS (INCLUDES EXTERIOR AND HALFCOMMON INTERIOR WALLS )GROSS RETAIL SPACE 1: 1647 S.F.GROSS RETAIL SPACE 2: 1565 S.F.GROSS RETAIL SPACE 3: 1306 S.F.GROSS RETAIL SPACE 4: 897 S.F.MEZZANINE GROSS AREA: 886 S.F.TOTAL GROSS FLOOR AREA: 6301 S.F.NET RETAIL AREAS (EXCLUDING EXTERIOR AND INTERIOR WALLS)NET S.F. RETAIL 1: 1558 S.F.NET S.F. RETAIL 2: 1478 S.F.NET S.F. RETAIL 3: 1216 S.F.NET S.F. RETAIL 4: 812 S.F.MEZZANINE AREA: 886 S.F.TOTAL NET RETAIL: 5950 S.F.ZONING INFORMATION REQUIRED PROVIDEDAREA:LOT AREA EXISTING: - 16,696 S.F.LOT COVERAGE MAX: 65% (10,852 S.F.) 33.54% (5601 S.F.)YARDS:FRONT: 0'-0" MIN. 8'-8" ACTUALSIDE: 8'-0" MIN. 8'-0" VARIESSIDE STREET: 8'-0" MIN. 8'-0" VARIESREAR: 0'-0" 22'-8" ACTUALPARKING AND DRIVEWAYS:GROSS RETAIL AREA 6301 S.F.NUMBER OF SPACES: 1/250 S.F. 25 SPOTSADA SPOTS: 1/25 SPOTS 1 SPOTCOMPACT SPOTS (30% OF REQ'D): 8 SPOTS 7 SPOTSFULL PARKING SPOT DIMENSIONS : 8'-6" X 18'-0"ADA SPOT DIMENSIONS: 9'-0" X 18'-0"COMPACT SPOT DIMENSIONS: 7'-5" X 15'-0"PARALLEL SPOT DIMENSIONS: 8'-6" X 20'-0"9/18/2025 4:13:50 PMPage 66 of 324 TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 DWG. NAME: CIVIL SURVEYA-019/18/2025 4:13:53 PMPage 67 of 324 N 76°33'52"E177.06'N 42°15'22"W157.72'N 13°25'29"W78.87'N 13°25'29"W217.47'N 76°33'46"E349.98'N 47°49'44"E816.75'20.00'117.46'100.01'10TH STREET 40'20'80'40'40'ESTABLISHED PER TIES17.36'97.90'151.02150.67151.27156.82151.70152.44151.07GWGWPP150.74 TC150.24 FL150.37 EGSIGN150.29 BX1 5 0 .4 6 B X SIGN150.99151.65 TC151.17 FL151.27 EG151.78152.38FH152.35WV151.70WV150.24149.96149.61 FL149.36 EG149.93 EG149.77 FL150.26 TX149.47 BX149.24 BX149.46 TX148.97 FL149.15 EG150.01150.5612"PALM152.4012"PALM153.3212"PALM12"PALM155.28155.74155.67 TX155.09 FL154.37151.86152.61153.15 TC151.52 TC150.95 FL153.87 FL154.31 TX156.10 FL156.88158.23 TX158.43SIGN158.50158.10159.91160.83160.63160.54160.42 TX159.83 FL159.09158.18 TX157.60 FL156.13151.25152.02150.64 FL150.41 EG150.42151.33 TC150.25 TC149.75 FL149.90 EGSSMH150.26150.34 EG151.00 EG151.05 EG152.06 TC151.84 TX151.38 FL151.50 EG151.83 EG151.71 FL152.18 TX152.32 TX152.51152.426"PALM152.41249152.38152.28 TX151.76 FL151.49 FL151.63 EG152.2 PC152.25GRD POSTGRD POST151.81151.66 TX151.15 FLSSMHEL=151.13151.74151.67151.608"PALM151.616"PALM151.41151.38151.28 TC150.76 FL150.88 EG151.46151.39151.9815 4.68 T W158.63 TW152.76153.07153.81154.81161.64 TW6"PALM160.16160.56160.47161.27160.95161.02161.39164.79162.00164.64162.84162.39162.99162.88162.57160.89 TW160.22 TW159.57 TW159.13 TW163.55 TW164.28 TW164.24 TW163.59 TW158.49157.56 FLEXISTING RESIDENCEEXISTING RESIDENCECONC. SIDEWALK152.27152.00151.75151.56CONC. SWALECONC. SWALESIGN1 5 1.19 TX 150.67 FL RAMPCONC. GUTTERCONC.CONC.CONC. GUTTERCONC. DRIVEWAY 153.00HOUSE O/HFOUND WELL MON. PER R.S. 295-67FOUND S&W PER R.S. 249-10FITS L&T TANGENT TIESSTA.8+01.3332.17'32.16'#0817#0627SSMHEL=148.05#062637'± TO C/LSTA.8+30STA.9+91150.69 TX150.15 FL162.6 PC158.5 PC151.0 PC152.0 PC164.79 TWSET L&T LS 9321AT POINT OF INTERSECTIONTAG ELEV.=150.72'FOUND L&T LS 53441.00' W'LY OF CORNERON PROP. LINE PROD.TAG ELEV.=158.37'163.22 TWSET L&T LS 9321ON TOP OF BLK WALL3.25' NW'LY OF CORNERON E'LY PROP. LINETAG ELEV.=162.51'SET L&T LS 93211.00' NW'LY OF CORNERON PROP. LINE PROD.TAG ELEV.=152.12'ROOF 2176.00'MEZ SLAB166.58'SLAB153.50'POINT C158.50' PC.POINT B152.2' PC.P C.151.0'8'-6" X 18'-0"22FULL SPOTAVIATION BOULEVARD OWOSSO AVENUELINE OF ROOF ABOVELINE OF ROOF ABOVE LINE OF ROOF ABOVE LINE OF EXISTING BUILDING TO BE DEMOLISHED LINE OF EXISTING BUILDING TO BE DEMOLISHED LINE OF EXISTING BUILDING TO BE DEMOLISHED LINE OF EXISTING BUILDING TO BE DEMOLISHEDLINE OF EXISTING BUILDING TO BE DEMOLISHEDPOINT D162.60' PC.80'-618"BUILDING DEPTH60'-314"ADDITIONAL SETBACK22'-812"ACTUAL SETBACK(ZERO REQUIRED SETBACK)105'-1014"BUINDING WIDTH 26'-634"ACTUAL SETBACK9'-158"ACTUALSETBACK8'-2"ACTUALSETBACK8'-6"8'-6"8'-0"SETBACK8'-6"(TYPICAL)18'-0"13'-178" DRIVE AISLE 13'-10" 22'-812" SETBACK 48'-1"SETBACK8'-6" (TYPICAL)37'-1058"ACTUAL SETBACK28'-8"BUILDING DEPTH12'-258"ACTUAL SETBACK90'-078" BUILDING WIDTH 45°GATE BACKUPGC.L=97.45'R=757.34'=7°22'21"T=48.79'''''''''''''''''''''''''''''''''''''''''L=22.76'R=19.00'=68°37'34"T=12.97'''''''''''''''''''''''''''''''''''''''''8'-6" X 18'-0"18FULL SPOT8'-6" X 18'-0"19FULL SPOT8'-6" X 18'-0"20FULL SPOT8'-6" X 18'-0"21FULL SPOT8'-6" X 18'-0"14FULL SPOT8'-6" X 18'-0"13FULL SPOT8'-6" X 18'-0"2FULL SPOT8'-6" X 18'-0"4FULL SPOT8'-6" X 18'-0"5FULL SPOT20'CA-07A-07BA-07B A-07AA-07AROOF 1179.50'UP 3R.UP 4R.LINE OF ROOF ABOVE105'-1014"BUINDING WIDTH 14'-234"11'-314"DRIVE AISLE12'-6"29'-1134"EXISTING WALLTO REMAINEXISTING TREE TOBE REMAINNEW PLANTERADDED TO RETAINLEVELEXISTING WALLTO REMAINGATE BACKUPGC.153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP153.50 FF153.40 LIP151.85 FS153.40 FS151.90 INV153.30 FS153.35 FL153.35 FG153.30 FL150.80 FS153.30 FL153.30 FS155.00 FS156.25 FS156.33 FS153.40 FS(154.80)FS153.35 FS152.10 FS154.35 FS153.95 FS(155.80)FS153.40 FS(153.55)FS151.30 FS153.80 TW158.50 TW153.80 TW158.50 TW156.50 TW(154.20)FS(154.50)FS(154.20)FS153.80 FS(153.90)FS153.40 FS153.80 FGPOINT A151.5' PC. AVERAGE POINT A151.5' PC. AVERAGE EGRESSINGRESS8'-6" X 18'-0"23FULL SPOT8'-6" X 18'-0"FULL SPOT8'-6" X 18'-0"25FULL SPOT8'-6" X 18'-0"3FULL SPOT8'-6" X 18'-0"15FULL SPOT7'-6" X 15'-0"12COMPACT18'-0"8'-6"(TYPICAL)8'-6"8'-6"7'-6"8'-6"(TYPICAL)18'-0" 18'-0" 18'-0" 18'-0"8'-6"8'-6"8'-6"17'-0"8'-0"9'-0"18'-0"8'-6" X 15'-0"16COMPACT8'-6" X 18'-0"17FULL SPOT46'-0"ACTUAL SETBACK11'-338"SINGLEDRIVEWAY9'-0" X 18'-0"1ADA SPOT4'-0"15'-0"18'-0"2'-0"2'-0"18'-0"2'-0"18'-0"2'-0"CA-078'-0"14'-3"(11'-0" MIN. AISLE WIDTH)14'-334"(11'-0" MIN. AISLE WIDTH)11'-912"18'-0"15'-0"8'-6"18'-0"18'-0"18'-0"18'-0"7'-6" X 15'-0"11COMPACT7'-6" X 15'-0"10COMPACT7'-6" X 15'-0"9COMPACT7'-6" X 15'-0"8COMPACT7'-6" X 15'-0"7COMPACT7'-6" X 15'-0"6COMPACT1'-0"16'-978"(15'-0" MIN. AISLE WIDTH)158.50 TW155.42 FS155.00 FS154.80 FS153.40 FS154.75 FS156.50 TW153.70 FS12'-014"12'-018"12'-014"10'-714"10'-714" 10'-71 4" 10'-71 4" 10'-71 4" 10'-71 4"25'-0"(MIN. CLEAR BACKUP)19'-0"REDUCED BACKUP2'-0"18'-0"9'-0"23'-758"(C3 - ZONE)(R-2 ZONE)126'-338"PER ATTACHED ASSESSOR PARCEL MAPADDITIONAL 1'-0" WIDTHREDUCED BACK UP TO19'-0" INSTEAD OF 20'-0"PER NOTE# 5 OFPARKING HANDOUTDIMENSION A PER PARKINGHANDOUT REQUIREMENT12'-0" FOR FULL SPACE10'-6" FOR COMPACT SPACE11'-338"SINGLE DRIVEWAYWIDTH MIN. 9'-0"8'-6"1'-0"7'-6"1'-0"7'-6"7'-6"15'-0"15'-0"1'-0"45°7'-6"15'-0"7'-6"15'-0"7'-6"15'-0"7'-6"15'-0"FOR TURNING RADIUSSEE SHEET A-02DIMENSION A PER PARKINGHANDOUT REQUIREMENT12'-0" FOR FULL SPACE10'-6" FOR COMPACT SPACELANDSCAPELANDSCAPELANDSCAPELANDSCAPELANDSCAPE LANDSCAPE 8'-6" X 18'-0"228'-6" X 18'-0"18FULL SPOT8'-6" X 18'-0"19FULL SPOT8'-6" X 18'-0"208'-6" X 18'-0"218'-6" X 18'-0"14FULL SPOTFULL SPOT8'-6" X 18'-0"15FULL SPOT8'-6" X 15'-0"16COMPACT8'-6" X 18'-0"17FULL SPOT9'-0" X 18'-0"1ADA SPOT11'-338"R23'-0"R12'-0"11'-7" TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025PROPOSED SITE PLANDWG. NAME: PROPOSED SITE PLANSCALE: 1/8":12"NORTHA-02TURNING RADIUSSCALE: 1/8":12"9/18/2025 4:16:18 PMPage 68 of 324 EXISTING LANDSCAPE TO REMAIN - 462 S.F.98 SF. LANDSCAPE90 SF. LANDSCAPE 5601 SF. BUILDING FOOTPRINTAVIATION BOULEVARD OWOSSO AVENUE88 SF. LANDSCAPELOT SQUARE FOOTAGE: 16,696 S.F.BUILDING FOOT PRINT: 5601 S.F.NEW LANDSCAPING PROVIDED: 642 S.F.EXISTING LANDSCAPE : 462 S.F.LANDSCAPING SHALL NOT INTERFERE WITH SAFE SIGHT DISTANCES FOR VEHICULARTRAFFIC, THE VISION CLEARANCE IN SECTION 17.46.060, HEIGHT RESTRICTIONSFOR HEDGES IN 17.46.130, PEDESTRIAN OR BICYCLE WAYS, OR OVERHEAD UTILITYLINES OR LIGHTING.AN AUTOMATIC IRRIGATION SYSTEM USING EITHER EVAPOTRANSPIRATION OR SOILMOISTURE SENSOR DATA, WITH A RAIN SHUT-OFF SENSOR, SHALL BE INSTALLED.ALL IRRIGATION EMISSION DEVICES MUST MEET THE REQUIREMENTS SET IN THEAMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) STANDARD,AN IRRIGATION EFFICIENCY OF 0.75 FOR OVERHEAD SPRAY DEVICES AND 0.81FOR DRIP SYSTEMS SHALL BE USED FOR THE PURPOSE OF DETERMINING MAXIMUMAPPLIED WATER ALLOWANCE. IRRIGATION SYSTEMS SHALL BE DESIGNED,MAINTAINED, AND MANAGED TO MEET OR EXCEED THIS EFFICIENCY. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PREVENT WATER WASTE RESULTINGIN RUNOFF, OVERSPRAY, OR SIMILAR CONDITIONS WHERE IRRIGATION WATERPONDS OR FLOWS ONTO NON-IRRIGATED AREAS, WALKWAYS, SIDEWALKS, STREETS,ALLEYS, GUTTERS, STORM DRAINS, ADJACENT PROPERTY, OR SIMILAR UNTARGETEDAREAS. RUNOFF TO OTHER PERMEABLE OR IMPERMEABLE SURFACES SHALL NOT BEALLOWED.NARROW OR IRREGULARLY SHAPED AREAS, INCLUDING TURF LESS THAN EIGHT (8)FEET IN WIDTH IN ANY DIRECTION, SHALL BE IRRIGATED WITH SUBSURFACEIRRIGATION OR LOW VOLUME ABOVE-GROUND IRRIGATION SYSTEM.PLANTED AREAS SHALL BE COVERED WITH A MINIMUM OF THREE (3) INCHES OFORGANIC MULCH, EXCEPT IN AREAS COVERED BY GROUNDCOVERS OR WITHINTWENTY-FOUR (24) INCHES OF THE BASE OF A TREE, OR WHERE A REDUCEDAPPLICATION IS INDICATED. ADDITIONAL MULCH MATERIAL SHALL BE ADDED FROMTIME TO TIME AS NECESSARY TO MAINTAIN THE REQUIRED DEPTH OF MULCH.ALL IRRIGATION SYSTEMS SHALL PROVIDE BACKFLOW PREVENTION DEVICES INACCORDANCE WITH THE CURRENT EDITION OF THE CALIFORNIA BUILDING/PLUMBINGCODE AND CHECK VALVES AT THE LOW END OF IRRIGATION LINES TO PREVENTUNWANTED DRAINING OF IRRIGATION LINES.LANDSCAPE AND IRRIGATION MAINTENANCE.1. ALL LANDSCAPE AND RELATED ELEMENTS SHALL BE DESIGNED AND PROPERLYMAINTAINED TO INSURE LONG-TERM HEALTH AND SHALL MAINTAINCONFORMANCE WITH THE REQUIREMENTS OF THIS CHAPTER.2.IRRIGATION SCHEDULING SHALL BE REGULATED BY AUTOMATIC IRRIGATIONCONTROLLERS.3.WATERING HOURS AND DURATION SHALL BE SCHEDULED COMPLIANT WITH THEREQUIREMENTS OF CHAPTER 8.56.4.A REGULAR MAINTENANCE SCHEDULE SHALL INCLUDE, BUT NOT BE LIMITED TO,ROUTINE INSPECTION, ADJUSTMENT AND REPAIR OF THE IRRIGATION SYSTEM,AERATING AND DETHATCHING TURF AREAS, REPLENISHING MULCH, FERTILIZING,PRUNING, WEEDING AND REMOVING ANY OBSTRUCTION TO EMISSION DEVICES.5.REPAIR OF ALL IRRIGATION EQUIPMENT SHALL BE PROMPTLY UNDERTAKEN,USING THE ORIGINALLY INSTALLED COMPONENTS, OR EQUIVALENT ORENHANCED COMPONENTS COMPATIBLE WITH THE IRRIGATION SYSTEM.6.LANDSCAPE AREAS SHALL BE PERMANENTLY MAINTAINED AND KEPT FREE OFWEEDS, DEBRIS AND LITTER; PLANT MATERIALS SHALL BE MAINTAINED IN AHEALTHY GROWING CONDITION AND DISEASED OR DEAD PLANT MATERIALSSHALL BE REPLACED, IN KIND, PURSUANT TO THE APPROVED PLANS WITHINTHIRTY (30) DAYS. ALTERNATIVELY, DISEASED OR DEAD PLANT MATERIALS MAYBE REPLACED WITH PLANT MATERIALS THAT HAVE LOW WATER NEEDS, AS RATEDIN THE CURRENT EDITION OF THE WATER USE CLASSIFICATION OF LANDSCAPESPECIES.7.THE USE, STORAGE AND DISPOSAL OF ALL LANDSCAPE AND LAWN CAREPRODUCTS SHALL COMPLY WITH ALL MANUFACTURER'S SPECIFICATIONS ANDAPPLICABLE LAWS, AND MINIMIZE THE DISCHARGE OF POLLUTANTS TO THEENVIRONMENT.6BOTANICAL NAMESYMBOL6QUANTITYSIZEPLANTING LIST FOR SUNSET ZONE 24DYMONDIA MARGARATAECALIFORNIA POPPYENGLISH LAVENDERCALIFORNIA EVENING-PRIMOSE10WOOLY & COMMON YARROW16WUCOLSCLASSLLLLLHT. @MATURE±36"±12"±12"±8"94 SF. LANDSCAPE 6630 SF. PERVIOUS CONCRETE 31 03 SF. HARDS CAPE 45 SF. LANDSCAPE227 SF. LANDSCAPETEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025PROPOSED LANDSCAPE AND HARDSCAPE PLANDWG. NAME: PROP. LANDSCAPE AND HARDSCAPESCALE: 1/8":12"NORTHA-02A9/18/2025 4:16:21 PMPage 69 of 324 N 76°33'52"E177.06'N 42°15'22"W157.72'N 13°25'29"W78.87'N 13°25'29"W217.47'N 76°33'46"E349.98'N 47°49'44"E816.75'20.00'117.46'100.01'10TH STREET 40'20'80'40'40'ESTABLISHED PER TIES17.36'TO FOUND 2" IRON PIPE @ PROSPECT AVENUE PER PWFB 0617-3060,3061 97.90'151.02150.67151.27156.82151.70152.44151.07GWGWPP150.74 TC150.24 FL150.37 EGSIGN150.29 BX 15 0 .46 B X SIGN150.99151.65 TC 151.17 FL 151.27 EG151.78152.38FH152.35WV151.70WV150.24149.96149.61 FL149.36 EG149.93 EG149.77 FL150.26 TX149.47 BX149.24 BX149.46 TX148.97 FL149.15 EG150.01150.5612"PALM152.4012"PALM153.3212"PALM12"PALM155.28155.74155.67 TX155.09 FL154.37151.86152.61153.15 TC151.52 TC150.95 FL153.87 FL154.31 TX156.10 FL156.88158.23 TX158.43SIGN158.50158.10159.91160.83160.63160.54160.42 TX159.83 FL159.09158.18 TX157.60 FL156.13151.25152.02150.64 FL150.41 EG150.42151.33 TC150.25 TC149.75 FL149.90 EGSSMH150.26150.34 EG151.00 EG151.05 EG152.06 TC151.84 TX151.38 FL151.50 EG151.83 EG151.71 FL152.18 TX152.32 TX151.91 FL152.02 EG152.51152.01 EG151.86 FL152.40 TC152.426"PALM152.41152.49152.38152.28 TX151.76 FL151.49 FL151.63 EG152.2 PC152.25GRD POSTGRD POST151.81151.66 TX151.15 FLSSMHEL=151.13151.74151.67151.608"PALM151.616"PALM151.41151.38151.28 TC150.76 FL150.88 EG151.46151.39151.98154.68 T W158.63 TW152.76153.07153.81154.81161.64 TW6"PALM160.16160.56160.47161.27160.95161.02161.39164.79162.00164.64162.84162.39162.99162.88162.57160.89 TW160.22 TW159.57 TW159.13 TW163.55 TW164.28 TW164.24 TW163.59 TW158.49157.56 FLEXISTING RESIDENCEEXISTING RESIDENCECONC. SIDEWALK152.27152.00151.75151.56CONC. SWALECONC. SWALESIGN151.19 TX 1 50.6 7 FL CONC. GUTTERCONC.CONC.CONC. GUTTERCONC. DRIVEWAY153.00HOUSE O/HFOUND WELL MON. PER R.S. 295-67FOUND S&W PER R.S. 249-10FITS L&T TANGENT TIESSTA.8+01.3332.17'32.16'#0817#0627SSMHEL=148.05#062637'± TO C/LSTA.8+30STA.9+91150.69 TX150.15 FL162.6 PC158.5 PC151.0 PC152.0 PC164.79 TWSET L&T LS 9321AT POINT OF INTERSECTIONTAG ELEV.=150.72'FOUND L&T LS 53441.00' W'LY OF CORNERON PROP. LINE PROD.TAG ELEV.=158.37'163.22 TWSET L&T LS 9321ON TOP OF BLK WALL3.25' NW'LY OF CORNERON E'LY PROP. LINETAG ELEV.=162.51'SET L&T LS 93211.00' NW'LY OF CORNERON PROP. LINE PROD.TAG ELEV.=152.12'EXISTING LANDSCAPE TO REMAIN - 471 S.F. AVIATION BOULEVARD OWOSSO AVENUELINE OF EXISTING BUILDING TO BE DEMOLISHED LINE OF EXISTING BUILDING TO BE DEMOLISHED LINE OF EXISTING BUILDING TO BE DEMOLISHEDLINE OF EXISTING BUILDING TO BE DEMOLISHED20'-258"28'-438"31'-7"ACTUAL SETBACK 11'-612"ACTUAL SETBACK52'-434"BUILDING DEPTH14'-10"ACTUAL SETBACKL=97.45'R=757.34'=7°22'21"T=48.79'''''''''''''''''''''''''''''''''''''''''20'95'-112"24'-258"48'-718"BUILDING DEPTH88'-1078"95'-214"POND4765 S.F.BUILDING TODEMOLIOSHEDTO BE DEMOLISHED:EXISTING WALLS TO REMAIN:TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 DWG. NAME: PROPOSED DEMO PLANPROPOSED DEMO PLANSCALE: 1/8":12"NORTHA-039/18/2025 4:16:24 PMPage 70 of 324 9'-878"(AB-CP2)14'-812" EAVE TO PLINE 71'-934"EAVE TO PLINE1FLAT ROOF1FLAT ROOFPOINT C158.50' PC.POINT B152.2' PC.POINT D162.6' PC.POINT A151.5' PC. AVERAGE 111'-614" (LENGTH A-B) 22'-812" BUILDING TO PLINE157'-858"(LENGTH AB-CD)177'-034"(LENGTH C-D) 1 5 2 .2 P C 151.81158.501 5 2 .2 P C 158.49162.6 PC158.5 PC258" (A-AB) 21 8"(C-CDTO CP-1)91'-018"(LENGTH AB-CD)10'-434"(AB-CP1)34'-878" (A-AB) 89'-6" (C-CD TO CP2)ACT: 176.00'MAX: 182.30'CP-1119'-514"(LENGTH AB-CD)ACT: 179.50'MAX: 182.43'CP-256'-1078"BUILDING TO PLINE152.00 PC151.00 PC50'-414"EAVE TO PLINE52'-414"BUILDING TO PLINEAVIATION BOULEVARD OWOSSO AVENUEA-07CA-07CA-07BA-07B A-07AA-07A123456ABCDEF1AG1234561AABCDEFG46'-0"BUILDING TO PLINE (VARIES)44'-0"EAVE TO PLINE (VARIES)22334464'-0"EAVEROOF 2ROOF 1TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025PROPOSED ROOF PLANDWG. NAME: PROPOSED ROOF PLANSCALE: 1/8":12"NORTHA-049/18/2025 4:16:27 PMPage 71 of 324 1 5 2 .2 P C154.68 T W158.501 5 2 .2 P C 158.49151.56162.6 PC158.5 PCUP 21R.A-07CA-07CA-07BA-07B A-07AA-07A123456ABCDEF8'-0"SETBACK177'-034"157'-858"EXISTING LANDSCAPE TO REMAIN - 471 S.F.46'-0"BUILDING SETBACK46'-0"SETBACK48'-1"SETBACKAVIATION BOULEVARD OWOSSO AVENUE12'-258"ACTUAL SETBACK52'-734"1AGATE BACKUPGC.G90'-078"UP 3R.UP 4R.80'-618"9'-258"6'-838"11'-612"53'-058"14'-2"23'-10"32'-834"BUILDING DEPTH1234561AABCDEFG2A-111A-1022'-812" ACTUAL SETBACK 119'-5" 119'-5" 5'-0"NEW WALLS:EXISTING WALLS TO REMAIN:69'-434"ACTUAL SETBACK8'-134"ACTUALSETBACKRETAIL 4897 S.F. GROSS812 S.F. NETRETAIL 31306 S.F. GROSS1216 S.F. NETRETAIL 21565 S.F. GROSS1478 S.F. NETRETAIL 11647 S.F. GROSS1558 S.F. NETUT.3 YARD BIN4'X6'X(4'B-3'-9"F) 2-35 GALCARTS (O+R) TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025PROPOSED FIRST FLOOR PLANDWG. NAME: PROPOSED FIRST FLOOR PLANSCALE: 1/8":12"NORTHA-059/18/2025 4:16:30 PMPage 72 of 324 1 5 2 .2 P C154.68 T W158.501 5 2 .2 P C 158.49151.56162.6 PC158.5 PCEXISTING LANDSCAPE TO REMAIN - 471 S.F. AVIATION BOULEVARD OWOSSO AVENUEGATE BACKUPGC.OPEN TO BELOW16'-518"13'-378"47'-2"DN. 21R.MEZZANINE STORAGE886 S.F.A-07CA-07CA-07BA-07B A-07AA-07A8'-0"SETBACK177'-034"157'-858"46'-0"BUILDING SETBACK46'-0"SETBACK48'-1"SETBACK12'-258"ACTUAL SETBACK119'-5" 52'-734" 90'-078"80'-618"14'-2"23'-10"32'-834"BUILDING DEPTH8'-0"SETBACK177'-034"157'-858"46'-0"BUILDING SETBACK46'-0"SETBACK48'-1"SETBACK12'-258"ACTUAL SETBACK119'-5" 52'-734" 90'-078"80'-618"11'-612"53'-058"14'-2"23'-10"32'-834"BUILDING DEPTH123456ABCDEF1AG1234561AABCDEFG5'-0"NEW WALLS:EXISTING WALLS TO REMAIN:69'-434"ACTUAL SETBACK8'-134"ACTUALSETBACK15'-11"UTILITIES ROOFTEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 DWG. NAME: PROPOSED MEZZANINE FLOOR PLANPROPOSED MEZZANINE FLOOR PLANNORTHSCALE: 1/8":12"NORTHA-069/18/2025 4:16:33 PMPage 73 of 324 12'-0" 8'-0" DOOR HT. 7'-0" 1'-1" 5'-11" 20'-6"2'-0"EXIST158.5'EXIST156.13'EXIST151.75'PC.151.00'EXIST152.25'PC.152.20'SLAB153.50'MEZZ. S.F.E.166.53'EXIST151.00'EXIST151.39'EXIST151.45'EXIST151.81'TX.151.19'FL.151.19'PC.152.00'FL.149.77'TX.150.26'EXIST153.00'1245612456ACT: 176.00'MAX: 182.30'CP-1ACT: 179.50'MAX: 182.43'CP-2SLAB153.50'IA1A33ROOF 1179.50'ROOF 2176.00'MAX HT. AT CP2182.43'MAX HT. AT CP1182.30'HODGY'S TOY CHESTLINE OF PROPOSED GRADE ATBUILDING LINE12334578LINE OF EXISTING WALL AT NORTHPROPERTY LINELINE OF EXISTING WALKWAY GRADE20'-6"2'-0"1'-6" 1'-1" 6'-5"4'-6"12'-0"PC.151.00'EXIST151.75'EXIST152.00'EXIST152.44'EXIST153.00'EXIST156.13'PC.158.5'EXIST155.81'SLAB153.50'TC.150.74'FL.150.24'EXIST158.1'FDECBAFEDCBAACT: 176.00'MAX: 182.30'CP-1ACT: 179.50'MAX: 182.43'CP-2UTILITIES ROOF171.09'MEZZ. S.F.E.166.53'SLAB153.50'12'-0" GARAGE ROLL UP DOOR GG2'-0" 2'-0"ROOF 1179.50'ROOF 1179.50'ROOF 2176.00'LINE OF PROPOSED GRADE ATBUILDING LINE123536910LINE OF EXISTING WALL AT WESTPROPERTY LINELINE OF EXISTING GRADEEXIST159.91'12'-0" 1'-1" 5'-11"2'-0"5'-0" 8'-0" TRASH ROLL UP DOOR 12'-0" 1'-1" 4'-6"6'-5"2'-0"EXIST162'.6EXIST155.81'EXIST152.2'MEZZ. S.F.E.166.58'SLAB153.50'ABCDEFABCDEFMEZZ. S.F.E.166.58'UTILITIES ROOF171.09'SLAB153.50'MAX HT. AT CP2182.43'MAX HT. AT CP2182.43'GGROOF 1179.50'ROOF 1179.50'HODGY'S TOY CHESTLINE OF PROPOSED GRADE ATBUILDING LINE123489LINE OF EXISTING GRADELINE OF EXISTING WALL ATEAST PROPERTY LINEEXIST151.63'12'-0" 1'-1" 4'-6"1'-5"5'-0"2'-0" 8'-0" DOOR HT. 20'-6"2'-0"EXIST158.43'EXIST158.49'EXIST158.10'EXIST154.46'EXIST154.90'EXIST155.13'EXIST155.61'EXIST155.81'5MEZZ. S.F.E.166.53'SLAB153.50'64312465312SLAB153.50'UTILITIES ROOF171.09'IA1AMAX HT. AT CP2182.43'MAX HT. AT CP1182.30'ROOF 2176.00'ROOF 1179.50'LINE OF PROPOSEDGRADE AT BUILDING LINE123599118'-0" DOOR HT. 16'-6"2'-0"5'-6"LINE OF EXISTING WALL ATSOUTH PROPERTY LINELINE OF EXISTING GRADEAT PLANTER WALL BASEEXIST154.21'TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 DWG. NAME: PROPOSED BUILDING ELEVATIONS 3.2. PROVIDE #15 FELT PAPER AT ALL EXTERIOR WALLS PRIOR TO EXTERIOR FINISHES.PROVIDE TWO LAYERS OF #15 FELT PAPER OVER ALL EXTERIOR SHEAR WALLS. 1.STOREFRONT SYSTEM: VERTICAL PLANTER: EXTERIOR FINISH NOTESWOODEN POSTS: ROOFING:6"X12" THERMALLY TREATED WOOD COLUMNSNATURE SCREEN TRELLIS SYSTEM (SMT) - SINGLE MESH TRELLISSLATPANEL WOOD EFFECT EXTERIOR COMPOSITE SLAT WALL PANEL 7.56" X1.02" X 11.81".WOOD SLATS:1345678IMPERIAL MARQUEE AWNING WITH LATTICE TUBES 144" X 36"AWNING:STUCCO:STUCCO COLOR #2, 7/8" SMOOTH TROWEL FINISH STUCCO PLASTER OVER WIRELATH ATTACHED WITH 8d COOLER NAILS @ 6" O.C. OWNER TO SELECT COLOR.2FIBRE REINFORCED LIGHTWEIGHT CONCRETE 12” x 72” BOARD FORM FROMURBAN CONCRETE. INSTALL PER MANUFACTURERS SPECIFICATIONSIB ROOF SYSTEMS FOR FLAT ROOFS. MAX 1:12 SLOPE ICC ESR # 2852 CLASSA ROOFING. WATER & SLIP RESISTANT. SRI VALUE - 110THE ROOF VALLEY FLASHING SHALL BE PROVIDED OF NOT LESS THAN NO. 28 GALVANIZED SHEETGAUGE CORROSION-RESISTANT METAL, WHICH SHALL EXTEND AT LEAST 8" FROM THE CENTER LINEEACH WAY AND SHALL HAVE A SPLASH DIVERTER RIB NOT LESS THAN 3/4" HIGH AT THE FLOW LINEFORMED AS PART OF THE FLASHING. SECTIONS OF FLASHING SHALL HAVE AN END LAP OF NOT LESSTHAN 4". THE METAL VALLEY FLASHING SHALL HAVE A 36" WIDE UNDERLAYMENT DIRECTLY UNDER ITCONSISTING OF ONE LAYER OF TYPE 15 FELT RUNNING THE FULL LENGTH OF THE VALLEY, IN ADDITIONTO THE METAL VALLEY FLASHING UNDERLAYMENT SHALL BE SOLID CEMENTED TO THE ROOFINGUNDERLAYMENT FOR ROOF SLOPES UNDER 7" IN 12".WALL CLADDING:9COMMERCIAL HOLLOW METAL STEEL DOORS WITH NARROW LITE BY ARMORDOORS WITH PANIC HARDWARE.SOLID CORE DOOR:10SST-II HYDRAULIC BI-FOLD SYSTEMBI-FOLD GARAGE DOOR:KAWNEER’S TRIFAB® VERSAGLAZE® 450 FRAMING SYSTEM 1-3/4″ SIGHTLINESCALE: 1/8":12" PROPOSED NORTH ELEVATIONSCALE: 1/8":12" PROPOSED WEST ELEVATIONSCALE: 1/8":12" PROPOSED SOUTH ELEVATIONSCALE: 1/8":12" PROPOSED EAST ELEVATIONA-079/18/2025 4:16:36 PMPage 74 of 324 1245612456IA1A33HODGY'S TOY CHESTEXISTING WALL TO REMAINEXISTING WALL TO REMAINNEW TECH WOODMETAL FRAMINGWOODEN FENCEMETAL VERTICAL POST6'-0"41'-218"2'-5" 2'-614"43'-812"18" TALL METAL ILLUMINATEDBUILDING SIGN LOCATION16'-0"1'-6"FDECBAFEDCBAGGEXISTING WALL TO REMAINNEW WALL TO BECONSTRUCTEDNEW PLANTER WALL TO BECONSTRUCTED TO RETAINGRADEGATE BACKUPNEW TECH WOODMETAL FRAMINGEXIST159.91'TW158.50'TW153.80'2'-958" 4'-938" 3'-0" 3'-0"ABCDEFABCDEFGGHODGY'S TOY CHESTEXISTING WALL TO REMAINEXISTING WALL TO REMAINWOODEN FENCE5'-1114" 6'-912" 5'-718" 5'-418" 5'-514" 5'-1178" 6'-1"METAL VERTICAL POSTTW161.64'EXIST162.57'TW160.89'TW160.22'TW159.57'TW159.13'TW158.63'TW154.68'3'-6"2'-814"18" TALL METAL ILLUMINATEDBUILDING SIGN LOCATION16'-0"1'-6"564312465312IA1AEXISTING WALL TO REMAINEXISTING WALL TO REMAINEXIST159.91'EXIST162.57'TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025SCALE: 1/8":12" PROPOSED NORTH ELEVATIONSCALE: 1/8":12" PROPOSED WEST ELEVATIONSIGN LOCATIONS AND SITE WALL ELEVATIONS SCALE: 1/8":12" PROPOSED SOUTH ELEVATIONSCALE: 1/8":12" PROPOSED EAST ELEVATIONA. PERMITTED SIGNS. IN THE C-3 ZONE, ONLY THE FOLLOWING SIGNSSHALL BE PERMITTED PER SITE, SUBJECT TO THE PROVISIONS ANDREGULATIONS HEREINAFTER SET FORTH:1. BUSINESS SIGNS;2. BUILDING IDENTIFICATION SIGNS;3. ONE (1) REAL ESTATE SIGN;4. ONE (1) CONSTRUCTION SIGN;5. TEMPORARY SIGN(S);6. PERCENT OF ALLOWABLE SIGN AREA WHICH MAY BE USED FORCOMMODITY IDENTIFICATION:COMMODITY EQUAL TO LESS THAN TEN (10) PERCENT OF BUSINESS:TEN (10) PERCENTCOMMODITY EQUAL TO TEN (10) PERCENT TO FIFTY (50) PERCENT OFBUSINESS: TWENTY-FIVE (25) PERCENTCOMMODITY EQUAL TO MORE THAN FIFTY (50) PERCENT OF BUSINESS:SEVENTY-FIVE (75) PERCENTCOMMODITY IDENTIFICATION FOR BEVERAGES SOLD BY RESTAURANTSAND MARKETS: TEN (10) PERCENT7. PORTABLE A-FRAME SIGNS, AS SET FORTH IN SECTION 17.50.220.B. STYLES OF SIGNS. ONLY THE FOLLOWING STYLES OF SIGNS SHALL BEPERMITTED PER BUSINESS:1. ONE (1) WALL SIGN;2. ONE (1) GROUND SIGN, OR ONE (1) POLE SIGN PER SITE;3. ONE (1) AWNING SIGN;4. ONE (1) MARQUEE SIGN;5. WINDOW SIGN(S);6. BANNERS;7. MURAL (MURALS APPROVED BY THE COMMISSION MAY BE PERMITTED.IN ITS REVIEW THE COMMISSION MAY WAIVE SPECIFIC PROVISIONS OFTHIS CHAPTER RELATING TO TOTAL SIGN AREA, COVERAGE, HEIGHT,TYPE AND STYLE);8. PORTABLE A-FRAME SIGNS, AS SET FORTH IN SECTION 17.50.220.THESE SIGNS MAY BE ELECTRICAL, ILLUMINATED OR NEON, WITH THEEXCEPTION OF PORTABLE A-FRAME SIGNS, AS SET FORTH IN SECTION17.50.220.C. PROJECTION AND HEIGHT.1. WALL SIGNS SHALL NOT PROJECT MORE THAN SIX (6) INCHES FROMTHE WALL OF THE BUILDING OR STRUCTURE. ENDS OF THE SIGN MAYNOT BE USED FOR SIGN PURPOSES.2. ALL GROUND SIGNS SHALL BE LOCATED ENTIRELY ON PRIVATEPROPERTY AND CANNOT PROJECT OVER PUBLIC PROPERTY, AND SHALLNOT EXCEED TEN (10) FEET FROM GRADE TO THE HIGHEST PORTION OFTHE SIGN BODY WITH THE EXCEPTION OF PORTABLE AFRAME SIGNS,AS SET FORTH IN SECTION 17.50.220.D. ALLOWABLE SIGN AREA.1. TOTAL PERMANENT SIGN AREA SHALL NOT EXCEED THREE (3) SQUAREFEET FOR EACH FOOT OF LINEAL BUILDING FRONTAGE. BOTH SIDES OFA DOUBLE-FACED SIGN SHALL BE CALCULATED WHEN DETERMININGSIGN AREA.2. WHERE THERE IS MORE THAN ONE (1) BUSINESS OR ENTITY LOCATEDON ANY ONE (1) SITE, THE SIGN AREA SHALL BE CALCULATEDSEPARATELY FOR EACH ENTITY OR BUSINESS ACCORDING TO ITSAMOUNT OF BUILDING FRONTAGE.3. WHERE A BUSINESS OR ENTITY IS ABUTTED BY MORE THAN ONE (1)STREET, THE BUILDING FRONTAGE FOR SAID BUSINESS OR ENTITYSHALL BE THE SUM OF THE PRIMARY BUILDING FRONTAGE, PLUSONE-HALF (1/2) OF ANY SECONDARY BUILDING FRONTAGE,PROVIDEDTHE SECONDARY BUILDING FRONTAGE HAS A BUILDING ENTRANCE/EXITWHICH IS OPEN TO THE PUBLIC DURING BUSINESS HOURS FORCUSTOMER/PEDESTRIAN USE, WHICH ENTRANCE IS FRONTING ON ASTREET OR HIGHWAY. SIGN AREA GRANTED BY VIRTUE OF QUALIFIEDSECONDARY FRONTAGE MAY BE USED ON THE SECONDARY FRONTAGEONLY.4. NO SIGN SHALL COVER MORE THAN TWENTY-FIVE (25) PERCENT OFTHE WALL OR FASCIA IT OCCUPIES OR IS PLACED UPON.5. BUSINESSES FRONTING ONLY ON A PUBLIC/PRIVATE PARKING LOT,ALLEY OPEN MALL, LANDSCAPED OPEN SPACE OR OTHER PUBLIC WAYMAY USE THE BUILDING SIDE FACING SUCH PUBLIC WAY AS THEBUILDING FRONTAGE. ONLY ONE (1) SUCH BUILDING SIDE MAY BECONSIDERED BUILDING FRONTAGE.6. ALLOWABLE SIGN AREA FOR PORTABLE A-FRAME SIGNS SHALL BE ASSET FORTH IN SECTION 17.50.220.E.E, WINDOW SIGNS. WINDOW SIGNS SHALL BE ALLOWED IN THIS ZONEAND SHALL BE COUNTED IN THE TOTAL ALLOWABLE SIGN AREA, ANDSHALL NOT OBSCURE MORE THAN TWENTY (20) PERCENT OF THEGLASS SURFACE AREA OF THE WINDOW(S).F.F. SIGNS ABOVE THE FIRST STORY. SIGNS FOR BUSINESSES LOCATEDABOVE THE FIRST STORY MAY BE PROVIDED, BUT SHALL BE PART OFTHE TOTAL SIGN AREA ALLOCATION FOR THE CORRESPONDINGBUILDING FRONTAGE. THE MAXIMUM HEIGHT FOR UPPER STORY SIGNSSHALL BE TWENTY-EIGHT (28) FEET ABOVE THE ADJACENT STREETGRADE, OR THE UPPERMOST PORTION OF THE SECOND STORY,WHICHEVER IS HIGHER.G. POLE SIGNS. POLE SIGNS ARE PERMITTED BUT SHALL NOT EXCEED THEHEIGHT OF THE BUILDING ON THE SAME LOT, OR TWENTY (20) FEET INHEIGHT MEASURED FROM EXISTING GRADE, WHICHEVER IS LESSER,AND NO PART OF THE SIGN SHALL ENCROACH OR PROJECT WITHINFIVE (5) FEET OF ANY ADJACENT PRIVATE PROPERTY, OR ENCROACHOR PROJECT INTO THE PUBLIC RIGHT-OF-WAY. TO QUALIFY FOR APOLE SIGN, THE SITE MUST HAVE AT LEAST FORTY (40) FEET OFSTREET FRONTAGE. NO POLE SIGN MAY HAVE MORE THAN ONE SIGNCAN ATTACHED TO IT AND ALL POLE SIGNS SHALL INCORPORATE ARAISED LANDSCAPED PLANTER.A-089/18/2025 4:17:51 PMPage 75 of 324 12'-0" PLATE HT.1'-1" 12'-0" PLATE HT.11" 12'-0" PLATE HT. 1'-1" 4'-6" PARAPET 2'-0" EAVE RETAIL SPACE 1BCDEFBCDEFGGMEZZ. S.F.E.166.58'SLAB153.50'MEZZ. S.F.E.166.58'UTILITIES ROOF171.09'SLAB153.50'MAX HT. AT CP2182.43'MAX HT. AT CP2182.43'ROOF 1179.50'ROOF 1179.50'MEZZANINE STORAGE10'-0" MEZZANINE CEILING HT. 2'-0" TRUSS HT.UNISEXTRASH ENCLOSURE2'-0"EAVE2'-0"EAVEMECHANICAL DECK7'-0" DOOR HT. 8'-0" DOOR HT. 12'-0" DOOR HT. 8'-0" DOOR HT. 3'-0"8'-0"4'-0"BATHROOM20'-6"2'-0" 12'-0" PLATE HT. 10'-0" MEZZANINE CEILING HT. 12'-0" MEZZANINE CEILING HT. 1'-1" 8'-0" DOOR HT.SLAB153.50'MEZZ. S.F.E.166.53'12451245ACT: 176.00'MAX: 182.30'CP-1ACT: 179.80'MAX: 182.43'CP-2F.F.E153.50'IA1A33ROOF 1179.50'ROOF 2176.00'MAX HT. AT CP2182.43'MAX HT. AT CP1182.30'3'-6"MEZZANINE SUSPENDED BYPOSTS FROM BEAM IN ROOF20'-0" CEILING HT. 23'-1" CEILING HT. 8'-0" DOOR HT. 3'-0" TRANS. 8'-0" FIXED WINDOW 8'-0" DOOR HT. 3'-0" TRANS. 4'-6" 12'-0" DOOR HT. 12'-0"6'-5" 7'-0" 2'-0" 8'-0" DOOR HT. 2'-0"1'-6" 1'-1" 2'-0"11'-0"1'-0"8'-6"MAX HT. AT CP1182.30'MAX HT. AT CP1182.30'SLAB153.50'UTILITIES ROOF171.09'MEZZ. S.F.E.166.53'SLAB153.50'ROOF 1179.50'ROOF 1179.50'ROOF 2176.00'FDECBAFEDCBAGGOVERHANG165.50'1'-6" 20'-0" CEILING HT.2'-0"EAVE4'-0"EAVE3'-6" GUARDRAIL TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 SCALE: 1/8":12"PROPOSED SECTION AAMAXIMUM HEIGHT NOTEPARAPETS, SATELLITE ANTENNAE, RAILS, SKYLIGHTS, AND ROOFEQUIPMENT, MUST BE WITH THE MAXIMUM HEIGHT LIMIT.TITLE 24 ENERGY NOTES1. THE BUILDING DESIGN MEETS THE REQUIREMENTS OFCALIFORNIA CODE OF REGULATIONS, TITLE 24 PART 6.2. INSULATION INSTALLER SHALL POST IN A CONSPICUOUSLOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THEINSTALLER AND THE BUILDER STATING THAT THE INSTALLATIONCONFORMS WITH THE REQUIREMENTS OF TITLE 20,CHAPTER 2, SUBCHAPTER 4, ARTICLE 3.3. THE BUILDER SHALL PROVIDE THE ORIGINAL OCCUPANT A LISTOF THE HEATING, COOLING, WATER HEATING AND LIGHTING SYSTEMS ANDCONSERVATION OR SOLAR DEVICES INSTALLED IN THE BUILDING ANDINSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY.4. ALL PARTS OF THE DUCT SYSTEM SHALL BE TIGHTLY SEALEDWITH MASTIC OR TAPE.5. DUCTS SHALL BE INSULATED TO A MINIMUM INSTALLED VALUEOF R-4.2.6. CONTRACTOR SHALL POST THE INSTALLATION CERTIFICATE (CF-6R) FORMAND INSULATION CERTIFICATE (IC-1) FORM IN A CONSPICUOUS LOCATION OFKEPT WITH PLANS AND MADE AVAILABLE TO THE INSPECTOR.7. CONTRACTOR SHALL PROVIDE COPIES OF THE CALIFORNIA GUIDE TOHOME COMFORT AND ENERGY SAVINGS, CF-1R, MF-1R, CF-6R, AND IC-1FORMS TO THE BUILDING OWNER.8. AN APPROVED H.E.R.S. PROVIDER AND CERTIFIED RATER SHALL CONDUCTTHE FIELD VERIFICATION AND DIAGNOSTIC TESTING.9. CONTRACTOR SHALL PROVIDE A CERTIFICATE OF FIELD VERIFICATION ANDDIAGNOSTIC TESTING (CF-4R), SIGNED AND DATED BY THE HERS RATER TOTHE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION.10. WALL INSULATION SHALL HAVE A MINIMUM INSTALLED THERMALRESISTANCE OF R-19 IN 2X6 FRAMING SECTION 150.0(C)2.1. WHERE FINISH MATERIALS ARE APPLIED ON WALLS, CEILINGS ORSTRUCTURAL ELEMENTS REQUIRED TO HAVE A FIRE-RESISTANCE RATING ORTO BE OF NONCOMBUSTIBLE CONSTRUCTION, THEY SHALL COMPLY WITH THEREQUIREMENTS OF CBC 803.4.2. WALL, FLOOR AND CEILING SHALL NOT EXCEED THE FLAME SPREADCLASSIFICATIONS IN CBC T-803.5."3. INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS SHALL COMPLYWITH CBC 804.2 THROUGH 804.4.1.FINISH NOTESDWG. NAME: PROPOSED BUILDING SECTIONS SCALE: 1/8":12"PROPOSED SECTION BBSCALE: 1/8":12"PROPOSED SECTION CCA-099/18/2025 4:17:55 PMPage 76 of 324 TEL: 310-714 1328 MANHATTAN BEACH, CA 90266 1623 6TH STREETHODGY'S TOY CHESTDEMO OF EXISTING AND BUILD 4 RETAIL STORES (NON-MEDICAL)DESIGNER: HARRY DESIGNS LLCFOR: HODGY’S TOY CHEST 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254 TEL: (310) 955 7756 PC1: 03/10/2025 STAMPS PC2: 07/02/2025 LOCATED AT 1054 AVIATION BLVD., HERMOSA BEACH, CA 90254. PC3: 09/18/2025 DWG. NAME: MATERIAL BOARDSHT NO. COVERSCALE: N.T.S.MATERIAL BOARD9/18/2025 4:17:58 PMPage 77 of 324 Public Notification Packagre 1054 Aviation Boulevard Page 78 of 324 Page 79 of 324 Page 80 of 324 Page 81 of 324 City of Hermosa Beach PUBLIC HEARING NOTICE NOjlCE IS HEREBY GIVEN lllat the C):llil!J)lllSO!f of the He1T110sa Beach Planning Commission has calleih special public hearlng !>" TuOldllY, ~ember 16, 2(!25, at 5:00 p.m. to consldera~ take acllcn on on!y-those.maltetS·setfc>rth on'li,i,-a~enda beloYI. • 1. A PRECISE DEVELOF!MENT {!LAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REMODEL AND ADD TO AN EXISTING 1WO-STORY COMMERCIAL BUILDING. THE PROJECT ADDS A THIRD STORY WITH A HEIGHT OF 28 FEET 9.6 INCHES AND f!.EC00NFJGUBES THE EXI.STll:IG: BUILDING LAYOUT, RESULTING IN A REMODELED MWbTI-TENANT OOMME.RCIAL BUILDING, AT 901 HERMOSA AVENUE, IN THE DOWNTOWN COMMER€~(0.2fZONE. THE LOT LINE ADJUSTMENT CONSOLIDATES THREE EXISTING PARCELS INTO A SINGLE.LOT. CEQA: THE PROJECT QUALIFIES FOR A CLASS 1 CATEGORICAL EXEMPTION PER SECTION 15301 AND CLASS 5 CATEGORICAL EXEMPTION PER SECTION 5305 OF THE CEQA GUIDELINES. 2. A PRECISE DEVELOPMENT PLAN (PDP 25-01) FOR A NEW 6,487-SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING WITHA HEIGHT OP24 FEET AND 11 INCHES AND 25 PARKING SPACES, AT 1054AVIATION BOULEVARD, LOCATED WITHIN THE GENERAL COMMERCIAL ZONE (C-3). CEQA: THE PROJECT QUALIFIES FOR CLASS 3 CATEGORICAL EXEMPTION PER SECTION 15303 OF THE CEQA GUIDELINES. 3. A ZONE TEXT AMENDMENT AMENDING VARIOUS SECTIONS OF TITLE 17 OF THE HERMOSA BEACH MUNICIPAL CODE PERTAINING TO APPEAL PERIODS AND TRANSMISSION OF PLANNING COMMISSION'S RECORD TO CITY COUNCIL (CITYWIDE). CEQA: THE PROJECT IS EXEMPT FROM CEQAPER SECTION 15061(b) (3) OF THE CEQA GUIDELINES. 4. A ZONE TEXT AMENDMENT AMENDING HERMOSA BEACH MUNICIPAL CODE SECTION 17.08:020,(d) PERTAINING TO.HOME.OCCUPATIONS (CITYWIDE). CEQA: THE PROJECT IS,EXEMPT FROM CEOAPER SECTION 15061(b)(3) OF Tt-1E <;EQA GUIDELINES. SAID PUBLIC MEETING is open to the public and l:!i,be1!)9 held in-pe,son in the City Hall Council Chambers located at 1315 Vaney Drive, Hermosa Beac.h; ear11om;a·oo254. PUBLIC PARTICIPATION. Soo tho meeting agend!lfor an pllb)k: commen1 debails and oppo~nities. All written l~y by.any lnleresJed party will be accepte!I prior lo ~rat lffi!.scheduled ti~ on 1/ie·a~nda IDr•the matter. lnfonnation ll!gardlng the .Am<1ricans with OlsabUities Ad of 1990, please .\/istt the ~Hng agen\18 or contact the Office pf the City Cleft at (310J 318-0204 or cjtycie.rll@harmosabeach.goy. VIEWING OPTIONS are available on Spectrum Channel 8, Frontier Channel 31, YouTube, Zoom, and/or the City's website. IF YOU CHALLENGE the above-~Her(s) in court, you may be limited to raising only those Issues that are raised at or before the publlc hearing: - FOR•FURTHER INFORMATION, P,Jease 00fllaci th~ C_ommunlly O.Velopme(ll Oepar,mont at {310) 3!8-0242 ~r plann)ng@h"l'll'i¢a!lfa'1!J pow Aoopy,o/ ~ agenda and~~ i:.e1>ort!~) \'/Ill be viewable on··lhe City's we.bslle 72 hours·bero,e tlie'nleeling. As a aiilrtesy, (he hea/lng,c;a11 be viewed on Sr>edtum Channel 8, Frontier Channel 31 .,YooTube, Zoom, and/or,the City's webslle. AHson Becker, AICP Community OevelojitJ,enl Olrecior Easy Reader Inc/Redondo Beach News/December 4, 202S/H025-048 Page 82 of 324 1146607 6061210636 628 620 113911431161116711521135122311681164720 112711471157116311581154112611421160122912131211121812161205121512218081133115111551156925 9379649449481502 1435 1431 1421 1420 1436 1407 1430 10531401 14151400 14111416 1413 9289569139419499318578651291 1301 1044 1286 1292 1308 1322 1294 1302 1307 1315 1325 1326 1312 13061 0 9 7140312 0 0 1 2 2 2 1209 1103 1 4 02 845849915933900916 82783791984082584184392994694093091891290684483082281383590380190285092794381010398051032 103410131028715 711935923917911847829700 82195783994793810089269341018621 623 6351074102211051101 1132 1030 1024 1012 1006 112912031207120211241118111211411208920 914 908 1119 1121 1125113711221102111011161206120411401128114511531201854 828 1144113611301120848 842 834959955945867 901 103510491217 1219 1233 1235 1241 1255 1263 102910211214 1224 1228 1238 1260 1268 1280 1212 1220 1245 1249 1257 1265 10171063 12271231 12391243 1274 1264 1256 1250 1242 1230 12511253 123412321226122510751 0 8 5 1 0 8 9 10 9 31240 1 0 7 0 1 0 6 2 10 6 0 1 0 8 310771069 10031072111110151038101110411000 1036 939951950 90596094210421046909 100110271033104010161014100210761082107110651059105110261020101010041048105010521056106410091025104510551057831ProspectAve Aubrey Ct HollowellAveBonnie Brae St Joy StCampana StAubreyParkCt15th St OceanDrOwosso AveHarp e r A v e 14th St Montgomery Dr 13th St Aviation Blvd 10 th St 9 th St 11th Pl 7th St 11th St 7th Pl 8th Pl CoronaSt 9th St 8th St 8th St 1054 500' RADIUS MAP r1054 Aviation Blvd, Hermosa Beach, CA 90254 Page 83 of 324 Community Development Department Planning Division Attn: JC City of Hermosa Beach 1315 Valley Drive Hermosa Beach, CA 90254 IMPORTANT PUBLIC NOTICE 1054 Aviation Boulevard, Hermosa Beach, CA 90254 Assessor Parcel Numbers: 4186-001-020 NOTICE IS HEREBY GIVEN that the Planning Commission of the City of Hermosa Beach will hold a Public Hearing on Tuesday, December 16, 2025, at 5:00 p.m. to consider the request described below. A PRECISE DEVELOPMENT PLAN (PDP 25-01) FOR A NEW 6,487-SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING WITH A HEIGHT OF 24 FEET AND 11 INCHES AND 25 PARKING SPACES, AT 1054 AVIATION BOULEVARD, LOCATED WITHIN THE GENERAL COMMERCIAL ZONE (C-3). CEQA: THE PROJECT QUALIFIES FOR CLASS 3 CATEGORICAL EXEMPTION PER SECTION 15303 OF THE CEQA GUIDELINES. AMERICANS WITH DISABILITIES ACT OF 1990 To comply with the Americans with Disabilities Act of 1990, Assistive Listening Devices (ALD) are available for check out at the meeting. If you require special assistance to participate in this meeting, you must call or submit your request in writing to the Office of the City Clerk at (310) 318-0204 or at cityclerk@hermosabeach.gov at least 48 hours before the meeting. PARTICIPATION AND VIEWING OPTIONS - Hermosa Beach Planning Commission meetings are open to the public and are being held in person in the City Hall Council Chambers located at 1315 Valley Drive, Hermosa Beach, CA 90254. Public comment is only guaranteed to be taken in person at City Hall during the meeting or prior to the meeting by submitting an eComment for an item on the agenda. As a courtesy only, the public may view and participate on action items listed on the agenda via the following: Zoom - https://us02web.zoom.us/j/82539742028?pwd=ountrdnvd2l6tzbptdljc2x6bgfwdz09 Meeting ID: 825 3974 2028 Password: 207860 Phone - Toll Free: (833) 548-0276 Meeting ID: 825 3974 2028, then #; Passcode: 207860 eComment - Submit an eComment by 3:00 p.m. on the meeting date. Supplemental Email - Supplemental emails are available for agenda items only and must be sent to Community Development at planning@hermosabeach.gov. Supplemental emails should indicate the agenda item plus meeting date in the subject line and must be received by 3:00 p.m. on the meeting date. Emails received after the deadline but before the meeting ends will be posted to the agenda the next business day. Please be advised that while the City will endeavor to ensure remote participation methods are available, the City does not guarantee that they will be technically feasible or work all the time. Further, the City reserves the right to terminate these remote participation methods (subject to Brown Act restrictions) at any time and for whatever reason. Please attend in person or by submitting an eComment to ensure participation. Similarly, as a courtesy, the City will also broadcast the meeting via the following listed mediums. However, these are done as a courtesy only and not guaranteed to be technically feasible. To guarantee live time viewing and/or public participation, members of the public shall attend in Council Chambers. If you experience technical difficulties while viewing a meeting on any of our digital platforms, please try another viewing option. View staff reports and attachments at www.hermosabeach.gov/agenda. Cable TV - Spectrum (channel 8) and Frontier (channel 31) in Hermosa Beach YouTube - https://www.youtube.com/c/cityofhermosabeach90254 Live Stream - www.hermosabeach.gov/agenda Alison Becker, AICP, Community Development Director Page 84 of 324 NOTICES MAILED: 475 CITY OF HERMOSA BEACH AFFIDAVIT OF MAILING NOTICE STATE OF CALIFORNIA ) COUNTY OF ORANGE ) SS CITY OF SAN CLEMENTE ) AFFIDAVIT OF MAILING OF NOTICE I, Denise Kaspar, declare as follows: That I am an employee or representative of Advanced Listing Services Inc; that a copy of the Notice of Public Hearing for the City of Hermosa Beach in conjunction with the above-referenced meeting, was mailed to each and every person set forth on the attached list on December 3, 2025. A copy of said notice is attached. Said notice was completed by placing a copy of said notice with postage prepaid December 3, 2025 and depositing same in the outgoing mail at the Untied Postal Service located at Laguna Niguel, CA. I declare under the penalty of perjury that the foregoing is true and correct. Executed on December 3, 2025 at Dana Point CA. Printed: Denise Kaspar SUBJECT: 4186-001-020 HODGYS TOY CHEST LLC 1054 AVIATION BLVD HERMOSA BEACH CA 90254 Page 85 of 324 City of Hermosa Beach | Page 1 of 11 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-183 Honorable Chair and Members of the Hermosa Beach Planning Commission LOCATION: 901 HERMOSA AVENUE A PRECISE DEVELOPMENT PLAN AND LOT LINE ADJUSTMENT TO REMODEL AND ADD A THIRD STORY TO AN EXISTING COMMERCIAL BUILDING AT 901 HERMOSA AVENUE IN THE DOWNTOWN COMMERCIAL ZONE AND COASTAL ZONE CEQA: Determine the project is exempt from the California Environmental Quality Act. (Contract Planner Kaneca Pompey) Recommended Action: Staff recommends the Planning Commission: 1. Determine the project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to section 15301, class 1 and section 15305, class 5 of the CEQA guidelines. 2. Adopt a Resolution approving Precise Development Plan (PDP23-04) and Lot Line Adjustment (LLA 23-03) to remodel and add to an existing two-story commercial building that measures 12,012 square feet located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot, subject to conditions of approval (Attachment 1), including approval of a Coastal Development Permit by the California Coastal Commission. Executive Summary: This is a request for approval of a Precise Development Plan (PDP) and Lot Line Adjustment (LLA) to remodel and add to an existing two-story commercial building that measures 12,021 square feet. The project adds a third story with a height of 28 feet, 9.6 inches and reconfigures the existing building layout, resulting in a decrease of 194 square feet of usable floor area for a remodeled multi-tenant commercial building located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot. The Planning Commission considered this request at its October 21, 2025 meeting and continued the item to a date uncertain to give the applicant time to address questions and concerns raised during the meeting. Staff recommends that the Planning Commission approve the project subject to conditions of approval and determine that the project is categorically exempt from the California Environmental Quality Act. Page 86 of 324 City of Hermosa Beach | Page 2 of 11 Background: The project site is an existing 8,177-square-foot corner lot located in the southwestern portion of the City, between Ninth Street and Tenth Court and is adjacent to a walk-street. The site is designated Community Commercial (CC) in the General Plan and is zoned Downtown Commercial (C-3) (Attachment 2). The site is currently developed with a 12,021-square-foot two-story multi-tenant commercial building across three parcels. The current development has no surface parking. The site was developed in 1928. On October 21, 2025, the Planning Commission held a public hearing to consider the current application, at which time project-specific questions from Planning Commissioners remained unanswered (Attachment 6). To give the applicant and staff time to address these questions and concerns raised, the Planning Commission continued the item to a date uncertain. Since that time, staff have met with the applicant several times, including conducting a site visit. The applicant has provided revised plans (Attachment 3), 3D sectionals (Attachment 4), and a structural engineer letter (Attachment 5), which clarify building design. Past Board, Commission, and Council Actions Meeting Date Description October 21, 2025 Planning Commission holds a public hearing for a remodel and third story addition to an existing commercial building and continues the matter to a date uncertain. Site Information Table: The following table describes the existing site characteristics: Site Information General Plan Community Commercial (CC) Zoning General Commercial (C-2), Coastal Zone Lot Size 8,177 square feet Surrounding Zoning North: C-2 East: C-2 South: C-2 and R-2 (Two-Family Residential) West: R-2 Surrounding Uses North: Residential East: Restaurant South: Restaurant and Residential West: Residential Page 87 of 324 City of Hermosa Beach | Page 3 of 11 Authorization: Pursuant to HBMC Section§ 17.58.020, Precise Development Plan review is required for remodels of 1,500 square feet or more in any zone. Precise Development Plans shall be decided upon by the Planning Commission. Additionally, pursuant to HBMC Section 17.58.010 the purpose of Precise Development Plans is to ensure that new development supports the goals and objectives of the General Plan and other adopted plans and guidelines. The applicant proposes the interior and exterior remodel of a 12,012 square-foot two-story multi-tenant commercial building. Therefore, the project requires the approval of a Precise Development Plan. Project Description: The proposed project would renovate the existing 12,012 square-foot, two-story, multi- tenant building. The project would also include decommissioning approximately 1,340 square feet on the second floor and adding a 4,058 square-foot third story to the building for office use. The project would result in the square footage of the building increasing by 793 square feet. A transformer would be located in a 172 square-foot enclosed space on the first floor with access from a roll up door on 10th court. To comply with Southern California Edison guidelines, a 160 square-foot area on the second floor above the transformer will be clear and open. The property currently does not have a trash enclosure on site. The proposed project would include a trash room and loading room on the first floor both accessible from 10th Court. The project also includes a lot line adjustment to merge the three parcels the existing building is developed over into one parcel. Discussion: At the October 21st meeting the Planning Commission indicated a need for additional information on floor area of the existing and proposed building to better inform its deliberation on the request. Site/Floor plan: The applicant has submitted revised project plans to reflect the accurate floor area. The project proposes decreasing square footage on the first and second floors to accommodate the third-story addition. The proposed project would decrease the 7,653 square-foot first floor to 5,980 square feet and decrease the 4,359 square-foot second floor to 2,767 square feet. Overall, the project would also include decommissioning approximately 1,340 square feet on the second floor and adding a 4,058 square-foot third story to the building for office use. The project would result in the square footage of the building increasing by 793 square feet. Staff recommend a special condition of approval expressly prohibiting the use of this area without accounting for parking and would be walled off to prevent use of the area. Additionally, the transformer would be located in a 172 square-foot enclosed space on the first floor with access from a roll-up door on 10th Court. To comply with Southern California Edison guidelines, a 160 square-foot area on the second floor above the transformer will be kept clear and open. The property currently does not have a trash enclosure and incorporates a room for trash and recycling on the north side of the building that will be accessible from 10th Court. Page 88 of 324 City of Hermosa Beach | Page 4 of 11 October 21, 2025 Planning Commission Meeting: The Planning Commission raised questions regarding the floor plans, and indicated detailed assessment of the existing building floor area and new floor area was needed to better inform its deliberation. The following provides a discussion of the existing floor area: 1) Clarification on the existing floor area on record and the existing floor area the applicant has reported The Planning Commission raised concerns regarding potential discrepancies in the existing floor area reported by various sources. Since the public hearing, staff conducted a site visit and reviewed past permits and plans. Staff found inconsistencies between the second-floor square footage stated on the previous plans and the square footage approved by the City. The previous second-floor plan included movable floors and staircases, along with open areas as countable floor area in error. The existing building floor area for the first and second floors has now been revised to reflect a reduction in existing floor area from 14,021 square feet to 12,012 square feet. Figures 1 and 2 illustrate the corrected floor area; areas shaded in green, yellow, and blue are usable and permitted areas that count towards the existing floor area of the building. Areas shown in white were not counted towards the building floor area. Page 89 of 324 City of Hermosa Beach | Page 5 of 11 Figure 1. Diagram of Existing First Floor Figure 2. Diagram of Existing Second Floor 2) Countable Floor area Clarification The Planning Commission requested clarification on which areas were included in the floor area calculation and on the programming of the various spaces shown on the proposed building plan. Page 90 of 324 City of Hermosa Beach | Page 6 of 11 Pursuant to HBMC Section 174.44.010, the definition of gross floor area means the total area occupied by a building or structure, excepting therefrom only the area of any inner courts, exterior corridors, open balconies, open stairways, and designated garages. Such total area shall be calculated by measuring along the outside dimensions of the exterior surfaces of such building or the total of each floor level. Staff finds that certain utilitarian spaces, such as mechanical/utility rooms, elevators, stairways, and loading/parking areas should also be excluded, as these spaces do not contribute to the functional intensity of the building. In Figures 3 through 5, areas that have not been counted toward floor area appear in white. Figure 3. Diagram of Proposed First Floor Page 91 of 324 City of Hermosa Beach | Page 7 of 11 Figure 4. Diagram of Proposed Second Floor Figure 5. Diagram of Proposed Third Floor Page 92 of 324 City of Hermosa Beach | Page 8 of 11 3) Justification of the second-floor decommissioned area The Planning Commission questioned the reasoning for the decommissioned area and brought forward concerns that the area could be converted to usable space. The applicant has provided a letter (Attachment 5) from their structural engineer from Labib Funk and Associates justifying the need to keep the decommissioned area as it is structurally critical for seismic transfer of lateral forces to the lateral force resisting system. Parking/Loading The property currently has no off-street parking. Pursuant to HBMC Section 17.44.015, additions greater than ten (10) percent or 500 square feet, additional parking in accordance with this Chapter shall be provided for any alteration which would change the building square footage on site by more than ten (10) percent or 500 square feet, whichever is greater. The existing commercial building is 12,012 square feet. The project would include decommissioning approximately 1,340 square feet on the second floor and adding a 4,058 square foot third story. After accounting for the uninhabitable and utilitarian areas of the building, the proposed project would increase the square footage of the building by 793 square feet or six and a half percent. Therefore, the proposed project would not increase the usable square footage and would not require additional parking. Landscaping The project proposes a green roof and four raised gardens (see images below) on the third floor to be utilized as a visual aesthetic for the enjoyment of future tenants. The gardens would not be utilized or accessible by the tenants and is a visual amenity to the office spaces. Staff have added a condition of approval requiring maintenance of the gardens and green roof. Page 93 of 324 City of Hermosa Beach | Page 9 of 11 Figure 6. Proposed raised gardens (Third Floor Cross-Section) Findings: Pursuant to Hermosa Beach Municipal Code Section 17.58.020, remodels of 1,500 square feet or more in any zone shall be subject to a Precise development Plan (PDP). Pursuant to Hermosa Beach Municipal Code Section 17.58.040, all projects requiring a Precise Development plan must make the following findings to approve the PDP. 1. The design, layout, and other physical features of the project comply with all other applicable provisions of this Title and all other titles of the Hermosa Beach Municipal Code; 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; and 3. The design, layout, and other physical features of the project comply with any design or development standards applicable to the zone, unless waived or modified pursuant to the provisions of this Title. The third-floor gardens are intended as visual amenities; access to the space is provided for maintenance. The planter beds are raised and open to the sky. Page 94 of 324 City of Hermosa Beach | Page 10 of 11 After reviewing the revised plans and additional information, staff still recommends that the project meets the required findings for the approval of a Precise Development Plan as detailed in the draft resolution (Attachment 1). Additionally, Pursuant to the state Subdivision Map Act (California Government Code Section 66412(d)), a tentative map, parcel map, or final map shall not be required as a condition to the approval of a lot line adjustment between four or fewer existing adjoining parcels, where the land taken from one parcel is added to an adjoining parcel, and where a greater number of parcels than originally existed is not thereby created, if the lot line adjustment is approved by the City. Environmental Analysis: Pursuant to the California Environmental Quality Act (CEQA), the proposed project qualifies for a Class 1 categorical exemption, existing facilities as defined in section 15301 of the CEQA Guidelines, as it consists of internal and exterior modification of an existing building. The proposed project also qualifies for a Class 5 categorical exemption, minor alterations in land use limitations, as defined in Section 15305, as the project consists of a minor lot line adjustment. Additionally, a historic resource assessment was prepared for the project by Page & Turnbull in April 2024, and it was determined that the property is not considered a historic resource for the purposes of CEQA. Public Notification: For the December 16, 2025, Planning Commission hearing, a total of 694 public hearing notices were mailed to the applicant, occupants, and property owners of properties within a 500-foot radius on December 2, 2025. A legal ad was published on December 4, 2025, in the Daily Breeze, a newspaper of general circulation. Additionally, the applicant received a notice poster to post on-site and provided proof of posting a minimum of ten days in advance of the public hearing, in accordance with HBMC Section 17.68.050. Public notification materials are included as Attachment 7. As of the writing of the report, one public comment was received (Attachment 8). Attachments: 1. Resolution 25-XX 2. Zoning Map 3. Revised Plans 4. 3D Sections and Views 5. Structural Engineer Letter 6. October 21, 2025 Planning Commission Staff Report and Attachments 7. Public Notification Package 8. Public Comment Page 95 of 324 City of Hermosa Beach | Page 11 of 11 Respectfully Submitted by: Kaneca Pompey, Contract Planner Concur: Alexis Oropeza, Planning Manager Legal Review: Sarah Locklin, Interim Assistant City Attorney Approved: Alison Becker, Community Development Director Page 96 of 324 P a g e 1 of 13 CITY OF HERMOSA BEACH RESOLUTION NO. 25-XX A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, APPROVING A PRECISE DEVELOPMENT PLAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REMODEL AN EXISTING 12,012 SQUARE-FOOT TWO-STORY COMMERCIAL BUILDING AND CONSOLIDATE THREE EXISTING PARCELS INTO A SINGLE LOT AT 901 HERMOSA AVENUE, AND DETERMINING THAT THE PROJECT IS CATEGORICALLY EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) PURSUANT TO SECTION 15301, CLASS 1 AND SECTION 15305, CLASS 5 OF THE CEQA GUIDELINES. The Planning Commission of the City of Hermosa Beach does hereby resolve, and order as follows: WHEREAS, on May 30, 2023, the applicant, Kyle Ransford, filed an application for a Precise Development Plan and Lot Line Adjustment, to remodel and add to an existing 14,021 square-foot two-story commercial building (the “Project”) located at 901 Hermosa Avenue (the “site”). The project proposes to add a third story to the exiting building, increasing the building height to 28 feet 9.6 inches, and reconfigure the existing building layout, resulting in a decrease of 194 square feet of usable floor area for a remodeled multi-tenant commercial building. Additionally, the lot line adjustment will consolidate three existing parcels at the project site into a single lot; and WHEREAS, the Planning Commission, at its public meeting of October 21, 2025, conducted a public hearing, and continued the item to a date uncertain to give the applicant time to address questions and concerns raised during the meeting. At the October 21st meeting the Planning Commission indicated a need for additional information on floor area of the existing and proposed building to better inform its deliberation on the request. The applicant has submitted revised project plans to reflect the accurate floor area of 12,012 square feet; and WHEREAS, the Planning Commission, at its public meeting of December 16, 2025, conducted a public hearing, and considered all testimony and evidence, both oral and written, that was presented to the Planning Commission; and WHEREAS, the proposed project is Categorically Exempt from the California Environmental Quality Act as defined in section 15301, Class 1, Existing Facilities as the Page 97 of 324 P a g e 2 of 13 project consists of internal and exterior modification of an existing building. The proposed project also qualifies for a Class 5 categorical exemption, Minor Alterations in land use limitations, as defined in section 15305, as the project consists of a minor lot line adjustment. Additionally, a historic resource assessment was prepared for the project by Page & Turnbull in July 2024 and determined that the property is not considered a historical resource for the purposes of CEQA and will not cause a substantial adverse change in the significance of a historical resource, as per CEQA Guidelines (14 CCR § 15064.5(a)), 901 Hermosa Avenue is not currently listed in a local register of historic resources or in the California Register and is not eligible for listing in the California Register, the property is not a historic resource for the purposes of the CEQA. Moreover, none of the exceptions to the categorical exemption(s) apply under section 15300.2. The project is not located in a particularly sensitive environment such that its impact on the environment will be significant, and will not result in a significant cumulative impact of successive projects of the same type in the same place over time, or have a significant effect on the environment due to unusual circumstances. The project will not damage a scenic highway or scenic resources within a state scenic highway as no scenic state highway exist in the vicinity of the project, nor is the project located on a hazardous waste site. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. Based on the testimony and evidence received, the Planning Commission hereby further finds, determines, and declares the following pertaining to the application for a Precise Development Plan (PDP 23-04), pursuant to section 17.58.040 of the Hermosa Beach Municipal Code (“HBMC”): 1. The design, layout, and other physical features of the project comply with all other applicable provisions of this Title [Title 17, Zoning] and all other titles of the Hermosa Beach Municipal Code; The proposed project would renovate the existing 12,012-square-foot two-story multi-tenant building and would include decommissioning approximately 1,340 square feet on the second floor, adding a 4,058-square-foot third story to the building for office use, and would result in the square footage of the building decreasing by 194 square feet. A transformer would be located in a 172-square-foot enclosed space on the first floor with access from a roll up door on 10th court. To comply with Southern California Edison guidelines, a 160-square-foot area on the second floor above the transformer will be clear and open. The project has been reviewed for compliance, and the design, layout, and physical features of the proposed development would comply with all applicable provisions of the Municipal Code. Page 98 of 324 P a g e 3 of 13 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; The subject property has a General Plan land use designation of Community Commercial. The purpose of this designation is to provide opportunities and locations for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is also located within the Downtown District character area. The vision of this district is to enhance building form and orientation and maintain the pedestrian realm along Pier Avenue while transforming the realm on Hermosa Avenue. The Downtown District intended uses are services and activities associated with the local beach culture to residents as well as visitors to the city. Additionally, the Downtown character district areas specifies a desired character and building area form that includes 1) “many of the unique buildings, streetscape features, and public spaces are iconic or historic in nature, and new buildings should be carefully integrated to retain the town’s eclectic charm,” and 2) “buildings should be two to three stories in height, cover most or all of the parcel, and may abut neighboring structures.” The General Plan states the maximum floor area ratio (F.A.R.) for a community commercial land use designation is 1.25. The property is currently nonconforming with a FAR of 1.7, and the proposed project would maintain this nonconforming FAR. The proposed project would revitalize the existing building and incorporate a more modern aesthetic inclusive of a variety of materials to create interest and break monotony. The large arched storefront windows on the first floor would be maintained. The modern aesthetic would largely come into play in the new third floor addition with the installation of numerous windows and the incorporation of different materials. Additionally, staff proposes a condition of approval prohibiting tinting and reflective glass. Therefore, the proposed project is consistent with the General Plan. General Plan Consistency Goals & Policies Findings Land Use Element Goal 1: Create a sustainable urban form and land use patterns that support a robust economy and high-quality life for residents The proposed project will increase Page 99 of 324 P a g e 4 of 13 3. The design, layout, and other physical features of the project comply with any design or development standards applicable to the Zone, unless waived or modified pursuant to the provisions of this Title. The subject property has a Zoning Designation of Downton Commercial (C-2). The proposed project would renovate the existing 12,012-square-foot two-story multi-tenant building and would include decommissioning approximately 1,340 square feet on the second floor, adding a 4,058 square-foot third story to the building for office use, and would result in the square footage of the building decreasing by 194 square feet. The development proposes a contemporary architectural style and would utilize several materials, such as metal paneling, aluminum and glass on the storefront, and incorporate stucco, aluminum and glass curtain walls to break the monotony and create visual interest. The proposed design will be compatible with buildings in the surrounding area. Moreover, the project complies with all design development standards of the C-2 Zone. SECTION 2. Based on the testimony and evidence received, the Planning Commission hereby further finds, determines, and declares the following pertaining to the application for a Lot Line Adjustment (LLA 23-03) pursuant to the Subdivision Map Act, California Government Code Section 66412(d): Policy 1.3 Access to daily activities. Strive to create sustainable development patterns such that the majority of residents are within walking distance to a variety of neighborhood goods and services Policy 1.7 Compatibility of Uses. Ensure the placement of new uses does not create or exacerbate nuisances between different types of land uses. access to services in the community and contribute to more options for residents to have access to daily activities. All future uses will be subject to compliance with the permitted uses of the C-2 zone per the city’s municipal code. Parks & Open Space Element Goal 5. Scenic vistas, viewpoints, and resources are maintained or enhanced Policy 5.7 Light pollution. Preserve skyward nighttime views and lessen glare by minimizing lighting levels along the shoreline. Nighttime views would be protected by a condition of approval requiring all exterior lighting to be downcast to minimize light pollution. Page 100 of 324 P a g e 5 of 13 1. Pursuant to the state Subdivision Map Act (California Government Code Section 66412(d)), a tentative map, parcel map, or final map shall not be required as a condition to the approval of a lot line adjustment between four or fewer existing adjoining parcels, where the land taken from one parcel is added to an adjoining parcel, and where a greater number of parcels than originally existed is not thereby created, if the lot line adjustment is approved by the City. 2. The City must limit its review and approval to a determination of whether the parcels resulting from the adjustment will conform to the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances. Conditions and exactions placed on approval must be limited to those necessary to comply with the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances, to require the prepayment of real property taxes prior to the approval of the lot line adjustment, or to facilitate the relocation of existing utilities, infrastructure, or easements. In addition, the City cannot require a record of survey for a lot line adjustment unless otherwise required by law. The proposed lot line adjustment consolidates three existing lots into a single 8,177-square- foot lot (86 feet 2 inches wide by 95 feet) that is consistent with the General Plan, Zoning, applicable Coastal Plan, and building regulations. SECTION 3. Based on the foregoing, the Planning Commission hereby approves the subject Lot Line Adjustment (LLA 23-03) located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot as set forth in Planning Commission Resolution 25-XX, subject to the following Conditions of Approval: General Conditions 1. The subject property shall be developed, maintained, and operated in full compliance with the conditions of this permit and any law, statute, ordinance, or other regulation applicable to any development or activity on the subject property. Failure of the permittee to cease any development or activity not in full compliance shall be a violation of these conditions. 2. To the extent permitted by law, permittee shall defend, indemnify and hold harmless the City of Hermosa Beach, its City Council, its officers, employees and agents (the “indemnified parties”) from and against any claim, action, or proceeding brought by any party against the indemnified parties to attack, set aside, or void any permit or approval for this project authorized by the City, including (without limitation) reimbursing the City its actual attorney’s fees and costs in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of Page 101 of 324 P a g e 6 of 13 its choice. The permittee shall reimburse the City for any court and attorney's fees which the City may be required to pay as a result of any claim or action brought against the City because of this permit. Although the permittee is the real party in interest in an action, the City may, at its sole discretion, participate at its own expense in the defense of the action, but such participation shall not relieve the permittee of any obligation under this condition. 3. Each of the above conditions is separately enforced, and if one of the conditions of approval is found to be invalid by a court of law, all the other conditions shall remain valid and enforceable. 4. The property is located in the Coastal Zone. As such, California Coastal Commission project approval is required prior to submittal of the building plan check. A verbatim copy of the California Coastal Commission’s project approval along with any conditions of approval shall be incorporated into the plan check set of plans. Planning 5. Prepayment of all taxes as required California Government Code Section 66412 and any fees required by the City shall be evidenced prior to recordation of the Certificate of Compliance. 6. A Certificate of Compliance and legal descriptions in a form approved by the City and compliant with the Subdivision Map Act shall be submitted consistent with the plans approved by the Planning Commission, approved by the Community Development Director and City Attorney, and recorded with the Office of the Los Angeles County Recorder and evidence of recording shall be submitted to the Community Development Department within one (1) year of this approval. SECTION 4. Based on the foregoing, the Planning Commission hereby approves the subject Precise Development Plan (PDP 23-04) to remodel and add to an existing 12, 012- square-foot two-story commercial building located at 901 Hermosa Avenue, as set forth in Planning Commission Resolution 25-XX, subject to the following Conditions of Approval: General Conditions 1. The development and continued use of the property shall be in conformance with submitted plans received and reviewed by the Planning Commission at its meeting of October 21, 2025, in accordance with the conditions below. The Community Development Director may approve minor modifications that do not otherwise conflict with the HBMC or requirements of this approval. 2. The project shall fully comply with all requirements of the Downtown Commercial (C- 2) Zone as applicable of the Municipal Code, including but not limited to: Page 102 of 324 P a g e 7 of 13 a. Height, including all required roof-mounted equipment, shall fully comply with the 30-foot height limit. Precise building height compliance shall be reviewed at the time of the building plan review, to the satisfaction of the Community Development Director. b. Architectural treatments and accessory facilities shall be as shown on building elevations, site, and floor plans. 3. The project shall comply with all requirements of the City of Hermosa Beach Building Division, Public Works Department, Los Angeles County Fire Department, and the HBMC. 4. This approval shall not be effective for any purposes until the permittee, Kyle Ransford, and the owners of the property involved have filed at the office of the Planning Division of the Community Development Department signed affidavits stating that they are aware of, and agree to accept, all the conditions of this grant. The Precise Development Plan shall be recorded, and proof of recordation shall be submitted to the Community Development Department prior to the issuance of a building permit. 5. Approval of this permit shall expire twenty-four (24) months from the date of approval by the Planning Commission unless significant construction or improvements or the use authorized hereby has commenced. One or more extensions of time may be requested. No extension shall be considered unless requested, in writing to the Community Development Director including the reason therefore, at least 60 days prior to the expiration date. No additional notice of expiration shall be provided. 6. The Planning Commission may review this Precise Development Plan and may amend the subject conditions or impose any new conditions deemed necessary to mitigate detrimental effects on the surrounding neighborhood. 7. The subject property shall be developed, maintained, and operated in full compliance with the conditions of this permit and any law, statute, ordinance, or other regulation applicable to any development or activity on the subject property. Failure of the permittee to cease any development or activity not in full compliance shall be a violation of these conditions. 8. To the extent permitted by law, permittee shall defend, indemnify and hold harmless the City of Hermosa Beach, its City Council, its officers, employees and agents (the “indemnified parties”) from and against any claim, action, or proceeding brought by any party against the indemnified parties to attack, set aside, or void any permit or approval for this project authorized by the City, including (without limitation) reimbursing the City its actual attorney’s fees and costs in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. The permittee shall reimburse the City for any court and attorney's fees which the City may be required to pay as a result of any claim or action brought Page 103 of 324 P a g e 8 of 13 against the City because of this permit. Although the permittee is the real party in interest in an action, the City may, at its sole discretion, participate at its own expense in the defense of the action, but such participation shall not relieve the permittee of any obligation under this condition. 9. Each of the above conditions is separately enforced, and if one of the conditions of approval is found to be invalid by a court of law, all the other conditions shall remain valid and enforceable. Planning 10. All Conditions of Approval shall be printed verbatim on all plans submitted for plan review to the Community Development Department. These conditions shall be indexed on the cover sheet and referenced on the site plan. 11. The property is located in the Coastal Zone. As such, California Coastal Commission project approval is required prior to submittal of the building plan check. A verbatim copy of the California Coastal Commission’s project approval along with any conditions of approval shall be incorporated into the plan check set of plans. 12. Floor Plans: The floor plans shall be maintained and used in accordance with the floor plans incorporated as Exhibit A of this Resolution. Any revision to the floor plan configuration shall be reviewed and approved by the Planning Commission. Minor changes that do not materially change the project may be approved by the Community Development Director. 13. Landscaping: All landscaped areas shall maintained and shall be strictly prohibited from use without approval of a modification to the approved Precise Development Plan by the Planning Commission. 14. Landscaping: Any proposed onsite landscaping shall comply with HBMC chapter 8.60, Water Efficient Landscaping and HBMC section 8.44.095(F)(1) and must be submitted to the Community Development Department and be approved prior to issuance of the building permit. 15. Walls/Fences: All walls, or fences, including the visible surface of retaining walls, shall be constructed of, or treated with, an aesthetically pleasing material approved by the Community Development Director, including, but not limited to, masonry block designed and manufactured to be exposed (e.g., split-face, scored, textured or striated); surface treated masonry (e.g. stucco or paint); wrought iron or simulated wrought iron; brick; wood; stucco or paint. Plain gray untreated block not designed or manufactured to be exposed and chain link fences are prohibited (HBMC Section 17.46.130.E). 16. Lighting: Outdoor lighting and lighting for signs associated with commercial uses designed so as not to adversely impact residences. No flashing, blinking, or high- Page 104 of 324 P a g e 9 of 13 intensity lighting. Adequate lighting to illuminate parking areas and corridors to access parking and public sidewalk. Lighting for signs may only be illuminated during business hours. 17. Lighting: All lighting shall be directed downward, fully shielded and illumination shall be contained within the property boundaries. Lighting shall be energy conserving and motion detector lighting shall be used for all lighting except low-level (3 feet or less in height) securing lighting and porch lights. Exterior lighting shall not be deemed finally approved until 30 days after installation, during which period the building official may order the dimming or modification of any illumination found to be excessively brilliant or impacting to nearby properties. 18. Signs: Signs shall be limited to the commercial space frontage pursuant to the requirements of HBMC Chapter 17.50, Signs. 19. All proposed mechanical equipment shall be located outside of required setbacks in accordance with the Hermosa Beach Municipal Code. All mechanical equipment must be screened from public view subject to the review and approval of the Community Development Director or designee. 20. Use of the second-floor decommissioned area shall be strictly prohibited from use. 21. At the time of plan check approval, the applicant shall submit a building permit. The applicant shall remit a construction plan, which shall include a plan for how it will maintain\the existing perimeter walls throughout the various construction phases. 22. Window Treatments. Reflective window tints shall be prohibited on all windows. The ground floor street-facing windows shall provide a minimum visible light transparency transmittance level of 50 percent. 23. Construction projects within the city shall demonstrate compliance with all applicable standards of the Southern California Air Quality Management District, including the following provisions of District Rule 403: · All unpaved demolition and construction areas shall be wetted at least twice daily during excavation and construction, and temporary dust covers shall be used to reduce dust emissions and meet SCAQMD Rule 403. Wetting could reduce fugitive dust by as much as 50 percent. · The construction area shall be kept sufficiently dampened to control dust caused by grading and hauling, and at all times provide reasonable control of dust caused by wind. · All clearing, earth moving, or excavation activities shall be discontinued during periods of high winds (i.e., greater than 15 mph), to prevent excessive amounts of dust. · All dirt/soil loads shall be secured by trimming, watering, or other appropriate Page 105 of 324 P a g e 10 of 13 means to prevent spillage and dust. · All dirt/soil materials transported off-site shall be required to cover their loads as required by California Vehicle Code Section 23114 to prevent excessive amount of dust. · General contractors shall maintain and operate construction equipment to minimize exhaust emissions. · Trucks having no current hauling activity shall not idle but shall be turned off. 24. In accordance with Section 2485 in Title 13 of the California Code of Regulations, the idling of all diesel-fueled commercial vehicles (weighing over 10,000 pounds) during construction shall be limited to 5 minutes at any location. 25. The project shall comply with South Coast Air Quality Management District Rule 1113, limiting the volatile organic compound content of architectural coatings. 26. Construction projects within the city shall install odor-reducing equipment in accordance with South Coast Air Quality Management District Rule 1138. 27. Project applicants shall identify all measures to reduce air pollutant emissions below SCAQMD thresholds prior to the issuance of building permits. Should attainment of SCAQMD thresholds be determined to be infeasible, construction contractors shall provide evidence of this to the City and will be encouraged to apply for SCAQMD SOON funds. 28. As a standard condition of approval for future development projects implemented under PLAN Hermosa that involve ground disturbance or excavation: · For any project where earthmoving or ground disturbance activities are proposed at depths that encounter older Quaternary terrace deposits, a qualified paleontologist shall be present during excavation or earthmoving activities. · If paleontological resources are discovered during earthmoving activities, the construction crew shall immediately cease work in the vicinity of the find and notify the City. The project applicant(s) shall retain a qualified paleontologist to evaluate the resource and prepare a recovery plan in accordance with Society of Vertebrate Paleontology guidelines (1996). The recovery plan may include, but is not limited to, a field survey, construction monitoring, sampling and data recovery procedures, museum storage coordination for any specimen recovered, and a report of findings. Recommendations in the recovery plan that are determined by the lead agency to be necessary and feasible shall be implemented before construction activities can resume at the site where the paleontological resources were discovered. Page 106 of 324 P a g e 11 of 13 Building 29. The previously provided LFA Report dated 10/8/24 states that the existing wall will not be entirely abandoned and that alterations will be made to mitigate structural deficiencies. Structural plans have not yet been reviewed to determine the extent of this work and how it may encroach into the PROW. No new walls or foundation footings (including underpinning) will be allowed within the public right-of-way without the approval of Public Works. 30. Must reference all gross square footage on page G-202, to include square footage that is being designated and labeled as “deactivated space”. 31. Must clarify access areas on page G-202/G-203/G-204: a. It appears that the access path to the proposed electrical room is less than 3 feet. b. The South egress path and door swing appear to swing out onto the encroachment area, subject to the approval of Public Works. c. The doors on the North side of the building for the proposed fire room and trash room appear to swing into the public right of way, subject to the approval of Public Works. 32. Must acquire approval from Public Works if the existing wall encroaching on the Public Way is to be maintained in that location. 33. Referencing page AD-111: Any work that exceeds 50% demolition of the existing framing will be considered new and is subject to the development and building standards of a new building. The following items will require plan review and approval, prior to permit issuance: 34. Pedestrian and adjacent property protection plans will be required for review and approval. 35. Submit all Architectural, Geotechnical Reports, LID, Site Drainage, Energy Sheets/Calculations, and Structural Plans for plan review and approval and acquire all required permits. 36. Submittal and plan approval required to LA County Fire Land Development Unit for the site plans and floor plans 37. Submittal and plan approval required to LA County Fire for Fire Sprinklers and Fire Alarm Systems. Public Works 38. No new walls or foundation footing will be allowed to be constructed on or over the Page 107 of 324 P a g e 12 of 13 public right-of-way. 39. A Residential Encroachment permit is required for non-confirming structures located over or within the public right-of-way. The following conditions of approval shall be satisfied, subject to the satisfaction of the Public Works Director or designee. 40. Prior to issuance of a Building Permit, an approved civil engineering plans prepared by a licensed civil engineer, and approved by Public Works, addressing grading, undergrounding of all utilities, pavement, sidewalk, curb and gutter improvements, on-site and off-site drainage (no sheet flow permitted), installation of utility laterals, and all other improvements necessary to comply with the Municipal Code and Public Works specifications, shall be filed with the CD Department. 41. Civil engineering plans shall include adjacent properties/structures, sewer laterals, and storm drain main lines on the street. 42. Project construction shall protect private and public property in compliance with Sections 15.04.070 and 15.04.140. No work in the public right of way shall commence unless and until all necessary permits are attained from the Public Works Department including, if required, an approved Residential or Commercial Encroachment Permit. 43. Sewer manhole rim/lid elevations must be submitted prior to grading and plan check. 44. Sewer lateral video must be submitted with plan check submittal if the developer plans to use the existing sewer lateral. Sewer lateral work may be required after reviewing the sewer lateral video. 45. The project must comply with Storm Water and Urban Runoff Pollution Control Regulations (HBMC Ch. 8.44). Implement required Low Impact Development Standards, provide calculations and documents i.e. Appendix D and E of the Storm Water LID Guidelines, submit at time of grading and plan check along with an erosion control plan. SECTION 5. Pursuant to the Code of Civil Procedure Section 1094.6, any legal challenge to the decision of the Planning Commission, after exhaustion of any available administrative remedies, must be made within 90 days after the final decision by the City Council. The Hermosa Beach City Council may on its own initiative review all actions of the Planning Commission. If the City Council does not initiate review of this decision as set forth in Hermosa Beach Municipal Code Section 2.52.040, this decision will become final. PASSED, APPROVED, and ADOPTED on the 16th of December, 2025. Page 108 of 324 P a g e 13 of 13 ______________________________________________________________________________ VOTE: AYES: NOES: ABSTAIN: ABSENT: CERTIFICATION I hereby certify the foregoing Resolution PC 25-XX is a true and complete record of the action taken by the Planning Commission of the City of Hermosa Beach, California, at its regular meeting of December 16, 2025. Kate Hirsh, Chair Alison Becker, Secretary Date Page 109 of 324 Palm DrManhattan AveBeach D r 9th S t 7th S t 11th S t 10th S t Hermosa AveBeach D r 8th S t 6th S t P i e r A v e The St rand 7th C t 8th C t Sunset Dr 9th C t 10th C t 12th C t 11th C t Monterey B lvd Pier P l a z a Bayview DrProject Zoning Map Planning CommissionDecember 16, 2025 Description 901 Hermosa Avenue APN: 4187-003-028 Zone: C-2 Downtown Commercial Precise Development Plan Legend R-1 Single Family Residential R-1A Limited Single-Family Residential R-2 Two Family Residential R-2B Limited Multiple Family Residential R-3 Multiple Family Residential R-P Residential-Professional RPD Residential Planned Development R-3PD Multiple Family Planned Development C-1 Neighborhood Commercial C-2 Downtown Commercial C-3 General Commercial M-1 Light Manufacturing OS Open Space OS-1 Restricted Open Space OS-2 Restricted Open Space OS-O Open Space Overlay MHP Mobile Home Park SPA Specific Plan Area (Residential) SPA Specific Plan Area (Commercial) 500' Notification Radius Page 110 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 17 OF 141 G-101 COVER SHEET ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 ENTRY 101 DIMENSION TO FACE DIMENSION TO CENTERLINE REVISION NUMBER NEW ELEVATION BUILDING SECTION WALL SECTION DETAIL INTERIOR ELEVATION - MULTIPLE WALLS GRIDLINE TO FACE OF STRUCTURE EXISTING ELEVATION CONTROL POINT / DATUM ALIGN FINISH DESIGNATION EQUIPMENT MARK PLUMBING FIXTURES NEW WALL EXISTING WALL INTERIOR ELEVATION - 1 WALL EXTERIOR ELEVATION ROOM NAME ROOM NUMBER WALL TYPE WINDOW MARK DIRECTION OF SLOPE TO DRAIN DOOR MARK DASHED LINES INDICATE HIDDEN, OVERHEAD OR ITEMS TO BE REMOVED PROPERTY LINE BUILDING FLOOR OR ELEVATION SOLID LINE BREAK LINE - MATERIAL TO CONTINUE EXHAUST FAN GRIDLINE ON CENTER OF COLUMN FIRE SPRINKLER SMOKE DETECTOR KEYNOTE DIMMER/VACANCY SENSOR WALK STREET SETBACK 100 A 1001 SD WS SB SP PL-01 PT-01 APP-01 1 COVER SHEET & GENERAL INFO DIAGRAMS SURVEY - MAPPING DEMOLITION SITE DEMOLITION PLANS CIVIL G-101 G-102 G-201 G-202 G-203 G-204 V-101 AD-101 AD-111 AD-112 AD-113 C-000 C-100 C-210 C-300 C-400 COVER SHEET GENERAL NOTES SITE PHOTOS CURRENT VS PROPOSED SQ FT CODE REPORT CODE PLANS & SECTIONS SURVEY PLAN DEMOLITION SITE PLAN DEMOLITION 1st FLOOR PLAN DEMOLITION 2nd FLOOR PLAN DEMOLITION ROOF PLAN TITLE SHEET EROSION CONTROL PLAN GRADING AND DRAINAGE PLAN LOW IMPACT DEVELOPMENT PLAN UTILITY PLAN SITE PLANS FLOOR PLANS ELEVATIONS SECTIONS ENLARGED PLANS ASSEMBLY DETAILS SCHEDULES A-101 A-111 A-112 A-113 A-114 A-115 A-201 A-202 A-203 A-204 A-301 A-302 A-303 A-401 A-402 A-403 A-404 A-405 A-501 A-502 A-601 A-602 A-603 SITE PLAN FOUNDATION PLAN 1st FLOOR PLAN 2nd FLOOR PLAN 3rd FLOOR PLAN ROOF PLAN EXISTING ELEVATIONS EXISTING ELEVATIONS PROPOSED ELEVATIONS PROPOSED ELEVATIONS BUILDING SECTIONS BUILDING SECTION WALL SECTIONS STAIR 01 PLAN & SECTION STAIR 02 PLAN & SECTION STAIR 03 & ELEVATOR 02 PLAN & SECTION ENLARGED BATHROOM PLANS & ELEVATIONS ENLARGED KITCHEN PLANS & ELEVATIONS DETAILS - WALL ASSEMBLIES DETAILS - FLOOR / ROOF / CEILING ASSEMBLIES FINISH SCHEDULE & MATERIAL LEGEND DOOR + WINDOW SCHEDULES CURTAIN WALL SCHEDULE PROJECT INFORMATION PROJECT DIRECTORY ABBREVIATIONS RELEVANT CODESDEFERRED SUBMITTALS FIRE SPRINKLER NOTE SYMBOLS VICINITY MAP OTHER SHEET INDEX PROJECT ADDRESS 901 HERMOSA LEGAL DESCRIPTION LOT 25, 26 AND 27, BLOCK 10. HERMOSA BEACH, M.B. 1-25-26 APN# 4187-003-028 ZONE C2 (DOWNTOWN COMMERCIAL ZONE) LOT AREA (NET) 8,180 SF OCCUPANCY GROUP MERCANTILE OFFICE & STORAGE CONSTRUCTION TYPE TYPE V NO. OF STORIES THREE STORIES FIRE SPRINKLERS SPRINKLERS THROUGHOUT PARKING N/A SCOPE OF WORK MAJOR REMODEL OF EXISTING TWO-STORY COMMERCIAL STRUCTURE. PROPOSED WORK INCLUDES: REMOVE EXISTING EXTERIOR WALL FINISH AND INSTALL NEW FINISH OVER SUBSTRATE REMOVE EXISTING EXTERIOR DOORS AND REPLACE WITH NEW REMOVE EXISTING EXTERIOR WINDOWS AND REPLACE WITH NEW RECONFIGURE EXISTING INTERIOR SPACES PER PLANS. GC TO REMOVE DRYWALL AT ALL SURFACES AS NEEDED TO ACCOMMODATE REMODEL. EXISTING INTERIOR AND EXTERIOR LIGHTING TO BE REMOVED AND REPLACED EXISTING MECHANICAL EQUIPMENT AND DUCTWORK TO BE REMOVED AND REPLACED EXISTING ROOF AND ROOF DRAINAGE TO BE RENEWED. GC TO APPLY NEW FINISH TO EXISTING ROOF EXISTING FLOOR AND WALL FINISHES TO BE REMOVED THROUGHOUT EXISTING LOW VOLTAGE AND A/V SYSTEMS TO BE REMOVED AND REPLACED WITH NEW EXISTING PLUMBING FIXTURES TO BE REMOVED AND REPLACED WITH NEW. GC TO REWORK EXISTING PIPING AS NEEDED FOR NEW CONFIGURATION EXISTING HARDSCAPE, SOFTSCAPE, AND PLANTERS TO BE REMOVED. GC TO INSTALL NEW HARDSCAPE, SOFTSCAPE, AND PLANTERS PER PLANS REWORK EXISTING DRAINAGE AS NEEDED
 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2022 CMC, 2022 CEC, 2022 CPC, 2022 CRC CLIENT KYLE RANSFORD 901 HERMOSA PARTNERS LLC 2301 ROSECRANS AVENUE, SUITE 4130 EL SEGUNDO CA 90254 USA ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 ANTHONY@LANEY.LA (310) 870-7175 SURVEYOR DENN ENGINEERS 3914 DEL AMO BLVD, SUITE 921, TORRANCE, CA, 90503 (310) 542-9491 STRUCTURE + CIVIL LABIB FUNK + ASSOCIATES 319 MAIN STREET, EL SEGUNDO, CA 90245 (213) 239-9700 GEO-TECHNICAL ENGINEER NORCAL ENGINEERING 10641 HUMBOLT STREET, LOS ALAMITOS, CA 90720 (526) 799-9469 MEP NATIONAL ENGINEERING & CONSULTING, INC 30 THOMAS I, IRVINE, CA 92618 (714) 495-8004 @ AT A.F.F. ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE ACOUS ACOUSTICAL ADJ ADJUSTABLE ALUM ALUMINUM ANCH ANCHOR APPROX APPROXIMATELY ATTEN ATTENUATION BD BOARD BLDG BUILDING BLK BLOCK BM BEAM B.O. BOTTOM OF (C) COMPACT PARKING STALL CA CLEAR ANODIZED CAB CABINET CER CERAMIC CJ CONTROL JOINT CL CLOSET C.L. CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS DBL DOUBLE DTL DETAIL DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DN DOWN DS DOWNSPOUT DWG DRAWING EA EACH EL ELEVATION ELECT ELECTRICAL EQ EQUAL EQUIP EQUIPMENT (E) EXISTING EP ELECTRIC PANEL EXT EXTERIOR FD FLOOR DRAIN FIN. FINISH F.F.E. FINISH FLOOR ELEVATION FLR FLOOR FLUOR FLUORESCENT F.O. FACE OF FT FOOT FTG FOOTING FV FIELD VERIFY GA GAUGE GI GALVANIZED IRON GALV GALVANIZED GL GLASS GYP BD GYPSUM BOARD HD HEAD HDWD HARDWOOD HORIZ HORIZONTAL HT HEIGHT ID INSIDE DIAMETER IN INCH INSUL INSULATION INT     INTERIOR LAM     LAMINATE LAV     LAVATORY LT FXT  LIGHT FIXTURE MAX     MAXIMUM MEMB MEMBRANE MECH  MECHANICAL MTL       METAL MIN     MINIMUM (N)     NEW NIC     NOT IN CONTRACT OC     ON CENTER OD     OUTSIDE DIAMETER P.C.     PROPERTY CORNER P.L.     PROPERTY LINE PLT     PLATE PLAS     PLASTER PLWD     PLYWOOD R     RISERS RD     ROOF DRAIN R.O.     ROUGH OPENING RAD     RADIUS RDL     ROOF DRAIN LEADER REC     RECESSED REINF     REINFORCED REQ'D     REQUIRED RES     RESISTANT RESIL     RESILIENT RET     RETAINING REV.     REVERSE RM     ROOM S.S.     STAINLESS STEEL SV     SHEET VINYL SCHED     SCHEDULE SECT     SECTION SAM     SELF ADHERING MEMBRANE SFR     SINGLE FAMILY RESIDENCE SHT     SHEET SIM     SIMILAR SPEC     SQUARE STD     STANDARD STL     STEEL STRUCT     STRUCTURAL SUSP     SUSPENDED T     TREADS T&B     TOP AND BOTTOM T&G     TONGUE AND GROOVE T.O.     TOP OF T.O.C.     TOP OF CONCRETE TOP     TOPPING TELE     TELEPHONE TEMP     TEMPERED T.S.     TUBE STEEL TYP     TYPICAL UNO     UNLESS NOTED OTHERWISE URM     UNREINFORCED MASONRY VCT     VINYL COMPOSITION TILE W/          WITH WC     WATER CLOSET WF     WIDE FLANGE WP     WATERPROOF WD     WOOD WRB     WEATHER RESISTANT BARRIER ±     PLUS OR MINUS #     NUMBER - ANY EXISTING FIRE SPRINKLER OR FIRE ALARM SYSTEMS MUST SUBMIT FOR SEPARATE PLAN REVIEW. - FIRE SPRINKLERS SHALL BE UNDER SEPARATE PLAN CHECK PERMIT. - PROPERTY ADDRESS(S) MUST BE PERMANENTLY AFFIXED TO BUILDING IN ACCORDANCE WITH MBFC 505.1 PRIOR TO FINAL FIRE INSPECTION. [MBMC 3.16.20]. - AUTOMATIC COMMERCIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN THE BUILDING AND IN OTHER AREAS AS REQUIRED BY THE FIRE CODE OFFICIAL. - AUTOMATIC COMMERCIAL FIRE SPRINKLERS SHALL COMPLY WITH THE HERMOSA BEACH FIRE DEPARTMENT MINIMUM REQUIREMENTS FOR NFPA 13D FIRE SPRINKLER SYSTEMS. - HORN/STROBE ALARM DEVICES SHALL BE PLACED ON THE ADDRESS SIDE OF THE BUILDING UNLESS OTHERWISE SPECIFIED BY FIRE DEPARTMENT PERSONNEL. - ALL WATER PIPES TO SINKS AND LAUNDRY FACILITIES SHALL BE INSTALLED WITH SOUND DEADENING MATERIALS TO PREVENT THE TRANSFER OF NOISE. - ALL VOIDS AROUND PIPES SHALL BE PACKED WITH ROCK WOOL OR EQUIVALENT SOUND-DEADENING MATERIALS TO PREVENT THE TRANSFER OF NOISE. - NO PLUMBING VENTS OR SIMILAR EQUIPMENT SHALL BE PLACED BACK TO BACK BETWEEN SEPARATE DWELLING UNITS. • FIRE SPRINKLERS AND ALARMS A) DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN REVIEW. THE ENGINEER OF RECORD FOR THE BUILDING PROJECT SHALL PROVIDE A NOTE ON THE DEFERRED PLANS OR A SHOP DRAWING APPROVAL STAMP STATING THAT THE PLANS ARE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDINGS. (CBC 106.3.4.2) AN AUTOMATIC COMMERCIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN THE BUILDING AND IN OTHER AREAS AS REQUIRED BY THE FIRE CODE OFFICIAL. AUTOMATIC COMMERCIAL FIRE SPRINKLERS SHALL COMPLY WITH THE HERMOSA BEACH FIRE DEPARTMENT MINIMUM REQUIREMENTS FOR NFPA 13D FIRE SPRINKLER SYSTEMS. FIRE SPRINKLERS SHALL BE UNDER SEPARATE PLAN CHECK AND PERMIT [R313 CRC, 903.2.8.2 CFC AS AMENDED BY MBMC 3.16.020] Page 111 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 18 OF 141 G-102 GENERAL NOTES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 GENERAL CONSTR. HERMOSA BCH CITY BEST MANAGEMENT PRACTICES BUILDING & SAFETY PUBLIC WORKS CITY OF HERMOSA BEACH PLANNING A) CONSTRUCTION DOCUMENTS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND COMPLYING WILL ALL NOTES INCLUDED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BRING ANY AND ALL DISCREPANCIES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE CONSTRUCTION DRAWINGS, SPECIFICATIONS, ADDENDUMS, AND ANY REVISIONS ISSUED AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR WRITTEN CLARIFICATION. B) CONSTRUCTION DOCUMENTS; THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS ARE REPRESENTATIONAL OF THE FINISHED STRUCTURE AND DO NOT INDICATE THE MEANS + METHODS OF CONSTRUCTION, TECHNIQUES, SEQUENCING, OR PROCEDURES REQUIRED FOR CONSTRUCTION. C) APPROVED DRAWING SET: THE CONTRACTOR SHALL KEEP AND MAINTAIN THE CITY APPROVED RECORD SET OF DRAWINGS AT THE JOB SITE AT ALL TIMES. THE CONTRACTOR SHALL KEEP THE SET CURRENT WITH ANY APPROVED REVISIONS OR ADDENDA. D)MINIMUM STANDARDS OF WORK: IF ANY CONFLICT EXISTS IN QUALITY OF WORK OR CODE REQUIREMENTS, THE HIGHER QUALITY AND MORE RESTRICTIVE SHALL APPLY. E)NOT IN SCOPE: WORK INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS AS N.I.C. OR BY SEPARATE CONTRACTORS, IS NOT INCLUDED WITHIN THE CONTRACT OR CONSTRUCTION DOCUMENTS FOR THE PROJECT. CONTRACTOR SHALL COOPERATE FULLY WITH ALL SEPARATE CONTRACTORS CONTRACTED WITH THE OWNER. F) CODE COMPLIANCE: THE WORK SHALL BE COMPLIANT WITH ALL APPLICABLE CODE, ORDINANCES, AND REGULATIONS LISTED IN THE CONSTRUCTION DOCUMENTS AND AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. G) OSHA COMPLIANCE: WORK SHALL COMPLY WITH PERTINENT HEALTH AND SAFETY REGULATIONS FOR REQUIRED METHODS TO PROTECT ALL PERSONS INVOLVED WITH THE WORK OR VISITING THE SITE DURING THE CONSTRUCTION PERIOD. H) SITE MEASUREMENTS: CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALLDIMENSIONS IN THE FIELD PRIOR TO STARTING ANY WORK. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE DRAWINGS TO THE ARCHITECT PRIOR TO CONTINUING WORK. I) DIMENSIONS: THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY CONFLICTING DIMENSIONS BETWEEN ARCHITECTURAL + ENGINEERING DRAWINGS. THE CONTRACTOR SHALL NOT SCALE ANY DIMENSIONS OFF OF THE DRAWINGS. J) DETAILS: DETAILS PROVIDED WITHIN THE CONSTRUCTION DOCUMENTS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED PER FIELD CONDITIONS. CONTRACTOR TO NOTIFY ARCHITECT OF SUCH REVISIONS. K) SUBSTITUTIONS: NO SUBSTITUTIONS ARE ALLOWED UNLESS SPECIFICATIONS ARE SUBMITTED TO AND APPROVED BY THE OWNER AND ARCHITECT. L)CONTRACT DEVIATIONS: ANY VALUE ENGINEERING OR SUBSTITUTION OF REQUIREMENTS NOTED IN THE CONTRACT DOCUMENTS TAKEN WITHOUT WRITTEN CONSENT FROM THE ARCHITECT,SHALL RELEASE THE ARCHITECT FROM ANY AND ALL LIABILITY FOR THAT PORTION OF THE PROJECT. M) COORDINATION WITH CONTRACTORS/CONSULTANTS: THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH ALL OTHER TRADES, CONSULTANTS, AND SUB-CONTRACTORS WORKING ON THE PROJECT WHETHER UNDER CONTRACT OF THE CONTRACTOR OR OWNER. N) DIMENSIONS: ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DIMENSIONAL CONFLICTS WITHIN THE CONTRACT DOCUMENTS. O) SITE ACCESS: THE CONTRACTOR SHALL GIVE THE CLIENT, ARCHITECT, CONSULTANTS, AND INSPECTORS ACCESS TO THE JOB SITE DURING NORMAL BUSINESS HOURS FOR THE DURATION OF CONSTRUCTION. P) SITE OBSERVATION: ANY SITE OBSERVATION BY THE ARCHITECT DURING CONSTRUCTION IS FOR THE SOLE PURPOSE OF REVIEWING THE WORK FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT IS NOT RESPONSIBLE FOR INSPECTION OF PROTECTIVE MEASURE ORTHE CONSTRUCTION PROCEDURES OR FOR GUARANTEEING THE CONTRACTOR'S WORK. Q) DAMAGES: CONTRACTOR TO PROTECT ALL AREAS ADJACENT TO CONSTRUCTION AREAS FROM DAMAGE CAUSED BY MOVEMENT OF MATERIALS OR DUST. ALL DAMAGE INCURRED SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. R) SITE EGRESS: ALL EXIT DOORS, EXIT ACCESS, AND CORRIDORS SHALL REMAIN UNOBSTRUCTED AT ALL TIMES. MATERIALS SHALL NOT BE STORED OR STOCKPILED IN A MANNER WHICH BLOCKS EGRESS OF CREATES AN UNSAFE CONDITION. S) SITE CLEANLINESS: CONTRACTOR SHALL MAINTAIN A CLEAN JOB SITE FREE OF TRASK AND DEBRIS. WORK AREAS SHALL BE MAINTAINED IN A BROOM CLEAN CONDITIONS AT THE END OF EACH WORK DAY/SHIFT. T) STORING + DISPOSING OF MATERIALS: ALL CONSTRUCTION WORK INCLUDING MATERIALS OF CONSTRUCTION AND PROCEDURES FOR STORING, DISPOSING OF, AND INSTALLING MATERIALS SHALL CONFORM TO THE LATEST ADOPTED CODES OF THE LOCAL AUTHORITY HAVING JURISDICTION. U) ROUGH UTILITIES: CONTRACTOR SHALL FURNISH AND INSTALL ROUGH PLUMBING AND ELECTRICAL AND FINAL HOOK-UP FOR ALL SPECIFIED FIXTURES, APPLIANCES, AND EQUIPMENT. V) ACCESS PANELS: CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL ACCESS PANELS REQUIRED IN CEILINGS, WALLS, OR FLOORS FOR ACCESS TO ALL EQUIPMENT AS REQUIRED PER APPLICABLE CODE. W) EQUIPMENT STANDARDS: ALL ELECTRICAL, MECHANICAL AND PLUMPING FIXTURES/ EQUIPMENT SHOULD BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY. X) SUBMITTALS: THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT SUBMITTALS FOR REVIEW DURING CONSTRUCTION PRIOR TO COMMENCEMENT OF SPECIFIC WORK. SUBMITTALS INCLUDE, BUT ARE NOT LIMITED TO, MATERIAL DATA SHEETS, PHYSICAL SAMPLES, AND SHOP DRAWINGS AND SHALL BE SUPPLIED TO THE ARCHITECT AS REQUESTED. A) BACK FLOW DEVICES: ALL LANDSCAPE IRRIGATION BACK FLOW DEVICES MUST MEET CURRENT CITY REQUIREMENTS FOR PROPER INSTALLATION. B) WASTE REMOVAL: NO DISCHARGE OF CONSTRUCTION WASTEWATER, BUILDING MATERIALS, DEBRIS, OR SEDIMENT FROM THE SITE IS PERMITTED. NO REFUSE OF ANY KIND GENERATED ON A CONSTRUCTION SITE MAY BE DEPOSITED IN RESIDENTIAL, COMMERCIAL, OR PUBLIC REFUSE CONTAINERS AT ANY TIME. THE UTILIZATION OF WEEKLY REFUSE COLLECTION SERVICE BY THE CITY'S HAULER FOR ANY REFUSE GENERATED AT THE CONSTRUCTION SITE IS STRICTLY PROHIBITED. FULL DOCUMENTATION OF ALL MATERIALS/TRASK LANDFILLED AND RECYCLED MUST BE SUBMITTED TO THE PERMITS DIVISION IN COMPLIANCE OF THE CITY'S CONSTRUCTION AND DEMOLITION RECYCLING ORDINANCE. C) SEWER CLEANOUT: A PROPERTY LINE CLEANOUT MUST BE INSTALLED ON A 6 DEGREE SANITARY SEWER LATERAL. IF THERE IS NO 6 DEGREE LATERAL, THEN A NEW ONE MUST BE INSTALLED WITHIN THE PROPERTY LINES. SEE LOCAL PUBLIC WORKS DEPARTMENT FOR TYPICALCONSTRUCTION DETAILS. D) BACKWATER VALVE: A BACKWATER VALVE IS REQUIRED ON THE SANITARY SEWER LATERAL IF THE DISCHARGES FROM FIXTURES WITH FLOOD LEVEL RIMS ARE LOCATED BELOW THE NEXT UPSTREAM MANHOLE COVER OF THE PUBLIC SEWER. SEE LOCAL PUBLIC WORKS DEPARTMENT FOR TYPICAL CONSTRUCTION DETAILS. E) EXISTING SEWER LATERAL: IF AN EXISTING SEWER LATERAL IS USED, IT MUST BE TELEVISED TO VERIFY ITS STRUCTURAL INTEGRITY. THE TAPE MUST BE MADE AVAILABLE FOR REVIEW BY THE PUBLIC WORKS DEPARTMENT. THE LOCAL PUBLIC WORKS DEPARTMENT WILL REVIEW THE TAPE AND DETERMINE AT THAT TIME IF THE SANITARY LATERAL NEEDS REPAIRING, REPLACING, OR THAT IT IS STRUCTURALLY SOUND AND CAN BE USED IN ITS PRESENT CONDITION. F) UNUSED LATERALS: ANY UNUSED WATER OR SANITARY SEWER LATERALS MUST BE ABANDONED AT THE CITY MAIN. G) PROTECTION OF PROPERTY: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECTALL THE STREET SIGNS, STREET LAMPS/LIGHTS, PARKING METERS, AND/OR TREES AROUND THE PROPERTY. IF THEY ARE DAMAGED, LOST OR REMOVED, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE THEM AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS ALSO RESPONSIBLE FOR ANY STREET MARKINGS THAT ARE DAMAGED OR REMOVED BY THE CONTRACTOR'S OPERATIONS. CONTACT THE PUBLIC WORKS INSPECTOR FOR SIGN SPECIFICATION AND SUPPLIERS. H) WATER METERS: WATER METERS MUST REMAIN ACCESSIBLE FOR METER READERS DURING CONSTRUCTION. WATER METERS SHALL BE PLACED NEAR THE PROPERTY LINE AND OUT OF THE DRIVEWAY APPROACH WHENEVER POSSIBLE. THE WATER METER BOX MUST BE PURCHASED FROM THE CITY AND MUST HAVE A TRAFFIC RATED LID IF THE BOX IS LOCATED IN THE DRIVEWAY. I) PARKWAY TREES: IF ANY PARKWAY TREES ARE REMOVED, THEY MUST BE REPLACED WITH TREES SELECTED FROM THE CITY'S APPROVED PARKWAY TREE LIST AND PLANTED IN ROOT BARRIER BOXES. J) BEST MANAGEMENT PRACTICES: EROSION AND SEDIMENT CONTROL DEVICES BMP'S (BESTMANAGEMENT PRACTICES) MUST BE IMPLEMENTED AROUND THE CONSTRUCTION SITE TO PREVENT DISCHARGE TO THE STREET AND ADJACENT PROPERTIES. CONTROL MEASURES MUST ALSO BE TAKEN TO PREVENT STREET SURFACE WATER FROM ENTERING THE SITE. K) DRAIN LINES: ALL DRAIN LINES INSTALLED WITHIN THE STREET RIGHT-OF-WAY MUST BE CONSTRUCTED OF DUCTILE IRON PIPE. DRAINS MUST BE SHOWN ON PLANS. L) RUNOFF DISCHARGE: ALL RUNOFF WATER FROM THE ROOF, SIDE YARDS, AND PATIOS MUST DISCHARGE ONTO STREET. A) TYPE OF CONSTRUCTION: ALL PERSONS WORKING ON THE SITE SHOULD OBTAIN, READ, AND UNDERSTAND THE BEST MANAGEMENT PRACTICES PAMPHLET FOR THE TYPE(S) OF CONSTRUCTION BEING DONE. B) SITE WASH-OFF: STOCKPILES OF SOILS, DEMOLITION DEBRIS, CEMENT, SAND, TOPSOIL, ETC.,MUST BE COVERED WITH WATERPROOF MATERIALS OR BERMED TO PREVENT BEING WASHED OFF SITE. C) LIQUID MATERIALS: FUELS, OILS, PAINTS, SOLVENTS, AND OTHER LIQUID MATERIALS MUST NOT BE WASHED INTO THE STREET. D) CONCRETE WASTE: WASTE CONCRETE MUST NOT BE WASHED INTO STREET, STORM DRAIN CATCH BASINS, OR PUBLIC RIGHT-OF-WAY. ALL DUST AND SLURRY FROM CONCRETE CUTTING MUST BE REMOVED USING WET-DRY VACUUM OR EQUIVALENT. E) SOLID WASTE: TRASH AND OTHER CONSTRUCTION SOLID WASTE MUST BE PLACED IN A COVERED TRASH RECEPTACLE. F) ERODED SOIL: ERODED SOIL FROM DISTURBED SLOPED MUST BE CONTAINED USING BERMS, SILT FENCES, SETTING BASINS, OR GOOD EROSION MANAGEMENT PRACTICES SUCH AS RESEEDING. G) WASH WATER: WASH WATER FROM CLEANING CONSTRUCTION VEHICLES AND EQUIPMENTMUST BE KEPT ON-SITE WITHIN A CONTAINMENT AREA. H) CONCRETE DRIVEWAY: CONSTRUCT NEW COMMERCIAL CONCRETE DRIVEWAY TYPE WHERE NOTED ON SITE PLAN. NEW CONCRETE SHALL BE CLASS 520-C-2500. I) PREFABRICATED BEAMS: SUBMIT CERTIFICATE OF PREFABRICATED BEAMS TO BUILDING INSPECTOR PRIOR TO INSTALLATION OF SUCH BEAMS. X) A) CONSTRUCTION TIMES: CONTRACTOR SHALL CONFIRM HOURS FOR CONSTRUCTION ACTIVITY WITH LOCAL AGENCY AND ONLY OPERATE DURING APPROVED HOURS. NO CONSTRUCTION IS PERMITTED OUTSIDE OF THOSE HOURS. B) CONSTRUCTION SIGNS: CONTRACTOR SHALL CONFIRM REQUIREMENTS FOR CONSTRUCTION SITE SIGNAGE WITH LOCAL AGENCY. CONTRACTOR SHALL PROVIDE AND MAINTAIN REQUIRED SIGNAGE AT PROJECT SITE AT ALL TIMES. C) CONSTRUCTION FENCE: CONTRACTOR SHALL PROVIDE CONSTRUCTION FENCE PER CBC 3303 AT PUBLIC RIGHT-OF-WAY FOR PEDESTRIAN PROTECTION IF ANY WORK IS TO BE PERFORMED ON ANY BUILDING OR STRUCTURE ADJACENT TO PUBLIC RIGHT-OF-WAY. D) DEMOLITION: NO DEMOLITION SHALL COMMENCE WITHOUT A VALID DEMOLITION PERMIT. WORK COMMENCES WITHOUT A VALID PERMIT MAY BE SUBJECT TO A SPECIAL INVESTIGATION BEFORE A PERMIT MAY BE ISSUED. E) GRADING PERMIT: A GRADING PERMIT IS REQUIRED WHEN GRADING OR EXCAVATION INVOLVES A CUT OR FILL DEPTH OF 3' OR MORE AND/OR 200 CUBIC YARDS. SUBMIT GRADING PLAN AND SOILS REPORT TO THE BUILDING DEVISION FOR REVIEW AND APPROVAL. DUST SHALL BE CONTROLLED CONTINUOUSLY BY WATERING OR BY OTHER APPROVED MEANS OF EXCAVATING. CONTRACTOR SHALL NOTIFY THE UNDERGROUND SERVICE ALERT (1-800-422-4133) PRIOR TO ANY EXCAVATION. F) SHORING PERMIT: A SHORING PERMIT IS REQUIRED FOR ANY VERTICAL CUT OR FILL THAT IS EQUAL TO OR GREATER THAN 5' IN HEIGHT. ENGINEERED SHORING PLANS AND CALCULATIONS AND SOILS REPORT MUST BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW AND APPROVAL PER SECTION 3301.2 OF THE CBC. THE HOLDER OF A SHORING PERMIT SHALL NOTIFY IN WRITING ALL THE OWNER'S OF ADJOINING PROPERTIES NOT LESS THAN 10 DAYS BEFORE SUCH EXCAVATION IS TO COMMENCE. AN OSHA PERMIT IS ALSO REQUIRED - A COPY OF WHICH SHALL BE SUBMITTED TO THE BUILDING DEVISION. SHORING CONTRACTOR SHALL NOTIFY THE UNDERGROUND SERVICE ALERT (1-800-422-4133) PRIOR TO ANY EXCAVATION. G) SANDBLASTING: THE SANDBLASTING MUST BE WET SANDBLASTING AND ALL THE PRECAUTIONARY MEASURES MUST BE TAKEN BY THE CONTRACTOR TO PROTECT LIFE AND PROPERTY OF NEIGHBORS, RESIDENTS AND THE PUBLIC. ADJACENT PROPERTY OWNERS MUST BE NOTIFIED AT LEAST (2) DAYS PRIOR TO SANDBLASTING. H) SITE DRAINAGE: PROVIDE ROOF GUTTERS AND DOWNSPOUTS OR CONCRETE PAVEMENT/SWALE ON GROUND TO DIVERT OR CARRY SURFACE WATER AWAY FROM BUILDING TO CATCH BASIN AND DRAIN PIPES THROUGH CURB TO STREET AND STORM DRAIN SYSTEM. I) STAIRWAYS: WIDTH OF STAIRWAYS SHALL BE 36" MIN CLEAR TAKEN FROM FACE OF FINISH. GUARDRAILS OR HANDRAIL PICKETS SHALL HAVE A MAXIMUM 4" SPACING BETWEEN PICKETS. J) GARAGE DOOR: GARAGE DOOR OPENING INCLUDING HARDWARE SHALL BE 7' MINIMUM AND 18' WIDE. GARAGE DOOR SPRINGS AND OPENERS SHALL BE STATE APPROVEDAND WITH MANUFACTURER'S LABEL. DOOR LEADING FROM GARAGE TO DWELLING UNIT SHALL BE A 20 MINUTE FIRE RATED, 1-3/8" SOLID WOOD, SELF-CLOSING, AND TIGHT FITTING DOOR. K) NAILS: ONLY COMMON NAILS SHALL BE PERMITTED FOR THE REQUIRED NAILINGS ON VERTICAL AND HORIZONTAL DIAPHRAGMS SUCH AS SHEAR WALLS AND ROOF/FLOOR SHEATHINGS RESPECTIVELY. L) REBAR WELDING: WELDING OF REBAR SHALL COMPLY WITH CBC, STANDARD 19-1. CONTRACTOR TO SUBMIT WELDING PROCEDURES AND QUALIFICATION OF DEPUTY/SPECIAL INSPECTIONS IN ACCORDANCE WITH SPECIAL INSPECTION PROGRAM TO THE BUILDING DIVISION FOR APPROVAL PRIOR TO ANY WELDING WORK. M) FUTURE UTILITIES: CONTRACTOR TO PROVIDE UNDERGROUND CONDUIT FOR FUTURE ELECTRICAL LINES AT THE PRONT PROPERTY LINES. CONTRACTOR TO COORDINATE WITH INSPECTOR FOR ADDITIONAL COMMENTS. A) SEPARATE PERMITS: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR SPAS, POOLS, SOLAR PANELS, DEMOLITION, AND SEWER CAP OF EXISTING BUILDINGS. B) VERTICAL PROJECTIONS IN SETBACKS: FENCE, WALL, AND HANDRAIL HEIGHTS AS MEASURED FROM THE LOWEST FINISHED GRADE ADJACENT TO EACH SECTION OF THESE STRUCTURES, MAY BE A MAXIMUM OF 42" IN THE FRONT YARD SETBACK, AND 72" AT ALL OTHER LOCATIONS ON SITE UNLESS LOCATED IN A LINE-OF-SIGHT OR DRIVEWAY VISIBILITY AREA. CONTRACTOR TO CONFIRM HEIGHT LIMITATIONS WITH THE LOGAL PLANNING DEPARTMENT C) ADDRESS NUMBERS: BUILDING ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND AND BE 4" MINIMUM HIGH WITH A MINIMUM STROKE WIDTH OF 0.5" PER CBC R319.9. D) ON SITE PARKING: PARKING IS NOT PERMITTED IN REQUIRED YARDS OR OPEN SPACE EXCEPT FOR A 20' WIDE FRONT YARD DRIVEWAY. E) FUTURE SOLAR WATER HEATING: A "CAPPED TEE" FITTING MUST BE INSTALLED OVER THE COLD WATER SUPPLY LINE ABOVE THE WATER HEATER FOR FUTURE SOLAR WATER HEATING. PIT RELIEF VALVE SHALL TERMINATE OUTSIDE THE BUILDING. F) UNDERGROUND CONDUIT: ROUTE UNDERGROUND CONDUIT TO POWER POLE PER PUBLIC WORKS STANDARD DETAILS. STUB OUT FOR PROPERTY LINE FOR FUTURE UNDER-GROUNDING OF UTILITIES WHEN APPLICABLE. G) MECHANICAL EQUIPMENT SCREENING: PROVIDE VISUAL SCREENING FOR PROPOSED MECHANICAL EQUIPMENT AND UTILITY METERS. TOP NEED NOT TO BE SCREENED IF LOCATED ON INTERIOR SIDE OF DWELLING. H) METER CLEARANCE: GAS AND ELECTRIC METERS MUST CLEAR PROPERTY LINES BY 3'-0". I) CESSPOOL LOCATIONS: IF THERE IS AN EXISTING CESSPOOL ON SITE, IT MUST BE LOCATED BY CITY PERSONNEL BEFORE DEMOLITION OR BUILDING PERMITS CAN BE ISSUED. CONTRACTOR TO VERIFY EXISTENCE OF CESSPOOL WITH LOCAL AUTHORITY HAVING JURISDICTION PRIOR TOPROCEEDING WITH DEMOLITION OR CONSTRUCTION ACTIVITIES. Page 112 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 19 OF 141 G-201 SITE PHOTOS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 WEST VIEW NORTHEAST VIEW NORTHWEST VIEW SOUTHEAST VIEW SOUTHWEST VIEW Page 113 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 20 OF 141 G-202 CURRENT VS PROPOSED SQ FT ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 4,093 sq ft 3,560 sq ft OPENTO BELOW OPEN TOBELOW OPEN TO BELOW OPENTO BELOW LOWER FLOOR ONLY OPENTO BELOW OPEN TOBELOW OPEN TOBELOW OPEN TO BELOW 887 sq ft 476 sq ft 476 sq ft2,520 sq ft OPENTO BELOW 817 sq ft 146 sq ft 123456789101112131415161718 UP18 RISERS (6 23/32") 4'-9 1/2" 2,360 sq ft 1,973 sq ft 684 sq ft RETAIL 104RETAIL105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM106 RSTRM 103 STAIR 02 114 STAIR 01121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE111 RETAIL101 HALL 102 ELEV RM121 ELECTRIC RM 120 TRANSFORMER 121 OPENTO ABOVE 1234567 8 UP 20 RISERS (7") RESTRM108 ACC. RSTRM109 TRASH RM 119 499 sq ft DN 2,268 sq ft OPEN TOBELOW OPEN TOBELOW OPEN TOBELOW DEACTIVATED SPACE (NOT ACCESSIBLE) OPEN TOABOVE OPEN TOBELOW OFFICE 207 OFFICE206 OFFICE205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02 209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 DN 12345 67UP 12 RISERS (6 1/2")123456789101112131415 16UP 16 RISERS (6 25/32") OPEN TO ABOVE 3,906 sq ft SK-1 SK-2 SK-3 F DW F 45" CLROPENTO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPENTO ABOVE ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE 301 OFFICE315 OFFICE 308 OFFICE 310 COURTYARD 318 GARDEN316 CONFERENCE RM314 OFFICE 309 OFFICE 304 RSTRM321 KITCHEN 319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM 317 GARDEN 311 GARDEN320 GARDEN 323 VESTIBULE 306 STAIRWELL EXIT 325 RESTROOM CORRIDOR 324 MECH. PLATFORM302 STAIR 01 327 OPEN TO ABOVE OPEN TO ABOVE OPEN TOABOVE DN DN 41 sq ft 111 sq ft OPEN TOABOVE OPEN TOABOVE GREEN ROOF307 GROSS SQUARE FOOTAGE EXISTING SQ FT PROPOSED SQ FT NET PROPOSED EXPANSION SQ FT FIRST FLOOR 7653 5980 -1673 STORAGE 3,560 2,360 -1,200 RETAIL 4,093 1,973 -2,120 RETAIL STORAGE 0 817 817 OFFICE 0 684 684 UTILITIES/STAIRS 0 146 146 SECOND FLOOR 4359 2767 -1592 STORAGE 3,472 2268 -1204 RETAIL STORAGE 0 0 0 OFFICE 887 499 -388 THIRD FLOOR 0 4058 4058 OFFICE 0 3906 3906 STAIRS 0 152 152 TOTAL 12012 12805 793 F.A.R. (8180 SF SITE)1.47 1.57 2 10 10 NOT TO SCALE1EXISTING FIRST FLOOR NOT TO SCALE2EXISTING SECOND FLOOR NOT TO SCALE3PROPOSED FIRST FLOOR NOT TO SCALE4PROPOSED SECOND FLOOR NOT TO SCALE5PROPOSED THIRD FLOOR NOT TO SCALE6GROSS SQUARE FOOTAGE Page 114 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 21 OF 141 G-203 CODE REPORT ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 ZONING SUMMARY APPLICABLE CODE: HERMOSA BEACH MUNICIPAL CODE (HBMC) ZONING DESIGNATION: COMMUNITY COMMERCIAL - CC (GENERAL PLAN) GENERAL COMMERCIAL - C2 (HBMC) CHARACTER AREA: DOWNTOWN CENTER NEIGHBORING ZONING: LOT TO NORTH = C2 (GENERAL COMMERCIAL) LOT TO EAST = C2 (GENERAL COMMERCIAL) LOT TO SOUTH = R2/C2 (TWO-FAMILY RESIDENTIAL & GENERAL COMMERCIAL) LOT TO WEST = R2 (TWO-FAMILY RESIDENTIAL) PARCEL NUMBER: 4187003028 SITE AREA: 8180 SQFT BUILDING AREA PROPOSED:14,018 SQFT 1ST FLOOR PROPOSED: 7,531 SQFT 2ND FLOOR PROPOSED: 2,833 SQFT 3RD FLOOR PROPOSED: 3,654 SQFT ZONING ANALYSIS HBMC 17.26.050 STANDARDS AND LIMITATIONS FRONT: N/A PROPOSED: NO CHANGE TO EXISTING REAR: N/A (EXISTING BUILDING PER 17.26.050.H.3) PROPOSED: NO CHANGE TO EXISTING SIDE: N/A (EXISTING BUILDING PER 17.26.050.H.3) PROPOSED: NO CHANGE TO EXISTING GENERAL PLAN INTENSITY RANGE (FAR) MAX FAR: 1.25 FOR COMMUNITY COMMERCIAL 1.25 * 8,180 SF = 10,225 SF MIN FAR: .5 FOR COMMUNITY COMMERCIAL .5 * 8,180 SF = 4,090 SFPROPOSED: EXEMPTION: THE PROJECT BUILDING IS EXISTING AND FALLS OUTSIDE FAR MAX; SEE SHEET G201 HBMC 17.26.050 STANDARDS AND LIMITATIONS THE DESIGN OF ALL SIGNS SHALL BE IN CONFORMANCE WITH THE DESIGN STANDARDS REFERENCED IN HBMC 17.50.130. HBMC 17.26.050(E) BUILDING HEIGHT MAX BUILDING HEIGHT: 30'-0" EXISTING: 16.71' MIN - 23.82' MAX PROPOSED: 28.81' MIN - 29.97' MAX (SEE ROOF PLAN SHEET FOR CALCS) HBMC 17.26.050(F,G,H) SETBACKS FRONT YARD SETBACK: N/A PROPOSED: EXISTING BUILDING FOOTPRINT ALLEY SETBACK: SHALL CONFORM W/ SECTION 17.44.130 PROPOSED: EXISTING BUILDING FOOTPRINT REAR YARD SETBACK: 5' SETBACK PROPOSED: EXISTING BUILDING FOOTPRINT EXISTING: ZERO LOT-LINE CONDITIONS AT NORTH, EAST, & SOUTH; WEST PROP LINE SETBACK OF 2.8' HBMC 17.46.010 HEIGHT OF ROOF STRUCTURES A. ELEMENTS LISTED IN 17.46.010.A MAY BE CONSTRUCTED ABOVE THE HEIGHT LIMIT, PROVIDED THEY DO NOT EXCEED THE HEIGHT LIMIT BY MORE THAN 8 FEET AND COVER NO MORE THAN 5 PERCENT OF THE TOTAL ROOF AREA. HBMC 17.44.015 OFF-STREET PARKING (APPLICABILITY) D.1 ADDITIONS LESS THAN 10 PERCENT OR 500 SF. NO ADDITIONAL PARKING IS REQUIRED FOR ALTERATIONS TO EXISTING BUILDINGS THAT DO NOT CHANGE THE BUILDING SQUARE FOOTAGE ON SITE BY MORE THAN 10 PERCENT OR 500 SF, WHICHEVER IS GREATER, PROVIDED THE USE IS OTHER THAN A LATE NIGHT ALCOHOL ESTABLISHMENT PARKING PROPOSED: N/A - EXISTING SITE WILL REMAIN WITH ZERO PARKING SPACES HBMC 17.46.220 SOLAR ENERGY SYSTEMS-HEIGHT LIMIT EXCEPTION AND STREAMLINED PERMITTING C1. SOLAR COLLECTORS AND SOLAR ENERGY SYSTEMS MAY EXCEED THE HEIGHT LIMITS MANDATED BY THIS CODE TO THE MINIMUM EXTENT NECESSARY FOR THEIR SAFE AND EFFICIENT OPERATION IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE AND OTHER APPLICABLE PROVISIONS OF STATE LAW. HBMC 12.36.060 PERMIT REQUIREMENT FOR TREE REMOVAL E. A PERMIT TO REMOVE A TREE SHALL BE CONDITIONED ON REPLACEMENT OF THE TREE, EITHER ON SITE OR ELSEWHERE AS DESCRIBED BY THE CITY. ON-SITE REPLACEMENT IS REQUIRED UNLESS ON-SITE REPLACEMENT IS INFEASIBLE. REMOVED TREES SHALL BE REPLACED AT A MIN 2:1 RATIO WITH A TREE FROM THE CITY'S OFFICIAL LIST OF APPROVED PARKWAY TREES. TREES REMOVED: 1 TREE TREES PROPOSED: 4TREES 123456789101112131415161718 UP18 RISERS (6 23/32") 29'-0" 51'-5" EXIT 8 RETAIL104RETAIL 105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM106 RSTRM103 STAIR 02114 STAIR 01 121 FIRE (ASR) RM118 RESTRM CORRIDOR107 ELEVATOR 02 OFFICE111 RETAIL101 HALL 102 ELEV RM 121 ELECTRIC RM 120 TRANSFORMER1211234567 8 UP 20 RISERS (7") RESTRM 108 ACC. RSTRM109 TRASH RM119 DN 81'-4 "OFFICE207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 DN 123456 7UP 12 RISERS (6 1/2")12345678910111213141516 UP 16 RISERS (6 25/32") SK-1 SK-2 SK-3 F DW F 45" CLR1 0 3'- 5 " ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM 314 OFFICE 309 OFFICE304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM317 GARDEN311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN GREEN ROOF 307 BUILDING CODE SUMMARY APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 HERMOSA BEACH MUNICIPAL CODE (HBMC) OCCUPANCY CLASSIFICATION (302): BUSINESS: B MERCANTILE: M STORAGE: S-1 CONSTRUCTION TYPE FOR EXISTING AND NEW PORTIONS OF PROJECT (601): TYPE: VB - 0 HOUR FIRE SPRINKLER REQUIREMENTS (903): PER 903.2.7 - M OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM PER 903.2.9 - S1 OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM REQUIRED: FIRE SPRINKLER NOT REQUIRED PROPOSED: NFPA 13 SPRINKLER PROVIDED GENERAL CODE CHAPTER 5: BUILDING HEIGHT AND AREA 504 - 506 TABLE: ALLOWABLE BUILDING HEIGHTS, STORIES ABOVE GRADE PLAN, AND AREAS: TYPE VB CONSTRUCTION / SPRINKLERED / B OCCUPANCY: 60' H / 3-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / M OCCUPANCY: 60' H / 2-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / S-1 OCCUPANCY: 60' H / 2-STORIES / 27,000 SF EXISTING HEIGHT / STORIES / AREA: 23.32' MIN - 24.48' MAX / 2 STORIES / 13,943 SF PROPOSED HEIGHT / STORIES / AREA: 28.81' MIN - 29.97' MAX / 3 STORIES / 13,885 SF CHAPTER 6: TYPES OF CONSTRUCTION 601 TABLE: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS): PRIMARY STRUCTURAL FRAME 0 HR EXTERIOR BEARING WALLS 0 HR INTERIOR BEARING WALLS 0 HR INTERIOR NONBEARING WALLS AND PARTITIONS 0 HR FLOOR CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES 705.2: PROJECTIONS PROJECTS SHALL NOT EXTEND ANY CLOSER TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE THAN SHOWN IN TABLE 705.2 705.2.2: TYPE III, IV, OR V CONSTRUCTION PROJECTIONS FROM WALLS OF TYPE III, IV, OR V CONSTRUCTION SHALL BE OF ANY APPROVED MATERIAL 705.5 FIRE-RESISTANCE RATINGSEXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION 601 AND 602. THE REQUIRED FIRE- RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF GREATER THAN 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF LESS THAN OR EQUAL TO 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. TABLE: FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (HOURS): GROUP B / TYPE VB LESS THAN 5'-0" 0 HR 5'-0" TO LESS THAN 10'-0" 0 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR GROUP M & S-1 / TYPE VBLESS THAN 5'-0" 2 HR 5'-0" TO LESS THAN 10'-0" 1 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR EXISTING SEPARATION DISTANCE (SEE SITE PLAN A101) 705.8: OPENINGS OPENINGS IN EXTERIOR WALLS SHALL COMPLY WITH SECTION 705.8.1 THROUGH 705.8.6 705.8.1: ALLOWABLE AREA OF OPENINGS EXCEPTION 2: BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR NONBEARING WALLS AND EXTERIOR PRIMARY STRUCTURAL FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED SHALL BE PERMITTED TO HAVE UNLIMITED UNPROTECTED OPENINGS. 705.8.5: VERTICAL SEPARATION OF OPENINGS EXCEPTION 2: THIS SECTION SHALL NOT APPLY TO BUILDINGS THAT ARE THREE STORIES OR LESS ABOVE GRADE PLAN EXCEPTION 3: THIS SECTION SHALL NOT APPLY TO BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEMIN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.1.2 705.11: PARAPETS PARAPETS SHALL BE PROVIDED ON EXTERIOR WALLS OF BUILDINGS EXCEPTION: A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF THE FOLLOWING CONDITIONS ARE MET - THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 705.5 BECAUSE OF FIRE SEPARATION DISTANCE 708.6: OPENINGS (EXTERIOR WALL) OPENINGS IN A FIRE PARTITIONS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716 708.7: PENETRATIONS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION SHALL COMPLY WITH SECTION 714 708.9: DUCTS AND AIR TRANSFER OPENINGS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION BY DUCTS AND AIR TRANSFER OPENINGS SHALL COMPLY WITH SECTION 717 711.2.3: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) THE SUPPORTING CONSTRUCTION SHALL BE PROTECTED TO AFFORD THE REQUIRED FIRE-RESISTANCE RATING OF THE HORIZONTAL ASSEMBLY SUPPORTED EXCEPTION: IN BUILDINGS OF TYPE IIB, IIIB, OR VB CONSTRUCTION, THE CONSTRUCTION SUPPORTING THE HORIZONTAL ASSEMBLY IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED AT THE FOLLOWING: - HORIZONTAL ASSEMBLIES AT THE SEPARATIONS OF INCIDENTAL USES AS SPECIFIED BY TABLE 509.1 PROVIDED THAT THE REQUIRED FIRE-RESISTANCE RATING DOES NOT EXCEED 1 HOUR. - HORIZONTAL ASSEMBLIES AT SMOKE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 709 711.2.4.1: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) WHERE THE HORIZONTAL ASSEMBLY SEPARATES MIXED OCCUPANCIES, THE ASSEMBLY SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN THAT REQUIRED BY SECTION 508.4 BASED ONT HE OCCUPANCIES BEING SEPARATED ALLOWABLE: NO SEPARATION REQUIREMENT REQUIRED 711.3: NONFIRE-RESISTANCE-RATED FLOOR AND ROOF ASSEMBLIES NONFIRE-RESISTANCE-RATED FOOR, FLOOR/CEILING, ROOF AND ROOF/CEILING ASSEMBLIES SHALL COMPLY WITH SECTIONS 711.3.1 AND 711.3.2 713.4: FIRE-RESISTANCE RATING (SHAFT WALLS) SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIES OR MORE, AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES. THE NUMBER OF STORIES CONNECTED BY THE SHAFT ENCLOSURE SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES. SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED BUT NOT EXCEED 2 HOURS. SHAFT ENCLOSURES SHALL MEET THE REQUIREMENTS OF SECTION 703.2.1.1 713.6: EXTERIOR WALLS (SHAFT WALLS) WHERE EXTERIOR WALLS SERVE AS A PART OF A REQUIRED SHAFT ENCLOSURE, SUCH WALLS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 705 FOR EXTERIOR WALLS AND THE FIRE-RESISTANCE-RATED ENCLOSURE REQUIREMENTS SHALL NOT APPLY. CHAPTER 9: FIRE PROTECTION SYSTEMS 906.1: PORTABLE FIRE EXTINGUISHERS EXTINGUISHERS REQUIRED PER SECTION 906.1 906.2: GENERAL REQUIREMENTS PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH THIS SECTION AND CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, CHAPTER 3. 906.3 TABLE: SIZE AND DISTRIBUTIONS LOW HAZARD OCCUPANCY MIN-RATED SINGLE EXTINGUISHER 2-A EXTINGUISHER MAX FLOOR AREA FOR UNIT 3,000 SF MAX FLOOR AREA FOR EXTINGUISHER 11,250 SF MAX DISTANCE OF TRAVEL TO EXTINGUISHER 75'-0" REQUIRED: PROVIDED: 906.5: CONSPICUOUS LOCATION PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS LOCATIONS WHERE THEY WILL HAVE READY ACCESS AND BE IMMEDIATELY AVAILABLE FOR USE. THESE LOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL, UNLESS THE FIRE CODE OFFICIAL DETERMINES THAT THE HAZARD POSED INDICATES THE NEED FOR PLACEMENT AWAY FROM NORMAL PATHS OF TRAVEL. 907: FIRE ALARM AND DETECTION SYSTEMS GROUP B, M, & S: MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT NOTIFICATION APPLIANCES WILL AUTOMATICALLY ACTIVATE THROUGHOUT THE NOTIFICATION ZONES UPON SPRINKLER WATER FLOW. 911: FIRE COMMAND CENTER NOT REQUIRED FOR S-1 OCCUPANCY WITH A SIZE LESS THAN 500,000 SF CHAPTER 10: MEANS OF EGRESS 1003.2: CEILING HEIGHT THE MEANS OF EGRESS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7'-6" ABOVE THE FINISHED FLOOR EXCEPTIONS: - SLOPED CEILINGS IN ACCORDANCE WITH SECTION 1208.2 - ALLOWABLE PROJECTIONS IN ACCORDANCE WITH SECTION 1003.3 - STAIR HEADROOM IN ACCORDANCE WITH SECTION 1011.3 - DOOR HEIGHT IN ACCORDANCE WITH SECTION 1010.1.1 - RAMP HEADROOM IN ACCORDANCE WITH SECTION 1012.5.2 - AREAS ABOVE AND BELOW MEZZANINE FLOORS IN ACCORDANCE WITH SECTION 505.2 1004.4: MULTIPLE OCCUPANCIES WHERE A BUILDING CONTAINS TWO OR MORE OCCUPANCIES, THE MEANS OF EGRESS REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY OF THAT SPACE. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYTEMS, THOSE EGRESS COMPONENTS SHALL MEET THE MORE STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED. 1004.5: AREAS WITHOUT FIXED SEATING THE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT OF AREA AS PRESCRIBED IN TABLE 1004.5 FOR AREAS WITHOUT FIXED SEATING, THE OCCUPANT LOAD SHALL BE NOT LESS THAN THAT NUMBER DETERMINED BY DIVIDING THE FLOOR AREA UNDER CONSIDERATION BY THE OCCUPANT LOAD FACTOR ASSIGNED TO THE FUNCTION OF THE SPACE AS SET FORTH IN TABLE 1004.5 WHERE AN INTENDED FUNCTION IS NOT LISTED IN TABLE 1004.5, THE BUILDING OFFICIAL SHALL ESTABLISH A FUNCTION BASED ON A LISTED FUNCTION THAT MOST NEARLY RESEMBLES THE INTENDED FUNCTION. PER TABLE 1004.5 OFFICE SPACE, (BUSINESS AREAS) B: 150 GROSS/OCCUPANT RETAIL, M: 60 GROSS/OCCUPANT RETAIL STORAGE, M: 300 GROSS/OCCUPANT SELF-STORAGE, S-1: N/A (USING 500 GROSS FOR CALCULATIONS) PROPOSED: SEE SHEET PLANS - G203 & G204 1004.9 POSTING OF OCCUPANT LOAD EVERY ROOM OR SPACE WHICH IS USED FOR ASSEMBLY, CLASSROOM, DINING, DRINKING OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE, FOR THE INTENDED CONFIGURATIONS. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT. 1005.3: REQUIRED CAPACITY BASED ON OCCUPANT LOAD THE REQUIRED CAPACITY, IN INCHES (MM), OF THE MEANS OF EGRESS FOR ANY ROOM, AREA, SPACE OR STORY SHALL BE NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH SECTIONS 1005.3.1 AND 1005.3.2. 1005.3.1: STAIRWAYS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.3 INCH (7.6MM) PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE STAIRWAYS SERVING THAT STORY. REQ'D STAIR WIDTH: 36" MIN PROPOSED STAIR WIDTH: 38.5" MIN 1005.3.2: OTHER EGRESS COMPONENTS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1MM) PER OCCUPANT. PROPOSED: XXX OCCUPANTS / XXX EXITS = XXX XXX*.02= XXX MIN ALLOWED: 44" PER 1028.4 THE MIN WIDTH OR REQUIRED CAPACITY OF THE EXIT DISCHARGE SHALL BE NOT LESS THAN THE MINIMUM WIDTH ORREQUIRED CAPACITY OF THE EXITS BEING SERVED. BUILDING CODE SUMMARYAPPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 HERMOSA BEACH MUNICIPAL CODE (HBMC)OCCUPANCY CLASSIFICATION (302): BUSINESS: B MERCANTILE: M STORAGE: S-1CONSTRUCTION TYPE FOR EXISTING AND NEW PORTIONS OF PROJECT (601):TYPE: VB - 0 HOURFIRE SPRINKLER REQUIREMENTS (903):PER 903.2.7 - M OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM PER 903.2.9 - S1 OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM REQUIRED: FIRE SPRINKLER NOT REQUIRED PROPOSED: NFPA 13 SPRINKLER PROVIDEDGENERAL CODECHAPTER 5: BUILDING HEIGHT AND AREA504 - 506 TABLE: ALLOWABLE BUILDING HEIGHTS, STORIES ABOVE GRADE PLAN, AND AREAS: TYPE VB CONSTRUCTION / SPRINKLERED / B OCCUPANCY: 60' H / 3-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / M OCCUPANCY: 60' H / 2-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / S-1 OCCUPANCY: 60' H / 2-STORIES / 27,000 SF EXISTING HEIGHT / STORIES / AREA: 23.32' MIN - 24.48' MAX / 2 STORIES / 13,943 SFPROPOSED HEIGHT / STORIES / AREA: 28.81' MIN - 29.97' MAX / 3 STORIES / 13,885 SFCHAPTER 6: TYPES OF CONSTRUCTION601 TABLE: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS):PRIMARY STRUCTURAL FRAME 0 HR EXTERIOR BEARING WALLS 0 HR INTERIOR BEARING WALLS 0 HR INTERIOR NONBEARING WALLS AND PARTITIONS 0 HR FLOOR CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HRCHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES705.2: PROJECTIONSPROJECTS SHALL NOT EXTEND ANY CLOSER TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE THAN SHOWN IN TABLE 705.2705.2.2: TYPE III, IV, OR V CONSTRUCTIONPROJECTIONS FROM WALLS OF TYPE III, IV, OR V CONSTRUCTION SHALL BE OF ANY APPROVED MATERIAL705.5 FIRE-RESISTANCE RATINGSEXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION 601 AND 602. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF GREATER THAN 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF LESS THAN OR EQUAL TO 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. TABLE: FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (HOURS): GROUP B / TYPE VBLESS THAN 5'-0" 0 HR 5'-0" TO LESS THAN 10'-0" 0 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HRGROUP M & S-1 / TYPE VBLESS THAN 5'-0" 2 HR 5'-0" TO LESS THAN 10'-0" 1 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR EXISTING SEPARATION DISTANCE (SEE SITE PLAN A101)705.8: OPENINGSOPENINGS IN EXTERIOR WALLS SHALL COMPLY WITH SECTION 705.8.1 THROUGH 705.8.6705.8.1: ALLOWABLE AREA OF OPENINGS EXCEPTION 2: BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR NONBEARING WALLS AND EXTERIOR PRIMARYSTRUCTURAL FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED SHALL BE PERMITTED TO HAVE UNLIMITEDUNPROTECTED OPENINGS.705.8.5: VERTICAL SEPARATION OF OPENINGS EXCEPTION 2: THIS SECTION SHALL NOT APPLY TO BUILDINGS THAT ARE THREE STORIES OR LESS ABOVE GRADE PLAN EXCEPTION 3: THIS SECTION SHALL NOT APPLY TO BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEMIN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.1.2705.11: PARAPETS PARAPETS SHALL BE PROVIDED ON EXTERIOR WALLS OF BUILDINGS EXCEPTION: A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF THE FOLLOWING CONDITIONS ARE MET - THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 705.5 BECAUSE OF FIRE SEPARATION DISTANCE708.6: OPENINGS (EXTERIOR WALL) OPENINGS IN A FIRE PARTITIONS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716708.7: PENETRATIONS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION SHALL COMPLY WITH SECTION 714708.9: DUCTS AND AIR TRANSFER OPENINGS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION BY DUCTS AND AIR TRANSFER OPENINGS SHALL COMPLY WITH SECTION 717711.2.3: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) THE SUPPORTING CONSTRUCTION SHALL BE PROTECTED TO AFFORD THE REQUIRED FIRE-RESISTANCE RATING OF THEHORIZONTAL ASSEMBLY SUPPORTED EXCEPTION: IN BUILDINGS OF TYPE IIB, IIIB, OR VB CONSTRUCTION, THE CONSTRUCTION SUPPORTING THE HORIZONTALASSEMBLY IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED AT THE FOLLOWING: - HORIZONTAL ASSEMBLIES AT THE SEPARATIONS OF INCIDENTAL USES AS SPECIFIED BY TABLE 509.1 PROVIDED THAT THEREQUIRED FIRE-RESISTANCE RATING DOES NOT EXCEED 1 HOUR. - HORIZONTAL ASSEMBLIES AT SMOKE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 709711.2.4.1: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) WHERE THE HORIZONTAL ASSEMBLY SEPARATES MIXED OCCUPANCIES, THE ASSEMBLY SHALL HAVE A FIRE-RESISTANCE RATINGOF NOT LESS THAN THAT REQUIRED BY SECTION 508.4 BASED ONT HE OCCUPANCIES BEING SEPARATED ALLOWABLE: NO SEPARATION REQUIREMENT REQUIRED711.3: NONFIRE-RESISTANCE-RATED FLOOR AND ROOF ASSEMBLIES NONFIRE-RESISTANCE-RATED FOOR, FLOOR/CEILING, ROOF AND ROOF/CEILING ASSEMBLIES SHALL COMPLY WITH SECTIONS711.3.1 AND 711.3.2 713.4: FIRE-RESISTANCE RATING (SHAFT WALLS) SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIESOR MORE, AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES. THE NUMBER OF STORIES CONNECTEDBY THE SHAFT ENCLOSURE SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES. SHAFT ENCLOSURES SHALL HAVE AFIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED BUT NOT EXCEED 2 HOURS. SHAFT ENCLOSURESSHALL MEET THE REQUIREMENTS OF SECTION 703.2.1.1 713.6: EXTERIOR WALLS (SHAFT WALLS) WHERE EXTERIOR WALLS SERVE AS A PART OF A REQUIRED SHAFT ENCLOSURE, SUCH WALLS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 705 FOR EXTERIOR WALLS AND THE FIRE-RESISTANCE-RATED ENCLOSURE REQUIREMENTS SHALL NOT APPLY. CHAPTER 9: FIRE PROTECTION SYSTEMS 906.1: PORTABLE FIRE EXTINGUISHERS EXTINGUISHERS REQUIRED PER SECTION 906.1 906.2: GENERAL REQUIREMENTS PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH THIS SECTION AND CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, CHAPTER 3. 906.3 TABLE: SIZE AND DISTRIBUTIONS LOW HAZARD OCCUPANCY MIN-RATED SINGLE EXTINGUISHER 2-A EXTINGUISHER MAX FLOOR AREA FOR UNIT 3,000 SF MAX FLOOR AREA FOR EXTINGUISHER 11,250 SF MAX DISTANCE OF TRAVEL TO EXTINGUISHER 75'-0" REQUIRED: PROVIDED: 906.5: CONSPICUOUS LOCATION PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS LOCATIONS WHERE THEY WILL HAVE READY ACCESS AND BE IMMEDIATELY AVAILABLE FOR USE. THESE LOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL, UNLESS THE FIRE CODE OFFICIAL DETERMINES THAT THE HAZARD POSED INDICATES THE NEED FOR PLACEMENT AWAY FROM NORMAL PATHS OF TRAVEL. 907: FIRE ALARM AND DETECTION SYSTEMS GROUP B, M, & S: MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT NOTIFICATION APPLIANCES WILL AUTOMATICALLY ACTIVATE THROUGHOUT THE NOTIFICATION ZONES UPON SPRINKLER WATER FLOW. 911: FIRE COMMAND CENTER NOT REQUIRED FOR S-1 OCCUPANCY WITH A SIZE LESS THAN 500,000 SF CHAPTER 10: MEANS OF EGRESS 1003.2: CEILING HEIGHT THE MEANS OF EGRESS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7'-6" ABOVE THE FINISHED FLOOR EXCEPTIONS: - SLOPED CEILINGS IN ACCORDANCE WITH SECTION 1208.2 - ALLOWABLE PROJECTIONS IN ACCORDANCE WITH SECTION 1003.3 - STAIR HEADROOM IN ACCORDANCE WITH SECTION 1011.3 - DOOR HEIGHT IN ACCORDANCE WITH SECTION 1010.1.1 - RAMP HEADROOM IN ACCORDANCE WITH SECTION 1012.5.2 - AREAS ABOVE AND BELOW MEZZANINE FLOORS IN ACCORDANCE WITH SECTION 505.2 1004.4: MULTIPLE OCCUPANCIES WHERE A BUILDING CONTAINS TWO OR MORE OCCUPANCIES, THE MEANS OF EGRESS REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY OF THAT SPACE. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYTEMS, THOSE EGRESS COMPONENTS SHALL MEET THE MORE STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED. 1004.5: AREAS WITHOUT FIXED SEATING THE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT OF AREA AS PRESCRIBED IN TABLE 1004.5 FOR AREAS WITHOUT FIXED SEATING, THE OCCUPANT LOAD SHALL BE NOT LESS THAN THAT NUMBER DETERMINED BY DIVIDING THE FLOOR AREA UNDER CONSIDERATION BY THE OCCUPANT LOAD FACTOR ASSIGNED TO THE FUNCTION OF THE SPACE AS SET FORTH IN TABLE 1004.5 WHERE AN INTENDED FUNCTION IS NOT LISTED IN TABLE 1004.5, THE BUILDING OFFICIAL SHALL ESTABLISH A FUNCTION BASED ON A LISTED FUNCTION THAT MOST NEARLY RESEMBLES THE INTENDED FUNCTION. PER TABLE 1004.5 OFFICE SPACE, (BUSINESS AREAS) B: 150 GROSS/OCCUPANT RETAIL, M: 60 GROSS/OCCUPANT RETAIL STORAGE, M: 300 GROSS/OCCUPANT SELF-STORAGE, S-1: N/A (USING 500 GROSS FOR CALCULATIONS) PROPOSED: SEE SHEET PLANS - G203 & G204 1004.9 POSTING OF OCCUPANT LOAD EVERY ROOM OR SPACE WHICH IS USED FOR ASSEMBLY, CLASSROOM, DINING, DRINKING OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE, FOR THE INTENDED CONFIGURATIONS. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT. 1005.3: REQUIRED CAPACITY BASED ON OCCUPANT LOAD THE REQUIRED CAPACITY, IN INCHES (MM), OF THE MEANS OF EGRESS FOR ANY ROOM, AREA, SPACE OR STORY SHALL BE NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH SECTIONS 1005.3.1 AND 1005.3.2. 1005.3.1: STAIRWAYS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.3 INCH (7.6MM) PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE STAIRWAYS SERVING THAT STORY. REQ'D STAIR WIDTH: 36" MIN PROPOSED STAIR WIDTH: 38.5" MIN 1005.3.2: OTHER EGRESS COMPONENTS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYINGTHE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1MM) PER OCCUPANT. PROPOSED: XXX OCCUPANTS / XXX EXITS = XXX XXX*.02= XXX MIN ALLOWED: 44" PER 1028.4 THE MIN WIDTH OR REQUIRED CAPACITY OF THE EXIT DISCHARGE SHALL BE NOT LESS THAN THE MINIMUM WIDTH OR REQUIRED CAPACITY OF THE EXITS BEING SERVED. 1005.7.1 DOORS DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7 INCHES (178MM). DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF. 1006.1: NUMBER OF EXITS AND EXIT ACCESS DOORWAYS: MAXIMUM OCCUPANT LOAD OF SPACE: SEE SHEET G204 MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE: A/M OCCUPANCY : 75' (W/ SPRINKLER SYSTEM) B OCCUPANCY: 100' (W/ SPRINKLER SYSTEM) S OCCUPANCY: 100' (W/ SPRINKLER SYSTEM) 1006.3.3: EGRESS BASED ON OCCUPANT LOAD EACH STORY AND OCCUPIED ROOF SHAL HAVE THE MIN NUMBER OF SEPARATE AND DISTINCT EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.3. A SINGLE EXIT OR ACCESS TO A SINGLE EXIT SHALL BE PERMITTED IN ACCORDANCE WITH SECTION 1006.3.4. THE REQUIRED NUMBER OF EXITS, OR EXIT ACCESS STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT DISCHARGE OR A PUBLIC WAY. 1-500 OCC LOAD EXIT(S) PER STORY: 2 EXITS REQ'D PROPOSED: 2 EXITS 1007.1.1: TWO EXITS OR EXIT ACCESS DOORWAYS WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE- HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN THEM. INTERLOCKING OR SCISSOR STAIRWAYS SHALL BE COUNTED AS ONE EXIT STAIRWAY. EXCEPTION 2: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. SEE SHEET G205 FOR EGRESS DIAGRAMS 1008.2: ILLUMINATION REQUIRED THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE ISOCCUPIED. 1008.2: ILLUMINATION LEVEL UNDER NORMAL POWER THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 FOOTCANDLE (11 LUX) AT THE WALKING SURFACE. ALONG EXIT ACCESS STAIRWAYS, EXIT STAIRWAYS, AND AT THEIR REQUIRED LANDINGS, THE ILLUMINATION LEVEL SHALL NOT BE LESS THAN 10 FOOTCANDLES (108 LUX) AT THE WALKING SURFACE WHEN THE STAIRWAY IS IN USE. 1008.3: EMERGENCY POWER FOR ILLUMINATION THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. EMERGENCY ILLUMINATION TO BE IN ACCORDANCE WITH SECTION 1008.3.1-5 1008.3.3 ROOMS AND SPACES IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: ELECTRICAL EQUIPMENT ROOMS, FIRE COMMAND CENTERS, FIRE PUMP ROOMS, GENERATOR ROOMS, PUBLIC RESTROOMS WITH AN AREA GREATER THAN 300 SF 1008.3.4 DURATION THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. SCALE: 3/32" = 1'-0"1 EXIT SEPARATION - FIRST FLOOR SCALE: 3/32" = 1'-0"2 EXIT SEPARATION - SECOND FLOOR SCALE: 3/32" = 1'-0"3 EXIT SEPARATION - THIRD FLOOR EXIT SEPARATION: DIAGONAL = 81'-4" PROPOSED = 39'-7" ALLOWABLE MINIMUM = 27'-1" DOOR SEPARATION: DIAGONAL = 51'-5" PROPOSED = 29'-0" ALLOWABLE MINIMUM = 17'-1" EXIT SEPARATION: DIAGONAL = 103'-5" PROPOSED = 67'-9" ALLOWABLE MINIMUM = 34'-5" *CBC 2022 1007.1.1 EXCEPTION #2 WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. Page 115 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 22 OF 141 G-204 CODE PLANS & SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10123456789101112131415161718UP18 RISERS (6 23/32") 5G-204 5G-204 6'-0"6'-0"6'-0" 6'-0"7'-6 1/4"5'-0"5'-0"5'-3" 2'-10 1/4"2'-10 1/4"2'-10 1/4"3'-3 1/4"3'-2 1/4" TRAVEL DISTANCE = 79'-0" TRAVEL DISTANCE = 87'-0" EXIT 1 EXIT 2 EXIT 3 EXIT 4EXIT 5EXIT 6EXIT 7EXIT 9 EXIT 8 TRAVEL DISTANCE = 29'-0" TRAVEL DISTANCE = 23'-0" RETAIL 104RETAIL 105 WINE STORAGE112 LOADING ZONE115 OFFICE110 STORAGE113 ELEVATOR 01 RSTRM 106 RSTRM 103 STAIR 02 114 STAIR 01 121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE 111 RETAIL 101 HALL 102 ELEV RM121 ELECTRIC RM120 TRANSFORMER 121 4G-204 4G-204 1234567 8 UP 20 RISERS (7") RESTRM 108 ACC. RSTRM 109 TRASH RM 119 DN 5G-204 5G-2045'-0"3'-8"25'-0"5'-0"5'-0"4'-1"3'-8"EXITACCESS TRAVEL DISTANCE = 44'-5" OPEN TO BELOWOPEN TO BELOW OPEN TO BELOW EXIT ACCESS TRAVEL DISTANCE = 71'-9"EXIT ACCESS TRAVELDISTANCE = 59'-0"TRAVEL DISTANCE = 33'-6" OPEN TO BELOW OFFICE207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 4G-204 4G-204 DN 123456 7UP 12 RISERS (6 1/2")12345678910111213141516 UP 16 RISERS (6 25/32") SK-1 SK-2 SK-3 F DW F 5G-204 5G-204 4G-204 4G-204 5'-0"3'-6"5'-0"3'-0"3'-2 1/2"45" CLR2'-8"EXIT ACCESS TRAVEL DISTANCE = 79'-0" ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM 314 OFFICE 309 OFFICE304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM317 GARDEN311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN GREEN ROOF 307 LIFE SAFETY LEGEND EXIT ACCESS TRAVEL DISTANCE 1 HOUR RATED SEPARATION 2 HOUR RATED SEPARATION 3 HOUR RATED SEPARATION EXIT EXITS PER OCCUPANT LOAD EXIT 1: 2 OCCUPANTS EXIT 2: 2 OCCUPANTS EXIT 3: 31/2 = 16 TOTAL OCCUPANTS FROM BUSINESS LEVEL 3 6 TOTAL OCCUPANTS FROM BUSINESS LEVEL 2 1 TOTAL OCCUPANTS FROM BUSINESS LEVEL 1 23 TOTAL OCCUPANTS EXIT 4: 14/2 = 7 TOTAL OCCUPANTS FROM RETAIL 105 3/2 = 1.5 TOTAL OCCUPANTS FROM STORAGE 112 8.5 OCCUPANTS = 9 TOTAL OCCUPANTS EXIT 5: 14/2 = 7 TOTAL OCCUPANTS FROM RETAIL 105 3/2 = 1.5 TOTAL OCCUPANTS FROM STORAGE 112 8.5 OCCUPANTS = 9 TOTAL OCCUPANTS EXIT 6: 9 OCCUPANTS EXIT 7: 12 OCCUPANTS EXIT 8: 10/2 EXITS = 5 OCCUPANTS FROM STORAGE LEVEL 2 12 TOTAL OCCUPANTS FROM STORAGE 113 17 TOTAL OCCUPANTS EXIT 9:31/2 EXITS = 16 TOTAL OCCUPANTS FROM BUSINESS LEVEL 3 10/2 EXITS = 5 TOTAL OCCUPANTS FROM STORAGE LEVEL 2 21 TOTAL OCCUPANTS EXIT # GENERAL NOTES *ALL DOORS TO BE SIZED IN ACCORDANCE TO SECTION 1005.3.2 OF CBC *DEAD END CORRIDORS NOT TO EXCEED 50' IN ACCORDANCE TO SECTION 1020.5 OF CBC *TRAVEL DISTANCE SHALL NOT EXCEED 205 FT. FOR BUILDINGS SPRINKLED THROUGHOUT PER CBC SECTION 1004.2.3.2.2 (M) MERCANTILE OCCUPANT LEGEND (B) BUSINESS (S-1) STORAGE FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' -3.13'FOUNDATION -3.13'FOUNDATION ±0.00'1ST FLOOR ±0.00'1ST FLOOR +9.13'2ND FLOOR - STORAGE +9.13'2ND FLOOR - STORAGE +11.67'2ND FLOOR - OFFICE +11.67'2ND FLOOR - OFFICE +18.17'3RD FLOOR +18.17'3RD FLOOR +23.17'GARDEN ROOF +23.17'GARDEN ROOF +28.79'ROOF +28.79'ROOF SCALE: 3/32" = 1'-0"1 FIRST FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0"2 SECOND FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0"3 THIRD FLOOR LIFE SAFETY PLAN SCALE: 1/8" = 1'-0"5 BUILDING SECTION - NORTH/SOUTH 0 4'8'16' SCALE: 1/8" = 1'-0"4 BUILDING SECTION - EAST/WEST 0 4'8'16' RETAIL 105 (M) 817 SF 817/60 = 14 OCCUPANTS RETAIL 104 (M) 528 SF 528/60 = 9 OCCUPANTS RETAIL 101 (M) 708 SF 708/60 = 12 OCCUPANTS OFFICE 110 (B) 249SF 249/150 = 2 OCCUPANTS OFFICE 111 (B) 245 SF 245/150 = 2 OCCUPANTS LOBBY 107 (B) 122 SF 122/150 = 1 OCCUPANTS STORAGE 112 (S-1) 769 SF 769/300 = 3 OCCUPANTS TOTAL TRAVEL DISTANCE: 79'-0" STORAGE 02 (S-1) 2,685 SF 2,685/300 = 9 OCCUPANTS TOTAL TRAVEL DISTANCE: 87'-0" OFFICE 207 (B) 161 SF 161/150 = 2 OCCUUPANTS OFFICE 206 (B) 156 SF 156/150 = 2 OCCUUPANTS OFFICE 205 (B) 154 SF 154/150 = 2 OCCUUPANTS STORAGE 210 (S-1) 2,687 SF 2,687/300 = 9 OCCUUPANTS TOTAL TRAVEL DISTANCE: 86'-0" OFFICE (B) 4,611 SF 4,611/150 = 31 OCCUUPANTS TOTAL TRAVEL DISTANCE: 79'-0" *ALL DOORS TO BE SIZED IN ACCORDANCE TO SECTION 1005.3.2 Page 116 of 324 ANY CHANGES OR MODIFICATIONS MADE TO THIS PLAN WITHOUT WRITTEN CONSENT OF DENN ENGINEERS SHALL RELIEVE DENN ENGINEERS FROM ANY LIABILITY OR DAMAGE RESULTING FROM SUCH CHANGES OR MODIFICATIONS, INCLUDING ANY ATTORNEYS FEES OR COSTS INCURRED IN ANY PROCEEDING THAT DENN ENGINEERS MAY BE JOINED. CONCRETE BRICK 106.76 EXISTING ELEVATION BLOCK WALL LEGEND 100 EXISTING CONTOUR X EXISTING FENCE EXISTING BUILDING WOOD DECK THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF PROFESSIONAL LAND SURVEYORS' ACT R.C.E. 30826GARY J. ROEHL 3914 DEL AMO BLVD, SUITE 921 TORRANCE, CA 90503 (310) 542-9433 E N G IN E E R S JOB ADDRESS LEGAL DESCRIPTION FOR DRAWN BY CHECK BY SHEET 1 OF 1 DRAWN ON REVISIONS COPYRIGHT JOB NO. BCR BEGINNING OF CURB RETURN CATV CABLE TV PULL BOX CONC.CONCRETE CHMNY CHIMNEY CEFB CITY ENGINEERS FIELD BOOK C/L CENTERLINE C.L.F. / W.I.F.CHAIN LINK FENCE / WROUGHT IRON FENCE E'LY EASTERLY EG EDGE OF GUTTER EM ELECTRIC METER FF FINISH FLOOR FH FIRE HYDRANT FL FLOW LINE GFF GARAGE FINISH FLOOR GM GAS METER GUY / GW GUY WIRE I.P. IRON PIPE MONUMENT L&T LEAD AND TACK / TAG MONUMENT MH MANHOLE ( SANITARY SEWER / STORM DRAIN) N'LY NORTHERLY N&T NAIL AND TAG MONUMENT PB PULL BOX ( EDISON / TRAFFIC / STREET LIGHT PB (CONT)TELEPHONE / CABLE TV) PC PROPERTY CORNER / PROP. CORNER PL PROPERTY LINE / PROP. LINE PP / UP POWER POLE / UTILITY POLE PPT PARAPET PWFB PUBLIC WORKS FIELD BOOK R.R.RAIL ROAD RDFB ROAD DEPARTMENT FIELD BOOK R.S.RECORD OF SURVEY SPK / S&W SPIKE / SPIKE AND WASHER MONUMENT S'LY SOUTHERLY SSCO SANITARY SEWER CLEANOUT STK / STK&T STAKE / STAKE AND TAG MONUMENT STLT / LT STREET LIGHT POLE / LIGHT POLE TC TOP OF CURB TX / BX TOP OF APRON / BOTTOM OF APRON W'LY WESTERLY WM WATER METER BOUNDARY MONUMENTS ARE NOT NECESSARILY SET ON PROPERTY CORNERS. PLEASE REFER TO THE NOTATION ON THIS SURVEY PLAT FOR OFFSET DIMENSIONS. IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT DENN ENGINEERS FOR CLARIFICATION BY PHONE AT: (310) 542-9433, M-F 8:00 AM TO 5:00 PM. NOTE: ALL SETBACK DIMENSIONS SHOWN ARE MEASURED TO EXTERIOR SURFACE OF BUILDINGS UNLESS OTHERWISE NOTED. 901 HERMOSA AVENUE HERMOSA BEACH, CA 90254 LOT 25,26 AND 27, BLOCK 10 HERMOSA BEACH M.B. 1-25-26 APN 4187-003-028 SURVEY AND TOPOGRAHY FM GR SCALE 1" = 8' FEBRUARY 10, 2022 REVISIONS NORTH22-006 CARDINAL INVESTMENTS 2301 ROSECRANS AVENUE, SUITE 4130 EL SEGUNDO, CA, 90254 PHONE N 77°25'58"E 86.17'N 12°10'00"W95.11'N 77°26'20"E 86.16'N 12°10'00"W95.10'N 77°25'58"E 334.16'N 12°10'00"W135.11'N 77°26'20"E 323.80' 10TH COURT 9TH STREET HERMOSA AVENUE10.00'30.00'30.00'KYLE RANSFORD SET L&T RCE 30826 3.00' E'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=16.40' SET L&T RCE 30826 3.00' E'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=16.00' FOUND N&T RCE 30826 0.95' N'LY & 0.11' W'LY OF PROP. CORNER TAG ELEV.=15.24' FOUND L&T RCE 30826 23.00' S'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=15.19' 217.63' 20.00' 20.00' 227.99'16.2616.4915.2915.1115.78 TC15.20 FLCATV 15.30ED BOX 16.22 TC15.59 FLCATV15.8116.54 TC16.06 FL 16.2016.21 TX 15.88 FL 15.98 EG SIGN PARKING METER 15.892"GUARD POST 16.172"GUARD POST 16.122"GUARD POST 16.092"GUARD POST16.082"GUARD POST 16.142"GUARD POST 16.088"POST 16 . 9 9 16.0716.1216.0416.0416.35 TX 16.01 FL16.13 EG PARKING METER 16.2916.0916.0616.56 FF16.0516.0515.92 FF8"TREE 15.6215.7515.2215.3115.4117.54 TW 15.44 PC15.9015.9239 . 2 6 P A R A P E T 36.61 PARAPET32.46 PARAPET16.57 FF16.40 TC 16.10 FL PARKING METER 16.4215.2415.2116.56 PC16.44 SIGN 16.3716.2516.36 FL 16.44 TC 16.13 FL16.26 EG WV16.35WV 16.41FH 16.47SSMH16.2915.93 FF15.53TEL BOX 15.34WM15.2115.2415.4415.52EBOX 3*4 15.3215.4016.3615.6515.8315.8115.91 17.03 17.03 16.02 22.87 TW15.5416.9917.0416.5015.70N 16°33'18"W135.40'BEACH DRIVECONC. GUTTERCONC. SIDEWALK100' 20'80' FOUND PK NAIL PER R.S. 134-78 STA. 0+00.00STA. 0+38.192.8'20'10'10'60'30'30'20' 10'10' FOUNT 4 PM's IN MANHOLE RIM PER PWFB 0616-1732,1733 STA. 3+34.16 FOUND L&T 5909 ACCEPTED AS C/L INT. PER PWFB 0616-1732,1733 FOUND NAIL PER R.S. 134-78 CONC. CURB BUILDING IS 0.05' S'LY OF PROP. LINE. BUILDING IS 0.29' N'LY OF PROP. LINE BUILDING IS 0.27' N'LY OF PROP. LINE BUILDING IS 0.14' E'LY OF PROP. LINE BUILDING IS 0.09' E'LY OF PROP. LINE EXISTING RESIDENCE EXISTING RESIDENCE 58 10TH COURT APN 4187-003-027 LOT 24 LOT 25 LOT 26 LOT 27 30.00'95.11'10.00'106.17' 106.17' NOTE: A TITLE POLICY WAS NOT PROVIDED TO DENN ENGINEERS AT THE TIME OF THIS SURVEY. THEREFORE, DENN ENGINEERS DOES NOT GUARANTEE THE LEGAL DESCRIPTION OF THIS PROPERTY SURVEYED NOR DOES IT REFLECT OR DELINEATE ANY EASEMENTS THAT MAY BE ON SAID PROPERTY. Page 117 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 27 OF 141 AD-101 DEMOLITION SITE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 PL PL 05 06 12 02 07 01 HERMOSA AVENUE 10TH COURT9TH STREET(E) NEIGHBORING BUILDING (E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDINGABV PLPL PL PL PL PL 08 901 HERMOSA AVE (E) BUILDING FOOTPRINT 7,756 SQ FT 01 02 03 04 05 06 07 08 09 EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED EXISTING CONCRETE CURB TO BE REMOVED EXISTING COLUMN TO BE REMOVED EXISTING PLANTER BOX TO BE REMOVED EXISTING HARDSCAPE TO BE REMOVED EXISTING UTILITY BOX TO BE REMOVED. UTILITIES TO BE RELOCATED. EXISTING TREE TO BE REMOVED EXISTING BOLLARDS TO BE REMOVED SCALE: 3/16" = 1'-0"1 DEMO SITE PLAN 0 4'8'12' Page 118 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 28 OF 141 AD-111 DEMOLITION 1st FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 #DrgID #LayID 1 PERM 1 A-201 2 A-201 4'-2"7"10'-5"4'-7 1/2"8'-2"2'-0"8'-2"1'-9"4'-2 1/4"9'-2 1/2"3'-5 1/4"26'-9 1/2"2 1'-0" VIF 13'-2" 01 14 02 04 03 03 03 03 030303 07 07 04 04 04 04 04 07 07 04 04 04 16 19 19 19 19 13 13 0101 070707 16 16161616 1616 1616 15 19 07 08 08VIF VIFPL PL SB PL PL PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS EXISTING STAIRS TO BE REMOVED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS 10 10 SCALE: 1/4" = 1'-0"1 1st FLOOR DEMOLITION PLAN 0 2'4'8' Page 119 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 29 OF 141 AD-112 DEMOLITION 2nd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 #DrgID #LayID 1 PERM 1 A-201 2 A-201 04 01 04 030303040413 03 04 03 03 07 07 03 010101 0101 01 19 19 19 08 08 PL PL PL PL SB SB PL PL PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS EXISTING STAIRS TO BE REMOVED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS 10 10 SCALE: 1/4" = 1'-0"1 2nd FLOOR DEMOLITION PLAN 0 2'4'8' Page 120 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 30 OF 141 AD-113 DEMOLITION ROOF PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 PL PL PL PL 1 A-201 2 A-201 1 PERM #DrgID #LayID 04 05 06 05 05 PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS EXISTING STAIRS TO BE REMOVED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS SCALE: 1/4" = 1'-0"1 DEMOLITION ROOF PLAN Page 121 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 31 OF 141 C-000 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnTITLE SHEET ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-000 TITLE SHEET N N “” “” “” “” ” ” “ ” “ ” Page 122 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 32 OF 141 C-100 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnEROSION CONTROL PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARINGN 77°25'58"E86.17'N 12°10'00"W95.11'N 77°26'20"E86.16'N 12°10'00"W95.10'N 77°25'58"E334.16'N 12°10'00"W135.11'N 77°26'20"E323.80'10.00' 30.00' 30.00'20.00'20.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 100'20'80'2.8'20'10'10'60'30'30'30.00'95.11'10.00'106.17'106.17'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-100 EROSION CONTROL PLAN Page 123 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 33 OF 141 C-210 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnGRADING AND DRAINAGE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 30.00'1 6 . 2 6 15.291 5 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16 . 1 22"GUARD POST1 6 . 0 92"GUARD POST16 . 0 82"GUARD POST1 6 . 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16 . 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 1 6 . 0 9 1 6 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE1 5 . 6 2 1 5 . 7 5 1 5 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 1 5 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 1 6 . 5 7 F F 16.40 TC16.10 FLPARKING METER16 . 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 1 6 . 2 516.36 FL16.44 TC16.13 FL16.26 EGWV1 6 . 3 5 WV1 6 . 4 1SSMH1 6 . 2 9 15 . 9 3 F F 1 5 . 5 3TEL BOX1 5 . 3 4WM15 . 2 1 1 5 . 2 4 1 5 . 4 4 1 5 . 5 2EBOX 3*415.321 5 . 4 0 16.36 1 5 . 6 5 1 5 . 8 3 1 5 . 8 115.9117.0317.0316.022 2 . 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16. 2 2 50 0 8 LT NT16. 2 2 50 1 0 LT NT16. 2 4 50 2 8 16. 2 2 50 3 2 16. 6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-210 GRADING AND DRAINAGE PLAN Page 124 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 34 OF 141 C-300 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnLOW IMPACT DEVELOPMENT PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 30.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-300 LOW IMPACT DEVELOPMENT PLAN Page 125 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 35 OF 141 C-400 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnUTILITY PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 30.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-400 UTILITY PLAN Page 126 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 65 OF 141 A-101 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnSITE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 (E) SEWER (E) FIRE HYDRANT (E) CURB CUT PER SURVEY (E) EDISON BOX (N) TRASH ENCLOSURE (E) WATER METER SLOPE NOT TO EXCEED 6.67% (N) FIRE ROOM ENCLOSURE PROPOSED CONCRETE PLANTER NOT TO EXCEED 42" (E) CATV BOX (E) ELECTRICAL BOX (E) TELEPHONE BOX PROPOSED CONCRETE BENCH NOT TO EXCEED 20" (N) TRANSFORMER ENCLOSURE CLCL PC 15.44'PC 15.24' PC 15.98' 11"83'-4"95'-1 1/4" 8'-1" WALKSTREET 21'-10 1/2" ENCROACHMENT 86'-2"16.35 TX EG 15.59 06 07 01 02 04 10 16.01 FL 5X5 10TH COURT5X5 5X5 5X5 5X5 5X10 5X5 5X5 5X10 5X10 5X5 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X105X10 5X5 5X5 5X15 2% SLOPE MAX ENTRY ENTRY ENTRY E N T R YENTRYENTRYENTRY ENTRYOPEN TO ABOVE SIM HERMOSA AVE 5X5 9TH STREETPLPL PL PL WS WS SBSB PL PL PL PL PC 16.56' 39.26' TO PARAPET 39.26' TO PARAPET FF 16.56' FF 16.57' FF 15.93' 32.46' FF 16.56' 16.09' 16.06' 10'-0"2'-11"20'-1/2"29'-11 1/2"5'-10"24'-3 1/4"FF 16.56' 32.46' TO PARAPET FF 16.56' FF 16.56' 03 THIRD STORY SETBACK ABOVE 05 12 11 08 14 SECOND STORY SETBACK ABOVE 901 HERMOSA AVE (E) BUILDING FOOTPRINT 7,756 SQ FT (E) NEIGHBORING BUILDING (E) CONCRETE SIDEWALK (E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDINGSCALE: 3/16" = 1'-0"1 SITE PLAN 0 4'8'12' Page 127 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 66 OF 141 A-111 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnFOUNDATION PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 5 5 9 1/4" 2'-2 3/4"2'-1/2"HSS F5 F6 F6 F5 F5 F5 F5 F5 F5F5F4 F4 W12B W10B W8A W10B W10B W10B W10A TYP. ELEV. PIT ELEV. PIT2'-4 1/2"2'-7 1/2"3'-0"3'-0"2'-0"3'-3/4"2'-4 1/4"1'-1 3/4"1'-3/4"2'-5 1/4"5'-5"5'-5"6'-9 1/4"6'-8 3/4"1'-3/4"2'-5 1/4"6'-9"6'-9"1'-1/2"2'-5 1/2"7'-11 3/4" 1'-1/4"11 3/4"7'-11 3/4"8 1/4"2'-11 1/2"3'-2"2'-10"3'-3/4"6'-0"1'-10 1/2"2'-0"2'-0" PL PL PL PL SB SB 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 GRADE BEAM, SEE STRUCTUAL SET CONCRETE WALL, SEE STRUCTURAL SET TURN DOWN SLAB EDGE, SEE STRUCTURAL SET TYPICAL CONCRETE FOOTING, SEE STRUCTURAL SET EXISTING FOUNDATION STRUCTURAL WALL & COLUMN TAG, SEE STRUCTURAL SET INDICATES CHANGE IN FLOOR ELEVATION, SEE STRUCTURAL SET xx SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN 0 2'4'8' Page 128 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 67 OF 141 A-112 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln1st FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING115.2119.1118.1101.B104.A105.A 105.B107.1102.1102.2106.1121.1109.1108.1 103.1 120.1 115.1110.A 111.A111.1111.2110.2110.1101.1104.1 10 5.2 114.1115.3101.A 119.1123456789101112131415161718UP18 RISERS (6 23/32") 5 5CL121.1105.1 1 A-403 8 A-908 2 A-204 1 A-204 1 A-203 PC 15.98' PC 15.56' PC 15.24' PC 15.44'9 1/2"81'-11"3'-5 1/2"7 1/2"7" 94'-2"2'-10 3/4"7'-9 1/2"CLR5'-0"5'-0" 5'-0"5'-0"5'-5 1/2"2'-8 3/4" RO 10" 6'-6 1/4" F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. -1.00' = 15.50' F.F. -0.97' = 15.53'3'-8"CLR2'-0"3'-1 1/2"R.O.14'-1/4"6'-8 3/4"3'-9"5'-1 1/2" F.F. 0.00' = 16.56' 6'-11 1/2"12'-1/4"55'-0"9'-3 1/4"10'-11" VIF 7'-2"9'-2 1/2"RO1'-7"8'-6 3/4"5'-5"14'-11"14'-11"EG 15.75 EG 15.53 20'-2"4'-8 1/2"3'-1 1/2" R.O. 1'-3/4" 9'-1/4" 1'-1/4" 3'-4 1/4"19'-9"3'-3 1/2" R.O. 10'-9"7'-1/2"8'-2" R.O.2'-0"8'-2" R.O.6'-1 1/4"4'-7 1/2"10'-5"R.O.4'-2 1/2"9 1/2"10"2'-1/2"10'-7 1/2"RO1'-4"10'-7 1/2"RO2'-8"2 1'-0" R O VIF 21'-1/2" RO VIF 1'-11"3'-3" F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56'3'-8" CLEAR3'-2 1/2"R.O.8 1/2"11'-3/4"3'-2 1/4"R.O.14'-6 3/4" F.F. 0.00' = 16.56'2'-10 1/4"6 3/4"4'-7"RO5'-1 1/4"26'-8 1/2"11'-5"28'-1/2"15'-9"2'-10 3/4"RO5'-8"0 3/4"3'-2 1/4" R.O.7'-10 3/4"4'-2"R.O.4"8'-4 3/4"5'-11 1/2" 8'-4"CLR 3"3'-0"CLEAR3'-0"CLEAR4'-6 1/2" CLEAR F.F. 0.00' = 16.50'WT02-CWT07-B WT07-B WT07-BWT08-B WT05WT09-CWT10-A WT07-B WT07-BWT12 WT06 WT07-B WT07-BWT07-A WT07-BWT10-A WT02- A WT02-A WT11WT07-BWT07-AALIGNALIGNALIGNALIGN WT07-BWT07-BWT06WT11WT11 WT06WT06WT06WT02-C WT02-CWT10-BWT09-BALIGNALIGN WT03-AWT02-BALIGNALIGNWT02-CWT09-C WT03-B WT02-AWT02-AWT06WT02-CWT02-CWT06WT13 WT13WT06WT06 WT06 WT06 5X5 10TH COURT5X5 5X5 5X5 5X5 5X10 5X5 5X5 5X10 5X10 5X5 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X105X10 5X5 5X5 METER/ DIST. METER/ DIST. PULL/ MAIN 5X15 EP2% SLOPE MAX OPEN TO ABOVE WIRE WAY METER/ DIST. SIM CONTROLLER5X5 6'x8' RETAIL 104 RETAIL 105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM 106 RSTRM 103 STAIR 02 114 STAIR 01 121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE 111 RETAIL 101 HALL 102 ELEV RM 121 ELECTRIC RM 120 TRANSFORMER 121 3 A-203 #DrgID #LayID 105.3 112.11234567 8 UP 20 RISERS (7") PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 1 A-401 1 A-402 2 A-404 3 A-404 1 A-404 5 A-908 12A-908 13 A-908 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 3'-6 3/4"15'-8" ROVIF2'-4 3/4"8'-2"R.O.18'-1 1/2"4'-1 3/4"3'-1 1/2"R.O.6"24'-1"23'-9 3/4" 1'-1" 03 03 03 WT11 03 0204 WT17 WT03-B13 13 13 13 RESTRM 108 ACC. RSTRM 109 TRASH RM 119 01 02 03 04 05 06 07 08 09 10 11 12 13 14 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE METAL TRELLIS SCALE: 1/4" = 1'-0"1 1st FLOOR PLAN 0 2'4'8' Page 129 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 68 OF 141 A-113 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln2nd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 101.B104.A105.A 105.B 101.A DN 5 5 2 A-401 2 A-402 5 A-403 2 A-204 1 A-204 1 A-203 3 A-203 2 9'-2 1/4"3'-8 3/4"VIF15'-8"VIF40'-1"5'-2 1/4"7 1/2"12'-11 3/4"4'-5 1/4"6'-3"VIF11'-8 1/2"12'-2 1/2"12'-4"14'-1 1/2"5'-1 1/4"3'-8"CLRF.F. 11.67' = 28.17'82'-6 3/4"2'-10"7 1/2"3 1/2" 94'-2" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2" VIF F.F. 9.17' = 25.67' 10 1/2"3'-2 1/4" R.O. 15'-11 1/2"4'-3 1/4"4'-9"5 1/2"F.F. 11.67' = 28.17' F.F. 11.67' = 28.17' F.F. 11.67' = 28.17' F.F. 9.17' = 25.67' 26'-8 3/4"11'-5"28'-1/2"15'-9"4'-5"WT10-BWT07-B WT07-B WT11 WT10-A WT07-B WT07-BWT07-BWT03-BWT02-A WT06WT12 WT06 WT05 WT11 42" GUARDRAIL WT09-BWT07-BWT10-BWT09-CWT09-C WT07-A WT07-A WT07-B WT02-BW T02-C WT08-BWT04-B WT06WT01WT14-B OPEN TO BELOW 5X5 5X10 5X10 5X10 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X105X105X105X105X10 5X5 5X5 5X5 5X5 5X5 5X5 5X5 5X10 OPEN TO BELOW OPEN TO BELOW OPEN TO ABOVE 5X5 5X5 5X5 5X5 5X5 5X15 5X5 5X5 OPEN TO TRANSFORMER BELOW 5X6 DECOMISISONED AREA 1340 SF OFFICE 207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02 209 LOBBY 203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED 211 #DrgID #LayID DN PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 209.1 1234567UP 12 RISERS (6 1/2")12345678910111213141516UP 16 RISERS (6 25/32") 5 A-908 6 A-903 0905 03 03 WT06 WT17 01 02 03 04 05 06 07 08 09 10 11 12 13 14 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE METAL TRELLIS SCALE: 1/4" = 1'-0"1 2ND FLOOR PLAN 0 2'4'8' Page 130 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 69 OF 141 A-114 3rd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 316.A 316.1 316.B 316.C 320.A 320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B 303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4 A-404 1 A-405 2 A-405 3 A-908 5 A-908 9 A-908 9 A-908 2 A-204 1 A-204 1 A-203 3 A-203 #DrgID #LayID 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" PC 15.24'PC 15.44'13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"11'-5 3/4"9'-3 3/4"6'-2"3'-1/2"R.O.2'-7 1/2"3'-3"R.O.3 3/4"5'-9" 6 1/2" 2'-8 1/2" RO 15'-3 1/4"9'-3"6'-2"7'-1/2"18'-9 3/4"15'-8 1/2"4'-9"4'-1 1/2"2'-1"7'-6 1/4"48'-3 3/4" F.F. = 18.17' = 34.67'45" CLR2'-7 1/4"4'-2" RO 2'-1 1/2" FF =18.25' = 34.75' 28'-1"5'-0" 27'-7"5'-6 1/2" VIF 13'-10 3/4"26'-8 1/2"11'-5"28'-1/2"15'-9"10'-10 1/2"R.O.16'-11 1/4"12'-11"5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4"3'-0"FF = 18.17' = 34.67' 14'-0" RO WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B W T 14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 W T 16WT16WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPENTO BELOW OPEN TO BELOW OPEN TO ABOVE OPEN TO ABOVE ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO 303 OFFICE 301 OFFICE 315 OFFICE 308 OFFICE 310 COURTYARD 318 GARDEN 316 CONFERENCE RM 314 OFFICE 309 OFFICE 304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM 317 GARDEN 311 GARDEN 320 GARDEN 323 VESTIBULE 306 STAIRWELL EXIT 325 RESTROOM CORRIDOR 324 MECH. PLATFORM 302 STAIR 01 327 PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 DN DN #DrgID #LayID 3 A-402 3 A-403 3 A-907 319.1 308.B 309.B PC 15.56' 7'-2 3/4"4'-8 1/2"4'-3 1/2"7'-5"5'-3/4"VIF6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTO ABOVE 465 SQ FT LID PLANTER GREEN ROOF 307 01 02 03 04 05 06 07 08 09 10 11 12 13 14 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE METAL TRELLIS SCALE: 1/4" = 1'-0"1 3RD FLOOR PLAN 0 2'4'8' Page 131 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 70 OF 141 A-115 ROOF PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 01 02 03 04 05 06 07 08 09 10 11 12 13 14 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSED BEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE METAL TRELLIS 5 5 2 A-204 1 A-204 1 A-203 3 A-203 #DrgID #LayID 23'-5 1/4"29'-11 1/2"21'-11 1/2"68'-9"3'-1/4"17'-4 1/4"17'-9 1/4"6 1/4"42'-4 1/4"27'-4 1/2"3'-2 1/4"TO PL81'-11"7 1/2"3 1/2" 94'-2" PC 16.07' PC 16.56' PC 15.24' PC 15.44'3'-7 3/4"43'-6 1/4"21'-2 1/4"21'-9 1/4"4'-3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2" CP F PROPOSED: 45.93' ALLOWED: 53.78'26'-8 3/4"11'-5"28'-1/2"15'-9"LOWEST POINT ON SITE OPEN TO BELOW SLOPE 1/4":12" MIN.SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. 520 SQ FT SOLAR ZONE AREA OPEN TO BELOW OPEN TOBELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 CP A PROPOSED: 45.29' ALLOWED: 45.32' CP B PROPOSED: 45.29' ALLOWED: 45.47' CP C PROPOSED: 45.29' ALLOWED: 46.48'CP D1 PROPOSED: 45.29' ALLOWED: 46.15' CP D2 PROPOSED: 45.29' ALLOWED: 45.93' CP E1 PROPOSED: 48.60'ALLOWED: 53.78' CP E2 PROPOSED: 48.60' ALLOWED: 53.53' 01 01 01 01 06 06 06 01 07 06 06 14 14 14 ELEVATOR OVERRUN ELEVATOR OVERRUN SLOPE 1/4":12" MIN. 10 10 SCALE: 1/4" = 1'-0"1 ROOF PLAN 0 2'4'8' 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.32 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP A:45.32 Prop. Ht. @ CP A:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.32 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP A:45.32 Prop. Ht. @ CP A:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'90.83 Distance from A to Critical Point along Line AB Elev. AB':15.43 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'90.83 Distance from C to Critical Point along Line CD Elev.CD':16.09 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.47 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP B:45.47 Prop. Ht. @ CP B:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 82.42 Distance from Line AB to Critical Point (width) Elev. CP1:16.48 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP C:46.48 Prop. Ht. @ CP C:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'73.13 Distance from A to Critical Point along Line AB Elev. AB':15.39 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'73.13 Distance from C to Critical Point along Line CD Elev.CD':16.18 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 82.42 Distance from Line AB to Critical Point (width) Elev. CP1:16.15 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP D1:46.15 Prop. Ht. @ CP D1:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'90.83 Distance from A to Critical Point along Line AB Elev. AB':15.43 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'90.83 Distance from C to Critical Point along Line CD Elev.CD':16.09 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 65.52 Distance from Line AB to Critical Point (width) Elev. CP1:15.93 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP D2:45.93 Prop. Ht. @ CP D2:45.29 Page 132 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 77 OF 141 A-201 EXISTING ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING107"16.09' 15.54' 05 02 06 03 0404 02 06 02 0303 0404 07 07 07 PL PL 2ND FLOOR+24.50' 1ST FLOOR+16.50' ROOF+34.00' T.O. PARAPET+39.80" 39.26' 36.61' EXISTING GRADE EXISTING SLAB ON GRADE EXISTING STEP INTO PROPERTY 01 02 03 04 05 06 07 08 09 11 10 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS EXISTING STAIRS TO BE REMOVED NOT USED NOT USED NOT USED 0505 0404 EXISTING GRADE EXISTING SLAB PLPL 2ND FLOOR+24.50 1ST FLOOR+16.50 ROOF+34.00' T.O. PARAPET+39.80' 15.46'15.50' SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION - EXISTING 0 2'4'8' SCALE: 1/4" = 1'-0"2 WEST ELEVATION - EXISTING 0 2'4'8' Page 133 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 78 OF 141 A-202 EXISTING ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 03 0303 06 03 04 04 04 04 0404 (E) STEP INTO ENTRY 03 07 PLPL 2ND FLOOR+24.50' 1ST FLOOR+16.50' ROOF+34.00' T.O. PARAPET+39.80' 16.05' 16.09'16.56' 39.26' 36.61'1'-0"15.44' 05 04 02 02 03 0404 07 07 070707 07 PLPL 2ND FLOOR+24.50' 1ST FLOOR+16.50'" ROOF+34.00' T.O. PARAPET+39.80' 16.50' (E) BUILDING SLAB(E) ALLEY (E) DOOR 1' ABOVE GRADE 01 02 03 04 05 06 07 08 09 11 10 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS EXISTING STAIRS TO BE REMOVED NOT USED NOT USED NOT USED SCALE: 1/4" = 1'-0"2 EAST ELEVATION - EXISTING 0 2'4'8' SCALE: 1/4" = 1'-0"1 NORTH ELEVATION - EXISTING 0 2'4'8' Page 134 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 79 OF 141 A-203 PROPOSED ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 1 2 3 4 5 6A-908 8 A-908 10A-908 13A-908 12A-908 9'-1 1/2"9'-1/2"10'-7 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"CP B 45.29'CP D1 45.29'CP D2 45.29'10'-0"19.17' CP E1 48.50'4'-7"10'-2 1/2" RO8'-0"MAX ELEV HT09 04 107.1 MAXIMUM ROOF HEIGHT SLOPE 111.2 110.2 110.1111.1 111.A 110.A CW-A CW-B STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-4 GL-4 CW-C PL PL 7A-908 11A-908 PC15.44' PC16.07' PC46.07' 45.44' CO-4 CO-4 CO-2 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSED BEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE PLPLCABDEF FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'3'-11"4'-7"28'-9 1/2"CP B 45.29'CP A 45.29' CP E2 48.50'CP E1 48.50' 09 STC-1 MT-3 (E) SLAB (N) GRADE MAXIMUM ROOF HEIGHT (E) GRADE CW-K CW-L STC-1 MTL-3MTL-3 MTL-5 GL-1 MTL-5 GL-1 MTL-3MTL-3 312.1 MTL-5 PC15.24'PC15.44' 45.35'45.44'1'-0"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"CP D2 45.29'CP D1 45.29'6 1/4"1'-6"12'-10"VIF105.B105.2 SLOPE PER CIVIL CW-D STC-1 MTL-5 MTL-4 GL-1 GL-4 28'-9 1/2"SCALE: 1/4" = 1'-0"2 SOUTH ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"3 WEST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"1 SOUTHWEST ELEVATION 0 2'4'8' Page 135 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 80 OF 141 A-204 PROPOSED ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 PL PLDFECBA FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29' 1 A-904 2A-904 9A-904 11A-904 7A-904 5A-904 4A-904 3A-904 1'-6"VIF9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"28'-9 1/2"CP D2 45.29'CP C 45.29'CP D1 45.29'12'-11 1/2"VIFCP E2 48.50'CP E1 48.50' CP F 45.93' 04 09 105.1 104.A 101.B105.A MAXIMUM ROOF HEIGHT 104.1 101.1 CW-D CW-F STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-3MTL-3 CW-E PC16.05' PC16.56 5 4 3 2 1 FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'1'-3"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"28'-9 1/2"CP C 45.29' CP A 45.29' 24.13' CP F 45.93' CP E2 48.50'8'-0"MAX ELEV HT8'-10 1/2"R.O. +24.13' 09 04 115.2 MAXIMUM ROOF HEIGHT 119.1 114.1 CW-G CW-H CW-I STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-3 10 CW-JCW-F MTL-5 121.1 118.1115.3 PLPL PC15.24' PC16.56' 45.24' 46.56'7'-8" RO7'-8" RO7'-8" RO7'-8" RO(E) ALLEY (E) BUILDING SLAB HEAD HEIGHT TO MATCH 7'-0" AFF 01 02 03 04 05 06 07 08 09 10 11 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD SCALE: 1/4" = 1'-0"2 EAST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"1 NORTH ELEVATION 0 2'4'8' Page 136 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 82 OF 141 A-301 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnBUILDING SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 01 02 03 04 05 06 07 08 09 10 11 12 TRASH ENCLOSURE OPEN TO BELOW BENCH CONCRETE PLANTER CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP DG GROUT SLOPE NOT TO EXCEED 6.67% CONCRETE PAVER TELEPHONE BACKBOARD OPEN TO BELOW CONCRETE SLAB AT GRADE PLANTER PAD-MOUNTED TRANSFORMER PER SCE (E) BOLLARDS TO BE REPLACED WITH REMOVABLE BOLLARDS 1 A-905 3 A-905 3 A-904 8 A-904 1 A-904 1 A-902 1 A-902 4 A-902 2 A-902 2 A-902 4 A-902 4 A-906 FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' 5A-904 6 A-904 7A-904 4A-904 28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"FT04 FT04 FT04 FT04 RT02 FT02FT02 RT01 RT01 RT01 RT05 SIM SIM SIM SIM SIM OFFICE 301 STAIR 02 114 LOADING ZONE 115 ELEVATOR 02 STORAGE UNITS 113 RETAIL 101 STAIR 02 209 STORAGE UNITS 210 STORAGE UNITS 210 GARDEN 316 OFFICE 315 CONFERENCE RM 314 STAIR EXIT 325STAIR 02 324 TRANSFORMER 121 9 A-904 4 A-906 FT01FT01FT01FT01 RT02 2 A-904 1 A-904 1 A-902 1 A-902 1 A-902 1 A-906 1 A-906 3 A-902 4 A-902 3 A-905 5 A-902 1 A-906 FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' 5A-904 28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"4'-0"FT04 FT07 RT02FT07FT04 FT02 FT01 FT01 FT04 RT01RT01 RT01 LID PLANTER BEYOND LID PLANTER BEYOND FT02 PERGOLA SIM SIM SIM SIM SIM GARDEN 323 COURTYARD 318 RECEPTION 317 GARDEN PATIO 303 RSTRM CORRIDOR324 STAIR 02 209 STORAGE UNITS 210 RETAIL 104 STORAGE UNITS 113 SIM SCALE: 1/4" = 1'-0"1 BUILDING SECTION - E/W 0 2'4'8' SCALE: 1/4" = 1'-0"2 BUILDING SECTION - COURTYARDS E/W 0 2'4'8' Page 137 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 83 OF 141 A-302 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnBUILDING SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING 1 A-902 1 A-902 1 A-905 4 A-902 1 A-906 1 A-906 2 A-906 2 A-907 1 A-902 3 A-902 4 A-908 FOUNDATION -3.13' FOUNDATION -3.13' 1ST FLOOR ±0.00' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' 3RD FLOOR +18.17' GARDEN ROOF +23.17' GARDEN ROOF +23.17' ROOF +28.79' ROOF +28.79'28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"4'-6 1/2"FT06FT03 FT07 FT02 FT01 FT04FT04 RT02 FT01 FT02 FT01 FT02 FT01 FT01 RT01RT01 RT03 SIM SIM COURTYARD 318 OFFICE 308 OFFICE 205 SPACE NOT USEDSTORAGE UNITS 210 LOBBY 107 RESTROOM 109 WINE STORAGE 112 STORAGE UNITS 113 LOADING ZONE 115 CONFERENCE RM 314 SIM SIM SIM SIM 3 A-906 SCALE: 1/4" = 1'-0"1 BUILDING SECTION N/S 0 2'4'8' Page 138 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 84 OF 141 A-303 1 1 2 2 3 3 4 4 5 5 6 6/Users/selinagottloeber/Laney LA Dropbox/Selina Gottloeber/2022/22007 - Powers - 901 HB/03 Design/04 Archicad/02 Current/22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.plnWALL SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 10 12-02-25 PLANNING COM. HEARING2.8960.9141.8541.3461.829HSS COLUMN BEYOND FIRE STOPPING WALL TBD PER T24 ROOF DRAIN 2ND FLOOR - STORAGE +12'-1.5" 3RD FLOOR - OFFICE +19.58' ROOF GARDEN +24.00' 2ND FLOOR - STORAGE +9'-2" 1ST FLOOR +0.00' ROOF +30.00' 3 A-904 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' FT06FT03 FT02 FT01FT01 SCALE: 1/2" = 1'-0"1 WALL SECTION C 0 1'2'4' SCALE: 1/2" = 1'-0"2 WALL SECTION A - COORDINATION 0 1'2'4' Page 139 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 85 OF 141 A-401 STAIR 01 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 4A-401 8A-401 9A-4017'-4"CLR44" CLR6'-7 1/2" CLR 4'-7"RO MIN.OPEN TO ABOVE ELEVATOR 01 STAIR 01 121 RESTRM CORRIDOR 107 1234567 8 UP 20 RISERS (7") 1 A-302 7A-401 6A-401 5 A-401 10A-401 4 4" ACC. RSTRM 109 4A-401 8A-401 9A-40144"44" CLR44" CLR44" CLR ELEVATOR 01 STAIR 01 204 LOBBY 203 DN 7A-401 6A-401 5 A-401 10A-401 1234567UP 12 RISERS (6 1/2") 4A-401 8A-401 9A-401 44" CLROPEN TO BELOW OPEN TO BELOW ELEVATOR 01 GARDEN 311 VESTIBULE 306 STAIR 01 327 7A-401 6 A-401 5A-401 10 A-401 DN 34 5 A-903 16 A-903 8 A-903 34" - 38"42" MINGUARDAIL42" MINGUARDAILFT05 FT01 FT03 SIM E DF 4 A-903 7 A-903 34" - 38"12" FT01 FT06 FT03 SIM E DF 3 A-903 1 A-903 4 A-903 +13.38'FOUNDATION +16.50' 1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17' 2ND FLOOR - OFFICE +34.67' 3RD FLOOR +39.67' GARDEN ROOF +45.29' ROOF 34" - 38"12" 11"42"GUARDRAILFT06 FT03 FT05 FT01FT012 A-90334" - 38"E DPLF 8 A-903 +4.077 FOUNDATION +5.029 1ST FLOOR +7.8112ND FLOOR - STORAGE +8.585 2ND FLOOR - OFFICE +10.566 3RD FLOOR +12.090 GARDEN ROOF +13.805ROOF FT03FT06 FT01 RT05 RT01RT01 FT05 D E F +160 1/2"FOUNDATION +198" 1ST FLOOR +307 1/2" 2ND FLOOR - STORAGE +338" 2ND FLOOR - OFFICE +416" 3RD FLOOR +476" GARDEN ROOF +543 1/2" ROOF FT06FT03 FT05 D E F FT01 FT03 FT06 FT05 FT01 3 4 +160 1/2" FOUNDATION +198" 1ST FLOOR +307 1/2" 2ND FLOOR - STORAGE +338" 2ND FLOOR - OFFICE +416" 3RD FLOOR +476" GARDEN ROOF +543 1/2" ROOF FT05 FT01 SCALE: 1/4" = 1'-0"1 1ST FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"2 2ND FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"7 STAIR 01 SECTION SOUTH 0 2'4'8'SCALE: 1/4" = 1'-0"6 STAIR 01 SECTION WEST 0 2'4'8' SCALE: 1/4" = 1'-0"5 STAIR 01 SECTION WEST 0 2'4'8'SCALE: 1/4" = 1'-0"10 ELEVATOR SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"4 STAIR 01 SECTION EAST SCALE: 1/4" = 1'-0"8 STAIR 01 SECTION EAST SCALE: 1/4" = 1'-0"9 STAIR 01 SECTION NORTH 0 2'4'8' Page 140 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 86 OF 141 A-402 STAIR 02 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10123456789101112131415161718UP18 RISERS (6 23/32") 4 A-402 5A-40245"CLR12" 5X10 5X5 5X5 5X5 5X55X5 STAIR 02 114 PL SB C B A 1 1 A-301 2 A-301 6A-402 13 DN 4A-402 5 A-402 12"45"CLEAR45"CLEARR 45" 5X10 STAIR 02 209 PL SB C B A 1 1 A-301 2 A-301 6 A-402 12345678910111213141516UP 16 RISERS (6 25/32") 4A-402 5 A-402 4 A-403 45" CLR15"-16" OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE STAIR 02 324 GARDEN STAIRWELL EXIT 325 PL SB C B 2 A 1 1 A-301 2 A-301 6 A-402 DN PLA B C 9 A-903 12 A-903 11 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF 7'-1/4"3'-0"PLA B C 12 A-903 11 A-903 9 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF 7'-7"3'-0"SIM SIM SIM 10 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF SCALE: 1/4" = 1'-0"1 1ST FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"2 2ND FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"4 STAIR 02 SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"5 STAIR 02 SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"6 STAIR 02 SECTION 0 2'4'8' Page 141 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 87 OF 141 A-403 STAIR 03 & ELEVATOR 02 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 4 A-403 7'-9 1/2"CLR8'-4"CLR 4'-2" RO MIN. 5X10 5X5 CONTROLLERFIRE (ASR) RM 118 ELEVATOR 02 ELEV RM 121 TRASH RM 119 4 A-403 4'-2" RO MIN.7'-9 1/2"CLR8'-4" CLR 5X105X10 5X5 5X5 5X5 5X5 5X6 ELEVATOR 02 STORAGE UNITS 210 4 A-403 7'-9 1/2"CLR36" DBL DOOR TALL CABINET 30" DBL DOOR BASE CABINET 30"36"36" 170 7/8" OVERALL 24"1 1/2"8'-4" CLR OPEN TO ABOVE ELEVATOR 02 STAIRWELL EXIT 325 MECH. PLATFORM 302 2 +13.38' FOUNDATION +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF SCALE: 1/4" = 1'-0"1 1ST FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"5 2ND FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"4 ELEVATOR 2 SECTION 0 2'4'8' Page 142 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 88 OF 141 A-404 ENLARGED BATHROOM PLANS & ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 CL CL 17"-18" 24" MIN12" MIN 36" MIN 33"-36"17"-19"36" PT-1 SURFACE MOUNTED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR 48"40" MAX29" MIN11" MIN 8" MIN 9"MINTL-1 ACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW PT-1 48" MAX18"RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE PT-1 TL-1 TO LOBBY CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 12" MAX 54" MIN 24" MIN19" MIN1 1/2" MAX7"-9" PT-1 TL-1 109.1108.1 CL CL CL CLCL 1A 1B 1C 1D A-404 1E 1F 1G 1H A-404 18"18"22"22"18"18"106.1CLCL2A 2B 2C 2D A-404 18"18"22" 103.1 CL CL 2B 2A 2D 2C A-404 12"48"12" SIM 320.A 320.1 323.A 316.1320.B 321.1 322.1 3A 3B 3D 3C A-404 3H 3E 3F 3G A-404 2 1/2" MAX 3" MAX1 1/2" MAX15"-16" OPEN TO ABOVE OPEN TO ABOVE 48" MAX28" PT01 TL01 MIRROR CL CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.40" MAX.17"-18"17"-19"RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.33"-36"PT01 TL01 +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.34" MAX.29" MIN.9"MIN.11" MIN. 8" MIN. PT01 TL01 ACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW TO RESTROOM CORRIDOR CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.33"-36"12" MAX. 42"MIN.19"MIN.54"MIN. 7"-9"1 1/2"MAX.24" MIN. PT01 ACCESSIBLE TOILET W/ FLUSH CTRL @ OPEN SIDE OF TOILET TL01 8" MIN 48" MAX18" TL-1 TO LOBBY +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. PT-1 29" MIN11"MIN 9"MINACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW RECESSED PAPERTOWEL DISPENSER AND RECEPTACLE +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. TL-1 PT-1 +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT.33"-36"36"MIN. 24" MIN 12" MIN 17"-18"17"-19"18" MIN 40" MAX48"31" PT01 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR CL CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 11" 1" 54" MIN. PT01 27"MIN. (KNEE)9MIN. (TOE)8"MIN. (KNEE)6"MAX. (TOE) 17"MIN. +0'-0" A.F.F. PT01 CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 17"-18" 24" MIN 12" MIN 36" MIN 33"-36"17"-19"32" PT-1 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR 48"40" MAX+0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT.29"2 1/2" 8 1/2"MAX.2 1/2" PT01 +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. PT01 TL01 TO RETAIL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. 36"48" MAX33" MIN16" MIN 27" MAX PT01 MIRROR 6" MAX SHOWER CONTROL BOUNDARY LOCATION 40" MAX48"15"6'8"-7'-0" TYP.SHOWER HEAD HT.+0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. PT01 TL01 CL CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT.34" MAX24" MIN12" MIN 36" MIN 33"-36"17"-18"29" MIN11" MIN 8" MIN 9"MIN17"-19"48" MAXPT-1 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") ACCESSIBLE SINK &FAUCET W/ INSUL DRAIN PIPE BELOW RECESSED PAPERTOWEL DISPENSER AND RECEPTACLE CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT.24"42" MIN 12" MAX 54" MIN 24" MIN33"-36"19" MIN1 1/2" MAX7"-9" PT-1 WALL BEHIND PT-1 ACCESSIBLE TOILET W/ FLUSH CTRL @ OPEN SIDE OF TOILET TL-1 SCALE: 3/8" = 1'-0"1A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1D RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1 LOBBY RESTROOM SCALE: 3/8" = 1'-0"2 RETAIL RESTROOM 106 SCALE: 3/8" = 1'-0"3 RETAIL RESTROOM 103 SCALE: 3/8" = 1'-0"4 OFFICE RESTROOM 3E OFFICE RESTROOM 3G OFFICE RESTROOM 3H OFFICE RESTROOM3FOFFICE RESTROOM SCALE: 3/8" = 1'-0"1H RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1G RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1E RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1F RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2D RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3D RESTROOM ELEVATION Page 143 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 89 OF 141 A-405 ENLARGED KITCHEN PLANS & ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. 169 3/8"OVERALL 2 1/4" 84"84"5/8"36"69 1/2"105 1/2"CL 76"29 1/2"329 3/4" OVERALL 105 1/2"OVERALL17"10"10"40"29 1/2"36"7 1/2"7 1/2"7 1/2"7 1/2"1/4" 161"7 1/2"161" +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. DW CL F DW F 1A 59"36"24" DRAWER 24" DRAWER 36" SINK 24"24" DRAWER 36"59" 322 1/2" OVERALL 24"1 9/16"F F 319.1 2A 36" DBL DOOR TALL CABINET 30" DBL DOOR BASE CABINET 30"36"36" 170 7/8" OVERALL 24"1 1/2"SCALE: 1/2" = 1'-0"2A BAR ELEVATION SCALE: 1/2" = 1'-0"1A KITCHEN ELEVATION SCALE: 1/2" = 1'-0"1 ENLARGED PLAN - KITCHEN SCALE: 1/2" = 1'-0"2 ENLARGED PLAN - BAR Page 144 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 90 OF 141 A-501 DETAILS - WALL ASSEMBLIES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 WT02WT07 WT13 WT03 WT09 WT11 WT04 WT10 WT01 WT05 WT06 WT08 WT12 WT14 WT15 WT16 WT17 TYP FURR'G WALL @ EXIST PERIMTYP INT WALL TYP SHAFT WALL CONC FURR'G WALL @ EXIST PERIM CONC INT WALL ELEV 01 EXT/INT WALL TYP EXT MTL STUD WALL TYP INT DOUBLE STUD WALL EXT/EXT STUD WALL @ ROOF TYP UNCONDITIONED STUD WALL TYP UNCONDITIONED / INT STUD WALL CONC EXT/INT WALL ELEVATOR 02 WALL CONC LID PLANTER WALL @ 3RD FLOOR EXT STUD WALL @ 3RD FLOOR CLERESTORY CONC FURR'G WALL @ 3RD FLOOR LID PLANTER @ EXIST PERIM CONC EXT WALL TYP EXT BUILD UP TYP EXT BUILD UP TYP EXT BUILD UP TYP EXT BUILD UP SECTION FIRE RATING: STC RATING: 2 HOUR (GA FILE NO. WP 8191) N/A A: 6" STL STUD B: 10" STL STUDC: 12" STL STUD TYPE:SECTION FIRE RATING: STC RATING: N/A N/A A: 2X4 STUD B: 2X6 STUDC: 2X10 STUD TYPE: SECTION FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 6852) N/A A: N/A B: N/A C: N/A TYPE:SECTION FIRE RATING: STC RATING: N/A N/A A: 8" THICK B: 10" THICK C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: 8"B: 10" C: 12" TYPE: SECTION FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 1072) N/A A: N/A B: C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: 6" STL STUDB: 10" STL STUD C: N/A TYPE: (N) 3-PART STUCCO SYSTEM; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-19 MINERAL WOOL INSUL (N) 5/8" GWB (N) FINISH PER SCHED 5/8" GWB; BACKERBOARD AS REQ'D FOR TILE FINISH PER SCHED 5/8" GWB; BACKERBOARD AS REQ'D FOR TILE FINISH PER SCHED MINERAL WOOL INSUL; FOR SOUND ATTENUATION; FILL CAVITY PLYWD SHEATH'G AS REQ'D; PER STRUCT (3) 5/8" GWB FINISH PER SCHED INTERIORINTERIOR SHAFT INTERIORINTERIOR INTERIOREXTERIOR 2X STUD WALL; PER PLAN 2-1/2" LT GA STL STUD ELEV SHAFTEXTERIOR 5/8" GWB TYP X FINISH PER SCHEDULE (N) 3/8" DRAINAGE LAYER (N) WRB INTERIOREXTERIOR (N) METAL SIDING (N) SHEATH'G PER STRUCT (N) 2X STUD WALL (N) MINERAL WOOL INSUL; R-19 (N) 5/8" GWB (N) FINISH PER SCHEDULE FINISH PER SCHED (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) 3/8" STUCCO DRAIN MAT (N) LT GA STL STUD WALL; PER TYPE (N) 3-PART STUCCO FINISH; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-15 MINERAL WOOL INSUL (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) 3/8" STUCCO DRAIN MAT (N) 3/4" CONC FORMWORK; W/O MEMB OR VAPOR BARRIER; TO BE BURRIED IN WALL; REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE (N) FINISH PER SCHED EXTERIOR (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) FINISH PER SCHED INTERIOR SECTION FIRE RATING: STC RATING: N/A N/A A: 1/2" AIR GAP B: 3" AIR GAP C: TYPE: INTERIORINTERIOR (2) 4" LT GA STL STUD WALL MINERAL WOOL INSUL; FOR SOUND ATTENUATION 5/8" GWB FINISH PER SCHEDULE MINERAL WOOL INSUL; FOR SOUND ATTENUATION SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) 3/8" STUCCO DRAINAGE MAT (N) WRB EXTERIOREXTERIOR (N) 3-COAT STUCCO SYSTEM; FINISH COLOR PER SCHEDULE (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGEDBOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) PLYWD SHEATH'G PER STRUCT SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB UNCONDITIONED (N) 5/8 GWB; EXT RATED (N) 2X STUD WALL UNCONDITIONED (N) FINISH PER SCHEDULE (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) WRB (N) 5/8 GWB; EXT RATED (N) FINISH PER SCHEDULE SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB INTERIOR (N) 5/8 GWB; EXT RATED (N) 2X STUD WALL UNCONDITIONED (N) FINISH PER SCHEDULE (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) 5/8 GWB (N) FINISH PER SCHEDULE (N) R-15 MINERAL WOOL INSUL SECTION FIRE RATING: STC RATING: N/A N/A A: 8" THICK B: 10" THICK C: TYPE: (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) FINISH PER SCHED EXTERIOR (N) MTL FINISH PER SCHED (N) WRB (N) 3/8" STUCCO DRAIN MAT AIR GAP 5/8" GWB; EXT RATED TYP X FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 1072) N/A A: N/A B:C: TYPE: ELEV SHAFTINTERIOR 5/8" GWB TYP X FINISH PER SCHEDULE FINISH PER SCHED MINERAL WOOL INSUL; FOR SOUND ATTENUATION 5/8" GWB TYP X 2X FRAM'G PER STRUCT 2X FRAM'G PER STRUCT NOTE:- THIS CONDITION WILL OCCUR AT ALL EXISTING EXPOSED PARAPET WALLS. - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP SECTION FIRE RATING: STC RATING: N/A N/A A: 6" THICKB: 8" THICK C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB INTERIOREXTERIOR PLANTER (N) EXT SHEATH'G PER STRUCT (N) 2X STUD WALL (N) AIR GAP PER TYPE (N) FINISH PER SCHEDULE (N) 5/8" GWB (N) CONC WALL; PER STRUCT (N) 5/8" GWB PLANTER (N) FINISH PER SCHED (N) WRB (N) 1" RIGID INSULATION INTERIOR (N) 1/2" FURR'G CHANNEL (N) MINERAL WOOL INSUL; R19 SECTION FIRE RATING: STC RATING: N/A N/A A: B: C: TYPE: (N) 3-PART STUCCO FINISH; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-15 MINERAL WOOL INSUL (N) CONC WALL; PER STRUCT PLANTER (N) 3/8" STUCCO DRAIN MAT (N) 3/4" CONC FORMWORK; W/O MEMB OR VAPOR BARRIER; TO BE BURRIED IN WALL; REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE (N) WRB EXTERIOR NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP WRB SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: (N) 10" CONC WALL; PER STRUCT EXTERIOREXTERIOR Page 145 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 91 OF 141 A-502 DETAILS - FLOOR / ROOF / CEILING ASSEMBLIES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 FT02 FT03 FT01 FT04 RT01 RT02 RT03 FT06 FT07 FT05 RT04 RT05 CONC O/ MTL DECK @ STORAGE CONC O/ MTL DECK @ 2ND FLR OFFICE TYP SOG INFILL CONC O/ MTL DECK @ 3RD FLR OFFICE TYP ROOF TYP ROOF @ LID PLANTER GREEN ROOF EXT. WALKWAY @ 2ND FLOOR EXT COURTYARD @ 3RD FLOOR CONC O/ MTL DECK @ 3RD FLR LANDING/ ENTRY ROOF @ 3RD FLOOR MECH. DECK ELEVATOR ROOF 1 1/2"PER STRUCTVARIESNTSVARIESPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTVARIESPER STRUCTVARIESPER STRUCTF.F.E. SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: A: N/AB: C: TYPE: N/A N/A A: N/A B: C: TYPE: A: N/A B: C: TYPE: A: N/A B:C: TYPE: SLOPE INSUL TO DRAIN SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED SECONDARY FULLY- ADHERED MEMB ROOF'G 1/2" COVERBOARD 1/2" DRAINAGE MAT PRIMARY; FULLY-ADHERED 60 MIL MEMB ROOF'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT DRAINAGE LAYER; PER GREEN ROOF MFR PEDESTAL SYSTEM; PER MFR EXTENSIVE TRAY GREEN ROOF SYSTEM; INSTALLED BY OTHERS STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION (NOINSUL @ STORAGE CEILING; TYP) 1/2" RESILIENT CHANNEL 5/8" GWB (NO GWB @ STORAGE CEILING; TYP) FINISH PER SCHED MTL DECK'G PER STRUCT FINISH PER SCHED STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT 1-1/2" CONC TOPP'G SLAB REINFORCED CONC SLAB; PER STRUCT; TIE INTO (E) FOUNDATION AS SPEC'D BY STRUCT 1-1/2" TOPP'G SLAB; TO FLUSH OUT W/ (E) SLAB AS REQ'D FINISH PER SCHED 10 MIL VAPOR RETARDER; 12" MIN OVERLAP @ SEAMS; TAPED 2" MIN RIGID INSUL (R10); AS REQ'D 6" FREE-DRAINING CLEAN GRAVEL (1/4" MIN - 2" MAX DIA AGGREGATE) COMPACT SUBGRADE; STRUCT FILL WHERE REQ'D STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB (NO GWB @ STORAGE CEILING; TYP) FINISH PER SCHED MTL DECK'G PER STRUCT 1-1/2" CONC TOPP'G SLAB 1/4" ACOUSTIC UNDERLAYMENT FINISH FLOOR AS SCHEDULED SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL FINISH PER SCHED PEDESTAL SYSTEM; PER MFR PAVER O/ PEDESTAL SYSTEM PER SCHED; INSTALLED PER MFR 1/2" RESILIENT CHANNEL 5/8" GWB 1" RIGID INSUL WICKING GEO-TEXTILE; PER MFR PERMAVOID STRUCTURAL CELLS PLANTING MEDIUM PER LANDSCAPE PLANS WICKING GEO-TEXTILE; PER MFR SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL FINISH PER SCHED PEDESTAL SYSTEM; PER MFR PAVER O/ PEDESTAL SYSTEM PER SCHED 1/2" RESILIENT CHANNEL 5/8" GWB EXTERIOR INTERIOR EXTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR SECTION FIRE RATING: STC RATING: A: N/A B: C: TYPE: N/A N/A STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB; EXT RATED AS REQ'D FINISH PER SCHED MTL DECK'G PER STRUCT RIGID INSUL; FILL AS REQ'D TO FLUSH OUT TOPP'G SLAB 1-1/2" CONC TOPP'G SLAB; FLUSH OUT W/INT OFFICE FLR EXTERIOR INTERIOR STRUCT CONC O/ MTL DECK; PER STRUCT MTL DECK'G PER STRUCT SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT SECTION FIRE RATING:N/A N/A A: N/AB: C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G HOIST BEAM, PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL 2X STL STUDS SECTION FIRE RATING:N/A N/A A: N/A B: C: TYPE: STRUCT CONC O/ MTL DECK; PER STRUCT MTL DECK'G PER STRUCT MTL DECK'G PER STRUCT AIR/VAPOR BARRIER STRUCT CONC O/ MTL DECK; PER STRUCT Page 146 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 92 OF 141 A-601 FINISH SCHEDULE & MATERIAL LEGEND ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 303 304 305 306 307 308 309 310 311 312 314 315 316 317 318 319 320 321 322 323 324 324 325 327 GARDEN PATIO OFFICE OFFICE VESTIBULE GREEN ROOF OFFICE OFFICE OFFICE GARDEN MECHANICAL PLATFORM CONFERENCE RM OFFICE GARDEN OUTDOOR ROOM COURTYARD KITCHEN GARDEN RSTRM RSTRM GARDEN RESTROOM CORRIDOR STAIR 02 STAIRWELL EXIT STAIR 01 GL-2 GL-2 PL-1 / GL-2 GL-2 GL-2 GL-2 PL-1 / GL-2 PT-1 STC-1 PL-1 / GL-1 PL-1 / GL-1 GL-1 GL-2 MT-1 / GL-2 WD-3 MT-3 PL-1 TL-1 / GL-2 MT-3 PL-1 PT-1 PT-1 N/A PL-1 / GL-1 PL-1 / GL-1 PL-1 / GL-1 MT-1 / GL-3 PL-1 / GL-2 PL-1 PL-1 PT-1 STC-1 PL-1 PL-1 / GL-2 PL-1 / GL-2 GL-2 MT-1 / GL-2 GL-2 MT-3 PL-1 PL-1 MT-3 PL-1 PT-1 PT-1 MT-1 GL-2 PL-1 PL-1 / GL-1 MT-1 PL-1 PL-1 PL-1 PT-1 STC-1 GL-2 GL-2 PL-1 / GL-2 GL-2 MT-1 / GL-2 WD-3 PL-1 / GL-2 PL-1 PL-1 PL-1 / GL-2 PL-1 PT-1 PT-1 N/A GL-2 GL-2 PL-2 MT-1 / GL-3 PL-1 PL-1 PL-1 / GL-1 PT-1 N/A PL-1 / WD-3 PL-1 PL-1 / GL-2 GL-2 MT-1 / GL-2 PL-1 / WD-3 PL-1 / GL-2 PL-1 PL-1 MT-3 PL-1 PT-1 PT-1 MT-1 / GL-3 N/A N/A TM-2 TM-1 N/A TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 N/A N/A TM-2 TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A N/A N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 TM-1 N/A TM-2 TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A N/A N/A N/A TM-2 N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 N/A N/A N/A TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 TM-1 / GL-3 WD-1 WD-1 WD-1 CO-2 WD-1 WD-1 WD-1 WD-1 N/A WD-1 WD-1 N/A WD-1 WD-1 TL-1 TL-1 WD-1 CO-1 CO-1 CO-2 OTS PL-1 PL-1 MT-1 OTS PL-1 PL-1 PL-1 PT-1 PT-1 PL-1 PL-1 OTS PL-1 OTS PL-1 OTS PL-1 PL-1 OTS PL-1 PT-1 PT-1 MT-1 ST-1 ST-1 SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS, SEE ELEVATIONS SEE INTERIOR ELEVATION SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS SEE INTERIOR ELEVATION SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS FINISH SCHEDULE ROOM NUMBER 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 118 119 120 121 121 121 203 204 205 206 207 208 209 210 211 301 302 303 NAME ELEVATOR 01 ELEVATOR 02 RETAIL HALL RSTRM RETAIL RETAIL RSTRM RESTRM CORRIDOR RESTRM ACC. RSTRM OFFICE OFFICE WINE STORAGE STORAGE STAIR 02 LOADING ZONE FIRE (ASR) RM TRASH RM ELECTRIC RM ELEV RM STAIR 01 TRANSFORMER LOBBY STAIR 01 OFFICE OFFICE OFFICE HALLWAY STAIR 02 STORAGE UNITS SPACE NOT USED OFFICE MECH. PLATFORM GARDEN PATIO WALL NORTH PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 N/A PT-1 PT-1 PT-1 PL-1 / GL-1 PT-1 GL-2 EAST PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 STC-1 PT-1 PT-1 PT-1 PL-1 / GL-1 PT-1 PL-1 / GL-1 SOUTH PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 STC-1 MT-1 PL-1 PL-1 PL-1 STC-1 PT-1 PT-1 PT-1 GL-2 PT-1 GL-2 WEST PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 N/A PT-1 PT-1 PT-1 GL-2 PT-1 GL-2 BASE NORTH TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 TM-2 TM-5 N/A EAST TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 TM-2 TM-5 N/A SOUTH TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 N/A TM-5 N/A WEST TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 N/A TM-5 N/A FLOOR CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-2 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-2 CO-2 CO-2 CO-1 CO-1 CO-1 CO-3 CO-1 CO-1 CO-1 WD-1 CO-1 WD-1 CEILING PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 OTS PT-1 OTS OTS OTS OTS OTS MT-1 MT-1 MT-1 PL-1 PL-1 OTS PT-1 OTS PTS PL-1 PT-1 OTS COUNTERTOP & BACKSPLASH REMARKS BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN SEE STORAGE UNIT SPECS FOR WALL FINISH SEE STORAGE UNIT SPECS FOR WALL FINISH SEE LANDSCAPE PLANS FINISH SCHEDULE ROOM NUMBER NAME WALL NORTH EAST SOUTH WEST BASE NORTH EAST SOUTH WEST FLOOR CEILING COUNTERTOP & BACKSPLASH REMARKS FINISH LEGEND TAG DESCRIPTION VENDOR/MANUFACTURER MODEL FINISH/COLOR SIZE LOCATION NOTES CO-1 CONCRETE FLOOR TBD TBD TBD TBD 101 - 106, 108 - 120, 201, 202, 205 - 207, 209 - 211 TOPPING SLAB CO-2 CONCRETE FLOOR - BUSH HAMMERED 107, 121, 319 TOPPING SLAB BUSH HAMMERED CO-3 CONCRETE PEDESTAL SYSTEM 208 PAVERS TO MATCH CO-2 CO-4 TEXTURED CONCRETE EXTERIOR PLANTERS GL-1 GLASS CURTAIN WALL ARCADIA TBD TBD TBD SEE ELEVATIONS GL-2 GLASS PARTITION WALL ARCADIA TBD TBD TBD SEE PLANS GL-3 GLASS RAILING ARCADIA TBD TBD TBD 306 GL-4 GLASS STOREFRONT ARCADIA TBD TBD TBD SEE ELEVATIONS MT-1 METAL PANELING - DECORATIVE TBD TBD TBD TBD 107, 121, 203, 204, 306, 327 MT-2 METAL PANELING - PROTECTION TBD TBD TBD TBD 119 TRASH ROOM MT-3 METAL PANELING - EXTERIOR 312, 320, 323 EXTERIOR GRADE MT-4 ALUMINUM STOREFRONT LIGHT CHAMPAGNE 101, 104, 105 STOREFRONT / 110, 111 IN 1ST FLOOR OFFICE MT-5 ALUMINUM CURTAIN WALL MEDIUM BRONZE 2ND FLOOR AND 3RD FLOOR OTS OPEN TO STRUCTURE PL-1 PLASTER - LEVEL 5 FINISH TBD TBD TBD TBD 110, 111, 205, 206, 207 PT-1 PAINT 101 - 106, 108, 109, 112, 114, 116 - 118, 120, 201, 202, 209, 211, 311, 324 - 326 ST-1 GRANITE COUNTER TOP TBD TBD TBD TBD 314, 319 STC-1 3 PART STUCCO - EXTERIOR COAT TBD TBD TBD TBD SEE ELEVATIONS TL-1 TILE TBD TBD TBD TBD 321, 322 WD-1 WOOD FLOOR TBD TBD TBD TBD 301, 302, 304, 305, 308 - 311, 314, 315, 317, 324 WD-2 WOOD WALL TBD TBD TBD TBD WD-3 WOOD MILLWORK TBD TBD TBD TBD 314, 319 TM-1 BASE TRIM - METAL TBD TBD TBD TBD 107, 119, 121, 203, 204, 306, 327 TM-2 BASE TRIM - 3/8" REVEAL TBD TBD TBD TBD 110, 111, 205, 206, 207, 301, 304, 305, 308, 309, 310, 314, 315, 317, 324 TM-3 BASE TRIM - TILE 6"TBD TBD TBD TBD 108, 109, 321, 322 TM-4 BASE TRIM - WOOD TBD TBD TBD TBD 101, 102, 104, 105, 112, TM-5 BASE TRIM - RUBBER TBD TBD TBD TBD 103, 106, 112 - 118, 120, 201, 202, 209, 210, 211, 311, 324, 325, 326 SCALE: 1' = 1'-0"2 FINISH SCHEDULE CONTINUED SCALE: 1' = 1'-0"1 FINISH SCHEDULE SCALE: 1' = 1'-0"3 FINISH LEGEND Page 147 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 93 OF 141 A-602 DOOR + WINDOW SCHEDULES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 INTERIOR DOOR SCHEDULE ID 102.1 102.2 103.1 105.3 106.1 108.1 109.1 112.1 209.1 301.1 304.1 305.1 308.1 309.1 310.1 314.1 314.2 321.1 322.1 325.1 325.2 ROOM NAME RETAIL RETAIL HALL RESTRM CORRIDOR RSTRM RESTRM CORRIDOR ACC. RSTRM WINE STORAGE STAIR 02 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONFERENCE RM OFFICE RSTRM RESTROOM CORRIDOR STAIRWELL EXIT STAIRWELL EXIT TYPE D D D D D D D D M B B B B B B B B C C C I OPERATION INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING INT. SWING NET FRAME WIDTH 3'-1/2" 3'-1/2" 3'-1/2" 3'-2 1/2" 3'-1/2" 2'-10 1/2" 3'-1/2" 3'-2 1/2" 3'-4" 3'-2" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-3 1/4" 2'-8" 2'-9 1/2" 3'-2" 3'-0" NET FRAME HEIGHT 8'-1 1/4" 8'-1 1/4" 6'-9 1/4" 7'-1 1/4" 8'-1 1/4" 6'-9 1/4" 6'-9 1/4" 7'-1 1/4" 6'-10" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 6'-10" MATL HM HM HM HM HM HM HM HM HM ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS SC WOOD SC WOOD HM HM FRAME MATL HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM WD WD HM HM DETAIL HEAD 4/908 4/908 4/908 4/908 4/908 4/908 4/908 4/908 4/908 JAMB 5/908 5/908 5/908 5/908 5/908 5/908 5/908 5/908 5/908 HDWR. SET 2 2 3 3 3 3 3 3 6 2 2 2 2 2 2 2 2 3 3 2 3 ACCESORIES RATINGS FIRE Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated 1.5 hours Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated 45 minutes Unrated STC Manufacturer ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA REMARKS EXTERIOR DOOR SCHEDULE ID 101.1 104.1 105.1 105.2 107.1 110.1 110.2 111.1 111.2 114.1 115.1 115.2 115.3 119.1 120.1 121.1 303.1 306.1 312.1 316.1 316.1 317.1 319.1 320.1 ROOM NAME RETAIL RETAIL RETAIL RETAIL RESTRM CORRIDOR OFFICE OFFICE OFFICE OFFICE STAIR 02 LOADING ZONE LOADING ZONE LOADING ZONE LOADING ZONE STORAGE GARDEN PATIO VESTIBULE GARDEN GARDEN OUTDOOR ROOM COURTYARD GARDEN TYPE H H H H K L H L H E E F E F F E B A C B B J J B OPERATION EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. PIVOT EXT. SWING EXT. BI-FOLD EXT. SWING EXT. BI-FOLD EXT. SWING EXT. SWING EXT. ROLL-UP EXT. SWING EXT. ROLL-UP EXT. ROLL-UP EXT. SWING SWING PIVOT SWING SWING SWING EXT. SLIDING EXT. SLIDING SWING NET FRAME WIDTH 5'-9 1/2" 5'-9 1/2" 5'-9 1/2" 5'-9 1/2" 9'-1 1/2" 3'-6" 7' 3'-6" 6'-11 1/2" 3'-4" 3' 10'-4" 3' 8'-2" 14'-2 1/4" 3' 3' 6'-1 1/2" 3' 2' 2' 14' 26'-5" 2'-1/8" NET FRAME HEIGHT 9'-10" 9'-10" 9'-10" 9'-10" 10' 10' 7'-4" 10' 7'-4" 6'-10" 7' 7'-8 1/4" 7' 7'-8" 7' 7' 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 6'-9 1/4" 6'-9 1/4" 8'-10" 8'-10" 6'-9 1/4" MATL ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS SC WOOD ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS HM HM HM HM HM HM HM ALUM / GLASS ALUM / GLASS HM ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS FRAME MATL HM HM HM HM WD HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM DETAIL HEAD 8/904 8/904 8/904 8/904 10/908 6/908 6/908 6/908 6/908 4/908 4/908 4/908 4/908 --- 4/908 1/902 1/908 4/908 1/902 1/902 1/908 1/908 1/902 JAMB 11/904 11/904 11/904 11/904 12/908 7/908 8/908 8/908 8/908 5/908 5/908 5/908 5/908 --- 5/908 3/908 3/908 5/908 3/908 3/908 9/908 9/908 3/908 HDWR. SET 1 1 1 1 1 1 3 1 3 6 6 5 6 5 5 6 2 1 3 2 2 2 2 3 ACCESORIES RATINGS FIRE Unrated Unrated Unrated Unrated 1 hour 1 hour 1 hour 1 hour 1 hour 1.5 hours 45 minutes 1 hour 20 minutes 1 hour 1 hour 20 minutes Unrated Unrated 30 minutes Unrated Unrated Unrated Unrated Unrated STC --- Manufacturer ARCADIA ARCADIA ARCADIA ARCADIA CUSTOM ARCADIA ARCADIA ARCADIA ARCADIA JANUS JANUS JANUS ARCADIA ARCADIA ARCADIA ARCADIA REMARKS 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 8" LEAF / STEEL W/ CLADDING (PLASTER) 10" BOTTOM RAIL W/ ADA THRESHOLD 10" BOTTOM RAIL W/ ADA THRESHOLD GARAGE DOOR GARAGE DOOR GARAGE DOOR 1 FIXED, 2 SLIDING PER SIDE 1 FIXED, 2 SLIDING PER SIDE GARDEN DOOR TO SWING INTO HALLWAY TYPE A TYPE B TYPE C TYPE D TYPE E TYPE F VIEW OPERATION PIVOT SWING SWING INT. SWING EXT. SWING EXT. ROLL-UP DOOR TYPE G TYPE H TYPE I TYPE J TYPE K TYPE L TYPE M EXT. SWING EXT. DOUBLE SWING INT. SWING EXT. SLIDING EXT. PIVOT EXT. SWING INT. SWING DOOR 1 HARDWARE SCHEDULE HARDWARE GROUP FUNCTION MANUFACTURER MODEL FINISH NOTES 2 3 4 5 ENTRY PASSAGE PRIVACY COVER PANEL GARAGE TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TYPE A B C D VIEW OPERATION FIX FIX FIX FIX WINDOW LEGEND WINDOW SCHEDULE STORY 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF LOCATION OFFICE OFFICE RETAIL RETAIL RETAIL RETAIL RETAIL OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE TYPE C C A D D D D B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B ID 110.A 111.A 101.A 101.B 104.A 105.A 105.B 301.A 303.A 303.B 303.B 303.B 303.C 304.A 305.A 306.A 308.A 309.A 309.B 310.A 314.A 315.A 317.A 317.B 317.C 318.A 318.B 308.B 310.B 311.A 311.B 311.C 316.A 316.B 316.C 320.A 320.B 323.A UNIT SIZE 7'-0"×2'-8" 6'-11 3/4"×2'-8" 15'-8"×13'-3" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 5'-4 3/4"×8'-9 1/2" 14'-11 3/4"×9'-0" 6'-9 1/2"×8'-9 1/2" 6'-9 1/2"×8'-9 1/2" 10'-8"×8'-9 1/2" 14'-11 3/4"×8'-9 1/2" 12'-0"×8'-9 1/2" 3'-3 1/2"×8'-9 1/2" 4'-3 1/2"×8'-9 1/4" 7'-8 1/4"×8'-9 1/4" 9'-1/2"×8'-9 1/2" 12'-3 1/2"×3'-9 1/4" 1'-4 1/4"×8'-9 1/2" 12'-7 3/4"×8'-9 1/2" 10'-9 1/2"×8'-9 1/2" 5'-5 1/4"×8'-9 1/2" 11'-11 1/2"×8'-9 1/2" 5'-5 1/4"×8'-9 1/2" 15'-8"×8'-9 1/2" 15'-8"×8'-9 1/4" 10'-9 3/4"×3'-9 1/4" 12'-2"×3'-9 1/4" 5'-3"×6'-9 1/4" 16'-4 1/2"×6'-9 1/2" 16'-3 3/4"×6'-9 1/2" 9'-1 1/4"×6'-9 1/4" 7'-1/4"×6'-9 1/4" 11'-4 1/2"×6'-9 1/4" 3'-0"×6'-9 1/4" 7'-1"×6'-9 1/4" 4'-9 1/2"×6'-10" Nominal Surface Area 18.67 18.63 207.64 319.55 319.55 319.55 319.55 47.43 134.82 59.71 59.71 93.78 131.70 105.41 28.96 37.69 67.35 79.51 46.32 11.95 111.23 94.88 47.77 105.13 47.77 137.73 137.40 40.75 45.84 35.60 111.20 110.85 61.64 47.52 77.08 20.29 48.00 32.70 MODEL <Undefined> N/A N/A N/A N/A N/A <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> UNDEFINED <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> MANUFACTURER ARCADIA ARCADIA CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA <Undefined> ARCADIA ARCADIA <Undefined> <Undefined> <Undefined> <Undefined> ARCADIA ARCADIA FRAME MAT. HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM FRAME FINISH OPERATION FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX HW SET REMARKS SCALE: 1' = 1'-0"2 DOOR SCHEDULE SCALE: 1' = 1'-0"1 HARDWARE SCHEDULE SCALE: 1' = 1'-0"3 WINDOW SCHEDULE TRASH ROOM RESTROOM CORRIDOR Page 148 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt_Hearing 2.pln DRAWN BY: COPYRIGHT: SHEET 94 OF 141 A-603 CURTAIN WALL SCHEDULE ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 12-02-25 PLANNING COM. HEARING10 CURTAIN WALL SCHEDULE Element ID CW-A CW-B CW-D CW-E CW-F CW-G CW-H CW-I CW-J CW-K CW-L Number of Panels 26 6 14 8 10 2 3 5 9 5 6 MODEL <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> MFG ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA MATERIAL ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS FINISH POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE SURFACE AREA 581.59 132.45 386.49 221.57 284.70 58.54 89.71 125.76 226.99 147.24 176.10 REMARKS D E 34.67' 45.29'2'-0"8'-7 1/2"5'-6"2"8'-5 1/2"14'-1" ZONE L 36.67' 31.17' CW-K CW-L 2 3 4 45.29'8'-7 1/2"8'-6"2"8'-5 1/2"37'-7" ZONE A 16'-8" ZONE B 3'-0" ZONE C 17'-1 1/2"CW-A CW-B 207.1 206.1 205.1 34.67' 45.29'2'-0"8'-7 1/2"24'-2" ZONE D.1 36.67' CW-D.1 C B 34.67' 45.29'10'-7 1/2"19'-1" ZONE D.2 27'-11" ZONE E 20'-6 1/2" ZONE F.1 36.67'2'-0"8'-7 1/2"CW-D CW-FCW-E 3 24 34.67' 45.29'2'-0"7'-5" ZONE G 11'-4" ZONE H 16'-0" ZONE I 23'-7" ZONE J.1 16'-2" ZONE F.2 36.67' CW-F CW-G CW-H CW-I CW-J B C 34.67' 45.29'2'-0"6'-10" ZONE J.2 36.67' 316.A 316.1 316.B 316.C 320.A 320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A305.1323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 F DW F 4A-404 1A-405 3A-908 9A-908 9A-908 1A-203 4'-2"11'-5 3/4"9'-3 3/4"6'-2"3'-1/2"R.O.2'-7 1/2"3'-3"R.O.3 3/4"5'-9" 6 1/2" 2'-8 1/2"RO 15'-3 1/4"9'-3"6'-2"7'-1/2"18'-9 3/4"15'-8 1/2"4'-9"4'-1 1/2"2'-1"7'-6 1/4"48'-3 3/4" F.F. = 18.17'= 34.67'45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" FF =18.25' = 34.75' 28'-1"5'-0"10'-10 1/2"R.O.16'-11 1/4"12'-11"5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4"3'-0"FF = 18.17'= 34.67' 14'-0"RO WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 W T16WT16WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO 303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN 316 CONFERENCE RM 314 OFFICE309 OFFICE304 RSTRM 321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN 311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN 3A-907 319.1 308.B 309.B 7'-2 3/4"4'-8 1/2"4'-3 1/2"7'-5"5'-3/4"VIF6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"09 09 09 09 09 0505 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF 307 SCALE: 1' = 1'-0"8 CURTAIN WALL SCHEDULE SCALE: 1/4" = 1'-0"2 CURTAIN WALL ELEVATION - ZONE K & L 0 2'4'8' SCALE: 1/4" = 1'-0"5 CURTAIN WALL ELEVATION - ZONE A, B & C 0 2'4'8' SCALE: 1/4" = 1'-0"4 CURTAIN WALL ELEVATION - ZONE D.1 0 2'4'8' SCALE: 1/4" = 1'-0"6 CURTAIN WALL ELEVATION - ZONE D.2, E, & F.1 0 2'4'8' SCALE: 1/4" = 1'-0"7 CURTAIN WALL ELEVATION - ZONE F.2, G, H, I, & J.1 0 2'4'8' SCALE: 1/4" = 1'-0"1 CURTAIN WALL ELEVATION - ZONE J.2 0 2'4'8' SCALE: 3/32" = 1'-0"3 CURTAIN WALL KEY Page 149 of 324 901 HERMOSA | Roof Gardens 12/3/25 316.A 316.1 316.B 316.C 320.A320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1 323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4A-404 1A-405 2A-405 3A-908 5A-908 9A-908 9A-908 2A-204 1A-204 1A-203 3A-203 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" 13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2" 2'-7 1/2" 3'-3"R.O.3 3/4"5'-9"6 1/2"2'-8 1/2"RO 15'-3 1/4" 9'-3"6'-2" 7'-1/2" 18'-9 3/4" 15'-8 1/2" 4'-9" 2'-1" 7'-6 1/4" 4'-1 1/2" 48'-3 3/4"45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" 28'-1"5'-0" 13'-10 3/4"27'-7"5'-6 1/2"VIF 26'-8 1/2" 11'-5" 28'-1/2" 15'-9" 10'-10 1/2" R.O. 16'-11 1/4" 12'-11" 5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4" 3'-0" 14'-0"RO PC 15.24'PC 15.44' F.F. = 18.17'= 34.67' FF =18.25' = 34.75' FF = 18.17'= 34.67' #DrgID#LayID WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 WT16WT16 WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO303 OFFICE301 OFFICE315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM314 OFFICE309 OFFICE304 RSTRM321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN311 GARDEN320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM302 STAIR 01327 PLPL PL PL SBSB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2A-203 1A-302 1A-301 1A-301 2A-303 2A-301 2A-301 DN DN #DrgID#LayID 3A-402 3A-403 3A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIFPC 15.56' 319.1 308.B 309.B 09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF307 NOT TO SCALE13RD FLOOR PLAN Page 150 of 324 901 HERMOSA | Roof Gardens 12/3/25 316.A 316.1 316.B 316.C 320.A320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1 323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4A-404 1A-405 2A-405 3A-908 5A-908 9A-908 9A-908 2A-204 1A-204 1A-203 3A-203 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" 13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2" 2'-7 1/2" 3'-3"R.O.3 3/4"5'-9"6 1/2"2'-8 1/2"RO 15'-3 1/4" 9'-3"6'-2" 7'-1/2" 18'-9 3/4" 15'-8 1/2" 4'-9" 2'-1" 7'-6 1/4" 4'-1 1/2" 48'-3 3/4"45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" 28'-1"5'-0" 13'-10 3/4"27'-7"5'-6 1/2"VIF 26'-8 1/2" 11'-5" 28'-1/2" 15'-9" 10'-10 1/2" R.O. 16'-11 1/4" 12'-11" 5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4" 3'-0" 14'-0"RO PC 15.24'PC 15.44' F.F. = 18.17'= 34.67' FF =18.25' = 34.75' FF = 18.17'= 34.67' #DrgID#LayID WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 WT16WT16 WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO303 OFFICE301 OFFICE315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM314 OFFICE309 OFFICE304 RSTRM321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN311 GARDEN320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM302 STAIR 01327 PLPL PL PL SBSB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2A-203 1A-302 1A-301 1A-301 2A-303 2A-301 2A-301 DN DN #DrgID#LayID 3A-402 3A-403 3A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIFPC 15.56' 319.1 308.B 309.B 09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF307 NOT TO SCALE13RD FLOOR PLAN Page 151 of 324 901 HERMOSA | Roof Gardens 12/3/25 316.A 316.1 316.B 316.C 320.A320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1 323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4A-404 1A-405 2A-405 3A-908 5A-908 9A-908 9A-908 2A-204 1A-204 1A-203 3A-203 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" 13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2" 2'-7 1/2" 3'-3"R.O.3 3/4"5'-9"6 1/2"2'-8 1/2"RO 15'-3 1/4" 9'-3"6'-2" 7'-1/2" 18'-9 3/4" 15'-8 1/2" 4'-9" 2'-1" 7'-6 1/4" 4'-1 1/2" 48'-3 3/4"45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" 28'-1"5'-0" 13'-10 3/4"27'-7"5'-6 1/2"VIF 26'-8 1/2" 11'-5" 28'-1/2" 15'-9" 10'-10 1/2" R.O. 16'-11 1/4" 12'-11" 5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4" 3'-0" 14'-0"RO PC 15.24'PC 15.44' F.F. = 18.17'= 34.67' FF =18.25' = 34.75' FF = 18.17'= 34.67' #DrgID#LayID WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 WT16WT16 WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO303 OFFICE301 OFFICE315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM314 OFFICE309 OFFICE304 RSTRM321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN311 GARDEN320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM302 STAIR 01327 PLPL PL PL SBSB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2A-203 1A-302 1A-301 1A-301 2A-303 2A-301 2A-301 DN DN #DrgID#LayID 3A-402 3A-403 3A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIFPC 15.56' 319.1 308.B 309.B 09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF307 NOT TO SCALE13RD FLOOR PLAN Page 152 of 324 901 HERMOSA | Offices + Green Roof 12/3/25 316.A 316.1 316.B 316.C 320.A320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1 323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.B 303.B303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4A-404 1A-405 2A-405 3A-908 5A-908 9A-908 9A-908 2A-204 1A-204 1A-203 3A-203 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" 13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2" 2'-7 1/2" 3'-3"R.O.3 3/4"5'-9"6 1/2"2'-8 1/2"RO 15'-3 1/4" 9'-3"6'-2" 7'-1/2" 18'-9 3/4" 15'-8 1/2" 4'-9" 2'-1" 7'-6 1/4" 4'-1 1/2" 48'-3 3/4"45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" 28'-1"5'-0" 13'-10 3/4"27'-7"5'-6 1/2"VIF 26'-8 1/2" 11'-5" 28'-1/2" 15'-9" 10'-10 1/2" R.O. 16'-11 1/4" 12'-11" 5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4" 3'-0" 14'-0"RO PC 15.24'PC 15.44' F.F. = 18.17'= 34.67' FF =18.25' = 34.75' FF = 18.17'= 34.67' #DrgID#LayID WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 WT16WT16 WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO303 OFFICE301 OFFICE315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM314 OFFICE309 OFFICE304 RSTRM321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN311 GARDEN320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM302 STAIR 01327 PLPL PL PL SBSB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2A-203 1A-302 1A-301 1A-301 2A-303 2A-301 2A-301 DN DN #DrgID#LayID 3A-402 3A-403 3A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIFPC 15.56' 319.1 308.B 309.B 09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF307 NOT TO SCALE13RD FLOOR PLAN Page 153 of 324 901 HERMOSA | Aerial View 12/3/25Page 154 of 324 Pa g e 1 of 1 31 9 M a in Stre e t E l Se gu n do , C a lif o rn ia 90 24 5 (21 3 ) 2 39 9 70 0 in f o @ la b ib fu n k .c o m | w w w .la b ib fu nk .c o m MEMO Date: December 03, 2025 To: City of Hermosa Beach Associate Planner Community Development Department | Planning Division, City of Hermosa Beach From: John Labib, SE, Principal Re: PDP23-04 (Precise Development Plan) 901 Hermosa Ave., Hermosa Beach, CA 90254 Structural Memo LFA Job No. 22079 To whom it may concern, This memo is intended to confirm that the diaphragm in the area highlighted in red below is structurally critical for seismic transfer of lateral forces to the lateral force resisting system. cc: Peter Behnam, LFA Page 155 of 324 City of Hermosa Beach | Page 1 of 9 Meeting Date: October 21, 2025 Staff Report No. 25-CDD-140 Honorable Chairperson and Members of the Hermosa Beach Planning Commission ADOPT A RESOLUTION TO APPROVE A PRECISE DEVELOPMENT PLAN AND LOT LINE ADJUSTMENT TO REMODEL AND ADD A THIRD STORY TO AN EXISTING BUILDING AT 901 HERMOSA AVE IN THE GENERAL COMMERCIAL ZONE CEQA: Determine the project is exempt from the California Environmental Quality Act. (Contract Planner Kaneca Pompey) Recommended Action: Staff recommends the Planning Commission: 1. Determine the project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to section 15301, class 1 and section 15305, class 5 of the CEQA guidelines. 2. Adopt a Resolution approving Precise Development Plan (PDP23-04) and Lot Line Adjustment (LLA 23-03) to remodel and add to an existing two-story commercial building that measures 14,021 square feet located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot, subject to conditions of approval (Attachment 1); and Executive Summary: This is a request for approval of a Precise Development Plan (PDP) and Lot Line Adjustment (LLA) to remodel and add to an existing two-story commercial building that measures 14,021 square feet. The project adds a third story with a height of 28 feet, 9.6 inches and reconfigures the existing building layout, resulting in a decrease of 194 square feet of usable floor area for a remodeled multi-tenant commercial building located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot. Staff recommend that the Planning Commission approve the project subject to conditions of approval and determine that the project is categorically exempt from the California Environmental Quality Act. Background: The project site is an existing 8,177-square-foot corner lot located in the southwestern portion of the City, between Ninth Street and Tenth Court and is adjacent to a walk-street. The site has a General Plan land use designation of Community Commercial (CC) and is zoned Downtown Commercial (C-3) (Attachment 2). The site is currently developed with Page 156 of 324 City of Hermosa Beach | Page 2 of 9 a 14,021-square-foot two-story multi-tenant commercial building across three parcels. The current development has no surface parking. The site was developed in 1928. Site Information Table: The following table describes the existing site characteristics Site Information General Plan Community Commercial (CC) Zoning Downtown Commercial (C-3), Coastal Zone Lot Size 8,177 square feet Surrounding Zoning North: C-2 East: C-2 South: C-2 and R-2 (Two-Family Residential) West: R-2 Surrounding Uses North: Residential East: Restaurant South: Restaurant and Residential West: Residential Authorization: Pursuant to HBMC § 17.58.020, Precise Development Plan review is required for remodels of 1,500 square feet or more in any zone. Precise Development Plans shall be decided upon by the Planning Commission. Additionally, Pursuant to HBMC §17.58.010 the purpose of Precise Development Plans is to ensure that new development supports the goals and objectives of the General Plan and other adopted plans and guidelines. The applicant proposes the interior and exterior remodel of a 14,021-square-foot two-story multi-tenant commercial building. Therefore, the project requires the approval of a Precise Development Plan. Project Description The proposed project would renovate the existing 14,021-square-foot, two-story, multi- tenant building. The project would also include decommissioning approximately 1,340 square feet on the second floor and adding a 3,654-square-foot third story to the building for office use. The project would result in the square footage of the building decreasing by 194 square feet. A transformer would be located in a 172-square-foot enclosed space on the first floor with access from a roll up door on 10th court. To comply with southern California Edison guidelines, a 160 square foot area on the second floor above the Page 157 of 324 City of Hermosa Beach | Page 3 of 9 transformer will be clear and open. The property currently does not have a trash enclosure on site. The proposed project would include a trash room and loading room on the first floor both accessible from 10th Court (Attachment 3). The project also includes a lot line adjustment to merge the three parcels the existing building is developed over into one parcel. (Attachment 4). Discussion: Nonconformity The building is currently nonconforming as it does not meet required parking, setbacks, and the north, west, and east sides of the building sit over property lines. Pursuant to HBMC section 17.52.030(B)(1)(b), any existing nonconforming portions of the structure (e.g. a wall nonconforming to a yard requirement, or a roof non-conforming to height requirements) may be partially modified or altered only to the extent necessary to satisfy the Uniform Building Code as recommended by a certified structural engineer but shall not be completely removed and replaced, and if completely removed must be brought into compliance with current requirements. Criteria Required Provided LOT STANDARDS HEIGHT: 30 ft 28ft, 9.6in YARDS: Front Not required 0 feet Side 5 ft 0 ft (existing, no change) Rear 5 ft 1st floor: 2 ft, 11 in (existing, no change) 2nd floor: 5 ft, 10 inch 3rd floor: 5ft, 10 inch PARKING: Total Parking Spaces Minimum 0 existing No additional stalls are required if building square footage does not increase 0 stalls Page 158 of 324 City of Hermosa Beach | Page 4 of 9 A licensed structural engineer prepared a memo to clarify that the north wall of the property does not meet basic performance objectives. The existing wall will not be entirely abandoned. The proposed alterations to the wall will mitigate the performance deficiency and will meet current building code. Site/Floor plan The project proposes decreasing square footage on the first and second floors to accommodate the addition. The proposed project would decrease the 7,724-square-foot first floor to 7,179 square feet and decrease the 6,297-square-foot second floor to 2,994 square feet. Overall, the project would also include decommissioning approximately 1,340 square feet on the second floor and adding a 3,654 square-foot third story to the building for office use. The project would result in the square footage of the building decreasing by 194 square feet. Staff recommend a special condition of approval expressly prohibiting the use of this area without accounting for parking and would be walled off to prevent use of the area. Additionally, the transformer would be located in a 172-square-foot enclosed space on the first floor with access from a roll-up door on 10th court. To comply with Southern California Edison guidelines, a 160 square foot area on the second floor above the transformer will be clear and open. The property currently does not have a trash enclosure and incorporates a room for trash and recycling on the northside of the building that will be accessible from 10th court. Parking/Loading The property currently has no off-street parking. Pursuant to HBMC § 17.44.015, additions greater than 10 percent or 500 square feet, additional parking in accordance with this Chapter shall be provided for any alteration which would change the building square footage on site by more than 10 percent or 500 square feet, whichever is greater. The existing commercial building is 14,021 square feet. The project would include decommissioning approximately 1,340 square feet on the second floor and adding a 3,654 third story. The proposed project would decrease the square footage of the building by 194 square feet. Therefore, the proposed project would not increase the usable square footage and would not require additional parking. The property also currently has no loading area. The proposed project would create a ground level loading room accessible by a grade level roll up door off 10th Court. Landscape The project does not propose landscaping. Any future onsite landscaping would be subject to HBMC Chapter 8.60, Water Efficient Landscaping. Page 159 of 324 City of Hermosa Beach | Page 5 of 9 Design The development proposes a contemporary architectural style and would utilize several materials, such as metal paneling, aluminum and glass on the storefront, and incorporates stucco, aluminum and glass curtain walls to break the monotony and create visual interest. The pedestrian entryway closest to the walk street would be redesigned to be arched, thus keeping consistent with the other windows and entryways on the east side of the building. Additional service doors would be installed on the north side of the building off Tenth Court. Additional windows would be installed on the south side of the building. Historic Assessment The City’s General Plan identified the property as a potential historic resource in the windshield survey prepared as part of the General Plan Program Environmental Impact Report. All proposed alterations and demolitions of buildings identified on the City’s survey of potential historic resources are required to be evaluated by a qualified historic preservationist to determine if the proposed demolition or alteration would result in the degradation of a historically significant site. As such, a historic resource assessment was prepared for the property by Page & Turnbull in April 2024 (Attachment 5). The historic resource assessment found that 901 Hermosa Avenue is not currently listed on any local, state, or federal register of historic resources. The structure is a local example of a 1920s automobile showroom. The building is a modest representation of the Mission Revival architectural style, as it is less elaborate and ornamented than other high-style examples in the region. In addition, some of the original features, such as windows and doors, have been replaced or infilled. The assessment finds that the building does not possess a level of architectural distinction, nor is it associated with events or individuals of significance; the property does meet the eligibility criteria for the National or California Register of Historical Resources. The city’s Historic Preservation Ordinance has been implemented voluntarily, and this building has not been locally designated as a landmark. The assessment concludes that the project is not a historic resource for the purposes of CEQA. Lot Line Adjustment A lot line adjustment is the process under the State Subdivision Map Act that is used to change the property lines of existing parcels. The process can be used to do a number of things, such as: combine up to four (4) adjacent parcels into one (1) parcel, alter the boundary between up to four (4) parcels, or reconfigure the shapes of up to four (4) parcels. Page 160 of 324 City of Hermosa Beach | Page 6 of 9 The property is a corner lot consisting of three parcels, lots 25-27, and has the following dimensions. Existing Lot Configuration Lot Width Length 25 30 ft 95 ft 26 26 ft- 2 in 95 ft 27 30 ft 95 ft The project would adjust the lot lines to create a single parcel with dimensions of 86 feet 2 inches wide by 95 feet long, totaling 8,177 square feet. Findings: Pursuant to Hermosa Beach Municipal Code §17.58.020, remodels of 1,500 square feet or more in any zone shall be subject to a Precise development Plan (PDP). Pursuant to Hermosa Beach Municipal Code §17.58.040, all projects requiring a Precise Development plan must make the following findings to approve the PDP: 1. The design, layout, and other physical features of the project comply with all other applicable provisions of this Title and all other titles of the Hermosa Beach Municipal Code; The proposed project would renovate the existing 14,021-square-foot two-story multi-tenant building and would include decommissioning approximately 1,340 square feet on the second floor, adding a 3,654 square-foot third story to the building for office use, and would result in the square footage of the building decreasing by 194 square feet. A transformer would be located in a 172-square-foot enclosed space on the first floor with access from a roll-up door on 10th court. To comply with southern California Edison guidelines, a 160-square-foot area on the second floor above the transformer will be clear and open. The project has been reviewed for compliance, and the design, layout, and physical features of the proposed development would comply with all applicable provisions of the Municipal Code. 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; The subject property has a General Plan land use designation of Community Commercial. The purpose of this designation is to provide opportunities and locations for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is also located within the Downtown District character area. The vision of this district is to enhance building form and orientation and maintain the pedestrian realm along Pier Avenue while transforming the realm on Hermosa Avenue. The Downtown District intended uses would be services and activities associated with the local beach culture to residents as well as visitors to the city. Additionally, The Downtown character district areas specifies a desired character and building area form that includes 1) Many of the unique buildings, Page 161 of 324 City of Hermosa Beach | Page 7 of 9 streetscape features, and public spaces are iconic or historic in nature, and new buildings should be carefully integrated to retain the town’s eclectic charm and 2) Buildings should be two to three stories in height, cover most or all of the parcel, and may abut neighboring structures. The general plan states the maximum floor area ratio (FAR) for a community commercial land use designation is 1.25. The property is currently nonconforming with a FAR of 1.7. the proposed project would maintain this nonconforming FAR. The proposed project would revitalize the existing building and incorporate a more modern aesthetic, inclusive of a variety of materials to create interest and break monotony. The large arched storefront windows on the first floor would be maintained. The modern aesthetic would largely come into play in the new third- floor addition with the installation of numerous windows and the incorporation of different materials. Additionally, the staff proposes a condition of approval prohibiting tinting and reflective glass. Therefore, the proposed project is consistent with the General Plan. 3. The design, layout, and other physical features of the project comply with any design or development standards applicable to the zone, unless waived or General Plan Consistency Goals & Policies Findings Land Use Element Goal 1: Create a sustainable urban form and land use patterns that support a robust economy and high-quality life for residents Policy 1.3 Access to daily activities. Strive to create sustainable development patterns such that the majority of residents are within walking distance to a variety of neighborhood goods and services Policy 1.7 Compatibility of Uses. Ensure the placement of new uses does not create or exacerbate nuisances between different types of land uses. The proposed project will increase access to services in the community and contribute to more options for residents to have access to daily activities. All future uses will be subject to compliance with the permitted uses of the C-3 zone per the city’s municipal code, Parks & Open Space Element Goal 5. Scenic vistas, viewpoints, and resources are maintained or enhanced Policy 5.7 Light pollution. Preserve nighttime skyward views and reduce glare by minimizing shoreline lighting levels. Nighttime views would be protected by a condition of approval requiring all exterior lighting to be downcast to minimize light pollution. Page 162 of 324 City of Hermosa Beach | Page 8 of 9 modified pursuant to the provisions of this Title. The proposed project would renovate the existing 14,021-square-foot two-story multi-tenant building and would include decommissioning approximately 1,340 square feet on the second floor, adding a 3,654 square-foot third story to the building for office use, and would result in the square footage of the building decreasing by 194 square feet. The development proposes a contemporary architectural style and would utilize several materials, such as metal paneling, aluminum and glass on the storefront, and incorporate stucco, aluminum and glass curtain walls to break the monotony and create visual interest. The proposed design will be compatible with buildings in the surrounding area. Moreover, the project complies with all design development standards. Pursuant to the state Subdivision Map Act (California Government Code Section 66412(d)), a tentative map, parcel map, or final map shall not be required as a condition to the approval of a lot line adjustment between four or fewer existing adjoining parcels, where the land taken from one parcel is added to an adjoining parcel, and where a greater number of parcels than originally existed is not thereby created, if the lot line adjustment is approved by the City. The City must limit its review and approval to a determination of whether the parcels resulting from the adjustment will conform to the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances. Conditions and exactions placed on approval must be limited to those necessary to comply with the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances, to require the prepayment of real property taxes prior to the approval of the lot line adjustment, or to facilitate the relocation of existing utilities, infrastructure, or easements. In addition, the City cannot require a record of survey for a lot line adjustment unless otherwise required by law. The proposed lot line adjustment consolidates three existing lots into a single 8,177-square-foot lot (86 feet 2 inches wide by 95 feet) that is consistent with the General Plan, Zoning, applicable Coastal Plan, and building regulations. Environmental Analysis: Pursuant to the California Environmental Quality Act (CEQA), the proposed project qualifies for a Class 1 categorical exemption, existing facilities as defined in section 15301 of the CEQA Guidelines, as it consists of internal and exterior modification of an existing building. The proposed project also qualifies for a Class 5 categorical exemption, minor alterations in land use limitations, as defined in section 15305, as the project consists of a minor lot line adjustment. Additionally, a historic resource assessment was prepared for the project by Page & Turnbull in April 2024, and it was determined that the property is not considered a historic resource for the purposes of CEQA. Public Notification: Page 163 of 324 P a g e 1 of 10 CITY OF HERMOSA BEACH RESOLUTION NO. 25-XX A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, APPROVING A PRECISE DEVELOPMENT PLAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REMODEL AN EXISTING 14,021 SQUARE-FOOT TWO-STORY COMMERCIAL BUILDING AND CONSOLIDATE THREE EXISTING PARCELS INTO A SINGLE LOT, AND DETERMINING THAT THE PROJECT IS CATEGORICALLY EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) PURSUANT TO SECTION 15301, CLASS 1 and SECTION 15305, CLASS 5 OF THE CEQA GUIDELINES. The Planning Commission of the City of Hermosa Beach does hereby resolve, and order as follows: WHEREAS, on May 30, 2023, the applicant, Kyle Ransford, filed an application for a Precise Development Plan and Lot Line Adjustment, to remodel and add to an existing 14,021 square-foot two-story commercial building (the “Project”) located at 901 Hermosa Avenue (the “site”). The project proposes to add a third story to the exiting building, increasing the building height to 28 feet 9.6 inches, and reconfigure the existing building layout, resulting in a decrease of 194 square feet of usable floor area for a remodeled multi-tenant commercial building. Additionally, the lot line adjustment will consolidate three existing parcels at the project site into a single lot; and WHEREAS, the Planning Commission, at its public meeting of October 21, 2025, conducted a public hearing, and considered all testimony and evidence, both oral and written, that was presented to the Planning Commission; and WHEREAS, the proposed project is Categorically Exempt from the California Environmental Quality Act as defined in section 15301, Class 1, Existing Facilities as the project consists of internal and exterior modification of an existing building. The proposed project also qualifies for a Class 5 categorical exemption, Minor Alterations in land use limitations, as defined in section 15305, as the project consists of a minor lot line adjustment. Additionally, a historic resource assessment was prepared for the project by Page & Turnbull in July 2024 and determined that the property is not considered a historical resource for the purposes of CEQA and will not cause a substantial adverse change in the significance of a historical resource, as per CEQA Guidelines (14 CCR § 15064.5(a)), 901 Hermosa Avenue is not currently listed in a local register of historic resources or in the California Register and Page 164 of 324 P a g e 2 of 10 is not eligible for listing in the California Register, the property is not a historic resource for the purposes of the CEQA.. Moreover, none of the exceptions to the categorical exemption(s) apply under section 15300.2. The project is not located in a particularly sensitive environment such that its impact on the environment will be significant, and will not result in a significant cumulative impact of successive projects of the same type in the same place over time, or have a significant effect on the environment due to unusual circumstances. The project will not damage a scenic highway or scenic resources within a state scenic highway as no scenic state highway exist in the vicinity of the project, nor is the project located on a hazardous waste site. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. Based on the testimony and evidence received, the Planning Commission hereby further finds, determines, and declares the following pertaining to the application for a Precise Development Plan (PDP 23-04), pursuant to section 17.58.040 of the Hermosa Beach Municipal Code (“HBMC”): 1. The design, layout, and other physical features of the project comply with all other applicable provisions of this Title and all other titles of the Hermosa Beach Municipal Code; The proposed project would renovate the existing 14,021- square-foot two-story multi-tenant building and would include decommissioning approximately 1,340 square feet on the second floor, adding a 3,654 square-foot third story to the building for office use, and would result in the square footage of the building decreasing by 194 square feet. A transformer would be located in a 172- square-foot enclosed space on the first floor with access from a roll up door on 10th court. To comply with Southern California Edison guidelines, a 160-square-foot area on the second floor above the transformer will be clear and open. The project has been reviewed for compliance, and the design, layout, and physical features of the proposed development would comply with all applicable provisions of the Municipal Code. 2. The design, layout, and other physical features of the project are consistent with the General Plan, and any applicable specific plan or design guidelines; The subject property has a General Plan land use designation of Community Commercial. The purpose of this designation is to provide opportunities and locations for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is also located within the Downtown District character area. The Page 165 of 324 P a g e 3 of 10 vision of this district is to enhance building form and orientation and maintain the pedestrian realm along Pier Avenue while transforming the realm on Hermosa Avenue. The Downtown District intended uses are services and activities associated with the local beach culture to residents as well as visitors to the city. Additionally, the Downtown character district areas specifies a desired character and building area form that includes 1) “many of the unique buildings, streetscape features, and public spaces are iconic or historic in nature, and new buildings should be carefully integrated to retain the town’s eclectic charm,” and 2) “buildings should be two to three stories in height, cover most or all of the parcel, and may abut neighboring structures.” The General Plan states the maximum floor area ratio (F.A.R.) for a community commercial land use designation is 1.25. The property is currently nonconforming with a FAR of 1.7, and the proposed project would maintain this nonconforming FAR. The proposed project would revitalize the existing building and incorporate a more modern aesthetic inclusive of a variety of materials to create interest and break monotony. The large arched storefront windows on the first floor would be maintained. The modern aesthetic would largely come into play in the new third floor addition with the installation of numerous windows and the incorporation of different materials. Additionally, staff proposes a condition of approval prohibiting tinting and reflective glass. Therefore, the proposed project is consistent with the General Plan. General Plan Consistency Goals & Policies Findings Land Use Element Goal 1: Create a sustainable urban form and land use patterns that support a robust economy and high-quality life for residents Policy 1.3 Access to daily activities. Strive to create sustainable development patterns such that the majority of residents are within walking distance to a variety of neighborhood goods and services Policy 1.7 Compatibility of Uses. Ensure the placement of new uses does not create The proposed project will increase access to services in the community and contribute to more options for residents to have access to daily activities. All future uses will be subject to compliance with the permitted uses Page 166 of 324 P a g e 4 of 10 3. 3. The design, layout, and other physical features of the project comply with any design or development standards applicable to the zone, unless waived or modified pursuant to the provisions of this Title. The subject property has a General Plan land use designation of Community Commercial. The purpose of this designation is to provide opportunities and locations for uses designed to serve the shopping, dining, and employment desires of the entire community. The site is also located within the Downtown District character area. The vision of this district is to enhance building form and orientation and maintain the pedestrian realm along Pier Avenue while transforming the realm on Hermosa Avenue. The Downtown District intended uses would be services and activities associated with the local beach culture to residents as well as visitors to the city. Additionally, The Downtown character district areas specifies a desired character and building area form that includes 1) Many of the unique buildings, streetscape features, and public spaces are iconic or historic in nature, and new buildings should be carefully integrated to retain the town’s eclectic charm and 2) Buildings should be two to three stories in height, cover most or all of the parcel, and may abut neighboring structures. The general plan states the maximum floor area ratio (FAR) for a community commercial land use designation is 1.25. The property is currently nonconforming with a FAR of 1.7. the proposed project would maintain this nonconforming FAR. The proposed project would revitalize the existing building and incorporate a more modern aesthetic inclusive of a variety of materials to create interest and break monotony. The large arched storefront windows on the first floor would be maintained. The modern aesthetic would largely come into play in the new third floor addition with the installation of numerous windows and the incorporation of different materials. Additionally, staff proposes a condition of approval prohibiting or exacerbate nuisances between different types of land uses. of the C-3 zone per the city’s municipal code. Parks & Open Space Element Goal 5. Scenic vistas, viewpoints, and resources are maintained or enhanced Policy 5.7 Light pollution. Preserve skyward nighttime views and lessen glare by minimizing lighting levels along the shoreline. Nighttime views would be protected by a condition of approval requiring all exterior lighting to be downcast to minimize light pollution. Page 167 of 324 P a g e 5 of 10 tinting and reflective glass. Therefore, the proposed project is consistent with the General Plan. SECTION 2. Based on the testimony and evidence received, the Planning Commission hereby further finds, determines, and declares the following pertaining to the application for a Lot Line Adjustment (LLA 23-03) pursuant to the Subdivision Map Act, California Government Code Section 66412(d): 1. Pursuant to the state Subdivision Map Act (California Government Code Section 66412(d)), a tentative map, parcel map, or final map shall not be required as a condition to the approval of a lot line adjustment between four or fewer existing adjoining parcels, where the land taken from one parcel is added to an adjoining parcel, and where a greater number of parcels than originally existed is not thereby created, if the lot line adjustment is approved by the City. 2. The City must limit its review and approval to a determination of whether the parcels resulting from the adjustment will conform to the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances. Conditions and exactions placed on approval must be limited to those necessary to comply with the local general plan, any applicable specific plan, any applicable coastal plan, and zoning and building ordinances, to require the prepayment of real property taxes prior to the approval of the lot line adjustment, or to facilitate the relocation of existing utilities, infrastructure, or easements. In addition, the City cannot require a record of survey for a lot line adjustment unless otherwise required by law. The proposed lot line adjustment consolidates three existing lots into a single 8,177-square- foot lot (86 feet 2 inches wide by 95 feet ) that is consistent with the General Plan, Zoning, applicable Coastal Plan, and building regulations. SECTION 3. Based on the foregoing, the Planning Commission hereby approves the subject Precise Development Plan (PDP 23-04) and Lot Line Adjustment (LLA 23-03) to remodel and add to an existing 14, 021 square-foot two-story commercial building located at 901 Hermosa Avenue. The lot line adjustment consolidates three existing parcels into a single lot as set forth in Planning Commission Resolution 25-10, subject to the following Conditions of Approval: General Conditions 1. The development and continued use of the property shall be in conformance with submitted plans received and reviewed by the Planning Commission at its meeting of Page 168 of 324 P a g e 6 of 10 October 21, 2025, in accordance with the conditions below. The Community Development Director may approve minor modifications that do not otherwise conflict with the HBMC or requirements of this approval. 2. The project shall fully comply with all requirements of the Downtown Commercial (C- 2) Zone as applicable of the Municipal Code, including but not limited to: a. Height, including all required roof-mounted equipment, shall fully comply with the 30-foot height limit. Precise building height compliance shall be reviewed at the time of the building plan review, to the satisfaction of the Community Development Director. b. Architectural treatments and accessory facilities shall be as shown on building elevations, site, and floor plans. 3. The project shall comply with all requirements of the City of Hermosa Beach Building Division, Public Works Department, Los Angeles County Fire Department, and the HBMC. 4. This approval shall not be effective for any purposes until the permittee, Kyle Ransford, and the owners of the property involved have filed at the office of the Planning Division of the Community Development Department signed affidavits stating that they are aware of, and agree to accept, all the conditions of this grant. The Conditional Use Permit and Precise Development Plan shall be recorded, and proof of recordation shall be submitted to the Community Development Department prior to the issuance of a building permit. 5. Approval of this permit shall expire twenty-four (24) months from the date of approval by the Planning Commission unless significant construction or improvements or the use authorized hereby has commenced. One or more extensions of time may be requested. No extension shall be considered unless requested, in writing to the Community Development Director including the reason therefore, at least 60 days prior to the expiration date. No additional notice of expiration shall be provided. 6. The Planning Commission may review this Precise Development Plan and may amend the subject conditions or impose any new conditions if deemed necessary to mitigate detrimental effects on the surrounding neighborhood. 7. The subject property shall be developed, maintained, and operated in full compliance with the conditions of this permit and any law, statute, ordinance, or other regulation applicable to any development or activity on the subject property. Failure of the permittee to cease any development or activity not in full compliance shall be a violation of these conditions. 8. To the extent permitted by law, permittee shall defend, indemnify and hold harmless Page 169 of 324 P a g e 7 of 10 the City of Hermosa Beach, its City Council, its officers, employees and agents (the “indemnified parties”) from and against any claim, action, or proceeding brought by any party against the indemnified parties to attack, set aside, or void any permit or approval for this project authorized by the City, including (without limitation) reimbursing the City its actual attorney’s fees and costs in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. The permittee shall reimburse the City for any court and attorney's fees which the City may be required to pay as a result of any claim or action brought against the City because of this permit. Although the permittee is the real party in interest in an action, the City may, at its sole discretion, participate at its own expense in the defense of the action, but such participation shall not relieve the permittee of any obligation under this condition. 9. Each of the above conditions is separately enforced, and if one of the conditions of approval is found to be invalid by a court of law, all the other conditions shall remain valid and enforceable. Planning 10. All Conditions of Approval shall be printed verbatim on all plans submitted for plan review to the Community Development Department. These conditions shall be indexed on the cover sheet and referenced on the site plan. 11. Landscaping: Any proposed onsite landscaping shall comply with HBMC chapter 8.60, Water Efficient Landscaping and HBMC section 8.44.095(F)(1) and must be submitted to the Community Development Department and be approved prior to issuance of the building permit. 12. Walls/Fences: All walls, or fences, including the visible surface of retaining walls, shall be constructed of, or treated with, an aesthetically pleasing material approved by the Community Development Director, including, but not limited to, masonry block designed and manufactured to be exposed (e.g., split-face, scored, textured or striated); surface treated masonry (e.g. stucco or paint); wrought iron or simulated wrought iron; brick; wood; stucco or paint. Plain gray untreated block not designed or manufactured to be exposed and chain link fences are prohibited (HBMC Section 17.46.130.E). 13. Lighting: Outdoor lighting and lighting for signs associated with commercial uses designed so as not to adversely impact residences. No flashing, blinking, or high- intensity lighting. Adequate lighting to illuminate parking areas and corridors to access parking and public sidewalk. Lighting for signs may only be illuminated during business hours. 14. Lighting: All lighting shall be directed downward, fully shielded and illumination shall be contained within the property boundaries. Lighting shall be energy conserving and Page 170 of 324 P a g e 8 of 10 motion detector lighting shall be used for all lighting except low-level (3 feet or less in height) securing lighting and porch lights. Exterior lighting shall not be deemed finally approved until 30 days after installation, during which period the building official may order the dimming or modification of any illumination found to be excessively brilliant or impacting to nearby properties. 15. Signs: Signs shall be limited to the commercial space frontage pursuant to the requirements of HBMC Chapter 17.50, Signs. 16. All proposed mechanical equipment shall be located outside of required setbacks in accordance with the Hermosa Beach Municipal Code. All mechanical equipment must be screened from public view subject to the review and approval of the Community Development Director or designee. 17. Use of the second-floor decommissioned area shall be strictly prohibited from use. 18. At the time of plan check approval, the applicant shall submit a building permit. The applicant shall remit a construction plan, which shall include a plan for how it will maintain \the existing perimeter walls throughout the various construction phases. 19. The use of tinted and/or reflective glass is prohibited. 20. Prepayment of all taxes as required California Government Code Section 66412 and any fees required by the City shall be evidenced prior to recordation of the Certificate of Compliance. 21. A Certificate of Compliance and legal descriptions in a form approved by the City and compliant with the Subdivision Map Act shall be submitted consistent with the plans approved by the Planning Commission, approved by the Community Development Director and City Attorney, and recorded with the Office of the Los Angeles County Recorder and evidence of recording shall be submitted to the Community Development Department within one (1) year of this approval. 22. Construction projects within the city shall demonstrate compliance with all applicable standards of the Southern California Air Quality Management District, including the following provisions of District Rule 403: · All unpaved demolition and construction areas shall be wetted at least twice daily during excavation and construction, and temporary dust covers shall be used to reduce dust emissions and meet SCAQMD Rule 403. Wetting could reduce fugitive dust by as much as 50 percent. · The construction area shall be kept sufficiently dampened to control dust caused by grading and hauling, and at all times provide reasonable control of dust caused by wind. · All clearing, earth moving, or excavation activities shall be discontinued during periods of high winds (i.e., greater than 15 mph), to prevent excessive amounts of Page 171 of 324 P a g e 9 of 10 dust. · All dirt/soil loads shall be secured by trimming, watering, or other appropriate means to prevent spillage and dust. · All dirt/soil materials transported off-site shall be required to cover their loads as required by California Vehicle Code Section 23114 to prevent excessive amount of dust. · General contractors shall maintain and operate construction equipment to minimize exhaust emissions. · Trucks having no current hauling activity shall not idle but shall be turned off. 23. In accordance with Section 2485 in Title 13 of the California Code of Regulations, the idling of all diesel-fueled commercial vehicles (weighing over 10,000 pounds) during construction shall be limited to 5 minutes at any location. 24. The project shall comply with South Coast Air Quality Management District Rule 1113, limiting the volatile organic compound content of architectural coatings. 25. Construction projects within the city shall install odor-reducing equipment in accordance with South Coast Air Quality Management District Rule 1138. 26. Project applicants shall identify all measures to reduce air pollutant emissions below SCAQMD thresholds prior to the issuance of building permits. Should attainment of SCAQMD thresholds be determined to be infeasible, construction contractors shall provide evidence of this to the City and will be encouraged to apply for SCAQMD SOON funds. 27. As a standard condition of approval for future development projects implemented under PLAN Hermosa that involve ground disturbance or excavation: · For any project where earthmoving or ground disturbance activities are proposed at depths that encounter older Quaternary terrace deposits, a qualified paleontologist shall be present during excavation or earthmoving activities. · If paleontological resources are discovered during earthmoving activities, the construction crew shall immediately cease work in the vicinity of the find and notify the City. The project applicant(s) shall retain a qualified paleontologist to evaluate the resource and prepare a recovery plan in accordance with Society of Vertebrate Paleontology guidelines (1996). The recovery plan may include, but is not limited to, a field survey, construction monitoring, sampling and data recovery procedures, museum storage coordination for any specimen recovered, and a report of findings. Recommendations in the recovery plan that are determined by the lead agency to be necessary and feasible shall be implemented before construction activities can resume at the site where the paleontological resources were discovered. Page 172 of 324 P a g e 10 of 10 Building 28. The previously provided LFA Report dated 10/8/24 states that the existing wall will not be entirely abandoned and that alterations will be made to mitigate structural deficiencies. Structural plans have not yet been reviewed to determine the extent of this work and how it may encroach into the PROW. No new walls or foundation footings (including underpinning) will be allowed within the public right-of-way without the approval of Public Works. 29. Must reference all gross square footage on page G-202, to include square footage that is being designated and labeled as “deactivated space”. 30. Must clarify access areas on page G-202/G-203/G-204: a. It appears that the access path to the proposed electrical room is less than 3 feet. b. The South egress path and door swing appear to swing out onto the encroachment area, subject to the approval of Public Works. c. The doors on the North side of the building for the proposed fire room and trash room appear to swing into the public right of way, subject to the approval of Public Works. 31. Must acquire approval from Public Works if the existing wall encroaching on the Public Way is to be maintained in that location. 32. Referencing page AD-111: Any work that exceeds 50% demolition of the existing framing will be considered new and is subject to the development and building standards of a new building. The following items will require plan review and approval, prior to permit issuance: 33. Pedestrian and adjacent property protection plans will be required for review and approval. 34. Submit all Architectural, Geotechnical Reports, LID, Site Drainage, Energy Sheets/Calculations, and Structural Plans for plan review and approval and acquire all required permits. 35. Submittal and plan approval required to LA County Fire Land Development Unit for the site plans and floor plans 36. Submittal and plan approval required to LA County Fire for Fire Sprinklers and Fire Alarm Systems. Public Works 37. No new walls or foundation footing will be allowed to be constructed on or over the Page 173 of 324 P a g e 11 of 10 public right-of-way. 38. A Residential Encroachment permit is required for non-confirming structures located over or within the public right-of-way. The following conditions of approval shall be satisfied, subject to the satisfaction of the Public Works Director or designee. 39. Prior to issuance of a Building Permit, an approved civil engineering plans prepared by a licensed civil engineer, and approved by Public Works, addressing grading, undergrounding of all utilities, pavement, sidewalk, curb and gutter improvements, on-site and off-site drainage (no sheet flow permitted), installation of utility laterals, and all other improvements necessary to comply with the Municipal Code and Public Works specifications, shall be filed with the CD Department. 40. Civil engineering plans shall include adjacent properties/structures, sewer laterals, and storm drain main lines on the street. 41. Project construction shall protect private and public property in compliance with Sections 15.04.070 and 15.04.140. No work in the public right of way shall commence unless and until all necessary permits are attained from the Public Works Department including, if required, an approved Residential or Commercial Encroachment Permit. 42. Sewer manhole rim/lid elevations must be submitted prior to grading and plan check. 43. Sewer lateral video must be submitted with plan check submittal if the developer plans to use the existing sewer lateral. Sewer lateral work may be required after reviewing the sewer lateral video. 44. The project must comply with Storm Water and Urban Runoff Pollution Control Regulations (HBMC Ch. 8.44). Implement required Low Impact Development Standards, provide calculations and documents i.e. Appendix D and E of the Storm Water LID Guidelines, submit at time of grading and plan check along with an erosion control plan. SECTION 4. Pursuant to the Code of Civil Procedure Section 1094.6, any legal challenge to the decision of the Planning Commission, after exhaustion of any available administrative remedies, must be made within 90 days after the final decision by the City Council. The Hermosa Beach City Council may on its own initiative review all actions of the Planning Commission. If the City Council does not initiate review of this decision as set forth in Hermosa Beach Municipal Code Section 2.52.040, this decision will become final. PASSED, APPROVED, and ADOPTED on the 21st of October, 2025. ______________________________________________________________________________________ Page 174 of 324 P a g e 12 of 10 VOTE: AYES: NOES: ABSTAIN: ABSENT CERTIFICATION I hereby certify the foregoing Resolution PC 25-XX is a true and complete record of the action taken by the Planning Commission of the City of Hermosa Beach, California, at its regular meeting of October 21, 2025. Kate Hirsh, Chair Alison Becker, Secretary Date Page 175 of 324 Palm DrManhattan AveBeach D r 9th S t 7th S t 11th S t 10th S t Hermosa AveBeach D r 8th S t 6th S t P i e r A v e The St rand 7th C t 8th C t Sunset Dr 9th C t 10th C t 12th C t 11th C t Monterey B lvd Pier P l a z a Bayview DrProject Zoning Map Planning CommissionOctober 21, 2025 Description 901 Hermosa Avenue APN: 4187-003-028 Zone: C-2 Downtown Commercial Precise Development Plan Legend R-1 Single Family Residential R-1A Limited Single-Family Residential R-2 Two Family Residential R-2B Limited Multiple Family Residential R-3 Multiple Family Residential R-P Residential-Professional RPD Residential Planned Development R-3PD Multiple Family Planned Development C-1 Neighborhood Commercial C-2 Downtown Commercial C-3 General Commercial M-1 Light Manufacturing OS Open Space OS-1 Restricted Open Space OS-2 Restricted Open Space OS-O Open Space Overlay MHP Mobile Home Park SPA Specific Plan Area (Residential) SPA Specific Plan Area (Commercial) 500' Notification Radius Page 176 of 324 City of Hermosa Beach | Page 9 of 9 For the October 21, 2025, Planning Commission hearing, a total of 696 public hearing notices were mailed to the applicant, occupants, and property owners of properties within a 500-foot radius on October 11, 2025. A legal ad was published on October 11, 2025, in the Daily Breeze, a newspaper of general circulation. An eBlast was sent to all subscribers on October 9, 2025 and it was posted on our website and bulletin board. Additionally, the applicant received a notice poster to post on-site and provided proof of posting a minimum of ten days in advance of the public hearing, in accordance with HBMC 17.68.050. Public notification materials are included as Attachment 6. As of the writing of the report, one public comment expressing opposition to the project was received (Attachment 7). Attachments: 1. Resolution 25-XX 2. Zoning Map 3. Project Plans 4. Lot Line Adjustment 5. Historic Resource Assessment 6. Public Notification Package 7. Public Comment Respectfully Submitted by: Kaneca Pompey, Contract Planner Concur: Alexis Oropeza, Planning Manager Approved: Sarah Locklin, Interim Assistant City Attorney Approved: Alison Becker, Community Development Director Page 177 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 12 OF 136 G-101 COVER SHEET ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 ENTRY 101 DIMENSION TO FACE DIMENSION TO CENTERLINE REVISION NUMBER NEW ELEVATION BUILDING SECTION WALL SECTION DETAIL INTERIOR ELEVATION - MULTIPLE WALLS GRIDLINE TO FACE OF STRUCTURE EXISTING ELEVATION CONTROL POINT / DATUM ALIGN FINISH DESIGNATION EQUIPMENT MARK PLUMBING FIXTURES NEW WALL EXISTING WALL INTERIOR ELEVATION - 1 WALL EXTERIOR ELEVATION ROOM NAME ROOM NUMBER WALL TYPE WINDOW MARK DIRECTION OF SLOPE TO DRAIN DOOR MARK DASHED LINES INDICATE HIDDEN, OVERHEAD OR ITEMS TO BE REMOVED PROPERTY LINE BUILDING FLOOR OR ELEVATION SOLID LINE BREAK LINE - MATERIAL TO CONTINUE EXHAUST FAN GRIDLINE ON CENTER OF COLUMN FIRE SPRINKLER SMOKE DETECTOR KEYNOTE DIMMER/VACANCY SENSOR WALK STREET SETBACK 100 A 100 1 SD WS SB SP PL-01 PT-01 APP-01 1 COVER SHEET & GENERAL INFO DIAGRAMS SURVEY - MAPPING DEMOLITION SITE DEMOLITION PLANS CIVIL G-101 G-102 G-201 G-202 G-203 G-204 V-101 AD-101 AD-111 AD-112 AD-113 C-000 C-100 C-210 C-300 C-400 COVER SHEET GENERAL NOTES SITE PHOTOS CURRENT VS PROPOSED SQ FT CODE REPORT CODE PLANS & SECTIONS SURVEY PLAN DEMOLITION SITE PLAN DEMOLITION 1st FLOOR PLAN DEMOLITION 2nd FLOOR PLAN DEMOLITION ROOF PLAN TITLE SHEET EROSION CONTROL PLAN GRADING AND DRAINAGE PLAN LOW IMPACT DEVELOPMENT PLAN UTILITY PLAN SITE PLANS FLOOR PLANS ELEVATIONS SECTIONS ENLARGED PLANS ASSEMBLY DETAILS SCHEDULES A-101 A-111 A-112 A-113 A-114 A-115 A-201 A-202 A-203 A-204 A-301 A-302 A-303 A-401 A-402 A-403 A-404 A-405 A-501 A-502 A-601 A-602 A-603 SITE PLAN FOUNDATION PLAN 1st FLOOR PLAN 2nd FLOOR PLAN 3rd FLOOR PLAN ROOF PLAN EXISTING ELEVATIONS EXISTING ELEVATIONS PROPOSED ELEVATIONS PROPOSED ELEVATIONS BUILDING SECTIONS BUILDING SECTION WALL SECTIONS STAIR 01 PLAN & SECTION STAIR 02 PLAN & SECTION STAIR 03 & ELEVATOR 02 PLAN & SECTION ENLARGED BATHROOM PLANS & ELEVATIONS ENLARGED KITCHEN PLANS & ELEVATIONS DETAILS - WALL ASSEMBLIES DETAILS - FLOOR / ROOF / CEILING ASSEMBLIES FINISH SCHEDULE & MATERIAL LEGEND DOOR + WINDOW SCHEDULES CURTAIN WALL SCHEDULE PROJECT INFORMATION PROJECT DIRECTORY ABBREVIATIONS RELEVANT CODESDEFERRED SUBMITTALS FIRE SPRINKLER NOTE SYMBOLS VICINITY MAP OTHER SHEET INDEX PROJECT ADDRESS 901 HERMOSA LEGAL DESCRIPTION LOT 25, 26 AND 27, BLOCK 10. HERMOSA BEACH, M.B. 1-25-26 APN# 4187-003-028 ZONE C2 (DOWNTOWN COMMERCIAL ZONE) LOT AREA (NET) 8,180 SF OCCUPANCY GROUP MERCANTILE OFFICE & STORAGE CONSTRUCTION TYPE TYPE V NO. OF STORIES THREE STORIES FIRE SPRINKLERS SPRINKLERS THROUGHOUT PARKING N/A SCOPE OF WORK MAJOR REMODEL OF EXISTING TWO-STORY COMMERCIAL STRUCTURE. PROPOSED WORK INCLUDES: REMOVE EXISTING EXTERIOR WALL FINISH AND INSTALL NEW FINISH OVER SUBSTRATE REMOVE EXISTING EXTERIOR DOORS AND REPLACE WITH NEW REMOVE EXISTING EXTERIOR WINDOWS AND REPLACE WITH NEW RECONFIGURE EXISTING INTERIOR SPACES PER PLANS. GC TO REMOVE DRYWALL AT ALL SURFACES AS NEEDED TO ACCOMMODATE REMODEL. EXISTING INTERIOR AND EXTERIOR LIGHTING TO BE REMOVED AND REPLACED EXISTING MECHANICAL EQUIPMENT AND DUCTWORK TO BE REMOVED AND REPLACED EXISTING ROOF AND ROOF DRAINAGE TO BE RENEWED. GC TO APPLY NEW FINISH TO EXISTING ROOF EXISTING FLOOR AND WALL FINISHES TO BE REMOVED THROUGHOUT EXISTING LOW VOLTAGE AND A/V SYSTEMS TO BE REMOVED AND REPLACED WITH NEW EXISTING PLUMBING FIXTURES TO BE REMOVED AND REPLACED WITH NEW. GC TO REWORK EXISTING PIPING AS NEEDED FOR NEW CONFIGURATION EXISTING HARDSCAPE, SOFTSCAPE, AND PLANTERS TO BE REMOVED. GC TO INSTALL NEW HARDSCAPE, SOFTSCAPE, AND PLANTERS PER PLANS REWORK EXISTING DRAINAGE AS NEEDED
 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2022 CMC, 2022 CEC, 2022 CPC, 2022 CRC CLIENT KYLE RANSFORD 901 HERMOSA PARTNERS LLC 2301 ROSECRANS AVENUE, SUITE 4130 EL SEGUNDO CA 90254 USA ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 ANTHONY@LANEY.LA (310) 870-7175 SURVEYOR DENN ENGINEERS 3914 DEL AMO BLVD, SUITE 921, TORRANCE, CA, 90503 (310) 542-9491 STRUCTURE + CIVIL LABIB FUNK + ASSOCIATES 319 MAIN STREET, EL SEGUNDO, CA 90245 (213) 239-9700 GEO-TECHNICAL ENGINEER NORCAL ENGINEERING 10641 HUMBOLT STREET, LOS ALAMITOS, CA 90720 (526) 799-9469 MEP NATIONAL ENGINEERING & CONSULTING, INC 30 THOMAS I, IRVINE, CA 92618 (714) 495-8004 @ AT A.F.F. ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE ACOUS ACOUSTICAL ADJ ADJUSTABLE ALUM ALUMINUM ANCH ANCHOR APPROX APPROXIMATELY ATTEN ATTENUATION BD BOARD BLDG BUILDING BLK BLOCK BM BEAM B.O. BOTTOM OF (C) COMPACT PARKING STALL CA CLEAR ANODIZED CAB CABINET CER CERAMIC CJ CONTROL JOINT CL CLOSET C.L. CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS DBL DOUBLE DTL DETAIL DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DN DOWN DS DOWNSPOUT DWG DRAWING EA EACH EL ELEVATION ELECT ELECTRICAL EQ EQUAL EQUIP EQUIPMENT (E) EXISTING EP ELECTRIC PANEL EXT EXTERIOR FD FLOOR DRAIN FIN. FINISH F.F.E. FINISH FLOOR ELEVATION FLR FLOOR FLUOR FLUORESCENT F.O. FACE OF FT FOOT FTG FOOTING FV FIELD VERIFY GA GAUGE GI GALVANIZED IRON GALV GALVANIZED GL GLASS GYP BD GYPSUM BOARD HD HEAD HDWD HARDWOOD HORIZ HORIZONTAL HT HEIGHT ID INSIDE DIAMETER IN INCH INSUL INSULATION INT     INTERIOR LAM     LAMINATE LAV     LAVATORY LT FXT  LIGHT FIXTURE MAX     MAXIMUM MEMB MEMBRANE MECH  MECHANICAL MTL       METAL MIN     MINIMUM (N)     NEW NIC     NOT IN CONTRACT OC     ON CENTER OD     OUTSIDE DIAMETER P.C.     PROPERTY CORNER P.L.     PROPERTY LINE PLT     PLATE PLAS     PLASTER PLWD     PLYWOOD R     RISERS RD     ROOF DRAIN R.O.     ROUGH OPENING RAD     RADIUS RDL     ROOF DRAIN LEADER REC     RECESSED REINF     REINFORCED REQ'D     REQUIRED RES     RESISTANT RESIL     RESILIENT RET     RETAINING REV.     REVERSE RM     ROOM S.S.     STAINLESS STEEL SV     SHEET VINYL SCHED     SCHEDULE SECT     SECTION SAM     SELF ADHERING MEMBRANE SFR     SINGLE FAMILY RESIDENCE SHT     SHEET SIM     SIMILAR SPEC     SQUARE STD     STANDARD STL     STEEL STRUCT     STRUCTURAL SUSP     SUSPENDED T     TREADS T&B     TOP AND BOTTOM T&G     TONGUE AND GROOVE T.O.     TOP OF T.O.C.     TOP OF CONCRETE TOP     TOPPING TELE     TELEPHONE TEMP     TEMPERED T.S.     TUBE STEEL TYP     TYPICAL UNO     UNLESS NOTED OTHERWISE URM     UNREINFORCED MASONRY VCT     VINYL COMPOSITION TILE W/          WITH WC     WATER CLOSET WF     WIDE FLANGE WP     WATERPROOF WD     WOOD WRB     WEATHER RESISTANT BARRIER ±     PLUS OR MINUS #     NUMBER - ANY EXISTING FIRE SPRINKLER OR FIRE ALARM SYSTEMS MUST SUBMIT FOR SEPARATE PLAN REVIEW. - FIRE SPRINKLERS SHALL BE UNDER SEPARATE PLAN CHECK PERMIT. - PROPERTY ADDRESS(S) MUST BE PERMANENTLY AFFIXED TO BUILDING IN ACCORDANCE WITH MBFC 505.1 PRIOR TO FINAL FIRE INSPECTION. [MBMC 3.16.20]. - AUTOMATIC COMMERCIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN THE BUILDING AND IN OTHER AREAS AS REQUIRED BY THE FIRE CODE OFFICIAL. - AUTOMATIC COMMERCIAL FIRE SPRINKLERS SHALL COMPLY WITH THE HERMOSA BEACH FIRE DEPARTMENT MINIMUM REQUIREMENTS FOR NFPA 13D FIRE SPRINKLER SYSTEMS. - HORN/STROBE ALARM DEVICES SHALL BE PLACED ON THE ADDRESS SIDE OF THE BUILDING UNLESS OTHERWISE SPECIFIED BY FIRE DEPARTMENT PERSONNEL. - ALL WATER PIPES TO SINKS AND LAUNDRY FACILITIES SHALL BE INSTALLED WITH SOUND DEADENING MATERIALS TO PREVENT THE TRANSFER OF NOISE. - ALL VOIDS AROUND PIPES SHALL BE PACKED WITH ROCK WOOL OR EQUIVALENT SOUND-DEADENING MATERIALS TO PREVENT THE TRANSFER OF NOISE. - NO PLUMBING VENTS OR SIMILAR EQUIPMENT SHALL BE PLACED BACK TO BACK BETWEEN SEPARATE DWELLING UNITS. • FIRE SPRINKLERS AND ALARMS A) DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN REVIEW. THE ENGINEER OF RECORD FOR THE BUILDING PROJECT SHALL PROVIDE A NOTE ON THE DEFERRED PLANS OR A SHOP DRAWING APPROVAL STAMP STATING THAT THE PLANS ARE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDINGS. (CBC 106.3.4.2) AN AUTOMATIC COMMERCIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN THE BUILDING AND IN OTHER AREAS AS REQUIRED BY THE FIRE CODE OFFICIAL. AUTOMATIC COMMERCIAL FIRE SPRINKLERS SHALL COMPLY WITH THE HERMOSA BEACH FIRE DEPARTMENT MINIMUM REQUIREMENTS FOR NFPA 13D FIRE SPRINKLER SYSTEMS. FIRE SPRINKLERS SHALL BE UNDER SEPARATE PLAN CHECK AND PERMIT [R313 CRC, 903.2.8.2 CFC AS AMENDED BY MBMC 3.16.020] Page 178 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 13 OF 136 G-102 GENERAL NOTES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 GENERAL CONSTR. HERMOSA BCH CITY BEST MANAGEMENT PRACTICES BUILDING & SAFETY PUBLIC WORKS CITY OF HERMOSA BEACH PLANNING A) CONSTRUCTION DOCUMENTS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND COMPLYING WILL ALL NOTES INCLUDED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BRING ANY AND ALL DISCREPANCIES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE CONSTRUCTION DRAWINGS, SPECIFICATIONS, ADDENDUMS, AND ANY REVISIONS ISSUED AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR WRITTEN CLARIFICATION. B) CONSTRUCTION DOCUMENTS; THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS ARE REPRESENTATIONAL OF THE FINISHED STRUCTURE AND DO NOT INDICATE THE MEANS + METHODS OF CONSTRUCTION, TECHNIQUES, SEQUENCING, OR PROCEDURES REQUIRED FOR CONSTRUCTION. C) APPROVED DRAWING SET: THE CONTRACTOR SHALL KEEP AND MAINTAIN THE CITY APPROVED RECORD SET OF DRAWINGS AT THE JOB SITE AT ALL TIMES. THE CONTRACTOR SHALL KEEP THE SET CURRENT WITH ANY APPROVED REVISIONS OR ADDENDA. D)MINIMUM STANDARDS OF WORK: IF ANY CONFLICT EXISTS IN QUALITY OF WORK OR CODE REQUIREMENTS, THE HIGHER QUALITY AND MORE RESTRICTIVE SHALL APPLY. E)NOT IN SCOPE: WORK INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS AS N.I.C. OR BY SEPARATE CONTRACTORS, IS NOT INCLUDED WITHIN THE CONTRACT OR CONSTRUCTION DOCUMENTS FOR THE PROJECT. CONTRACTOR SHALL COOPERATE FULLY WITH ALL SEPARATE CONTRACTORS CONTRACTED WITH THE OWNER. F) CODE COMPLIANCE: THE WORK SHALL BE COMPLIANT WITH ALL APPLICABLE CODE, ORDINANCES, AND REGULATIONS LISTED IN THE CONSTRUCTION DOCUMENTS AND AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. G) OSHA COMPLIANCE: WORK SHALL COMPLY WITH PERTINENT HEALTH AND SAFETY REGULATIONS FOR REQUIRED METHODS TO PROTECT ALL PERSONS INVOLVED WITH THE WORK OR VISITING THE SITE DURING THE CONSTRUCTION PERIOD. H) SITE MEASUREMENTS: CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALLDIMENSIONS IN THE FIELD PRIOR TO STARTING ANY WORK. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THE DRAWINGS TO THE ARCHITECT PRIOR TO CONTINUING WORK. I) DIMENSIONS: THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY CONFLICTING DIMENSIONS BETWEEN ARCHITECTURAL + ENGINEERING DRAWINGS. THE CONTRACTOR SHALL NOT SCALE ANY DIMENSIONS OFF OF THE DRAWINGS. J) DETAILS: DETAILS PROVIDED WITHIN THE CONSTRUCTION DOCUMENTS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED PER FIELD CONDITIONS. CONTRACTOR TO NOTIFY ARCHITECT OF SUCH REVISIONS. K) SUBSTITUTIONS: NO SUBSTITUTIONS ARE ALLOWED UNLESS SPECIFICATIONS ARE SUBMITTED TO AND APPROVED BY THE OWNER AND ARCHITECT. L)CONTRACT DEVIATIONS: ANY VALUE ENGINEERING OR SUBSTITUTION OF REQUIREMENTS NOTED IN THE CONTRACT DOCUMENTS TAKEN WITHOUT WRITTEN CONSENT FROM THE ARCHITECT,SHALL RELEASE THE ARCHITECT FROM ANY AND ALL LIABILITY FOR THAT PORTION OF THE PROJECT. M) COORDINATION WITH CONTRACTORS/CONSULTANTS: THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH ALL OTHER TRADES, CONSULTANTS, AND SUB-CONTRACTORS WORKING ON THE PROJECT WHETHER UNDER CONTRACT OF THE CONTRACTOR OR OWNER. N) DIMENSIONS: ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DIMENSIONAL CONFLICTS WITHIN THE CONTRACT DOCUMENTS. O) SITE ACCESS: THE CONTRACTOR SHALL GIVE THE CLIENT, ARCHITECT, CONSULTANTS, AND INSPECTORS ACCESS TO THE JOB SITE DURING NORMAL BUSINESS HOURS FOR THE DURATION OF CONSTRUCTION. P) SITE OBSERVATION: ANY SITE OBSERVATION BY THE ARCHITECT DURING CONSTRUCTION IS FOR THE SOLE PURPOSE OF REVIEWING THE WORK FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT IS NOT RESPONSIBLE FOR INSPECTION OF PROTECTIVE MEASURE ORTHE CONSTRUCTION PROCEDURES OR FOR GUARANTEEING THE CONTRACTOR'S WORK. Q) DAMAGES: CONTRACTOR TO PROTECT ALL AREAS ADJACENT TO CONSTRUCTION AREAS FROM DAMAGE CAUSED BY MOVEMENT OF MATERIALS OR DUST. ALL DAMAGE INCURRED SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. R) SITE EGRESS: ALL EXIT DOORS, EXIT ACCESS, AND CORRIDORS SHALL REMAIN UNOBSTRUCTED AT ALL TIMES. MATERIALS SHALL NOT BE STORED OR STOCKPILED IN A MANNER WHICH BLOCKS EGRESS OF CREATES AN UNSAFE CONDITION. S) SITE CLEANLINESS: CONTRACTOR SHALL MAINTAIN A CLEAN JOB SITE FREE OF TRASK AND DEBRIS. WORK AREAS SHALL BE MAINTAINED IN A BROOM CLEAN CONDITIONS AT THE END OF EACH WORK DAY/SHIFT. T) STORING + DISPOSING OF MATERIALS: ALL CONSTRUCTION WORK INCLUDING MATERIALS OF CONSTRUCTION AND PROCEDURES FOR STORING, DISPOSING OF, AND INSTALLING MATERIALS SHALL CONFORM TO THE LATEST ADOPTED CODES OF THE LOCAL AUTHORITY HAVING JURISDICTION. U) ROUGH UTILITIES: CONTRACTOR SHALL FURNISH AND INSTALL ROUGH PLUMBING AND ELECTRICAL AND FINAL HOOK-UP FOR ALL SPECIFIED FIXTURES, APPLIANCES, AND EQUIPMENT. V) ACCESS PANELS: CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL ACCESS PANELS REQUIRED IN CEILINGS, WALLS, OR FLOORS FOR ACCESS TO ALL EQUIPMENT AS REQUIRED PER APPLICABLE CODE. W) EQUIPMENT STANDARDS: ALL ELECTRICAL, MECHANICAL AND PLUMPING FIXTURES/ EQUIPMENT SHOULD BE LISTED AND LABELED BY AN APPROVED TESTING AGENCY. X) SUBMITTALS: THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT SUBMITTALS FOR REVIEW DURING CONSTRUCTION PRIOR TO COMMENCEMENT OF SPECIFIC WORK. SUBMITTALS INCLUDE, BUT ARE NOT LIMITED TO, MATERIAL DATA SHEETS, PHYSICAL SAMPLES, AND SHOP DRAWINGS AND SHALL BE SUPPLIED TO THE ARCHITECT AS REQUESTED. A) BACK FLOW DEVICES: ALL LANDSCAPE IRRIGATION BACK FLOW DEVICES MUST MEET CURRENT CITY REQUIREMENTS FOR PROPER INSTALLATION. B) WASTE REMOVAL: NO DISCHARGE OF CONSTRUCTION WASTEWATER, BUILDING MATERIALS, DEBRIS, OR SEDIMENT FROM THE SITE IS PERMITTED. NO REFUSE OF ANY KIND GENERATED ON A CONSTRUCTION SITE MAY BE DEPOSITED IN RESIDENTIAL, COMMERCIAL, OR PUBLIC REFUSE CONTAINERS AT ANY TIME. THE UTILIZATION OF WEEKLY REFUSE COLLECTION SERVICE BY THE CITY'S HAULER FOR ANY REFUSE GENERATED AT THE CONSTRUCTION SITE IS STRICTLY PROHIBITED. FULL DOCUMENTATION OF ALL MATERIALS/TRASK LANDFILLED AND RECYCLED MUST BE SUBMITTED TO THE PERMITS DIVISION IN COMPLIANCE OF THE CITY'S CONSTRUCTION AND DEMOLITION RECYCLING ORDINANCE. C) SEWER CLEANOUT: A PROPERTY LINE CLEANOUT MUST BE INSTALLED ON A 6 DEGREE SANITARY SEWER LATERAL. IF THERE IS NO 6 DEGREE LATERAL, THEN A NEW ONE MUST BE INSTALLED WITHIN THE PROPERTY LINES. SEE LOCAL PUBLIC WORKS DEPARTMENT FOR TYPICALCONSTRUCTION DETAILS. D) BACKWATER VALVE: A BACKWATER VALVE IS REQUIRED ON THE SANITARY SEWER LATERAL IF THE DISCHARGES FROM FIXTURES WITH FLOOD LEVEL RIMS ARE LOCATED BELOW THE NEXT UPSTREAM MANHOLE COVER OF THE PUBLIC SEWER. SEE LOCAL PUBLIC WORKS DEPARTMENT FOR TYPICAL CONSTRUCTION DETAILS. E) EXISTING SEWER LATERAL: IF AN EXISTING SEWER LATERAL IS USED, IT MUST BE TELEVISED TO VERIFY ITS STRUCTURAL INTEGRITY. THE TAPE MUST BE MADE AVAILABLE FOR REVIEW BY THE PUBLIC WORKS DEPARTMENT. THE LOCAL PUBLIC WORKS DEPARTMENT WILL REVIEW THE TAPE AND DETERMINE AT THAT TIME IF THE SANITARY LATERAL NEEDS REPAIRING, REPLACING, OR THAT IT IS STRUCTURALLY SOUND AND CAN BE USED IN ITS PRESENT CONDITION. F) UNUSED LATERALS: ANY UNUSED WATER OR SANITARY SEWER LATERALS MUST BE ABANDONED AT THE CITY MAIN. G) PROTECTION OF PROPERTY: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECTALL THE STREET SIGNS, STREET LAMPS/LIGHTS, PARKING METERS, AND/OR TREES AROUND THE PROPERTY. IF THEY ARE DAMAGED, LOST OR REMOVED, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE THEM AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR IS ALSO RESPONSIBLE FOR ANY STREET MARKINGS THAT ARE DAMAGED OR REMOVED BY THE CONTRACTOR'S OPERATIONS. CONTACT THE PUBLIC WORKS INSPECTOR FOR SIGN SPECIFICATION AND SUPPLIERS. H) WATER METERS: WATER METERS MUST REMAIN ACCESSIBLE FOR METER READERS DURING CONSTRUCTION. WATER METERS SHALL BE PLACED NEAR THE PROPERTY LINE AND OUT OF THE DRIVEWAY APPROACH WHENEVER POSSIBLE. THE WATER METER BOX MUST BE PURCHASED FROM THE CITY AND MUST HAVE A TRAFFIC RATED LID IF THE BOX IS LOCATED IN THE DRIVEWAY. I) PARKWAY TREES: IF ANY PARKWAY TREES ARE REMOVED, THEY MUST BE REPLACED WITH TREES SELECTED FROM THE CITY'S APPROVED PARKWAY TREE LIST AND PLANTED IN ROOT BARRIER BOXES. J) BEST MANAGEMENT PRACTICES: EROSION AND SEDIMENT CONTROL DEVICES BMP'S (BESTMANAGEMENT PRACTICES) MUST BE IMPLEMENTED AROUND THE CONSTRUCTION SITE TO PREVENT DISCHARGE TO THE STREET AND ADJACENT PROPERTIES. CONTROL MEASURES MUST ALSO BE TAKEN TO PREVENT STREET SURFACE WATER FROM ENTERING THE SITE. K) DRAIN LINES: ALL DRAIN LINES INSTALLED WITHIN THE STREET RIGHT-OF-WAY MUST BE CONSTRUCTED OF DUCTILE IRON PIPE. DRAINS MUST BE SHOWN ON PLANS. L) RUNOFF DISCHARGE: ALL RUNOFF WATER FROM THE ROOF, SIDE YARDS, AND PATIOS MUST DISCHARGE ONTO STREET. A) TYPE OF CONSTRUCTION: ALL PERSONS WORKING ON THE SITE SHOULD OBTAIN, READ, AND UNDERSTAND THE BEST MANAGEMENT PRACTICES PAMPHLET FOR THE TYPE(S) OF CONSTRUCTION BEING DONE. B) SITE WASH-OFF: STOCKPILES OF SOILS, DEMOLITION DEBRIS, CEMENT, SAND, TOPSOIL, ETC.,MUST BE COVERED WITH WATERPROOF MATERIALS OR BERMED TO PREVENT BEING WASHED OFF SITE. C) LIQUID MATERIALS: FUELS, OILS, PAINTS, SOLVENTS, AND OTHER LIQUID MATERIALS MUST NOT BE WASHED INTO THE STREET. D) CONCRETE WASTE: WASTE CONCRETE MUST NOT BE WASHED INTO STREET, STORM DRAIN CATCH BASINS, OR PUBLIC RIGHT-OF-WAY. ALL DUST AND SLURRY FROM CONCRETE CUTTING MUST BE REMOVED USING WET-DRY VACUUM OR EQUIVALENT. E) SOLID WASTE: TRASH AND OTHER CONSTRUCTION SOLID WASTE MUST BE PLACED IN A COVERED TRASH RECEPTACLE. F) ERODED SOIL: ERODED SOIL FROM DISTURBED SLOPED MUST BE CONTAINED USING BERMS, SILT FENCES, SETTING BASINS, OR GOOD EROSION MANAGEMENT PRACTICES SUCH AS RESEEDING. G) WASH WATER: WASH WATER FROM CLEANING CONSTRUCTION VEHICLES AND EQUIPMENTMUST BE KEPT ON-SITE WITHIN A CONTAINMENT AREA. H) CONCRETE DRIVEWAY: CONSTRUCT NEW COMMERCIAL CONCRETE DRIVEWAY TYPE WHERE NOTED ON SITE PLAN. NEW CONCRETE SHALL BE CLASS 520-C-2500. I) PREFABRICATED BEAMS: SUBMIT CERTIFICATE OF PREFABRICATED BEAMS TO BUILDING INSPECTOR PRIOR TO INSTALLATION OF SUCH BEAMS. X) A) CONSTRUCTION TIMES: CONTRACTOR SHALL CONFIRM HOURS FOR CONSTRUCTION ACTIVITY WITH LOCAL AGENCY AND ONLY OPERATE DURING APPROVED HOURS. NO CONSTRUCTION IS PERMITTED OUTSIDE OF THOSE HOURS. B) CONSTRUCTION SIGNS: CONTRACTOR SHALL CONFIRM REQUIREMENTS FOR CONSTRUCTION SITE SIGNAGE WITH LOCAL AGENCY. CONTRACTOR SHALL PROVIDE AND MAINTAIN REQUIRED SIGNAGE AT PROJECT SITE AT ALL TIMES. C) CONSTRUCTION FENCE: CONTRACTOR SHALL PROVIDE CONSTRUCTION FENCE PER CBC 3303 AT PUBLIC RIGHT-OF-WAY FOR PEDESTRIAN PROTECTION IF ANY WORK IS TO BE PERFORMED ON ANY BUILDING OR STRUCTURE ADJACENT TO PUBLIC RIGHT-OF-WAY. D) DEMOLITION: NO DEMOLITION SHALL COMMENCE WITHOUT A VALID DEMOLITION PERMIT. WORK COMMENCES WITHOUT A VALID PERMIT MAY BE SUBJECT TO A SPECIAL INVESTIGATION BEFORE A PERMIT MAY BE ISSUED. E) GRADING PERMIT: A GRADING PERMIT IS REQUIRED WHEN GRADING OR EXCAVATION INVOLVES A CUT OR FILL DEPTH OF 3' OR MORE AND/OR 200 CUBIC YARDS. SUBMIT GRADING PLAN AND SOILS REPORT TO THE BUILDING DEVISION FOR REVIEW AND APPROVAL. DUST SHALL BE CONTROLLED CONTINUOUSLY BY WATERING OR BY OTHER APPROVED MEANS OF EXCAVATING. CONTRACTOR SHALL NOTIFY THE UNDERGROUND SERVICE ALERT (1-800-422-4133) PRIOR TO ANY EXCAVATION. F) SHORING PERMIT: A SHORING PERMIT IS REQUIRED FOR ANY VERTICAL CUT OR FILL THAT IS EQUAL TO OR GREATER THAN 5' IN HEIGHT. ENGINEERED SHORING PLANS AND CALCULATIONS AND SOILS REPORT MUST BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW AND APPROVAL PER SECTION 3301.2 OF THE CBC. THE HOLDER OF A SHORING PERMIT SHALL NOTIFY IN WRITING ALL THE OWNER'S OF ADJOINING PROPERTIES NOT LESS THAN 10 DAYS BEFORE SUCH EXCAVATION IS TO COMMENCE. AN OSHA PERMIT IS ALSO REQUIRED - A COPY OF WHICH SHALL BE SUBMITTED TO THE BUILDING DEVISION. SHORING CONTRACTOR SHALL NOTIFY THE UNDERGROUND SERVICE ALERT (1-800-422-4133) PRIOR TO ANY EXCAVATION. G) SANDBLASTING: THE SANDBLASTING MUST BE WET SANDBLASTING AND ALL THE PRECAUTIONARY MEASURES MUST BE TAKEN BY THE CONTRACTOR TO PROTECT LIFE AND PROPERTY OF NEIGHBORS, RESIDENTS AND THE PUBLIC. ADJACENT PROPERTY OWNERS MUST BE NOTIFIED AT LEAST (2) DAYS PRIOR TO SANDBLASTING. H) SITE DRAINAGE: PROVIDE ROOF GUTTERS AND DOWNSPOUTS OR CONCRETE PAVEMENT/SWALE ON GROUND TO DIVERT OR CARRY SURFACE WATER AWAY FROM BUILDING TO CATCH BASIN AND DRAIN PIPES THROUGH CURB TO STREET AND STORM DRAIN SYSTEM. I) STAIRWAYS: WIDTH OF STAIRWAYS SHALL BE 36" MIN CLEAR TAKEN FROM FACE OF FINISH. GUARDRAILS OR HANDRAIL PICKETS SHALL HAVE A MAXIMUM 4" SPACING BETWEEN PICKETS. J) GARAGE DOOR: GARAGE DOOR OPENING INCLUDING HARDWARE SHALL BE 7' MINIMUM AND 18' WIDE. GARAGE DOOR SPRINGS AND OPENERS SHALL BE STATE APPROVEDAND WITH MANUFACTURER'S LABEL. DOOR LEADING FROM GARAGE TO DWELLING UNIT SHALL BE A 20 MINUTE FIRE RATED, 1-3/8" SOLID WOOD, SELF-CLOSING, AND TIGHT FITTING DOOR. K) NAILS: ONLY COMMON NAILS SHALL BE PERMITTED FOR THE REQUIRED NAILINGS ON VERTICAL AND HORIZONTAL DIAPHRAGMS SUCH AS SHEAR WALLS AND ROOF/FLOOR SHEATHINGS RESPECTIVELY. L) REBAR WELDING: WELDING OF REBAR SHALL COMPLY WITH CBC, STANDARD 19-1. CONTRACTOR TO SUBMIT WELDING PROCEDURES AND QUALIFICATION OF DEPUTY/SPECIAL INSPECTIONS IN ACCORDANCE WITH SPECIAL INSPECTION PROGRAM TO THE BUILDING DIVISION FOR APPROVAL PRIOR TO ANY WELDING WORK. M) FUTURE UTILITIES: CONTRACTOR TO PROVIDE UNDERGROUND CONDUIT FOR FUTURE ELECTRICAL LINES AT THE PRONT PROPERTY LINES. CONTRACTOR TO COORDINATE WITH INSPECTOR FOR ADDITIONAL COMMENTS. A) SEPARATE PERMITS: SEPARATE PERMITS AND PLANS ARE REQUIRED FOR SPAS, POOLS, SOLAR PANELS, DEMOLITION, AND SEWER CAP OF EXISTING BUILDINGS. B) VERTICAL PROJECTIONS IN SETBACKS: FENCE, WALL, AND HANDRAIL HEIGHTS AS MEASURED FROM THE LOWEST FINISHED GRADE ADJACENT TO EACH SECTION OF THESE STRUCTURES, MAY BE A MAXIMUM OF 42" IN THE FRONT YARD SETBACK, AND 72" AT ALL OTHER LOCATIONS ON SITE UNLESS LOCATED IN A LINE-OF-SIGHT OR DRIVEWAY VISIBILITY AREA. CONTRACTOR TO CONFIRM HEIGHT LIMITATIONS WITH THE LOGAL PLANNING DEPARTMENT C) ADDRESS NUMBERS: BUILDING ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND AND BE 4" MINIMUM HIGH WITH A MINIMUM STROKE WIDTH OF 0.5" PER CBC R319.9. D) ON SITE PARKING: PARKING IS NOT PERMITTED IN REQUIRED YARDS OR OPEN SPACE EXCEPT FOR A 20' WIDE FRONT YARD DRIVEWAY. E) FUTURE SOLAR WATER HEATING: A "CAPPED TEE" FITTING MUST BE INSTALLED OVER THE COLD WATER SUPPLY LINE ABOVE THE WATER HEATER FOR FUTURE SOLAR WATER HEATING. PIT RELIEF VALVE SHALL TERMINATE OUTSIDE THE BUILDING. F) UNDERGROUND CONDUIT: ROUTE UNDERGROUND CONDUIT TO POWER POLE PER PUBLIC WORKS STANDARD DETAILS. STUB OUT FOR PROPERTY LINE FOR FUTURE UNDER-GROUNDING OF UTILITIES WHEN APPLICABLE. G) MECHANICAL EQUIPMENT SCREENING: PROVIDE VISUAL SCREENING FOR PROPOSED MECHANICAL EQUIPMENT AND UTILITY METERS. TOP NEED NOT TO BE SCREENED IF LOCATED ON INTERIOR SIDE OF DWELLING. H) METER CLEARANCE: GAS AND ELECTRIC METERS MUST CLEAR PROPERTY LINES BY 3'-0". I) CESSPOOL LOCATIONS: IF THERE IS AN EXISTING CESSPOOL ON SITE, IT MUST BE LOCATED BY CITY PERSONNEL BEFORE DEMOLITION OR BUILDING PERMITS CAN BE ISSUED. CONTRACTOR TO VERIFY EXISTENCE OF CESSPOOL WITH LOCAL AUTHORITY HAVING JURISDICTION PRIOR TOPROCEEDING WITH DEMOLITION OR CONSTRUCTION ACTIVITIES. Page 179 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 14 OF 136 G-201 SITE PHOTOS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 WEST VIEW NORTHEAST VIEW NORTHWEST VIEW SOUTHEAST VIEW SOUTHWEST VIEW Page 180 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 15 OF 136 G-202 CURRENT VS PROPOSED SQ FT ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 4,134 sq ft 3,590 sq ft 906 sq ft 159 sq ft OPENTO BELOW OPEN TOBELOW OPEN TO BELOW 887 sq ft 4,345 sq ftOPENTO BELOW 817 sq ft 349 sq ft 60 sq ft 48 sq ft 89 sq ft 226 sq ft123456789101112131415161718UP18 RISERS (6 23/32") 4'-9 1/2" 2,840 sq ft 1,973 sq ft 684 sq ft RETAIL 104RETAIL105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM106 RSTRM 103 STAIR 02 114 STAIR 01121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE111 RETAIL101 HALL 102 ELEV RM121 ELECTRIC RM 120 TRANSFORMER 121 OPENTO ABOVE 1234567 8 UP 20 RISERS (7") 93 sq ft RESTRM108 ACC. RSTRM109 TRASH RM 119 499 sq ft DN 2,268 sq ft OPEN TOBELOW OPEN TOBELOW OPEN TOBELOW DEACTIVATED SPACE (NOT ACCESSIBLE) OPEN TOABOVE OPEN TOBELOW OFFICE 207 OFFICE206 OFFICE205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02 209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 DN 12345 67UP 12 RISERS (6 1/2")123456789101112131415 16UP 16 RISERS (6 25/32") 227 sq ft OPEN TO ABOVE 3,459 sq ft SK-1 SK-2 SK-3 F DW F 45" CLROPENTO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPENTO ABOVE ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE 301 OFFICE315 OFFICE 308 OFFICE 310 COURTYARD 318 GARDEN316 CONFERENCE RM314 OFFICE 309 OFFICE 304 RSTRM321 KITCHEN 319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM317 GARDEN 311 GARDEN320 GARDEN 323 VESTIBULE 306 STAIRWELL EXIT 325 RESTROOM CORRIDOR 324 MECH. PLATFORM302 STAIR 01 327 OPEN TO ABOVE OPEN TO ABOVE OPEN TOABOVE DN DN 195 sq ft OPEN TOABOVE OPEN TOABOVE GREEN ROOF307 GROSS SQUARE FOOTAGE EXISTING SQ FT PROPOSED SQ FT NET PROPOSED EXPANSION SQ FT FIRST FLOOR 7724 7179 -545 STORAGE 3,590 2,840 -750 RETAIL 4,134 1,973 -2,161 RETAIL STORAGE 0 817 817 OFFICE 0 684 684 UTILITIES/STAIRS 0 639 639 ADDITIONAL SPACE 0 226 226 SECOND FLOOR 6297 2994 -3303 STORAGE 4,345 2,268 -2,077 RETAIL STORAGE 1,065 0 -1065 OFFICE 887 499 -388 ADDITIONAL SPACE 0 227 227 THIRD FLOOR 0 3654 3654 OFFICE 0 3,459 3459 STAIRS 0 195 195 TOTAL 14021 13827 -194 F.A.R. (8180 SF SITE)1.71 1.69 1 9 9 NOT TO SCALE1EXISTING FIRST FLOOR NOT TO SCALE2EXISTING SECOND FLOOR NOT TO SCALE3PROPOSED FIRST FLOOR NOT TO SCALE4PROPOSED SECOND FLOOR NOT TO SCALE5PROPOSED THIRD FLOOR NOT TO SCALE6GROSS SQUARE FOOTAGE Page 181 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 16 OF 136 G-203 CODE REPORT ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 ZONING SUMMARY APPLICABLE CODE: HERMOSA BEACH MUNICIPAL CODE (HBMC) ZONING DESIGNATION: COMMUNITY COMMERCIAL - CC (GENERAL PLAN) GENERAL COMMERCIAL - C2 (HBMC) CHARACTER AREA: DOWNTOWN CENTER NEIGHBORING ZONING: LOT TO NORTH = C2 (GENERAL COMMERCIAL) LOT TO EAST = C2 (GENERAL COMMERCIAL) LOT TO SOUTH = R2/C2 (TWO-FAMILY RESIDENTIAL & GENERAL COMMERCIAL) LOT TO WEST = R2 (TWO-FAMILY RESIDENTIAL) PARCEL NUMBER: 4187003028 SITE AREA: 8180 SQFT BUILDING AREA PROPOSED:14,018 SQFT 1ST FLOOR PROPOSED: 7,531 SQFT 2ND FLOOR PROPOSED: 2,833 SQFT 3RD FLOOR PROPOSED: 3,654 SQFT ZONING ANALYSIS HBMC 17.26.050 STANDARDS AND LIMITATIONS FRONT: N/A PROPOSED: NO CHANGE TO EXISTING REAR: N/A (EXISTING BUILDING PER 17.26.050.H.3) PROPOSED: NO CHANGE TO EXISTING SIDE: N/A (EXISTING BUILDING PER 17.26.050.H.3) PROPOSED: NO CHANGE TO EXISTING GENERAL PLAN INTENSITY RANGE (FAR) MAX FAR: 1.25 FOR COMMUNITY COMMERCIAL 1.25 * 8,180 SF = 10,225 SF MIN FAR: .5 FOR COMMUNITY COMMERCIAL .5 * 8,180 SF = 4,090 SFPROPOSED: EXEMPTION: THE PROJECT BUILDING IS EXISTING AND FALLS OUTSIDE FAR MAX; SEE SHEET G201 HBMC 17.26.050 STANDARDS AND LIMITATIONS THE DESIGN OF ALL SIGNS SHALL BE IN CONFORMANCE WITH THE DESIGN STANDARDS REFERENCED IN HBMC 17.50.130. HBMC 17.26.050(E) BUILDING HEIGHT MAX BUILDING HEIGHT: 30'-0" EXISTING: 16.71' MIN - 23.82' MAX PROPOSED: 28.81' MIN - 29.97' MAX (SEE ROOF PLAN SHEET FOR CALCS) HBMC 17.26.050(F,G,H) SETBACKS FRONT YARD SETBACK: N/A PROPOSED: EXISTING BUILDING FOOTPRINT ALLEY SETBACK: SHALL CONFORM W/ SECTION 17.44.130 PROPOSED: EXISTING BUILDING FOOTPRINT REAR YARD SETBACK: 5' SETBACK PROPOSED: EXISTING BUILDING FOOTPRINT EXISTING: ZERO LOT-LINE CONDITIONS AT NORTH, EAST, & SOUTH; WEST PROP LINE SETBACK OF 2.8' HBMC 17.46.010 HEIGHT OF ROOF STRUCTURES A. ELEMENTS LISTED IN 17.46.010.A MAY BE CONSTRUCTED ABOVE THE HEIGHT LIMIT, PROVIDED THEY DO NOT EXCEED THE HEIGHT LIMIT BY MORE THAN 8 FEET AND COVER NO MORE THAN 5 PERCENT OF THE TOTAL ROOF AREA. HBMC 17.44.015 OFF-STREET PARKING (APPLICABILITY) D.1 ADDITIONS LESS THAN 10 PERCENT OR 500 SF. NO ADDITIONAL PARKING IS REQUIRED FOR ALTERATIONS TO EXISTING BUILDINGS THAT DO NOT CHANGE THE BUILDING SQUARE FOOTAGE ON SITE BY MORE THAN 10 PERCENT OR 500 SF, WHICHEVER IS GREATER, PROVIDED THE USE IS OTHER THAN A LATE NIGHT ALCOHOL ESTABLISHMENT PARKING PROPOSED: N/A - EXISTING SITE WILL REMAIN WITH ZERO PARKING SPACES HBMC 17.46.220 SOLAR ENERGY SYSTEMS-HEIGHT LIMIT EXCEPTION AND STREAMLINED PERMITTING C1. SOLAR COLLECTORS AND SOLAR ENERGY SYSTEMS MAY EXCEED THE HEIGHT LIMITS MANDATED BY THIS CODE TO THE MINIMUM EXTENT NECESSARY FOR THEIR SAFE AND EFFICIENT OPERATION IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE AND OTHER APPLICABLE PROVISIONS OF STATE LAW. HBMC 12.36.060 PERMIT REQUIREMENT FOR TREE REMOVAL E. A PERMIT TO REMOVE A TREE SHALL BE CONDITIONED ON REPLACEMENT OF THE TREE, EITHER ON SITE OR ELSEWHERE AS DESCRIBED BY THE CITY. ON-SITE REPLACEMENT IS REQUIRED UNLESS ON-SITE REPLACEMENT IS INFEASIBLE. REMOVED TREES SHALL BE REPLACED AT A MIN 2:1 RATIO WITH A TREE FROM THE CITY'S OFFICIAL LIST OF APPROVED PARKWAY TREES. TREES REMOVED: 1 TREE TREES PROPOSED: 4TREES 123456789101112131415161718 UP18 RISERS (6 23/32") 29'-0" 51'-5" EXIT 8 RETAIL104RETAIL 105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM106 RSTRM103 STAIR 02114 STAIR 01 121 FIRE (ASR) RM118 RESTRM CORRIDOR107 ELEVATOR 02 OFFICE111 RETAIL101 HALL 102 ELEV RM 121 ELECTRIC RM 120 TRANSFORMER1211234567 8 UP 20 RISERS (7") RESTRM 108 ACC. RSTRM109 TRASH RM119 DN 81'-4 "OFFICE207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 DN 123456 7UP 12 RISERS (6 1/2")12345678910111213141516 UP 16 RISERS (6 25/32") SK-1 SK-2 SK-3 F DW F 45" CLR1 0 3'- 5 " ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM 314 OFFICE 309 OFFICE304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM317 GARDEN311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN GREEN ROOF 307 BUILDING CODE SUMMARY APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 HERMOSA BEACH MUNICIPAL CODE (HBMC) OCCUPANCY CLASSIFICATION (302): BUSINESS: B MERCANTILE: M STORAGE: S-1 CONSTRUCTION TYPE FOR EXISTING AND NEW PORTIONS OF PROJECT (601): TYPE: VB - 0 HOUR FIRE SPRINKLER REQUIREMENTS (903): PER 903.2.7 - M OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM PER 903.2.9 - S1 OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM REQUIRED: FIRE SPRINKLER NOT REQUIRED PROPOSED: NFPA 13 SPRINKLER PROVIDED GENERAL CODE CHAPTER 5: BUILDING HEIGHT AND AREA 504 - 506 TABLE: ALLOWABLE BUILDING HEIGHTS, STORIES ABOVE GRADE PLAN, AND AREAS: TYPE VB CONSTRUCTION / SPRINKLERED / B OCCUPANCY: 60' H / 3-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / M OCCUPANCY: 60' H / 2-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / S-1 OCCUPANCY: 60' H / 2-STORIES / 27,000 SF EXISTING HEIGHT / STORIES / AREA: 23.32' MIN - 24.48' MAX / 2 STORIES / 13,943 SF PROPOSED HEIGHT / STORIES / AREA: 28.81' MIN - 29.97' MAX / 3 STORIES / 13,885 SF CHAPTER 6: TYPES OF CONSTRUCTION 601 TABLE: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS): PRIMARY STRUCTURAL FRAME 0 HR EXTERIOR BEARING WALLS 0 HR INTERIOR BEARING WALLS 0 HR INTERIOR NONBEARING WALLS AND PARTITIONS 0 HR FLOOR CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES 705.2: PROJECTIONS PROJECTS SHALL NOT EXTEND ANY CLOSER TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE THAN SHOWN IN TABLE 705.2 705.2.2: TYPE III, IV, OR V CONSTRUCTION PROJECTIONS FROM WALLS OF TYPE III, IV, OR V CONSTRUCTION SHALL BE OF ANY APPROVED MATERIAL 705.5 FIRE-RESISTANCE RATINGSEXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION 601 AND 602. THE REQUIRED FIRE- RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF GREATER THAN 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF LESS THAN OR EQUAL TO 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. TABLE: FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (HOURS): GROUP B / TYPE VB LESS THAN 5'-0" 0 HR 5'-0" TO LESS THAN 10'-0" 0 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR GROUP M & S-1 / TYPE VBLESS THAN 5'-0" 2 HR 5'-0" TO LESS THAN 10'-0" 1 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR EXISTING SEPARATION DISTANCE (SEE SITE PLAN A101) 705.8: OPENINGS OPENINGS IN EXTERIOR WALLS SHALL COMPLY WITH SECTION 705.8.1 THROUGH 705.8.6 705.8.1: ALLOWABLE AREA OF OPENINGS EXCEPTION 2: BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR NONBEARING WALLS AND EXTERIOR PRIMARY STRUCTURAL FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED SHALL BE PERMITTED TO HAVE UNLIMITED UNPROTECTED OPENINGS. 705.8.5: VERTICAL SEPARATION OF OPENINGS EXCEPTION 2: THIS SECTION SHALL NOT APPLY TO BUILDINGS THAT ARE THREE STORIES OR LESS ABOVE GRADE PLAN EXCEPTION 3: THIS SECTION SHALL NOT APPLY TO BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEMIN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.1.2 705.11: PARAPETS PARAPETS SHALL BE PROVIDED ON EXTERIOR WALLS OF BUILDINGS EXCEPTION: A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF THE FOLLOWING CONDITIONS ARE MET - THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 705.5 BECAUSE OF FIRE SEPARATION DISTANCE 708.6: OPENINGS (EXTERIOR WALL) OPENINGS IN A FIRE PARTITIONS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716 708.7: PENETRATIONS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION SHALL COMPLY WITH SECTION 714 708.9: DUCTS AND AIR TRANSFER OPENINGS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION BY DUCTS AND AIR TRANSFER OPENINGS SHALL COMPLY WITH SECTION 717 711.2.3: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) THE SUPPORTING CONSTRUCTION SHALL BE PROTECTED TO AFFORD THE REQUIRED FIRE-RESISTANCE RATING OF THE HORIZONTAL ASSEMBLY SUPPORTED EXCEPTION: IN BUILDINGS OF TYPE IIB, IIIB, OR VB CONSTRUCTION, THE CONSTRUCTION SUPPORTING THE HORIZONTAL ASSEMBLY IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED AT THE FOLLOWING: - HORIZONTAL ASSEMBLIES AT THE SEPARATIONS OF INCIDENTAL USES AS SPECIFIED BY TABLE 509.1 PROVIDED THAT THE REQUIRED FIRE-RESISTANCE RATING DOES NOT EXCEED 1 HOUR. - HORIZONTAL ASSEMBLIES AT SMOKE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 709 711.2.4.1: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) WHERE THE HORIZONTAL ASSEMBLY SEPARATES MIXED OCCUPANCIES, THE ASSEMBLY SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN THAT REQUIRED BY SECTION 508.4 BASED ONT HE OCCUPANCIES BEING SEPARATED ALLOWABLE: NO SEPARATION REQUIREMENT REQUIRED 711.3: NONFIRE-RESISTANCE-RATED FLOOR AND ROOF ASSEMBLIES NONFIRE-RESISTANCE-RATED FOOR, FLOOR/CEILING, ROOF AND ROOF/CEILING ASSEMBLIES SHALL COMPLY WITH SECTIONS 711.3.1 AND 711.3.2 713.4: FIRE-RESISTANCE RATING (SHAFT WALLS) SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIES OR MORE, AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES. THE NUMBER OF STORIES CONNECTED BY THE SHAFT ENCLOSURE SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES. SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED BUT NOT EXCEED 2 HOURS. SHAFT ENCLOSURES SHALL MEET THE REQUIREMENTS OF SECTION 703.2.1.1 713.6: EXTERIOR WALLS (SHAFT WALLS) WHERE EXTERIOR WALLS SERVE AS A PART OF A REQUIRED SHAFT ENCLOSURE, SUCH WALLS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 705 FOR EXTERIOR WALLS AND THE FIRE-RESISTANCE-RATED ENCLOSURE REQUIREMENTS SHALL NOT APPLY. CHAPTER 9: FIRE PROTECTION SYSTEMS 906.1: PORTABLE FIRE EXTINGUISHERS EXTINGUISHERS REQUIRED PER SECTION 906.1 906.2: GENERAL REQUIREMENTS PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH THIS SECTION AND CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, CHAPTER 3. 906.3 TABLE: SIZE AND DISTRIBUTIONS LOW HAZARD OCCUPANCY MIN-RATED SINGLE EXTINGUISHER 2-A EXTINGUISHER MAX FLOOR AREA FOR UNIT 3,000 SF MAX FLOOR AREA FOR EXTINGUISHER 11,250 SF MAX DISTANCE OF TRAVEL TO EXTINGUISHER 75'-0" REQUIRED: PROVIDED: 906.5: CONSPICUOUS LOCATION PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS LOCATIONS WHERE THEY WILL HAVE READY ACCESS AND BE IMMEDIATELY AVAILABLE FOR USE. THESE LOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL, UNLESS THE FIRE CODE OFFICIAL DETERMINES THAT THE HAZARD POSED INDICATES THE NEED FOR PLACEMENT AWAY FROM NORMAL PATHS OF TRAVEL. 907: FIRE ALARM AND DETECTION SYSTEMS GROUP B, M, & S: MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT NOTIFICATION APPLIANCES WILL AUTOMATICALLY ACTIVATE THROUGHOUT THE NOTIFICATION ZONES UPON SPRINKLER WATER FLOW. 911: FIRE COMMAND CENTER NOT REQUIRED FOR S-1 OCCUPANCY WITH A SIZE LESS THAN 500,000 SF CHAPTER 10: MEANS OF EGRESS 1003.2: CEILING HEIGHT THE MEANS OF EGRESS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7'-6" ABOVE THE FINISHED FLOOR EXCEPTIONS: - SLOPED CEILINGS IN ACCORDANCE WITH SECTION 1208.2 - ALLOWABLE PROJECTIONS IN ACCORDANCE WITH SECTION 1003.3 - STAIR HEADROOM IN ACCORDANCE WITH SECTION 1011.3 - DOOR HEIGHT IN ACCORDANCE WITH SECTION 1010.1.1 - RAMP HEADROOM IN ACCORDANCE WITH SECTION 1012.5.2 - AREAS ABOVE AND BELOW MEZZANINE FLOORS IN ACCORDANCE WITH SECTION 505.2 1004.4: MULTIPLE OCCUPANCIES WHERE A BUILDING CONTAINS TWO OR MORE OCCUPANCIES, THE MEANS OF EGRESS REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY OF THAT SPACE. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYTEMS, THOSE EGRESS COMPONENTS SHALL MEET THE MORE STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED. 1004.5: AREAS WITHOUT FIXED SEATING THE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT OF AREA AS PRESCRIBED IN TABLE 1004.5 FOR AREAS WITHOUT FIXED SEATING, THE OCCUPANT LOAD SHALL BE NOT LESS THAN THAT NUMBER DETERMINED BY DIVIDING THE FLOOR AREA UNDER CONSIDERATION BY THE OCCUPANT LOAD FACTOR ASSIGNED TO THE FUNCTION OF THE SPACE AS SET FORTH IN TABLE 1004.5 WHERE AN INTENDED FUNCTION IS NOT LISTED IN TABLE 1004.5, THE BUILDING OFFICIAL SHALL ESTABLISH A FUNCTION BASED ON A LISTED FUNCTION THAT MOST NEARLY RESEMBLES THE INTENDED FUNCTION. PER TABLE 1004.5 OFFICE SPACE, (BUSINESS AREAS) B: 150 GROSS/OCCUPANT RETAIL, M: 60 GROSS/OCCUPANT RETAIL STORAGE, M: 300 GROSS/OCCUPANT SELF-STORAGE, S-1: N/A (USING 500 GROSS FOR CALCULATIONS) PROPOSED: SEE SHEET PLANS - G203 & G204 1004.9 POSTING OF OCCUPANT LOAD EVERY ROOM OR SPACE WHICH IS USED FOR ASSEMBLY, CLASSROOM, DINING, DRINKING OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE, FOR THE INTENDED CONFIGURATIONS. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT. 1005.3: REQUIRED CAPACITY BASED ON OCCUPANT LOAD THE REQUIRED CAPACITY, IN INCHES (MM), OF THE MEANS OF EGRESS FOR ANY ROOM, AREA, SPACE OR STORY SHALL BE NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH SECTIONS 1005.3.1 AND 1005.3.2. 1005.3.1: STAIRWAYS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.3 INCH (7.6MM) PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE STAIRWAYS SERVING THAT STORY. REQ'D STAIR WIDTH: 36" MIN PROPOSED STAIR WIDTH: 38.5" MIN 1005.3.2: OTHER EGRESS COMPONENTS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1MM) PER OCCUPANT. PROPOSED: XXX OCCUPANTS / XXX EXITS = XXX XXX*.02= XXX MIN ALLOWED: 44" PER 1028.4 THE MIN WIDTH OR REQUIRED CAPACITY OF THE EXIT DISCHARGE SHALL BE NOT LESS THAN THE MINIMUM WIDTH ORREQUIRED CAPACITY OF THE EXITS BEING SERVED. BUILDING CODE SUMMARYAPPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 HERMOSA BEACH MUNICIPAL CODE (HBMC)OCCUPANCY CLASSIFICATION (302): BUSINESS: B MERCANTILE: M STORAGE: S-1CONSTRUCTION TYPE FOR EXISTING AND NEW PORTIONS OF PROJECT (601):TYPE: VB - 0 HOURFIRE SPRINKLER REQUIREMENTS (903):PER 903.2.7 - M OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM PER 903.2.9 - S1 OCCUPANCY: OUR BUILDING DOES NOT MEET CONDITIONS FOR REQUIRING A SPRINKLER SYSTEM REQUIRED: FIRE SPRINKLER NOT REQUIRED PROPOSED: NFPA 13 SPRINKLER PROVIDEDGENERAL CODECHAPTER 5: BUILDING HEIGHT AND AREA504 - 506 TABLE: ALLOWABLE BUILDING HEIGHTS, STORIES ABOVE GRADE PLAN, AND AREAS: TYPE VB CONSTRUCTION / SPRINKLERED / B OCCUPANCY: 60' H / 3-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / M OCCUPANCY: 60' H / 2-STORIES / 27,000 SF TYPE VB CONSTRUCTION / SPRINKLERED / S-1 OCCUPANCY: 60' H / 2-STORIES / 27,000 SF EXISTING HEIGHT / STORIES / AREA: 23.32' MIN - 24.48' MAX / 2 STORIES / 13,943 SFPROPOSED HEIGHT / STORIES / AREA: 28.81' MIN - 29.97' MAX / 3 STORIES / 13,885 SFCHAPTER 6: TYPES OF CONSTRUCTION601 TABLE: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS):PRIMARY STRUCTURAL FRAME 0 HR EXTERIOR BEARING WALLS 0 HR INTERIOR BEARING WALLS 0 HR INTERIOR NONBEARING WALLS AND PARTITIONS 0 HR FLOOR CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HR ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS 0 HRCHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES705.2: PROJECTIONSPROJECTS SHALL NOT EXTEND ANY CLOSER TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE THAN SHOWN IN TABLE 705.2705.2.2: TYPE III, IV, OR V CONSTRUCTIONPROJECTIONS FROM WALLS OF TYPE III, IV, OR V CONSTRUCTION SHALL BE OF ANY APPROVED MATERIAL705.5 FIRE-RESISTANCE RATINGSEXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH SECTION 601 AND 602. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF GREATER THAN 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE OF LESS THAN OR EQUAL TO 10' SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES. TABLE: FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (HOURS): GROUP B / TYPE VBLESS THAN 5'-0" 0 HR 5'-0" TO LESS THAN 10'-0" 0 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HRGROUP M & S-1 / TYPE VBLESS THAN 5'-0" 2 HR 5'-0" TO LESS THAN 10'-0" 1 HR 10'-0" TO LESS THAN 30'-0" 0 HR GREATER THAN 30'-0" 0 HR EXISTING SEPARATION DISTANCE (SEE SITE PLAN A101)705.8: OPENINGSOPENINGS IN EXTERIOR WALLS SHALL COMPLY WITH SECTION 705.8.1 THROUGH 705.8.6705.8.1: ALLOWABLE AREA OF OPENINGS EXCEPTION 2: BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR NONBEARING WALLS AND EXTERIOR PRIMARYSTRUCTURAL FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED SHALL BE PERMITTED TO HAVE UNLIMITEDUNPROTECTED OPENINGS.705.8.5: VERTICAL SEPARATION OF OPENINGS EXCEPTION 2: THIS SECTION SHALL NOT APPLY TO BUILDINGS THAT ARE THREE STORIES OR LESS ABOVE GRADE PLAN EXCEPTION 3: THIS SECTION SHALL NOT APPLY TO BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEMIN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.1.2705.11: PARAPETS PARAPETS SHALL BE PROVIDED ON EXTERIOR WALLS OF BUILDINGS EXCEPTION: A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF THE FOLLOWING CONDITIONS ARE MET - THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 705.5 BECAUSE OF FIRE SEPARATION DISTANCE708.6: OPENINGS (EXTERIOR WALL) OPENINGS IN A FIRE PARTITIONS SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716708.7: PENETRATIONS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION SHALL COMPLY WITH SECTION 714708.9: DUCTS AND AIR TRANSFER OPENINGS (EXTERIOR WALL) PENETRATIONS IN A FIRE PARTITION BY DUCTS AND AIR TRANSFER OPENINGS SHALL COMPLY WITH SECTION 717711.2.3: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) THE SUPPORTING CONSTRUCTION SHALL BE PROTECTED TO AFFORD THE REQUIRED FIRE-RESISTANCE RATING OF THEHORIZONTAL ASSEMBLY SUPPORTED EXCEPTION: IN BUILDINGS OF TYPE IIB, IIIB, OR VB CONSTRUCTION, THE CONSTRUCTION SUPPORTING THE HORIZONTALASSEMBLY IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED AT THE FOLLOWING: - HORIZONTAL ASSEMBLIES AT THE SEPARATIONS OF INCIDENTAL USES AS SPECIFIED BY TABLE 509.1 PROVIDED THAT THEREQUIRED FIRE-RESISTANCE RATING DOES NOT EXCEED 1 HOUR. - HORIZONTAL ASSEMBLIES AT SMOKE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 709711.2.4.1: SUPPORTING CONSTRUCTION (HORIZONTAL ASSEMBLIES) WHERE THE HORIZONTAL ASSEMBLY SEPARATES MIXED OCCUPANCIES, THE ASSEMBLY SHALL HAVE A FIRE-RESISTANCE RATINGOF NOT LESS THAN THAT REQUIRED BY SECTION 508.4 BASED ONT HE OCCUPANCIES BEING SEPARATED ALLOWABLE: NO SEPARATION REQUIREMENT REQUIRED711.3: NONFIRE-RESISTANCE-RATED FLOOR AND ROOF ASSEMBLIES NONFIRE-RESISTANCE-RATED FOOR, FLOOR/CEILING, ROOF AND ROOF/CEILING ASSEMBLIES SHALL COMPLY WITH SECTIONS711.3.1 AND 711.3.2 713.4: FIRE-RESISTANCE RATING (SHAFT WALLS) SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIESOR MORE, AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES. THE NUMBER OF STORIES CONNECTEDBY THE SHAFT ENCLOSURE SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES. SHAFT ENCLOSURES SHALL HAVE AFIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED BUT NOT EXCEED 2 HOURS. SHAFT ENCLOSURESSHALL MEET THE REQUIREMENTS OF SECTION 703.2.1.1 713.6: EXTERIOR WALLS (SHAFT WALLS) WHERE EXTERIOR WALLS SERVE AS A PART OF A REQUIRED SHAFT ENCLOSURE, SUCH WALLS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 705 FOR EXTERIOR WALLS AND THE FIRE-RESISTANCE-RATED ENCLOSURE REQUIREMENTS SHALL NOT APPLY. CHAPTER 9: FIRE PROTECTION SYSTEMS 906.1: PORTABLE FIRE EXTINGUISHERS EXTINGUISHERS REQUIRED PER SECTION 906.1 906.2: GENERAL REQUIREMENTS PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH THIS SECTION AND CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, CHAPTER 3. 906.3 TABLE: SIZE AND DISTRIBUTIONS LOW HAZARD OCCUPANCY MIN-RATED SINGLE EXTINGUISHER 2-A EXTINGUISHER MAX FLOOR AREA FOR UNIT 3,000 SF MAX FLOOR AREA FOR EXTINGUISHER 11,250 SF MAX DISTANCE OF TRAVEL TO EXTINGUISHER 75'-0" REQUIRED: PROVIDED: 906.5: CONSPICUOUS LOCATION PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS LOCATIONS WHERE THEY WILL HAVE READY ACCESS AND BE IMMEDIATELY AVAILABLE FOR USE. THESE LOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL, UNLESS THE FIRE CODE OFFICIAL DETERMINES THAT THE HAZARD POSED INDICATES THE NEED FOR PLACEMENT AWAY FROM NORMAL PATHS OF TRAVEL. 907: FIRE ALARM AND DETECTION SYSTEMS GROUP B, M, & S: MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT NOTIFICATION APPLIANCES WILL AUTOMATICALLY ACTIVATE THROUGHOUT THE NOTIFICATION ZONES UPON SPRINKLER WATER FLOW. 911: FIRE COMMAND CENTER NOT REQUIRED FOR S-1 OCCUPANCY WITH A SIZE LESS THAN 500,000 SF CHAPTER 10: MEANS OF EGRESS 1003.2: CEILING HEIGHT THE MEANS OF EGRESS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7'-6" ABOVE THE FINISHED FLOOR EXCEPTIONS: - SLOPED CEILINGS IN ACCORDANCE WITH SECTION 1208.2 - ALLOWABLE PROJECTIONS IN ACCORDANCE WITH SECTION 1003.3 - STAIR HEADROOM IN ACCORDANCE WITH SECTION 1011.3 - DOOR HEIGHT IN ACCORDANCE WITH SECTION 1010.1.1 - RAMP HEADROOM IN ACCORDANCE WITH SECTION 1012.5.2 - AREAS ABOVE AND BELOW MEZZANINE FLOORS IN ACCORDANCE WITH SECTION 505.2 1004.4: MULTIPLE OCCUPANCIES WHERE A BUILDING CONTAINS TWO OR MORE OCCUPANCIES, THE MEANS OF EGRESS REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY OF THAT SPACE. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYTEMS, THOSE EGRESS COMPONENTS SHALL MEET THE MORE STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED. 1004.5: AREAS WITHOUT FIXED SEATING THE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT OF AREA AS PRESCRIBED IN TABLE 1004.5 FOR AREAS WITHOUT FIXED SEATING, THE OCCUPANT LOAD SHALL BE NOT LESS THAN THAT NUMBER DETERMINED BY DIVIDING THE FLOOR AREA UNDER CONSIDERATION BY THE OCCUPANT LOAD FACTOR ASSIGNED TO THE FUNCTION OF THE SPACE AS SET FORTH IN TABLE 1004.5 WHERE AN INTENDED FUNCTION IS NOT LISTED IN TABLE 1004.5, THE BUILDING OFFICIAL SHALL ESTABLISH A FUNCTION BASED ON A LISTED FUNCTION THAT MOST NEARLY RESEMBLES THE INTENDED FUNCTION. PER TABLE 1004.5 OFFICE SPACE, (BUSINESS AREAS) B: 150 GROSS/OCCUPANT RETAIL, M: 60 GROSS/OCCUPANT RETAIL STORAGE, M: 300 GROSS/OCCUPANT SELF-STORAGE, S-1: N/A (USING 500 GROSS FOR CALCULATIONS) PROPOSED: SEE SHEET PLANS - G203 & G204 1004.9 POSTING OF OCCUPANT LOAD EVERY ROOM OR SPACE WHICH IS USED FOR ASSEMBLY, CLASSROOM, DINING, DRINKING OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE, FOR THE INTENDED CONFIGURATIONS. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR THE OWNER'S AUTHORIZED AGENT. 1005.3: REQUIRED CAPACITY BASED ON OCCUPANT LOAD THE REQUIRED CAPACITY, IN INCHES (MM), OF THE MEANS OF EGRESS FOR ANY ROOM, AREA, SPACE OR STORY SHALL BE NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH SECTIONS 1005.3.1 AND 1005.3.2. 1005.3.1: STAIRWAYS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.3 INCH (7.6MM) PER OCCUPANT. WHERE STAIRWAYS SERVE MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE STAIRWAYS SERVING THAT STORY. REQ'D STAIR WIDTH: 36" MIN PROPOSED STAIR WIDTH: 38.5" MIN 1005.3.2: OTHER EGRESS COMPONENTS THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYINGTHE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1MM) PER OCCUPANT. PROPOSED: XXX OCCUPANTS / XXX EXITS = XXX XXX*.02= XXX MIN ALLOWED: 44" PER 1028.4 THE MIN WIDTH OR REQUIRED CAPACITY OF THE EXIT DISCHARGE SHALL BE NOT LESS THAN THE MINIMUM WIDTH OR REQUIRED CAPACITY OF THE EXITS BEING SERVED. 1005.7.1 DOORS DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7 INCHES (178MM). DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF. 1006.1: NUMBER OF EXITS AND EXIT ACCESS DOORWAYS: MAXIMUM OCCUPANT LOAD OF SPACE: SEE SHEET G204 MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE: A/M OCCUPANCY : 75' (W/ SPRINKLER SYSTEM) B OCCUPANCY: 100' (W/ SPRINKLER SYSTEM) S OCCUPANCY: 100' (W/ SPRINKLER SYSTEM) 1006.3.3: EGRESS BASED ON OCCUPANT LOAD EACH STORY AND OCCUPIED ROOF SHAL HAVE THE MIN NUMBER OF SEPARATE AND DISTINCT EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.3. A SINGLE EXIT OR ACCESS TO A SINGLE EXIT SHALL BE PERMITTED IN ACCORDANCE WITH SECTION 1006.3.4. THE REQUIRED NUMBER OF EXITS, OR EXIT ACCESS STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT DISCHARGE OR A PUBLIC WAY. 1-500 OCC LOAD EXIT(S) PER STORY: 2 EXITS REQ'D PROPOSED: 2 EXITS 1007.1.1: TWO EXITS OR EXIT ACCESS DOORWAYS WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE- HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN THEM. INTERLOCKING OR SCISSOR STAIRWAYS SHALL BE COUNTED AS ONE EXIT STAIRWAY. EXCEPTION 2: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. SEE SHEET G205 FOR EGRESS DIAGRAMS 1008.2: ILLUMINATION REQUIRED THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE ISOCCUPIED. 1008.2: ILLUMINATION LEVEL UNDER NORMAL POWER THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 FOOTCANDLE (11 LUX) AT THE WALKING SURFACE. ALONG EXIT ACCESS STAIRWAYS, EXIT STAIRWAYS, AND AT THEIR REQUIRED LANDINGS, THE ILLUMINATION LEVEL SHALL NOT BE LESS THAN 10 FOOTCANDLES (108 LUX) AT THE WALKING SURFACE WHEN THE STAIRWAY IS IN USE. 1008.3: EMERGENCY POWER FOR ILLUMINATION THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. EMERGENCY ILLUMINATION TO BE IN ACCORDANCE WITH SECTION 1008.3.1-5 1008.3.3 ROOMS AND SPACES IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: ELECTRICAL EQUIPMENT ROOMS, FIRE COMMAND CENTERS, FIRE PUMP ROOMS, GENERATOR ROOMS, PUBLIC RESTROOMS WITH AN AREA GREATER THAN 300 SF 1008.3.4 DURATION THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. 9 9 SCALE: 3/32" = 1'-0"1 EXIT SEPARATION - FIRST FLOOR SCALE: 3/32" = 1'-0"2 EXIT SEPARATION - SECOND FLOOR SCALE: 3/32" = 1'-0"3 EXIT SEPARATION - THIRD FLOOR EXIT SEPARATION: DIAGONAL = 81'-4" PROPOSED = 39'-7" ALLOWABLE MINIMUM = 27'-1" DOOR SEPARATION: DIAGONAL = 51'-5" PROPOSED = 29'-0" ALLOWABLE MINIMUM = 17'-1" EXIT SEPARATION: DIAGONAL = 103'-5" PROPOSED = 67'-9" ALLOWABLE MINIMUM = 34'-5" *CBC 2022 1007.1.1 EXCEPTION #2 WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. Page 182 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 17 OF 136 G-204 CODE PLANS & SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9123456789101112131415161718UP18 RISERS (6 23/32") 6'-0"6'-0"6'-0" 6'-0"7'-6 1/4"5'-0"5'-0"5'-3" 2'-10 1/4"2'-10 1/4"2'-10 1/4"3'-3 1/4"3'-2 1/4"5G-204 5G-204 TRAVEL DISTANCE = 79'-0" TRAVEL DISTANCE = 87'-0" EXIT 1 EXIT 2 EXIT 3 EXIT 4EXIT 5EXIT 6EXIT 7EXIT 9 EXIT 8 TRAVEL DISTANCE = 29'-0" TRAVEL DISTANCE = 23'-0" RETAIL 104RETAIL 105 WINE STORAGE112 LOADING ZONE115 OFFICE110 STORAGE113 ELEVATOR 01 RSTRM 106 RSTRM 103 STAIR 02 114 STAIR 01 121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE 111 RETAIL 101 HALL 102 ELEV RM121 ELECTRIC RM120 TRANSFORMER 121 4G-204 4G-204 1234567 8 UP 20 RISERS (7") RESTRM 108 ACC. RSTRM 109 TRASH RM 119 DN 5G-204 5G-2045'-0"3'-8"25'-0"5'-0"5'-0"4'-1"3'-8"EXITACCESS TRAVEL DISTANCE = 44'-5" OPEN TO BELOWOPEN TO BELOW OPEN TO BELOW EXIT ACCESS TRAVEL DISTANCE = 71'-9"EXIT ACCESS TRAVELDISTANCE = 59'-0"TRAVEL DISTANCE = 33'-6" OPEN TO BELOW OFFICE207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02209 LOBBY203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED211 4G-204 4G-204 DN 123456 7UP 12 RISERS (6 1/2")12345678910111213141516 UP 16 RISERS (6 25/32") SK-1 SK-2 SK-3 F DW F 5G-204 5G-204 5'-0"3'-6"5'-0"3'-0"3'-2 1/2"45" CLR2'-8"4G-204 4G-204 EXIT ACCESS TRAVEL DISTANCE = 79'-0" ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN316 CONFERENCE RM 314 OFFICE 309 OFFICE304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM317 GARDEN311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN GREEN ROOF 307 LIFE SAFETY LEGEND EXIT ACCESS TRAVEL DISTANCE 1 HOUR RATED SEPARATION 2 HOUR RATED SEPARATION 3 HOUR RATED SEPARATION EXIT EXITS PER OCCUPANT LOAD EXIT 1: 2 OCCUPANTS EXIT 2: 2 OCCUPANTS EXIT 3: 31/2 = 16 TOTAL OCCUPANTS FROM BUSINESS LEVEL 3 6 TOTAL OCCUPANTS FROM BUSINESS LEVEL 2 1 TOTAL OCCUPANTS FROM BUSINESS LEVEL 1 23 TOTAL OCCUPANTS EXIT 4: 14/2 = 7 TOTAL OCCUPANTS FROM RETAIL 105 3/2 = 1.5 TOTAL OCCUPANTS FROM STORAGE 112 8.5 OCCUPANTS = 9 TOTAL OCCUPANTS EXIT 5: 14/2 = 7 TOTAL OCCUPANTS FROM RETAIL 105 3/2 = 1.5 TOTAL OCCUPANTS FROM STORAGE 112 8.5 OCCUPANTS = 9 TOTAL OCCUPANTS EXIT 6: 9 OCCUPANTS EXIT 7: 12 OCCUPANTS EXIT 8: 10/2 EXITS = 5 OCCUPANTS FROM STORAGE LEVEL 2 12 TOTAL OCCUPANTS FROM STORAGE 113 17 TOTAL OCCUPANTS EXIT 9:31/2 EXITS = 16 TOTAL OCCUPANTS FROM BUSINESS LEVEL 3 10/2 EXITS = 5 TOTAL OCCUPANTS FROM STORAGE LEVEL 2 21 TOTAL OCCUPANTS EXIT # GENERAL NOTES *ALL DOORS TO BE SIZED IN ACCORDANCE TO SECTION 1005.3.2 OF CBC *DEAD END CORRIDORS NOT TO EXCEED 50' IN ACCORDANCE TO SECTION 1020.5 OF CBC *TRAVEL DISTANCE SHALL NOT EXCEED 205 FT. FOR BUILDINGS SPRINKLED THROUGHOUT PER CBC SECTION 1004.2.3.2.2 (M) MERCANTILE OCCUPANT LEGEND (B) BUSINESS (S-1) STORAGE FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' -3.13'FOUNDATION -3.13'FOUNDATION ±0.00'1ST FLOOR ±0.00'1ST FLOOR +9.13'2ND FLOOR - STORAGE +9.13'2ND FLOOR - STORAGE +11.67'2ND FLOOR - OFFICE +11.67'2ND FLOOR - OFFICE +18.17'3RD FLOOR +18.17'3RD FLOOR +23.17'GARDEN ROOF +23.17'GARDEN ROOF +28.79'ROOF +28.79'ROOF 9 9 SCALE: 3/32" = 1'-0"1 FIRST FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0"2 SECOND FLOOR LIFE SAFETY PLAN SCALE: 3/32" = 1'-0"3 THIRD FLOOR LIFE SAFETY PLAN SCALE: 1/8" = 1'-0"5 BUILDING SECTION - NORTH/SOUTH 0 4'8'16' SCALE: 1/8" = 1'-0"4 BUILDING SECTION - EAST/WEST 0 4'8'16' RETAIL 105 (M) 817 SF 817/60 = 14 OCCUPANTS RETAIL 104 (M) 528 SF 528/60 = 9 OCCUPANTS RETAIL 101 (M) 708 SF 708/60 = 12 OCCUPANTS OFFICE 110 (B) 249SF 249/150 = 2 OCCUPANTS OFFICE 111 (B) 245 SF 245/150 = 2 OCCUPANTS LOBBY 107 (B) 122 SF 122/150 = 1 OCCUPANTS STORAGE 112 (S-1) 769 SF 769/300 = 3 OCCUPANTS TOTAL TRAVEL DISTANCE: 79'-0" STORAGE 02 (S-1) 2,685 SF 2,685/300 = 9 OCCUPANTS TOTAL TRAVEL DISTANCE: 87'-0" OFFICE 207 (B) 161 SF 161/150 = 2 OCCUUPANTS OFFICE 206 (B) 156 SF 156/150 = 2 OCCUUPANTS OFFICE 205 (B) 154 SF 154/150 = 2 OCCUUPANTS STORAGE 210 (S-1) 2,687 SF 2,687/300 = 9 OCCUUPANTS TOTAL TRAVEL DISTANCE: 86'-0" OFFICE (B) 4,611 SF 4,611/150 = 31 OCCUUPANTS TOTAL TRAVEL DISTANCE: 79'-0" *ALL DOORS TO BE SIZED IN ACCORDANCE TO SECTION 1005.3.2 Page 183 of 324 ANY CHANGES OR MODIFICATIONS MADE TO THIS PLAN WITHOUT WRITTEN CONSENT OF DENN ENGINEERS SHALL RELIEVE DENN ENGINEERS FROM ANY LIABILITY OR DAMAGE RESULTING FROM SUCH CHANGES OR MODIFICATIONS, INCLUDING ANY ATTORNEYS FEES OR COSTS INCURRED IN ANY PROCEEDING THAT DENN ENGINEERS MAY BE JOINED. CONCRETE BRICK 106.76 EXISTING ELEVATION BLOCK WALL LEGEND 100 EXISTING CONTOUR X EXISTING FENCE EXISTING BUILDING WOOD DECK THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF PROFESSIONAL LAND SURVEYORS' ACT R.C.E. 30826GARY J. ROEHL 3914 DEL AMO BLVD, SUITE 921 TORRANCE, CA 90503 (310) 542-9433 E N G IN E E R S JOB ADDRESS LEGAL DESCRIPTION FOR DRAWN BY CHECK BY SHEET 1 OF 1 DRAWN ON REVISIONS COPYRIGHT JOB NO. BCR BEGINNING OF CURB RETURN CATV CABLE TV PULL BOX CONC.CONCRETE CHMNY CHIMNEY CEFB CITY ENGINEERS FIELD BOOK C/L CENTERLINE C.L.F. / W.I.F.CHAIN LINK FENCE / WROUGHT IRON FENCE E'LY EASTERLY EG EDGE OF GUTTER EM ELECTRIC METER FF FINISH FLOOR FH FIRE HYDRANT FL FLOW LINE GFF GARAGE FINISH FLOOR GM GAS METER GUY / GW GUY WIRE I.P. IRON PIPE MONUMENT L&T LEAD AND TACK / TAG MONUMENT MH MANHOLE ( SANITARY SEWER / STORM DRAIN) N'LY NORTHERLY N&T NAIL AND TAG MONUMENT PB PULL BOX ( EDISON / TRAFFIC / STREET LIGHT PB (CONT)TELEPHONE / CABLE TV) PC PROPERTY CORNER / PROP. CORNER PL PROPERTY LINE / PROP. LINE PP / UP POWER POLE / UTILITY POLE PPT PARAPET PWFB PUBLIC WORKS FIELD BOOK R.R.RAIL ROAD RDFB ROAD DEPARTMENT FIELD BOOK R.S.RECORD OF SURVEY SPK / S&W SPIKE / SPIKE AND WASHER MONUMENT S'LY SOUTHERLY SSCO SANITARY SEWER CLEANOUT STK / STK&T STAKE / STAKE AND TAG MONUMENT STLT / LT STREET LIGHT POLE / LIGHT POLE TC TOP OF CURB TX / BX TOP OF APRON / BOTTOM OF APRON W'LY WESTERLY WM WATER METER BOUNDARY MONUMENTS ARE NOT NECESSARILY SET ON PROPERTY CORNERS. PLEASE REFER TO THE NOTATION ON THIS SURVEY PLAT FOR OFFSET DIMENSIONS. IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT DENN ENGINEERS FOR CLARIFICATION BY PHONE AT: (310) 542-9433, M-F 8:00 AM TO 5:00 PM. NOTE: ALL SETBACK DIMENSIONS SHOWN ARE MEASURED TO EXTERIOR SURFACE OF BUILDINGS UNLESS OTHERWISE NOTED. 901 HERMOSA AVENUE HERMOSA BEACH, CA 90254 LOT 25,26 AND 27, BLOCK 10 HERMOSA BEACH M.B. 1-25-26 APN 4187-003-028 SURVEY AND TOPOGRAHY FM GR SCALE 1" = 8' FEBRUARY 10, 2022 REVISIONS NORTH22-006 CARDINAL INVESTMENTS 2301 ROSECRANS AVENUE, SUITE 4130 EL SEGUNDO, CA, 90254 PHONE N 77°25'58"E 86.17'N 12°10'00"W95.11'N 77°26'20"E 86.16'N 12°10'00"W95.10'N 77°25'58"E 334.16'N 12°10'00"W135.11'N 77°26'20"E 323.80' 10TH COURT 9TH STREET HERMOSA AVENUE10.00'30.00'30.00'KYLE RANSFORD SET L&T RCE 30826 3.00' E'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=16.40' SET L&T RCE 30826 3.00' E'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=16.00' FOUND N&T RCE 30826 0.95' N'LY & 0.11' W'LY OF PROP. CORNER TAG ELEV.=15.24' FOUND L&T RCE 30826 23.00' S'LY OF CORNER ON PROP. LINE PROD. TAG ELEV.=15.19' 217.63' 20.00' 20.00' 227.99'16.2616.4915.2915.1115.78 TC15.20 FLCATV 15.30ED BOX 16.22 TC15.59 FLCATV15.8116.54 TC16.06 FL 16.2016.21 TX 15.88 FL 15.98 EG SIGN PARKING METER 15.892"GUARD POST 16.172"GUARD POST 16.122"GUARD POST 16.092"GUARD POST16.082"GUARD POST 16.142"GUARD POST 16.088"POST 16 . 9 9 16.0716.1216.0416.0416.35 TX 16.01 FL16.13 EG PARKING METER 16.2916.0916.0616.56 FF16.0516.0515.92 FF8"TREE 15.6215.7515.2215.3115.4117.54 TW 15.44 PC15.9015.9239 . 2 6 P A R A P E T 36.61 PARAPET32.46 PARAPET16.57 FF16.40 TC 16.10 FL PARKING METER 16.4215.2415.2116.56 PC16.44 SIGN 16.3716.2516.36 FL 16.44 TC 16.13 FL16.26 EG WV16.35WV 16.41FH 16.47SSMH16.2915.93 FF15.53TEL BOX 15.34WM15.2115.2415.4415.52EBOX 3*4 15.3215.4016.3615.6515.8315.8115.91 17.03 17.03 16.02 22.87 TW15.5416.9917.0416.5015.70N 16°33'18"W135.40'BEACH DRIVECONC. GUTTERCONC. SIDEWALK100' 20'80' FOUND PK NAIL PER R.S. 134-78 STA. 0+00.00STA. 0+38.192.8'20'10'10'60'30'30'20' 10'10' FOUNT 4 PM's IN MANHOLE RIM PER PWFB 0616-1732,1733 STA. 3+34.16 FOUND L&T 5909 ACCEPTED AS C/L INT. PER PWFB 0616-1732,1733 FOUND NAIL PER R.S. 134-78 CONC. CURB BUILDING IS 0.05' S'LY OF PROP. LINE. BUILDING IS 0.29' N'LY OF PROP. LINE BUILDING IS 0.27' N'LY OF PROP. LINE BUILDING IS 0.14' E'LY OF PROP. LINE BUILDING IS 0.09' E'LY OF PROP. LINE EXISTING RESIDENCE EXISTING RESIDENCE 58 10TH COURT APN 4187-003-027 LOT 24 LOT 25 LOT 26 LOT 27 30.00'95.11'10.00'106.17' 106.17' NOTE: A TITLE POLICY WAS NOT PROVIDED TO DENN ENGINEERS AT THE TIME OF THIS SURVEY. THEREFORE, DENN ENGINEERS DOES NOT GUARANTEE THE LEGAL DESCRIPTION OF THIS PROPERTY SURVEYED NOR DOES IT REFLECT OR DELINEATE ANY EASEMENTS THAT MAY BE ON SAID PROPERTY. Page 184 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 22 OF 136 AD-101 DEMOLITION SITE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 PL PL 05 06 12 02 07 01 HERMOSA AVENUE 10TH COURT9TH STREET(E) NEIGHBORING BUILDING (E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDINGABV PLPL PL PL PL PL 08 901 HERMOSA AVE (E) BUILDING FOOTPRINT 7,756 SQ FT 01 02 03 04 05 06 07 08 09 EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED EXISTING CONCRETE CURB TO BE REMOVED EXISTING COLUMN TO BE REMOVED EXISTING PLANTER BOX TO BE REMOVED EXISTING HARDSCAPE TO BE REMOVED EXISTING UTILITY BOX TO BE REMOVED. UTILITIES TO BE RELOCATED. EXISTING TREE TO BE REMOVED EXISTING BOLLARDS TO BE REMOVED SCALE: 3/16" = 1'-0"1 DEMO SITE PLAN 0 4'8'12' Page 185 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 23 OF 136 AD-111 DEMOLITION 1st FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING94'-2"7"10'-5"4'-7 1/2"8'-2"2'-0"8'-2"1'-9"4'-2 1/4"9'-2 1/2"3'-5 1/4"26'-9 1/2"2 1'-0" VIF 13'-2" #DrgID #LayID 1 PERM 1 A-201 2 A-201 01 14 02 04 03 03 03 03 030303 07 07 04 04 04 04 04 07 07 04 04 04 16 19 19 19 19 13 13 0101 070707 16 16161616 1616 1616 15 19 07VIF VIFPL PL SB PL PL PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS NOT USED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS SCALE: 1/4" = 1'-0"1 1st FLOOR DEMOLITION PLAN 0 2'4'8' Page 186 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 24 OF 136 AD-112 DEMOLITION 2nd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 #DrgID #LayID 1 PERM 1 A-201 2 A-201 04 01 04 030303040413 03 04 03 03 07 07 03 010101 0101 01 19 19 19 PL PL PL PL SB SB PL PL PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS NOT USED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS SCALE: 1/4" = 1'-0"1 2nd FLOOR DEMOLITION PLAN 0 2'4'8' Page 187 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 25 OF 136 AD-113 DEMOLITION ROOF PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 PL PL PL PL PL PL 1 A-201 2 A-201 1 PERM #DrgID #LayID 04 05 06 05 05 PL PL 01 02 03 04 05 06 07 08 09 11 10 12 13 14 15 16 17 18 19 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS NOT USED NOT USED NOT USED NOT USED NOT USED EXISTING WALL CORNER TO BE REMOVED. REPAIR TO MATCH ADJACENT. EXISTING ROLLUP DOOR SYSTEM TO BE REMOVED / REPLACED EXISTING UTILITIES TO BE RELOCATED. OPEN TO ABOVE NOT USED NOT USED EXISTING EXTERIOR STUCCO WALL FINISH AND WRB TO BE REMOVED AND REPLACED PER WALL ASSEMBLIES; TYP WALLS TO REMAIN WALLS TO BE DEMO'D NEW WALLS SCALE: 1/4" = 1'-0"1 DEMOLITION ROOF PLAN Page 188 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 26 OF 136 C-000 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtTITLE SHEET ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-000 TITLE SHEET N N “” “” “” “” ” ” “ ” “ ” Page 189 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 27 OF 136 C-100 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtEROSION CONTROL PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9N 77°25'58"E86.17'N 12°10'00"W95.11'N 77°26'20"E86.16'N 12°10'00"W95.10'N 77°25'58"E334.16'N 12°10'00"W135.11'N 77°26'20"E323.80'10.00' 30.00' 30.00'20.00'20.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 100'20'80'2.8'20'10'10'60'30'30'30.00'95.11'10.00'106.17'106.17'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-100 EROSION CONTROL PLAN Page 190 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 28 OF 136 C-210 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtGRADING AND DRAINAGE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 30.00'1 6 . 2 6 15.291 5 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16 . 1 22"GUARD POST1 6 . 0 92"GUARD POST16 . 0 82"GUARD POST1 6 . 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16 . 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 1 6 . 0 9 1 6 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE1 5 . 6 2 1 5 . 7 5 1 5 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 1 5 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 1 6 . 5 7 F F 16.40 TC16.10 FLPARKING METER16 . 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 1 6 . 2 516.36 FL16.44 TC16.13 FL16.26 EGWV1 6 . 3 5 WV1 6 . 4 1SSMH1 6 . 2 9 15 . 9 3 F F 1 5 . 5 3TEL BOX1 5 . 3 4WM15 . 2 1 1 5 . 2 4 1 5 . 4 4 1 5 . 5 2EBOX 3*415.321 5 . 4 0 16.36 1 5 . 6 5 1 5 . 8 3 1 5 . 8 115.9117.0317.0316.022 2 . 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16. 2 2 50 0 8 LT NT16. 2 2 50 1 0 LT NT16. 2 4 50 2 8 16. 2 2 50 3 2 16. 6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-210 GRADING AND DRAINAGE PLAN Page 191 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 29 OF 136 C-300 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtLOW IMPACT DEVELOPMENT PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 30.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-300 LOW IMPACT DEVELOPMENT PLAN Page 192 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 30 OF 136 C-400 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtUTILITY PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 30.00'16. 2 6 16 . 4 915.2915 . 1 1 15.78 TC 15.20 FLCATV 15 . 3 0 ED BOX16.22 TC 15.59 FL CATV15 . 8 1 16.54 TC 16.06 FL16 . 2 0 16.21 TX15.88 FL15.98 EGSIGNPARKING METER15 . 8 9 2"GUARD POST16 . 1 72"GUARD POST16. 1 22"GUARD POST16 . 0 92"GUARD POST16 . 0 82"GUARD POST16. 1 42"GUARD POST16 . 0 8 8"POST16.9916.0716 . 1 2 16. 0 4 16 . 0 4 16.35 TX16.01 FL16.13 EGPARKING METER16 . 2 9 16. 0 9 16 . 0 616.56 FF16.0516.0515 . 9 2 F F8"TREE15. 6 2 15. 7 5 15 . 2 2 15 . 3 1 15 . 4 117.54 TW 15 . 4 4 P C 15 . 9 0 15 . 9 2 39.26 PARAPET36.61 PARAPET32 . 4 6 P A R A P E T 16 . 5 7 F F 16.40 TC16.10 FLPARKING METER16. 4 2 15.2415 . 2 1 16.56 PC 16.44SIGN16 . 3 7 16. 2 516.36 FL16.44 TC16.13 FL16.26 EGWV16 . 3 5 WV16 . 4 1 FH16 . 4 7SSMH16. 2 9 15 . 9 3 F F 15. 5 3TEL BOX15 . 3 4WM15 . 2 1 15 . 2 4 15 . 4 4 15 . 5 2EBOX 3*415.3215. 4 016.36 15 . 6 5 15. 8 3 15. 8 115.9117.0317.0316.0222. 8 7 T W 15 . 5 4 16 . 9 9 17 . 0 4 16 . 5 0 15 . 7 0 2.8'5008LT NT16.22 5008 LT NT16.22 501 0 LT NT16.24 5028 16.2 2 503216.6 1 CD - WIP CONSTRUCTION DOCUMENTS SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powers DRAWN BY: RP COPYRIGHT: A B C D E 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for ARCHICAD 24/22007 - 901 Hermosa Ave - PowersPROJECT NAME 901 HERMOSA AVE, HERMOSA BEACH, CA, 90254 CLIENT KYLE RANSFORD #Client Phone Number PROJECT ADDRESS - -, - - ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA MARK DATE DESCRIPTION 319 Main Street El Segundo, CA 90245 T: 213.239.9700 LFA Job No. 22079 08/28/2023 OFIL NRCFOETAT S A AINo. C75121 CIVIL SIGN DATE 08/08/2025 Exp. 12/31/2025 C-400 UTILITY PLAN Page 193 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 60 OF 136 A-101 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtSITE PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 (E) SEWER (E) FIRE HYDRANT (E) CURB CUT PER SURVEY (E) EDISON BOX (N) TRASH ENCLOSURE (E) WATER METER SLOPE NOT TO EXCEED 6.67% (N) FIRE ROOM ENCLOSURE PROPOSED CONCRETE PLANTER NOT TO EXCEED 42" (E) CATV BOX (E) ELECTRICAL BOX (E) TELEPHONE BOX PROPOSED CONCRETE BENCH NOT TO EXCEED 20" (N) TRANSFORMER ENCLOSURE CLCL 11"83'-4"95'-1 1/4" 8'-1" WALKSTREET 21'-10 1/2" ENCROACHMENT 86'-2"PC 15.44'PC 15.24' PC 15.98' 16.35 TX EG 15.59 06 07 01 02 04 10 16.01 FL 5X5 10TH COURT5X5 5X5 5X5 5X5 5X10 5X5 5X5 5X10 5X10 5X5 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X105X10 5X5 5X5 5X15 2% SLOPE MAX ENTRY ENTRY ENTRY E N T R YENTRYENTRYENTRY ENTRYOPEN TO ABOVE SIM HERMOSA AVE 5X5 9TH STREETPLPL PL PL WS WS SBSB PL PL PL PL 10'-0"2'-11"20'-1/2"29'-11 1/2"5'-10"24'-3 1/4"PC 16.56' 39.26' TO PARAPET 39.26' TO PARAPET FF 16.56' FF 16.57' FF 15.93' 32.46' FF 16.56' 16.09' 16.06' FF 16.56' 32.46' TO PARAPET FF 16.56' FF 16.56' 03 THIRD STORY SETBACK ABOVE 05 12 11 08 14 SECOND STORY SETBACK ABOVE 901 HERMOSA AVE (E) BUILDING FOOTPRINT 7,756 SQ FT (E) NEIGHBORING BUILDING (E) CONCRETE SIDEWALK (E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDING(E) NEIGHBORING BUILDING9 9 SCALE: 3/16" = 1'-0"1 SITE PLAN 0 4'8'12' Page 194 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 61 OF 136 A-111 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtFOUNDATION PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 5 5 9 1/4" 2'-2 3/4"2'-1/2"HSS F5 F6 F6 F5 F5 F5 F5 F5 F5F5F4 F4 W12B W10B W8A W10B W10B W10B W10A TYP. ELEV. PIT ELEV. PIT2'-4 1/2"2'-7 1/2"3'-0"3'-0"2'-0"3'-3/4"1'-1 3/4"2'-4 1/4"1'-3/4"2'-5 1/4"5'-5"5'-5"6'-9 1/4"6'-8 3/4"1'-3/4"2'-5 1/4"6'-9"6'-9"1'-1/2"2'-5 1/2"7'-11 3/4" 1'-1/4"11 3/4"7'-11 3/4"8 1/4"2'-11 1/2"3'-2"2'-10"3'-3/4"6'-0"1'-10 1/2"2'-0"2'-0" PL PL PL PL SB SB 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 GRADE BEAM, SEE STRUCTUAL SET CONCRETE WALL, SEE STRUCTURAL SET TURN DOWN SLAB EDGE, SEE STRUCTURAL SET TYPICAL CONCRETE FOOTING, SEE STRUCTURAL SET EXISTING FOUNDATION STRUCTURAL WALL & COLUMN TAG, SEE STRUCTURAL SET INDICATES CHANGE IN FLOOR ELEVATION, SEE STRUCTURAL SET xx SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN 0 2'4'8' Page 195 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 62 OF 136 A-112 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - Powerscourt1st FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9115.2119.1118.1101.B104.A105.A 105.B107.1102.1102.2106.1121.1109.1108.1 103.1 120.1 115.1110.A 111.A111.1111.2110.2110.1101.1104.1 10 5.2 114.1115.3101.A 119.1123456789101112131415161718UP18 RISERS (6 23/32") 5 5CL121.1105.1 1 A-403 8 A-908 9 1/2"81'-11"3'-5 1/2"7 1/2" 94'-2" 7"2'-10 3/4"7'-9 1/2"CLR5'-0"5'-0" 5'-0"5'-0"5'-5 1/2"6'-6 1/4"2'-8 3/4" RO 10"3'-8"CLR14'-1/4"2'-0"3'-1 1/2"R.O.6'-8 3/4"3'-9"5'-1 1/2" 6'-11 1/2"12'-1/4"55'-0"9'-3 1/4"10'-11" VIF 7'-2"9'-2 1/2"RO1'-7"8'-6 3/4"5'-5"14'-11"14'-11"1'-1/4" 3'-4 1/4"19'-9"3'-3 1/2" R.O. 10'-9"7'-1/2"20'-2"4'-8 1/2"3'-1 1/2" R.O. 1'-3/4" 9'-1/4"8'-2" R.O.2'-0"8'-2" R.O.6'-1 1/4"10'-5"R.O.4'-7 1/2"4'-2 1/2"9 1/2"10'-7 1/2"RO2'-8"10"2'-1/2"10'-7 1/2"RO1'-4"2 1'-0" R O VIF 3'-3"21'-1/2" RO VIF 1'-11"3'-8" CLEAR3'-2 1/2"R.O.8 1/2"11'-3/4"3'-2 1/4"R.O.14'-6 3/4"6 3/4"4'-7"RO2'-10 1/4"5'-1 1/4"26'-8 1/2"11'-5"28'-1/2"15'-9"2'-10 3/4"RO5'-8"0 3/4"3'-2 1/4" R.O.7'-10 3/4"4'-2"R.O.4"8'-4 3/4"5'-11 1/2" 8'-4"CLR 3"3'-0"CLEAR3'-0"CLEAR4'-6 1/2" CLEAR PC 15.98' PC 15.56' PC 15.24' PC 15.44' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. -1.00' = 15.50' F.F. -0.97' = 15.53' F.F. 0.00' = 16.56' EG 15.75 EG 15.53 F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.56' F.F. 0.00' = 16.50' 2 A-204 1 A-204 1 A-203WT02-CWT07-B WT07-B WT07-BWT08-B WT05WT09-CWT10-A WT07-B WT07-BWT12 WT06 WT07-B WT07-BWT07-A WT07-BWT10-A WT02- A WT02-A WT11WT07-BWT07-AALIGNALIGNALIGNALIGN WT07-BWT07-BWT06WT11WT11 WT06WT06WT06WT02-C WT02-CWT10-BWT09-BALIGNALIGN WT03-AWT02-BALIGNALIGNWT02-CWT09-C WT03-B WT02-AWT02-AWT06WT02-CWT02-CWT06WT13 WT13WT06WT06 WT06 WT06 5X5 10TH COURT5X5 5X5 5X5 5X5 5X10 5X5 5X5 5X10 5X10 5X5 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X5 5X10 5X10 5X10 5X10 5X105X10 5X5 5X5 METER/ DIST. METER/ DIST. PULL/ MAIN 5X15 EP2% SLOPE MAX OPEN TO ABOVE WIRE WAY METER/ DIST. SIM CONTROLLER5X5 6'x8' RETAIL 104 RETAIL 105 WINE STORAGE 112 LOADING ZONE 115 OFFICE 110 STORAGE 113 ELEVATOR 01 RSTRM 106 RSTRM 103 STAIR 02 114 STAIR 01 121 FIRE (ASR) RM 118 RESTRM CORRIDOR 107 ELEVATOR 02 OFFICE 111 RETAIL 101 HALL 102 ELEV RM 121 ELECTRIC RM 120 TRANSFORMER 121 3 A-203 #DrgID #LayID 105.3 112.11234567 8 UP 20 RISERS (7") PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 1 A-401 1 A-402 2 A-404 3 A-404 1 A-404 5 A-908 12A-908 13 A-908 3'-6 3/4"15'-8" ROVIF2'-4 3/4"8'-2"R.O.18'-1 1/2"4'-1 3/4"3'-1 1/2"R.O.6"24'-1"23'-9 3/4" 1'-1" 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 03 03 03 WT11 03 0204 WT17 WT03-B13 13 13 13 RESTRM 108 ACC. RSTRM 109 TRASH RM 119 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE SCALE: 1/4" = 1'-0"1 1st FLOOR PLAN 0 2'4'8' Page 196 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 63 OF 136 A-113 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - Powerscourt2nd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 101.B104.A105.A 105.B 101.A DN 5 5 2 A-401 2 A-402 5 A-403 2 A-204 1 A-204 1 A-203 2 9'-2 1/4"3'-8 3/4"VIF15'-8"VIF12'-11 3/4"40'-1"5'-2 1/4"4'-5 1/4"7 1/2"6'-3"VIF11'-8 1/2"5'-1 1/4"12'-2 1/2"12'-4"14'-1 1/2"3'-8"CLR82'-6 3/4"2'-10"7 1/2" 94'-2" 3 1/2" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2" VIF 10 1/2"3'-2 1/4" R.O. 15'-11 1/2"4'-3 1/4"4'-9"5 1/2"26'-8 3/4"11'-5"28'-1/2"15'-9"4'-5" F.F. 11.67' = 28.17' F.F. 9.17' = 25.67' F.F. 11.67' = 28.17' F.F. 11.67' = 28.17' F.F. 11.67' = 28.17' F.F. 9.17' = 25.67' 3 A-203 WT10-BWT07-B WT07-B WT11 WT10-A WT07-B WT07-BWT07-BWT03-BWT02-A WT06WT12 WT06 WT05 WT11 42" GUARDRAIL WT09-BWT07-BWT10-BWT09-CWT09-C WT07-A WT07-A WT07-B WT02-BW T02-C WT08-BWT04-B WT06WT01WT14-B OPEN TO BELOW 5X5 5X10 5X10 5X10 5X5 5X5 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X10 5X5 5X5 5X105X105X105X105X10 5X5 5X5 5X5 5X5 5X5 5X5 5X5 5X10 OPEN TO BELOW OPEN TO BELOW OPEN TO ABOVE 5X5 5X5 5X5 5X5 5X5 5X15 5X5 5X5 OPEN TO TRANSFORMER BELOW 5X6 DECOMISISONED AREA 1340 SF OFFICE 207 OFFICE 206 OFFICE 205 ELEVATOR 01 ELEVATOR 02 STAIR 01 204 STAIR 02 209 LOBBY 203 STORAGE UNITS 210 HALLWAY 208 SPACE NOT USED 211 #DrgID #LayID DN PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 209.1 1234567UP 12 RISERS (6 1/2")12345678910111213141516UP 16 RISERS (6 25/32") 5 A-908 6 A-903 0905 03 03 WT06 WT17 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE 9 9 SCALE: 1/4" = 1'-0"1 2ND FLOOR PLAN 0 2'4'8' Page 197 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 64 OF 136 A-114 3rd FLOOR PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 316.A 316.1 316.B 316.C 320.A 320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A 305.1323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A 303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 5 5 F DW F 4 A-404 1 A-405 2 A-405 3 A-908 5 A-908 9 A-908 9 A-908 2 A-204 1 A-204 1 A-203 3 A-203 19'-8"7'-2 1/2"28'-1/4"2'-2"15'-11"9'-6 3/4"81'-11"94'-2" 13'-6 1/2"18'-1/4"27'-7 1/4"10'-4 3/4"15'-4 1/4"4'-7 3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2"2'-7 1/2"3'-3"R.O.3 3/4"5'-9" 6 1/2" 2'-8 1/2" RO 15'-3 1/4"9'-3"6'-2"7'-1/2"18'-9 3/4"15'-8 1/2"4'-9"2'-1"7'-6 1/4"4'-1 1/2"48'-3 3/4"45" CLR2'-7 1/4"4'-2" RO 2'-1 1/2" 28'-1"5'-0" 27'-5"20'-9"5'-6 1/2" VIF 26'-8 1/2"11'-5"28'-1/2"15'-9"10'-10 1/2"R.O.16'-11 1/4"12'-11"5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4"3'-0"14'-0" RO PC 15.24'PC 15.44' F.F. = 18.17' = 34.67' FF =18.25' = 34.75' FF = 18.17' = 34.67' #DrgID #LayID WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B W T 14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 W T 16WT16WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE OPENTO BELOW OPEN TO BELOW OPEN TO ABOVE OPEN TO ABOVE ELEVATOR 01 STAIR 02 324 MECHANICAL PLATFORM 312 OFFICE 305 GARDEN PATIO 303 OFFICE 301 OFFICE 315 OFFICE 308 OFFICE 310 COURTYARD 318 GARDEN 316 CONFERENCE RM 314 OFFICE 309 OFFICE 304 RSTRM 321 KITCHEN 319 ELEVATOR 02 RSTRM 322 OUTDOOR ROOM 317 GARDEN 311 GARDEN 320 GARDEN 323 VESTIBULE 306 STAIRWELL EXIT 325 RESTROOM CORRIDOR 324 MECH. PLATFORM 302 STAIR 01 327 PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 DN DN #DrgID #LayID 3 A-402 3 A-403 3 A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIFPC 15.56' 319.1 308.B 309.B 09 09 09 09 09 0505 06 06 06 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTO ABOVE 465 SQ FT LID PLANTER GREEN ROOF 307 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSEDBEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE SCALE: 1/4" = 1'-0"1 3RD FLOOR PLAN 0 2'4'8' Page 198 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 65 OF 136 A-115 ROOF PLAN ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSED BEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE 5 5 2 A-204 1 A-204 1 A-203 3 A-203 #DrgID #LayID 23'-5 1/4"29'-11 1/2"21'-11 1/2"68'-9"3'-1/4"17'-4 1/4"17'-9 1/4"6 1/4"42'-4 1/4"27'-4 1/2"3'-2 1/4"TO PL81'-11"7 1/2" 94'-2" 3 1/2" 3'-7 3/4"43'-6 1/4"21'-2 1/4"21'-9 1/4"4'-3/4" 6'-11 1/2"12'-1/4"55'-0"9'-3/4"11'-1 1/2"26'-8 3/4"11'-5"28'-1/2"15'-9"PC 16.07' PC 16.56' PC 15.24' PC 15.44' CP F PROPOSED: 45.93' ALLOWED: 53.78' LOWEST POINT ON SITE OPEN TO BELOW SLOPE 1/4":12" MIN.SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. SLOPE 1/4":12" MIN. 520 SQ FT SOLAR ZONE AREA OPEN TO BELOW OPEN TOBELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPENTO BELOW PL PL PL PL SB SB PL PL PL PL 3 3 E E D D C C B B 2 2 F F A A 4 4 1 1 2 A-203 1 A-302 1 A-301 1 A-301 2 A-303 2 A-301 2 A-301 CP A PROPOSED: 45.29' ALLOWED: 45.32' CP B PROPOSED: 45.29' ALLOWED: 45.47' CP C PROPOSED: 45.29' ALLOWED: 46.48'CP D1 PROPOSED: 45.29' ALLOWED: 46.15' CP D2 PROPOSED: 45.29' ALLOWED: 45.93' CP E1 PROPOSED: 48.60'ALLOWED: 53.78' CP E2 PROPOSED: 48.60' ALLOWED: 53.53' 01 01 01 01 06 06 06 01 07 06 06 ELEVATOR OVERRUN ELEVATOR OVERRUN SLOPE 1/4":12" MIN. SCALE: 1/4" = 1'-0"1 ROOF PLAN 0 2'4'8' 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.32 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP A:45.32 Prop. Ht. @ CP A:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.32 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP A:45.32 Prop. Ht. @ CP A:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'90.83 Distance from A to Critical Point along Line AB Elev. AB':15.43 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'90.83 Distance from C to Critical Point along Line CD Elev.CD':16.09 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 5 Distance from Line AB to Critical Point (width) Elev. CP1:15.47 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP B:45.47 Prop. Ht. @ CP B:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'4.35 Distance from A to Critical Point along Line AB Elev. AB':15.25 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'4.35 Distance from C to Critical Point along Line CD Elev.CD':16.54 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 82.42 Distance from Line AB to Critical Point (width) Elev. CP1:16.48 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP C:46.48 Prop. Ht. @ CP C:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'73.13 Distance from A to Critical Point along Line AB Elev. AB':15.39 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'73.13 Distance from C to Critical Point along Line CD Elev.CD':16.18 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 82.42 Distance from Line AB to Critical Point (width) Elev. CP1:16.15 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP D1:46.15 Prop. Ht. @ CP D1:45.29 901 HERMOSA AVE North P.C. Elevation 15.24 Lot Width = 86.17’P.C. Elevation 16.56 (Point A)(Point C) West East Lot Length = 95.10’Lot Length = 95.11’ P.C. Elevation 15.44 P.C. Elevation 16.07 (Point B)Lot Width = 86.16’(Point D) South Dotted Lines = Property Lines Critical Height Calculation For: 901 HERMOSA AVE Elev. Pt. A 15.24 Lowest property corner (PC) elevation, this elevation will be reference as A from hereon Elev. Pt. B 15.44 PC elevation of corner at end of length, this elevation point will be reference as B Length A-B 95.1 Distance from A to B (lot length) Length A-AB'90.83 Distance from A to Critical Point along Line AB Elev. AB':15.43 Elev. Pt. C 16.56 PC elevation of corner across width of A, this elevation point will be reference as C from hereon Elev. Pt. D 16.07 PC elevation of corner at end of length of C, this elevation point will be reference as D Length C-D 95.11 Distance from C to D (lot length) Length C-CD'90.83 Distance from C to Critical Point along Line CD Elev.CD':16.09 Length AB'-CD'86.16 Lot width at Critical Point Length AB'-CP1 65.52 Distance from Line AB to Critical Point (width) Elev. CP1:15.93 Height Limit 30 Allowable height limit in the R-3 zone (25' limit for R-1 zone) Max. Ht. @ CP D2:45.93 Prop. Ht. @ CP D2:45.29 Page 199 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 72 OF 136 A-201 EXISTING ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING97"16.09' 15.54' 05 02 06 03 0404 02 06 02 0303 0404 07 07 07 PL PL 1ST FLOOR+16.50' 2ND FLOOR+24.50' ROOF+34.00' T.O. PARAPET+39.80" 39.26' 36.61' EXISTING GRADE EXISTING SLAB ON GRADE EXISTING STEP INTO PROPERTY 01 02 03 04 05 06 07 08 09 11 10 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS NOT USED NOT USED NOT USED NOT USED 0505 0404 EXISTING GRADE EXISTING SLAB PLPL 1ST FLOOR+16.50 2ND FLOOR+24.50 ROOF+34.00' T.O. PARAPET+39.80' 15.46'15.50' SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION - EXISTING 0 2'4'8' SCALE: 1/4" = 1'-0"2 WEST ELEVATION - EXISTING 0 2'4'8' Page 200 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 73 OF 136 A-202 EXISTING ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9030303 06 03 04 04 04 04 0404 (E) STEP INTO ENTRY 03 07 PLPL 1ST FLOOR+16.50' 2ND FLOOR+24.50' ROOF+34.00' T.O. PARAPET+39.80' 16.05' 16.09'16.56' 39.26' 36.61'1'-0"15.44' 05 04 02 02 03 0404 07 07 070707 07 PLPL 1ST FLOOR+16.50'" 2ND FLOOR+24.50' ROOF+34.00' T.O. PARAPET+39.80' 16.50' (E) BUILDING SLAB(E) ALLEY (E) DOOR 1' ABOVE GRADE 01 02 03 04 05 06 07 08 09 11 10 ALL INTERIOR WALLS TO BE REMOVED DOOR TO BE REMOVED REMOVE EXISTING WINDOW OR DOOR SYSTEM. NEW WINDOW OR DOOR SYSTEM TO BE INSTALLED IN SAME LOCATION EXISTING WALL TO REMAIN. MAINTAIN STRUCTURAL INTEGRITY EXISTING ROOF TO BE REMOVED EXISTING AWNING TO BE REMOVED EXISTING WALL TO BE REMOVED. SEE PROPOSED PLAN/ELEVATIONS FOR DIMS NOT USED NOT USED NOT USED NOT USED SCALE: 1/4" = 1'-0"2 EAST ELEVATION - EXISTING 0 2'4'8' SCALE: 1/4" = 1'-0"1 NORTH ELEVATION - EXISTING 0 2'4'8' Page 201 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 74 OF 136 A-203 PROPOSED ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 1 2 3 4 5 9'-1 1/2"9'-1/2"10'-7 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"CP B 45.29'CP D1 45.29'CP D2 45.29'10'-0"19.17' CP E1 48.50'4'-7"10'-2 1/2" RO8'-0"MAX ELEV HT6A-908 8 A-908 10A-908 13A-908 12A-908 09 04 107.1 MAXIMUM ROOF HEIGHT SLOPE 111.2 110.2 110.1111.1 111.A 110.A CW-A CW-B STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-4 GL-4 CW-C PL PL PC15.44' PC16.07' PC46.07' 45.44' 7A-908 11A-908 CO-4 CO-4 CO-2 01 02 03 04 05 06 07 08 09 10 11 12 13 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD OPEN TO BELOW NEW APERTURES TO BE RECESSED BEHIND PROPERTY LINE; DOORS NOT TO PROJECT OVER PROPERTY LINE PLPLCABDEF FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'4'-7"3'-11"28'-9 1/2"CP B 45.29'CP A 45.29' CP E2 48.50'CP E1 48.50' 09 STC-1 MT-3 (E) SLAB (N) GRADE MAXIMUM ROOF HEIGHT (E) GRADE CW-K CW-L STC-1 MTL-3MTL-3 MTL-5 GL-1 MTL-5 GL-1 MTL-3MTL-3 312.1 MTL-5 PC15.24'PC15.44' 45.35'45.44'1'-0"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"CP D2 45.29'CP D1 45.29'6 1/4"1'-6"12'-10"VIF105.B105.2 SLOPE PER CIVIL CW-D STC-1 MTL-5 MTL-4 GL-1 GL-4 28'-9 1/2"SCALE: 1/4" = 1'-0"2 SOUTH ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"3 WEST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"1 SOUTHWEST ELEVATION 0 2'4'8' Page 202 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 75 OF 136 A-204 PROPOSED ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 PL PLDFECBA FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'1'-6"VIF9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"28'-9 1/2"CP D2 45.29'CP C 45.29'CP D1 45.29'12'-11 1/2"VIFCP E2 48.50'CP E1 48.50' CP F 45.93' 1 A-904 2A-904 9A-904 11A-904 7A-904 5A-904 4A-904 3A-904 04 09 105.1 104.A 101.B105.A MAXIMUM ROOF HEIGHT 104.1 101.1 CW-D CW-F STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-3MTL-3 CW-E PC16.05' PC16.56 5 4 3 2 1 FOUNDATION +13.38' 1ST FLOOR +16.50' 2ND FLOOR - STORAGE +25.63' 2ND FLOOR - OFFICE +28.17' 3RD FLOOR +34.67' GARDEN ROOF +39.67' ROOF +45.29'1'-3"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"28'-9 1/2"CP C 45.29' CP A 45.29' 24.13' CP F 45.93' CP E2 48.50'8'-0"MAX ELEV HT8'-10 1/2"R.O. +24.13' 09 04 115.2 MAXIMUM ROOF HEIGHT 119.1 114.1 CW-G CW-H CW-I STC-1 MTL-5 MTL-4 GL-1 GL-4 MTL-3 10 CW-JCW-F MTL-5 121.1 118.1115.3 PLPL PC15.24' PC16.56' 45.24' 46.56'7'-8" RO7'-8" RO7'-8" RO7'-8" RO(E) ALLEY (E) BUILDING SLAB HEAD HEIGHT TO MATCH 7'-0" AFF 01 02 03 04 05 06 07 08 09 10 11 TRASH ENCLOSURE OPEN TO BELOW CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP TELEPHONE BACKBOARD SCALE: 1/4" = 1'-0"2 EAST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"1 NORTH ELEVATION 0 2'4'8' Page 203 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 77 OF 136 A-301 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtBUILDING SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 01 02 03 04 05 06 07 08 09 10 11 12 TRASH ENCLOSURE OPEN TO BELOW BENCH CONCRETE PLANTER CURTAIN WALL SYSTEM STUCCO CURB MOUNTED SKYLIGHT LINE OF FLOOR BELOW PLANTED ROOFTOP STORAGE SYSTEM BY OTHERS ROOF DRAIN WITH OVERFLOW HOUSE EP DG GROUT SLOPE NOT TO EXCEED 6.67% CONCRETE PAVER TELEPHONE BACKBOARD OPEN TO BELOW CONCRETE SLAB AT GRADE PLANTER PAD-MOUNTED TRANSFORMER PER SCE (E) BOLLARDS TO BE REPLACED WITH REMOVABLE BOLLARDS 1 A-905 3 A-905 3 A-904 8 A-904 1 A-904 1 A-902 1 A-902 4 A-902 2 A-902 2 A-902 4 A-902 4 A-906 FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79'28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"5A-904 6 A-904 7A-904 4A-904 FT04 FT04 FT04 FT04 RT02 FT02FT02 RT01 RT01 RT01 RT05 SIM SIM SIM SIM SIM OFFICE 301 STAIR 02 114 LOADING ZONE 115 ELEVATOR 02 STORAGE UNITS 113 RETAIL 101 STAIR 02 209 STORAGE UNITS 210 STORAGE UNITS 210 GARDEN 316 OFFICE 315 CONFERENCE RM 314 STAIR EXIT 325STAIR 02 324 TRANSFORMER 121 9 A-904 4 A-906 FT01FT01FT01FT01 RT02 2 A-904 1 A-904 1 A-902 1 A-902 1 A-902 1 A-906 1 A-906 3 A-902 4 A-902 3 A-905 5 A-902 1 A-906 FOUNDATION -3.13' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79'28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"4'-0"5A-904 FT04 FT07 RT02FT07FT04 FT02 FT01 FT01 FT04 RT01RT01 RT01 LID PLANTER BEYOND LID PLANTER BEYOND FT02 PERGOLA SIM SIM SIM SIM SIM GARDEN 323 COURTYARD 318 RECEPTION 317 GARDEN PATIO 303 RSTRM CORRIDOR324 STAIR 02 209 STORAGE UNITS 210 RETAIL 104 STORAGE UNITS 113 SIM SCALE: 1/4" = 1'-0"1 BUILDING SECTION - E/W 0 2'4'8' SCALE: 1/4" = 1'-0"2 BUILDING SECTION - COURTYARDS E/W 0 2'4'8' Page 204 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 78 OF 136 A-302 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtBUILDING SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING9 1 A-902 1 A-902 1 A-905 4 A-902 1 A-906 1 A-906 2 A-906 2 A-907 1 A-902 3 A-902 4 A-908 FOUNDATION -3.13' FOUNDATION -3.13' 1ST FLOOR ±0.00' 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' 3RD FLOOR +18.17' GARDEN ROOF +23.17' GARDEN ROOF +23.17' ROOF +28.79' ROOF +28.79'28'-9 1/2"9'-1 1/2"2'-6 1/2"6'-6"5'-0"5'-7 1/2"4'-6 1/2"FT06FT03 FT07 FT02 FT01 FT04FT04 RT02 FT01 FT02 FT01 FT02 FT01 FT01 RT01RT01 RT03 SIM SIM COURTYARD 318 OFFICE 308 OFFICE 205 SPACE NOT USEDSTORAGE UNITS 210 LOBBY 107 RESTROOM 109 WINE STORAGE 112 STORAGE UNITS 113 LOADING ZONE 115 CONFERENCE RM 314 SIM SIM SIM SIM 3 A-906 SCALE: 1/4" = 1'-0"1 BUILDING SECTION N/S 0 2'4'8' Page 205 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 79 OF 136 A-303 1 1 2 2 3 3 4 4 5 5 6 6BIMcloud: Laney LA - BIMcloud Basic for Archicad 26/22007 - 901 Hermosa Ave - PowerscourtWALL SECTIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 11-06-23 PLANNING SUBMITTAL 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET PLANNING SUBMITTAL806-27-25 10-08-25 PLANNING COM. HEARING92.8960.9141.8541.3461.829HSS COLUMN BEYOND FIRE STOPPING WALL TBD PER T24 ROOF DRAIN 2ND FLOOR - STORAGE +12'-1.5" 3RD FLOOR - OFFICE +19.58' ROOF GARDEN +24.00' 2ND FLOOR - STORAGE +9'-2" 1ST FLOOR +0.00' ROOF +30.00' 3 A-904 1ST FLOOR ±0.00' 2ND FLOOR - STORAGE +9.13' 2ND FLOOR - OFFICE +11.67' 3RD FLOOR +18.17' GARDEN ROOF +23.17' ROOF +28.79' FT06FT03 FT02 FT01FT01 SCALE: 1/2" = 1'-0"1 WALL SECTION C 0 1'2'4' SCALE: 1/2" = 1'-0"2 WALL SECTION A - COORDINATION 0 1'2'4' Page 206 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 80 OF 136 A-401 STAIR 01 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING97'-4"CLR44" CLR6'-7 1/2" CLR 4'-7"RO MIN.4A-401 8A-401 9A-401 OPEN TO ABOVE ELEVATOR 01 STAIR 01 121 RESTRM CORRIDOR 107 1234567 8 UP 20 RISERS (7")4 4" 1 A-302 7A-401 6A-401 5 A-401 10A-401 ACC. RSTRM 109 4A-401 8A-401 9A-40144"44" CLR44" CLR44" CLR ELEVATOR 01 STAIR 01 204 LOBBY 203 DN 7A-401 6A-401 5 A-401 10A-401 1234567UP 12 RISERS (6 1/2") 4A-401 8A-401 9A-401 44" CLROPEN TO BELOW OPEN TO BELOW ELEVATOR 01 GARDEN 311 VESTIBULE 306 STAIR 01 327 7A-401 6 A-401 5A-401 10 A-401 DN 34 5 A-903 16 A-903 8 A-903 34" - 38"42" MINGUARDAIL42" MINGUARDAILFT05 FT01 FT03 SIM E DF 4 A-903 7 A-903 34" - 38"12" FT01 FT06 FT03 SIM E DF 3 A-903 1 A-903 4 A-903 +13.38'FOUNDATION +16.50' 1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17' 2ND FLOOR - OFFICE +34.67' 3RD FLOOR +39.67' GARDEN ROOF +45.29' ROOF 34" - 38"12" 11"42"GUARDRAILFT06 FT03 FT05 FT01FT012 A-90334" - 38"E DPLF 8 A-903 +4.077 FOUNDATION +5.029 1ST FLOOR +7.8112ND FLOOR - STORAGE +8.585 2ND FLOOR - OFFICE +10.566 3RD FLOOR +12.090 GARDEN ROOF +13.805ROOF FT03FT06 FT01 RT05 RT01RT01 FT05 D E F +160 1/2"FOUNDATION +198" 1ST FLOOR +307 1/2" 2ND FLOOR - STORAGE +338" 2ND FLOOR - OFFICE +416" 3RD FLOOR +476" GARDEN ROOF +543 1/2" ROOF FT06FT03 FT05 D E F FT01 FT03 FT06 FT05 FT01 3 4 +160 1/2" FOUNDATION +198" 1ST FLOOR +307 1/2" 2ND FLOOR - STORAGE +338" 2ND FLOOR - OFFICE +416" 3RD FLOOR +476" GARDEN ROOF +543 1/2" ROOF FT05 FT01 SCALE: 1/4" = 1'-0"1 1ST FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"2 2ND FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR STAIR / ELEVATOR 01 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"7 STAIR 01 SECTION SOUTH 0 2'4'8'SCALE: 1/4" = 1'-0"6 STAIR 01 SECTION WEST 0 2'4'8' SCALE: 1/4" = 1'-0"5 STAIR 01 SECTION WEST 0 2'4'8'SCALE: 1/4" = 1'-0"10 ELEVATOR SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"4 STAIR 01 SECTION EAST SCALE: 1/4" = 1'-0"8 STAIR 01 SECTION EAST SCALE: 1/4" = 1'-0"9 STAIR 01 SECTION NORTH 0 2'4'8' Page 207 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 81 OF 136 A-402 STAIR 02 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9123456789101112131415161718UP18 RISERS (6 23/32")45"CLR12" 4 A-402 5A-402 5X10 5X5 5X5 5X5 5X55X5 STAIR 02 114 PL SB C B A 1 1 A-301 2 A-301 6A-402 13 DN 4A-402 5 A-402 12"45"CLEAR45"CLEARR 45" 5X10 STAIR 02 209 PL SB C B A 1 1 A-301 2 A-301 6 A-402 12345678910111213141516UP 16 RISERS (6 25/32") 4A-402 5 A-402 4 A-403 45" CLR15"-16" OPEN TO ABOVE OPEN TO ABOVE OPEN TO ABOVE STAIR 02 324 GARDEN STAIRWELL EXIT 325 PL SB C B 2 A 1 1 A-301 2 A-301 6 A-402 DN PLA B C 9 A-903 12 A-903 11 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF 7'-1/4"3'-0"PLA B C 12 A-903 11 A-903 9 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF 7'-7"3'-0"SIM SIM SIM 10 A-903 +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF SCALE: 1/4" = 1'-0"1 1ST FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"2 2ND FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR STAIR PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"4 STAIR 02 SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"5 STAIR 02 SECTION 0 2'4'8' SCALE: 1/4" = 1'-0"6 STAIR 02 SECTION 0 2'4'8' Page 208 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 82 OF 136 A-403 STAIR 03 & ELEVATOR 02 PLAN & SECTION ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING97'-9 1/2"CLR8'-4"CLR 4'-2" RO MIN. 4 A-403 5X10 5X5 CONTROLLERFIRE (ASR) RM 118 ELEVATOR 02 ELEV RM 121 TRASH RM 119 4 A-403 4'-2" RO MIN.7'-9 1/2"CLR8'-4" CLR 5X105X10 5X5 5X5 5X5 5X5 5X6 ELEVATOR 02 STORAGE UNITS 210 4 A-403 7'-9 1/2"CLR36" DBL DOOR TALL CABINET 30" DBL DOOR BASE CABINET 36"30"36" 170 7/8" OVERALL 1 1/2"24"8'-4" CLR OPEN TO ABOVE ELEVATOR 02 STAIRWELL EXIT 325 MECH. PLATFORM 302 2 +13.38' FOUNDATION +16.50'1ST FLOOR +25.63' 2ND FLOOR - STORAGE +28.17'2ND FLOOR - OFFICE +34.67'3RD FLOOR +39.67'GARDEN ROOF +45.29' ROOF SCALE: 1/4" = 1'-0"1 1ST FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"5 2ND FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"3 3RD FLOOR ELEVATOR 02 PLAN 0 2'4'8' SCALE: 1/4" = 1'-0"4 ELEVATOR 2 SECTION 0 2'4'8' Page 209 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 83 OF 136 A-404 ENLARGED BATHROOM PLANS & ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 CL CL 17"-18" 12" MIN 24" MIN 36" MIN 33"-36"17"-19"36" PT-1 SURFACE MOUNTED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR 40" MAX48"29" MIN11" MIN 8" MIN 9"MINTL-1 ACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW PT-1 48" MAX18"RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE PT-1 TL-1 TO LOBBY CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 12" MAX 54" MIN 24" MIN19" MIN1 1/2" MAX7"-9" PT-1 TL-1 109.1108.1 CL CL CL CLCL 18"18"22"22"18"18" 1A 1B 1C 1D A-404 1E 1F 1G 1H A-404 106.1CLCL18"18"22" 2A 2B 2C 2D A-404 103.1 CL CL 12"48"12" 2B 2A 2D 2C A-404SIM 320.A 320.1 323.A 316.1320.B 321.1 322.1 2 1/2" MAX 3" MAX1 1/2" MAX15"-16" 3A 3B 3D 3C A-404 3H 3E 3F 3G A-404 OPEN TO ABOVE OPEN TO ABOVE 48" MAX28" PT01 TL01 MIRROR CL CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.40" MAX.17"-18"17"-19"RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.33"-36"PT01 TL01 +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.34" MAX.29" MIN.9"MIN.11" MIN. 8" MIN. PT01 TL01 ACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW TO RESTROOM CORRIDOR CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTINGCEILING HT.33"-36"12" MAX. 42"MIN.19"MIN.54"MIN. 7"-9"1 1/2"MAX.24" MIN. PT01 ACCESSIBLE TOILET W/ FLUSH CTRL @ OPEN SIDE OF TOILET TL01 8" MIN 48" MAX18" TL-1 TO LOBBY +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. PT-1 29" MIN11"MIN 9"MINACCESSIBLE SINK & FAUCET W/ INSUL DRAIN PIPE BELOW RECESSED PAPERTOWEL DISPENSER AND RECEPTACLE +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. TL-1 PT-1 +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT.33"-36"36"MIN. 24" MIN 12" MIN 17"-18"17"-19"18" MIN 40" MAX48"31" PT01 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR CL CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 1" 11" 54" MIN. PT01 27"MIN. (KNEE)9MIN. (TOE)8"MIN. (KNEE)6"MAX. (TOE) 17"MIN. +0'-0" A.F.F. PT01 CL +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. 17"-18" 12" MIN 24" MIN 36" MIN 33"-36"17"-19"32" PT-1 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") TL-1 MIRROR 40" MAX48"+0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT.29"2 1/2" 8 1/2"MAX.2 1/2" PT01 +0'-0" A.F.F. +8'-0" A.F.F. V.I.F. TO EXISTING CEILING HT. PT01 TL01 TO RETAIL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. 36"48" MAX33" MIN16" MIN 27" MAX PT01 MIRROR 6" MAX SHOWER CONTROL BOUNDARY LOCATION 40" MAX48"15"6'8"-7'-0" TYP.SHOWER HEAD HT.+0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. PT01 TL01 CL CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT.34" MAX12" MIN 24" MIN 36" MIN 33"-36"17"-18"29" MIN11" MIN 8" MIN 9"MIN17"-19"48" MAXPT-1 RECESSED TOILET PAPER DISPENSER; MOUNT UNDER GRAB BAR (MIN CLR 1-1/2") ACCESSIBLE SINK &FAUCET W/ INSUL DRAIN PIPE BELOW RECESSED PAPERTOWEL DISPENSER AND RECEPTACLE CL +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT.24"42" MIN 12" MAX 54" MIN 24" MIN33"-36"19" MIN1 1/2" MAX7"-9" PT-1 WALL BEHIND PT-1 ACCESSIBLE TOILET W/ FLUSH CTRL @ OPEN SIDE OF TOILET TL-1 SCALE: 3/8" = 1'-0"1A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1D RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1 LOBBY RESTROOM SCALE: 3/8" = 1'-0"2 RETAIL RESTROOM 106 SCALE: 3/8" = 1'-0"3 RETAIL RESTROOM 103 SCALE: 3/8" = 1'-0"4 OFFICE RESTROOM 3E OFFICE RESTROOM 3G OFFICE RESTROOM 3H OFFICE RESTROOM3FOFFICE RESTROOM SCALE: 3/8" = 1'-0"1H RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1G RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1E RESTROOM ELEVATION SCALE: 3/8" = 1'-0"1F RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"2D RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3A RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3B RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3C RESTROOM ELEVATION SCALE: 3/8" = 1'-0"3D RESTROOM ELEVATION Page 210 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 84 OF 136 A-405 ENLARGED KITCHEN PLANS & ELEVATIONS ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. 169 3/8"OVERALL 2 1/4" 84"84"5/8"36"69 1/2"105 1/2"CL 76"29 1/2"329 3/4" OVERALL 105 1/2"OVERALL17"10"10"36"40"29 1/2"7 1/2"7 1/2"7 1/2"7 1/2"7 1/2"161"161" 1/4" +0'-0" A.F.F. +8'-9 1/2" A.F.F. V.I.F. TO EXISTING CEILING HT. DW CL F DW F 59"36"24" DRAWER 24" DRAWER 36" SINK 24"24" DRAWER 36"59" 322 1/2" OVERALL 1 9/16"24"1A F F 319.1 36" DBL DOOR TALL CABINET 30" DBL DOOR BASE CABINET 36"30"36" 170 7/8" OVERALL 1 1/2"24"2A SCALE: 1/2" = 1'-0"2A BAR ELEVATION SCALE: 1/2" = 1'-0"1A KITCHEN ELEVATION SCALE: 1/2" = 1'-0"1 ENLARGED PLAN - KITCHEN SCALE: 1/2" = 1'-0"2 ENLARGED PLAN - BAR Page 211 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 85 OF 136 A-501 DETAILS - WALL ASSEMBLIES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 WT02WT07 WT13 WT03 WT09 WT11 WT04 WT10 WT01 WT05 WT06 WT08 WT12 WT14 WT15 WT16 WT17 TYP FURR'G WALL @ EXIST PERIMTYP INT WALL TYP SHAFT WALL CONC FURR'G WALL @ EXIST PERIM CONC INT WALL ELEV 01 EXT/INT WALL TYP EXT MTL STUD WALL TYP INT DOUBLE STUD WALL EXT/EXT STUD WALL @ ROOF TYP UNCONDITIONED STUD WALL TYP UNCONDITIONED / INT STUD WALL CONC EXT/INT WALL ELEVATOR 02 WALL CONC LID PLANTER WALL @ 3RD FLOOR EXT STUD WALL @ 3RD FLOOR CLERESTORY CONC FURR'G WALL @ 3RD FLOOR LID PLANTER @ EXIST PERIM CONC EXT WALL TYP EXT BUILD UP TYP EXT BUILD UP TYP EXT BUILD UP TYP EXT BUILD UP SECTION FIRE RATING: STC RATING: 2 HOUR (GA FILE NO. WP 8191) N/A A: 6" STL STUD B: 10" STL STUDC: 12" STL STUD TYPE:SECTION FIRE RATING: STC RATING: N/A N/A A: 2X4 STUD B: 2X6 STUDC: 2X10 STUD TYPE: SECTION FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 6852) N/A A: N/A B: N/A C: N/A TYPE:SECTION FIRE RATING: STC RATING: N/A N/A A: 8" THICK B: 10" THICK C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: 8"B: 10" C: 12" TYPE: SECTION FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 1072) N/A A: N/A B: C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: 6" STL STUDB: 10" STL STUD C: N/A TYPE: (N) 3-PART STUCCO SYSTEM; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-19 MINERAL WOOL INSUL (N) 5/8" GWB (N) FINISH PER SCHED 5/8" GWB; BACKERBOARD AS REQ'D FOR TILE FINISH PER SCHED 5/8" GWB; BACKERBOARD AS REQ'D FOR TILE FINISH PER SCHED MINERAL WOOL INSUL; FOR SOUND ATTENUATION; FILL CAVITY PLYWD SHEATH'G AS REQ'D; PER STRUCT (3) 5/8" GWB FINISH PER SCHED INTERIORINTERIOR SHAFT INTERIORINTERIOR INTERIOREXTERIOR 2X STUD WALL; PER PLAN 2-1/2" LT GA STL STUD ELEV SHAFTEXTERIOR 5/8" GWB TYP X FINISH PER SCHEDULE (N) 3/8" DRAINAGE LAYER (N) WRB INTERIOREXTERIOR (N) METAL SIDING (N) SHEATH'G PER STRUCT (N) 2X STUD WALL (N) MINERAL WOOL INSUL; R-19 (N) 5/8" GWB (N) FINISH PER SCHEDULE FINISH PER SCHED (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) 3/8" STUCCO DRAIN MAT (N) LT GA STL STUD WALL; PER TYPE (N) 3-PART STUCCO FINISH; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-15 MINERAL WOOL INSUL (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) 3/8" STUCCO DRAIN MAT (N) 3/4" CONC FORMWORK; W/O MEMB OR VAPOR BARRIER; TO BE BURRIED IN WALL; REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE (N) FINISH PER SCHED EXTERIOR (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) FINISH PER SCHED INTERIOR SECTION FIRE RATING: STC RATING: N/A N/A A: 1/2" AIR GAP B: 3" AIR GAP C: TYPE: INTERIORINTERIOR (2) 4" LT GA STL STUD WALL MINERAL WOOL INSUL; FOR SOUND ATTENUATION 5/8" GWB FINISH PER SCHEDULE MINERAL WOOL INSUL; FOR SOUND ATTENUATION SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) 3/8" STUCCO DRAINAGE MAT (N) WRB EXTERIOREXTERIOR (N) 3-COAT STUCCO SYSTEM; FINISH COLOR PER SCHEDULE (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGEDBOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) PLYWD SHEATH'G PER STRUCT SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB UNCONDITIONED (N) 5/8 GWB; EXT RATED (N) 2X STUD WALL UNCONDITIONED (N) FINISH PER SCHEDULE (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) WRB (N) 5/8 GWB; EXT RATED (N) FINISH PER SCHEDULE SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB INTERIOR (N) 5/8 GWB; EXT RATED (N) 2X STUD WALL UNCONDITIONED (N) FINISH PER SCHEDULE (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) PLYWD SHEATH'G AS REQ'D; PER STRUCT (N) 5/8 GWB (N) FINISH PER SCHEDULE (N) R-15 MINERAL WOOL INSUL SECTION FIRE RATING: STC RATING: N/A N/A A: 8" THICK B: 10" THICK C: TYPE: (N) CONC WALL; PER STRUCT (N) 5/8" GWB INTERIOR (N) FINISH PER SCHED EXTERIOR (N) MTL FINISH PER SCHED (N) WRB (N) 3/8" STUCCO DRAIN MAT AIR GAP 5/8" GWB; EXT RATED TYP X FIRE RATING: STC RATING: 1 HOUR (GA FILE NO. WP 1072) N/A A: N/A B:C: TYPE: ELEV SHAFTINTERIOR 5/8" GWB TYP X FINISH PER SCHEDULE FINISH PER SCHED MINERAL WOOL INSUL; FOR SOUND ATTENUATION 5/8" GWB TYP X 2X FRAM'G PER STRUCT 2X FRAM'G PER STRUCT NOTE:- THIS CONDITION WILL OCCUR AT ALL EXISTING EXPOSED PARAPET WALLS. - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP SECTION FIRE RATING: STC RATING: N/A N/A A: 6" THICKB: 8" THICK C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: N/A C: N/A TYPE: (N) WRB INTERIOREXTERIOR PLANTER (N) EXT SHEATH'G PER STRUCT (N) 2X STUD WALL (N) AIR GAP PER TYPE (N) FINISH PER SCHEDULE (N) 5/8" GWB (N) CONC WALL; PER STRUCT (N) 5/8" GWB PLANTER (N) FINISH PER SCHED (N) WRB (N) 1" RIGID INSULATION INTERIOR (N) 1/2" FURR'G CHANNEL (N) MINERAL WOOL INSUL; R19 SECTION FIRE RATING: STC RATING: N/A N/A A: B: C: TYPE: (N) 3-PART STUCCO FINISH; FINISH COLOR PER SCHED (N) WRB (E) 1X6 ANGLED BOARD SHEATH'G; DAMAGED BOARDS TO BE REPLACED AS REQ'D W/ APPROVAL BY ARCH (E) 2X6 STUD WALL (N) R-15 MINERAL WOOL INSUL (N) CONC WALL; PER STRUCT PLANTER (N) 3/8" STUCCO DRAIN MAT (N) 3/4" CONC FORMWORK; W/O MEMB OR VAPOR BARRIER; TO BE BURRIED IN WALL; REMOVE (E) 1X6 ANGLED BOARD SHEATH'G AS REQ'D @ INT WALL FACE (N) WRB EXTERIOR NOTE: - PER DEMO SHEETS; ALL EXISTING EXTERIOR SIDING AND WRB TO BE REMOVED AND REPLACED PER TYP EXTERIOR BUILD UP WRB SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: (N) 10" CONC WALL; PER STRUCT EXTERIOREXTERIOR Page 212 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 86 OF 136 A-502 DETAILS - FLOOR / ROOF / CEILING ASSEMBLIES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 FT02 FT03 FT01 FT04 RT01 RT02 RT03 FT06 FT07 FT05 RT04 RT05 CONC O/ MTL DECK @ STORAGE CONC O/ MTL DECK @ 2ND FLR OFFICE TYP SOG INFILL CONC O/ MTL DECK @ 3RD FLR OFFICE TYP ROOF TYP ROOF @ LID PLANTER GREEN ROOF EXT. WALKWAY @ 2ND FLOOR EXT COURTYARD @ 3RD FLOOR CONC O/ MTL DECK @ 3RD FLR LANDING/ ENTRY ROOF @ 3RD FLOOR MECH. DECK ELEVATOR ROOF PER STRUCT1 1/2"VARIESNTSVARIESPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTPER STRUCTVARIESPER STRUCTVARIESPER STRUCTF.F.E. SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: N/A N/A SECTION FIRE RATING: STC RATING: A: N/AB: C: TYPE: N/A N/A A: N/A B: C: TYPE: A: N/A B: C: TYPE: A: N/A B:C: TYPE: SLOPE INSUL TO DRAIN SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED SECONDARY FULLY- ADHERED MEMB ROOF'G 1/2" COVERBOARD 1/2" DRAINAGE MAT PRIMARY; FULLY-ADHERED 60 MIL MEMB ROOF'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT DRAINAGE LAYER; PER GREEN ROOF MFR PEDESTAL SYSTEM; PER MFR EXTENSIVE TRAY GREEN ROOF SYSTEM; INSTALLED BY OTHERS STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION (NOINSUL @ STORAGE CEILING; TYP) 1/2" RESILIENT CHANNEL 5/8" GWB (NO GWB @ STORAGE CEILING; TYP) FINISH PER SCHED MTL DECK'G PER STRUCT FINISH PER SCHED STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT 1-1/2" CONC TOPP'G SLAB REINFORCED CONC SLAB; PER STRUCT; TIE INTO (E) FOUNDATION AS SPEC'D BY STRUCT 1-1/2" TOPP'G SLAB; TO FLUSH OUT W/ (E) SLAB AS REQ'D FINISH PER SCHED 10 MIL VAPOR RETARDER; 12" MIN OVERLAP @ SEAMS; TAPED 2" MIN RIGID INSUL (R10); AS REQ'D 6" FREE-DRAINING CLEAN GRAVEL (1/4" MIN - 2" MAX DIA AGGREGATE) COMPACT SUBGRADE; STRUCT FILL WHERE REQ'D STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB (NO GWB @ STORAGE CEILING; TYP) FINISH PER SCHED MTL DECK'G PER STRUCT 1-1/2" CONC TOPP'G SLAB 1/4" ACOUSTIC UNDERLAYMENT FINISH FLOOR AS SCHEDULED SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B: C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL FINISH PER SCHED PEDESTAL SYSTEM; PER MFR PAVER O/ PEDESTAL SYSTEM PER SCHED; INSTALLED PER MFR 1/2" RESILIENT CHANNEL 5/8" GWB 1" RIGID INSUL WICKING GEO-TEXTILE; PER MFR PERMAVOID STRUCTURAL CELLS PLANTING MEDIUM PER LANDSCAPE PLANS WICKING GEO-TEXTILE; PER MFR SECTION FIRE RATING: STC RATING: N/A N/A A: N/A B:C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1" MIN RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL FINISH PER SCHED PEDESTAL SYSTEM; PER MFR PAVER O/ PEDESTAL SYSTEM PER SCHED 1/2" RESILIENT CHANNEL 5/8" GWB EXTERIOR INTERIOR EXTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR INTERIOR SECTION FIRE RATING: STC RATING: A: N/A B: C: TYPE: N/A N/A STRUCT CONC O/ MTL DECK; PER STRUCT JOIST; PER STRUCT MINERAL WOOL INSUL; FOR SOUND ATTENUATION 1/2" RESILIENT CHANNEL 5/8" GWB; EXT RATED AS REQ'D FINISH PER SCHED MTL DECK'G PER STRUCT RIGID INSUL; FILL AS REQ'D TO FLUSH OUT TOPP'G SLAB 1-1/2" CONC TOPP'G SLAB; FLUSH OUT W/INT OFFICE FLR EXTERIOR INTERIOR STRUCT CONC O/ MTL DECK; PER STRUCT MTL DECK'G PER STRUCT SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G JOIST; PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL R-38 MINERAL WOOL INSUL 1/2" RESILIENT CHANNEL 5/8" GWB FINISH PER SCHED MTL DECK'G PER STRUCT SECTION FIRE RATING:N/A N/A A: N/AB: C: TYPE: SLOPE INSUL TO DRAIN FULLY- ADHERED 60 MIL MEMB ROOF 1/2" COVERBOARD 1" MIN.RIGID INSUL; SLOPED TO DRAIN; MIN 1/4":12" AIR/VAPOR BARRIER PLYWD SHEATH'G HOIST BEAM, PER STRUCT 3" CLOSED CELL SPRAY FOAM INSUL 2X STL STUDS SECTION FIRE RATING:N/A N/A A: N/A B: C: TYPE: STRUCT CONC O/ MTL DECK; PER STRUCT MTL DECK'G PER STRUCT MTL DECK'G PER STRUCT AIR/VAPOR BARRIER STRUCT CONC O/ MTL DECK; PER STRUCT Page 213 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 87 OF 136 A-601 FINISH SCHEDULE & MATERIAL LEGEND ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 303 304 305 306 307 308 309 310 311 312 314 315 316 317 318 319 320 321 322 323 324 324 325 327 GARDEN PATIO OFFICE OFFICE VESTIBULE GREEN ROOF OFFICE OFFICE OFFICE GARDEN MECHANICAL PLATFORM CONFERENCE RM OFFICE GARDEN OUTDOOR ROOM COURTYARD KITCHEN GARDEN RSTRM RSTRM GARDEN RESTROOM CORRIDOR STAIR 02 STAIRWELL EXIT STAIR 01 GL-2 GL-2 PL-1 / GL-2 GL-2 GL-2 GL-2 PL-1 / GL-2 PT-1 STC-1 PL-1 / GL-1 PL-1 / GL-1 GL-1 GL-2 MT-1 / GL-2 WD-3 MT-3 PL-1 TL-1 / GL-2 MT-3 PL-1 PT-1 PT-1 N/A PL-1 / GL-1 PL-1 / GL-1 PL-1 / GL-1 MT-1 / GL-3 PL-1 / GL-2 PL-1 PL-1 PT-1 STC-1 PL-1 PL-1 / GL-2 PL-1 / GL-2 GL-2 MT-1 / GL-2 GL-2 MT-3 PL-1 PL-1 MT-3 PL-1 PT-1 PT-1 MT-1 GL-2 PL-1 PL-1 / GL-1 MT-1 PL-1 PL-1 PL-1 PT-1 STC-1 GL-2 GL-2 PL-1 / GL-2 GL-2 MT-1 / GL-2 WD-3 PL-1 / GL-2 PL-1 PL-1 PL-1 / GL-2 PL-1 PT-1 PT-1 N/A GL-2 GL-2 PL-2 MT-1 / GL-3 PL-1 PL-1 PL-1 / GL-1 PT-1 N/A PL-1 / WD-3 PL-1 PL-1 / GL-2 GL-2 MT-1 / GL-2 PL-1 / WD-3 PL-1 / GL-2 PL-1 PL-1 MT-3 PL-1 PT-1 PT-1 MT-1 / GL-3 N/A N/A TM-2 TM-1 N/A TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 N/A N/A TM-2 TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A N/A N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 TM-1 N/A TM-2 TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A N/A N/A N/A TM-2 N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 N/A N/A N/A TM-2 TM-1 TM-2 TM-2 TM-2 TM-5 N/A TM-2 TM-2 N/A N/A N/A TM-1 N/A TM-3 TM-3 N/A TM-2 TM-5 TM-5 TM-1 / GL-3 WD-1 WD-1 WD-1 CO-2 WD-1 WD-1 WD-1 WD-1 N/A WD-1 WD-1 N/A WD-1 WD-1 TL-1 TL-1 WD-1 CO-1 CO-1 CO-2 OTS PL-1 PL-1 MT-1 OTS PL-1 PL-1 PL-1 PT-1 PT-1 PL-1 PL-1 OTS PL-1 OTS PL-1 OTS PL-1 PL-1 OTS PL-1 PT-1 PT-1 MT-1 ST-1 ST-1 SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS, SEE ELEVATIONS SEE INTERIOR ELEVATION SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS SEE INTERIOR ELEVATION SEE LANDSCAPE PLANS SEE LANDSCAPE PLANS FINISH SCHEDULE ROOM NUMBER 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 118 119 120 121 121 121 203 204 205 206 207 208 209 210 211 301 302 303 NAME ELEVATOR 01 ELEVATOR 02 RETAIL HALL RSTRM RETAIL RETAIL RSTRM RESTRM CORRIDOR RESTRM ACC. RSTRM OFFICE OFFICE WINE STORAGE STORAGE STAIR 02 LOADING ZONE FIRE (ASR) RM TRASH RM ELECTRIC RM ELEV RM STAIR 01 TRANSFORMER LOBBY STAIR 01 OFFICE OFFICE OFFICE HALLWAY STAIR 02 STORAGE UNITS SPACE NOT USED OFFICE MECH. PLATFORM GARDEN PATIO WALL NORTH PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 N/A PT-1 PT-1 PT-1 PL-1 / GL-1 PT-1 GL-2 EAST PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 STC-1 PT-1 PT-1 PT-1 PL-1 / GL-1 PT-1 PL-1 / GL-1 SOUTH PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 STC-1 MT-1 PL-1 PL-1 PL-1 STC-1 PT-1 PT-1 PT-1 GL-2 PT-1 GL-2 WEST PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-2 PT-1 PT-1 MT-1 MT-1 MT-1 PL-1 PL-1 PL-1 N/A PT-1 PT-1 PT-1 GL-2 PT-1 GL-2 BASE NORTH TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 TM-2 TM-5 N/A EAST TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 TM-2 TM-5 N/A SOUTH TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 TM-5 N/A TM-5 N/A WEST TM-4 TM-4 TM-5 TM-4 TM-4 TM-5 TM-1 TM-3 TM-3 TM-2 TM-2 TM-4 TM-5 TM-5 TM-5 TM-5 TM-1 TM-5 TM-5 TM-1 TM-1 MT-1 TM-2 TM-2 TM-2 N/A TM-5 TM-5 N/A TM-5 N/A FLOOR CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-2 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-1 CO-2 CO-2 CO-2 CO-1 CO-1 CO-1 CO-3 CO-1 CO-1 CO-1 WD-1 CO-1 WD-1 CEILING PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 MT-1 PT-1 PT-1 PL-1 PL-1 PT-1 OTS PT-1 OTS OTS OTS OTS OTS MT-1 MT-1 MT-1 PL-1 PL-1 OTS PT-1 OTS PTS PL-1 PT-1 OTS COUNTERTOP & BACKSPLASH REMARKS BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN BASE TRIM TO BE 6" MIN SEE STORAGE UNIT SPECS FOR WALL FINISH SEE STORAGE UNIT SPECS FOR WALL FINISH SEE LANDSCAPE PLANS FINISH SCHEDULE ROOM NUMBER NAME WALL NORTH EAST SOUTH WEST BASE NORTH EAST SOUTH WEST FLOOR CEILING COUNTERTOP & BACKSPLASH REMARKS FINISH LEGEND TAG DESCRIPTION VENDOR/MANUFACTURER MODEL FINISH/COLOR SIZE LOCATION NOTES CO-1 CONCRETE FLOOR TBD TBD TBD TBD 101 - 106, 108 - 120, 201, 202, 205 - 207, 209 - 211 TOPPING SLAB CO-2 CONCRETE FLOOR - BUSH HAMMERED 107, 121, 319 TOPPING SLAB BUSH HAMMERED CO-3 CONCRETE PEDESTAL SYSTEM 208 PAVERS TO MATCH CO-2 CO-4 TEXTURED CONCRETE EXTERIOR PLANTERS GL-1 GLASS CURTAIN WALL ARCADIA TBD TBD TBD SEE ELEVATIONS GL-2 GLASS PARTITION WALL ARCADIA TBD TBD TBD SEE PLANS GL-3 GLASS RAILING ARCADIA TBD TBD TBD 306 GL-4 GLASS STOREFRONT ARCADIA TBD TBD TBD SEE ELEVATIONS MT-1 METAL PANELING - DECORATIVE TBD TBD TBD TBD 107, 121, 203, 204, 306, 327 MT-2 METAL PANELING - PROTECTION TBD TBD TBD TBD 119 TRASH ROOM MT-3 METAL PANELING - EXTERIOR 312, 320, 323 EXTERIOR GRADE MT-4 ALUMINUM STOREFRONT LIGHT CHAMPAGNE 101, 104, 105 STOREFRONT / 110, 111 IN 1ST FLOOR OFFICE MT-5 ALUMINUM CURTAIN WALL MEDIUM BRONZE 2ND FLOOR AND 3RD FLOOR OTS OPEN TO STRUCTURE PL-1 PLASTER - LEVEL 5 FINISH TBD TBD TBD TBD 110, 111, 205, 206, 207 PT-1 PAINT 101 - 106, 108, 109, 112, 114, 116 - 118, 120, 201, 202, 209, 211, 311, 324 - 326 ST-1 GRANITE COUNTER TOP TBD TBD TBD TBD 314, 319 STC-1 3 PART STUCCO - EXTERIOR COAT TBD TBD TBD TBD SEE ELEVATIONS TL-1 TILE TBD TBD TBD TBD 321, 322 WD-1 WOOD FLOOR TBD TBD TBD TBD 301, 302, 304, 305, 308 - 311, 314, 315, 317, 324 WD-2 WOOD WALL TBD TBD TBD TBD WD-3 WOOD MILLWORK TBD TBD TBD TBD 314, 319 TM-1 BASE TRIM - METAL TBD TBD TBD TBD 107, 119, 121, 203, 204, 306, 327 TM-2 BASE TRIM - 3/8" REVEAL TBD TBD TBD TBD 110, 111, 205, 206, 207, 301, 304, 305, 308, 309, 310, 314, 315, 317, 324 TM-3 BASE TRIM - TILE 6"TBD TBD TBD TBD 108, 109, 321, 322 TM-4 BASE TRIM - WOOD TBD TBD TBD TBD 101, 102, 104, 105, 112, TM-5 BASE TRIM - RUBBER TBD TBD TBD TBD 103, 106, 112 - 118, 120, 201, 202, 209, 210, 211, 311, 324, 325, 326 SCALE: 1' = 1'-0"2 FINISH SCHEDULE CONTINUED SCALE: 1' = 1'-0"1 FINISH SCHEDULE SCALE: 1' = 1'-0"3 FINISH LEGEND Page 214 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 88 OF 136 A-602 DOOR + WINDOW SCHEDULES ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 INTERIOR DOOR SCHEDULE ID 102.1 102.2 103.1 105.3 106.1 108.1 109.1 112.1 209.1 301.1 304.1 305.1 308.1 309.1 310.1 314.1 314.2 321.1 322.1 325.1 325.2 ROOM NAME RETAIL RETAIL HALL RESTRM CORRIDOR RSTRM RESTRM CORRIDOR ACC. RSTRM WINE STORAGE STAIR 02 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONFERENCE RM OFFICE RSTRM RESTROOM CORRIDOR STAIRWELL EXIT STAIRWELL EXIT TYPE D D D D D D D D M B B B B B B B B C C C I OPERATION INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING INT. SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING INT. SWING NET FRAME WIDTH 3'-1/2" 3'-1/2" 3'-1/2" 3'-2 1/2" 3'-1/2" 2'-10 1/2" 3'-1/2" 3'-2 1/2" 3'-4" 3'-2" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-3 1/4" 2'-8" 2'-9 1/2" 3'-2" 3'-0" NET FRAME HEIGHT 8'-1 1/4" 8'-1 1/4" 6'-9 1/4" 7'-1 1/4" 8'-1 1/4" 6'-9 1/4" 6'-9 1/4" 7'-1 1/4" 6'-10" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 6'-10" MATL HM HM HM HM HM HM HM HM HM ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS SC WOOD SC WOOD HM HM FRAME MATL HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM WD WD HM HM DETAIL HEAD 4/908 4/908 4/908 4/908 4/908 4/908 4/908 4/908 4/908 JAMB 5/908 5/908 5/908 5/908 5/908 5/908 5/908 5/908 5/908 HDWR. SET 2 2 3 3 3 3 3 3 6 2 2 2 2 2 2 2 2 3 3 2 3 ACCESORIES RATINGS FIRE Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated 1.5 hours Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated Unrated 45 minutes Unrated STC Manufacturer ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA REMARKS EXTERIOR DOOR SCHEDULE ID 101.1 104.1 105.1 105.2 107.1 110.1 110.2 111.1 111.2 114.1 115.1 115.2 115.3 119.1 120.1 121.1 303.1 306.1 312.1 316.1 316.1 317.1 319.1 320.1 ROOM NAME RETAIL RETAIL RETAIL RETAIL RESTRM CORRIDOR OFFICE OFFICE OFFICE OFFICE STAIR 02 LOADING ZONE LOADING ZONE LOADING ZONE LOADING ZONE STORAGE GARDEN PATIO VESTIBULE GARDEN GARDEN OUTDOOR ROOM COURTYARD GARDEN TYPE H H H H K L H L H E E F E F F E B A C B B J J B OPERATION EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. DOUBLE SWING EXT. PIVOT EXT. SWING EXT. BI-FOLD EXT. SWING EXT. BI-FOLD EXT. SWING EXT. SWING EXT. ROLL-UP EXT. SWING EXT. ROLL-UP EXT. ROLL-UP EXT. SWING SWING PIVOT SWING SWING SWING EXT. SLIDING EXT. SLIDING SWING NET FRAME WIDTH 5'-9 1/2" 5'-9 1/2" 5'-9 1/2" 5'-9 1/2" 9'-1 1/2" 3'-6" 7' 3'-6" 6'-11 1/2" 3'-4" 3' 10'-4" 3' 8'-2" 14'-2 1/4" 3' 3' 6'-1 1/2" 3' 2' 2' 14' 26'-5" 2'-1/8" NET FRAME HEIGHT 9'-10" 9'-10" 9'-10" 9'-10" 10' 10' 7'-4" 10' 7'-4" 6'-10" 7' 7'-8 1/4" 7' 7'-8" 7' 7' 8'-9 1/2" 8'-9 1/2" 8'-9 1/2" 6'-9 1/4" 6'-9 1/4" 8'-10" 8'-10" 6'-9 1/4" MATL ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS SC WOOD ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS HM HM HM HM HM HM HM ALUM / GLASS ALUM / GLASS HM ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS FRAME MATL HM HM HM HM WD HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM DETAIL HEAD 8/904 8/904 8/904 8/904 10/908 6/908 6/908 6/908 6/908 4/908 4/908 4/908 4/908 --- 4/908 1/902 1/908 4/908 1/902 1/902 1/908 1/908 1/902 JAMB 11/904 11/904 11/904 11/904 12/908 7/908 8/908 8/908 8/908 5/908 5/908 5/908 5/908 --- 5/908 3/908 3/908 5/908 3/908 3/908 9/908 9/908 3/908 HDWR. SET 1 1 1 1 1 1 3 1 3 6 6 5 6 5 5 6 2 1 3 2 2 2 2 3 ACCESORIES RATINGS FIRE Unrated Unrated Unrated Unrated 1 hour 1 hour 1 hour 1 hour 1 hour 1.5 hours 45 minutes 1 hour 20 minutes 1 hour 1 hour 20 minutes Unrated Unrated 30 minutes Unrated Unrated Unrated Unrated Unrated STC --- Manufacturer ARCADIA ARCADIA ARCADIA ARCADIA CUSTOM ARCADIA ARCADIA ARCADIA ARCADIA JANUS JANUS JANUS ARCADIA ARCADIA ARCADIA ARCADIA REMARKS 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 10" BOTTOM RAILS W/ ADA THRESHOLD 8" LEAF / STEEL W/ CLADDING (PLASTER) 10" BOTTOM RAIL W/ ADA THRESHOLD 10" BOTTOM RAIL W/ ADA THRESHOLD GARAGE DOOR GARAGE DOOR GARAGE DOOR 1 FIXED, 2 SLIDING PER SIDE 1 FIXED, 2 SLIDING PER SIDE GARDEN DOOR TO SWING INTO HALLWAY TYPE A TYPE B TYPE C TYPE D TYPE E TYPE F VIEW OPERATION PIVOT SWING SWING INT. SWING EXT. SWING EXT. ROLL-UP DOOR TYPE G TYPE H TYPE I TYPE J TYPE K TYPE L TYPE M EXT. SWING EXT. DOUBLE SWING INT. SWING EXT. SLIDING EXT. PIVOT EXT. SWING INT. SWING DOOR 1 HARDWARE SCHEDULE HARDWARE GROUP FUNCTION MANUFACTURER MODEL FINISH NOTES 2 3 4 5 ENTRY PASSAGE PRIVACY COVER PANEL GARAGE TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TYPE A B C D VIEW OPERATION FIX FIX FIX FIX WINDOW LEGEND WINDOW SCHEDULE STORY 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 1ST FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR 3RD FLOOR GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF GARDEN ROOF LOCATION OFFICE OFFICE RETAIL RETAIL RETAIL RETAIL RETAIL OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE TYPE C C A D D D D B B B B B B B B B B B B B B B B B B B B B B B B B B B B B ID 110.A 111.A 101.A 101.B 104.A 105.A 105.B 301.A 303.A 303.B 303.C 304.A 305.A 306.A 308.A 309.A 309.B 310.A 314.A 315.A 317.A 317.B 317.C 318.A 318.B 308.B 310.B 311.A 311.B 311.C 316.A 316.B 316.C 320.A 320.B 323.A UNIT SIZE 7'-0"×2'-8" 6'-11 3/4"×2'-8" 15'-8"×13'-3" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 21'-0"×15'-2 1/2" 5'-4 3/4"×8'-9 1/2" 14'-11 3/4"×9'-0" 24'-4"×8'-9 1/2" 14'-11 3/4"×8'-9 1/2" 12'-0"×8'-9 1/2" 3'-3 1/2"×8'-9 1/2" 4'-3 1/2"×8'-9 1/4" 7'-8 1/4"×8'-9 1/4" 9'-1/2"×8'-9 1/2" 12'-3 1/2"×3'-9 1/4" 1'-4 1/4"×8'-9 1/2" 12'-7 3/4"×8'-9 1/2" 10'-9 1/2"×8'-9 1/2" 10'-5 1/4"×8'-9 1/2" 11'-11 1/2"×8'-9 1/2" 10'-5 1/4"×8'-9 1/2" 15'-8"×8'-9 1/2" 15'-8"×8'-9 1/4" 10'-9 3/4"×3'-9 1/4" 12'-2"×3'-9 1/4" 5'-3"×6'-9 1/4" 16'-4 1/2"×6'-9 1/2" 16'-3 3/4"×6'-9 1/2" 9'-1 1/4"×6'-9 1/4" 7'-1/4"×6'-9 1/4" 11'-4 1/2"×6'-9 1/4" 3'-0"×6'-9 1/4" 7'-1"×6'-9 1/4" 4'-9 1/2"×6'-10" Nominal Surface Area 18.67 18.63 207.64 319.55 319.55 319.55 319.55 47.43 134.82 213.93 131.70 105.41 28.96 37.69 67.35 79.51 46.32 11.95 111.23 94.88 91.72 105.13 91.72 137.73 137.40 40.75 45.84 35.60 111.20 110.85 61.64 47.52 77.08 20.29 48.00 32.70 MODEL <Undefined> N/A N/A N/A N/A N/A <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> UNDEFINED <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> MANUFACTURER ARCADIA ARCADIA CUSTOM CUSTOM CUSTOM CUSTOM CUSTOM ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA <Undefined> ARCADIA ARCADIA <Undefined> <Undefined> <Undefined> <Undefined> ARCADIA ARCADIA FRAME MAT. HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM HM FRAME FINISH OPERATION FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX FIX HW SET REMARKS SCALE: 1' = 1'-0"2 DOOR SCHEDULE SCALE: 1' = 1'-0"1 HARDWARE SCHEDULE SCALE: 1' = 1'-0"3 WINDOW SCHEDULE TRASH ROOM RESTROOM CORRIDOR Page 215 of 324 EXHIBIT “A1” EXISTING LEGAL DESCRIPTION: (APN 4187-003-028) LOTS 25, 26, AND 27, BLOCK 10, HERMOSA BEACH TRACT, IN THE CITY OF HERMOSA BEACH, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 1, PAGES 25 AND 26 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. Page 216 of 324 NOT TO SCALENORTH 86.2'95'86.2'95'10TH COURT 9TH STREET HERMOSA AVENUEBEACH DRIVE58 10TH COURT APN 4187-003-027 LOT 24 LOT 25 LOT 26 LOT 27 EXHIBIT "A2" EXISTING 30'26.2'30' 30'26.2'30' NOT - A - PART NOT - A - PART PARCEL A 901 HERMOSA AVENUE APN: 4187-003-028 (EXISTING & PROPOSED) 50' 50'10'10'10'2 0'10'2 0'30'30'6 0'30'30'6 0'AREA = 8,189 SF Prepared By: Denn Engineers - Gary J. Roehl R.C.E. No. 30826, Expires: March 31, 2025 Owner: Cardinal Investments, Kyle Ransford Address: 901 Hermosa Avenue, Hermosa Beach Legal Description: Lot 25, 26 & 27, Block 10 Map of Hermosa Beach M.B. 1-25-26 APN: 4187-003-028 Page 217 of 324 EXHIBIT “B1” PROPOSED LEGAL DESCRIPTION: LOTS 25, 26, AND 27, BLOCK 10, HERMOSA BEACH TRACT, IN THE CITY OF HERMOSA BEACH, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 1, PAGES 25 AND 26 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. Page 218 of 324 NOT TO SCALENORTH 86.2'95'86.2'95'10TH COURT 9TH STREET HERMOSA AVENUEBEACH DRIVE58 10TH COURT APN 4187-003-027 LOT 24 LOT 25 LOT 26 LOT 27 EXHIBIT "B2" PROPOSED 30'26.2'30' 30'26.2'30' NOT - A - PART NOT - A - PART PARCEL A 901 HERMOSA AVENUE APN: 4187-003-028 (EXISTING & PROPOSED) 50' 50'10'10'10'2 0'10'2 0'30'30'6 0'30'30'6 0'AREA = 8,189 SF Prepared By: Denn Engineers - Gary J. Roehl R.C.E. No. 30826, Expires: March 31, 2025 Owner: Cardinal Investments, Kyle Ransford Address: 901 Hermosa Avenue, Hermosa Beach Legal Description: Lot 25, 26 & 27, Block 10 Map of Hermosa Beach M.B. 1-25-26 APN: 4187-003-028 Page 219 of 324 901 HERMOSA AVENUE HISTORIC RESOURCES ASSESSMENT HERMOSA BEACH, CALIFORNIA [24017] PREPARED FOR 901 HERMOSA PARTNERS LLC April 17, 2024 Page 220 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL i April 17, 2024 TABLE OF CONTENTS I. INTRODUCTION ................................................................................................................................. 1 Methodology ................................................................................................................................................... 2 Summary of Findings ..................................................................................................................................... 3 II. EXISTING HISTORIC STATUS ............................................................................................................. 4 National Register of Historic Places ............................................................................................................. 4 California Register of Historical Resources ................................................................................................. 4 California Historical Resource Status Codes ............................................................................................... 4 Hermosa Beach Landmarks .......................................................................................................................... 5 2017 City of Hermosa Beach General Plan Update ................................................................................... 6 III. PROPERTY DESCRIPTION ................................................................................................................ 8 Building Description ....................................................................................................................................... 9 Site Features .................................................................................................................................................. 15 Surrounding Neighborhood ........................................................................................................................ 15 IV. HISTORIC CONTEXT ....................................................................................................................... 17 Hermosa Beach History ............................................................................................................................... 17 Automotive Retailing and Repair (1915 – 1930) ....................................................................................... 21 V. SITE HISTORY .................................................................................................................................. 24 Site Development ......................................................................................................................................... 24 Construction Chronology......................................................................................................................... 27 Ownership and Occupant History .............................................................................................................. 28 Select Owner and Occupant Biographies .............................................................................................. 29 VI. EVALUATION .................................................................................................................................. 31 National Register of Historic Places ........................................................................................................... 31 California Register of Historical Resources ............................................................................................... 32 Hermosa Beach Landmarks ........................................................................................................................ 34 Integrity ...................................................................................................................................................... 36 California Environmental Quality Act (CEQA) ............................................................................................ 39 Status as a Historical Resource under CEQA ........................................................................................ 39 VII. CONCLUSION ................................................................................................................................ 41 VIII. REFERENCES ................................................................................................................................. 42 IX. APPENDICES ................................................................................................................................... 44 Appendix A – Preparer Qualifications ........................................................................................................ 44 Appendix B – 2014 DPR Form for 901 Hermosa Avenue ........................................................................ 45 Page 221 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 1 April 17, 2024 I. INTRODUCTION This Historic Resource Assessment (HRA) has been prepared at the request of the City of Hermosa Beach for property owners 901 Hermosa Partners LLC to evaluate the potential historic significance of the property at 901 Hermosa Avenue (APN# 4187-003-028) in Hermosa Beach, California (Figure 1). The building sits on the west side of Hermosa Avenue, the city’s main commercial corridor, and is bordered by 10th Court to the north and 9th Street to the south. (Figure 2). 10th Court is a driving street while 9th Street is a pedestrian only walking street. The property has a high-bay, one-story, 7,780-square-foot commercial building with a rectangular footprint. Designed in a commercial vernacular style with modest references to the Mission Revival style, it was erected in 1922 as an automobile showroom and repair facility for Lincoln, Ford, and Fordson vehicles by business owner George L. Stiles. The former showroom area, facing Hermosa Avenue, has since been subdivided to accommodate smaller retail businesses. The former repair area, comprising the west side of the building behind the showroom, has been subdivided with a mezzanine to serve as a storage facility. Figure 1: The location of the subject property is shaded red. Source: Los Angeles County office of the Assessor. Edited by Page & Turnbull. Page 222 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 2 April 17, 2024 Figure 2: Aerial view of 901 Hermosa Avenue, the subject property outlined in red. Source: Google Earth 2024. Edited by Page & Turnbull. This report provides an examination of the current historic status for 901 Hermosa Avenue, as well as a property description; historic contexts for Hermosa Beach and early twentieth century automobile retailing; a site history; and a biography for the developer and first owner for the subject property. The report also includes an evaluation of the building’s eligibility for individual listing in the National Register of Historic Places (National Register), the California Register of Historical Resources (California Register), and as a Hermosa Beach Landmark. The 2017 Hermosa Beach General Plan Update identified 901 Hermosa Avenue as a potential local historic resource with a California Historical Resource Status Code of 5S3 (appears to be individually eligible for local listing or designation through survey evaluation) and as a representative example of a 1920s commercial building.1 It appears that the property has not previously been evaluated for eligibility for listing in the National Register or the California Register as an individual property or as a contributor to an eligible district. Methodology Page & Turnbull staff prepared this report using research collected at various local repositories including the Los Angeles County Hermosa Beach Library and the Hermosa Beach Historical Society. Online resources included the Los Angeles County Office of the Assessor Property Assessment Information System for property information, the Los Angeles County Public Works Land Records 1 PCR Services, “7.0 Cultural Resources, Technical Background Report,” in 2017 City of Hermosa Beach PLAN Hermosa, August 2017, 7-20, 7-21, 7-29. Page 223 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 3 April 17, 2024 Information portal for historic tract maps, the Los Angeles Public Library Collection for digital Sanborn maps, HistoricAerials.com, Newspapers.com, and Ancestry.com. Page & Turnbull staff submitted a public record request to the City of Hermosa Beach for building permits and to the Los Angeles County Assessor for property records; these provided information on construction and alterations to the property and on past ownership from approximately 1946 through 2023. Historical narratives chronicling the development of Hermosa Beach reference the historic context in the 2017 Hermosa Beach General Plan.2 The current building owner, 901 Hermosa Partners LLC, provided Page & Turnbull staff with a Phase 1 Environmental Site Assessment Report prepared by Partner Engineering and Science, Inc. for the subject property in July 2022.3 This document provided historic owner and occupant information that supplemented Page & Turnbull staff research. Page & Turnbull staff conducted a site visit 901 Hermosa Avenue January 31, 2024. All photographs within this report were taken at that time, unless otherwise noted. Summary of Findings 901 Hermosa Avenue is not currently listed on any local, state, or federal register of historic resources. The property was previously identified as potentially eligible for local landmark designation in a 2014 windshield survey, and it is Page & Turnbull’s professional opinion that the property does appear to be eligible for local listing as a Hermosa Beach Landmark under Hermosa Beach Criterion C (Architecture) as a local example of a 1920s automobile showroom that is also one of the few remaining early commercial buildings in Hermosa Beach. This Historic Resource Assessment finds that the property does not appear to be individually eligible for listing in the National Register or California Register. Per California Environmental Quality Act (CEQA) Guidelines (14 CCR § 15064.5(a)), as 901 Hermosa Avenue is not currently listed in a local register of historic resources or in the California Register, and is not eligible for listing in the California Register, the property is not a historic resource for the purposes of the CEQA.4 2 PCR Services, “7.0 Cultural Resources, Technical Background Report,” in 2017 City of Hermosa Beach PLAN Hermosa, August 2017, 7-3 to 7-16. 3 Partner Engineering and Science, Inc., Phase 1 Environmental Site Assessment Report, 901 Hermosa Avenue, Prepared for Powerscourt Partners LLC, July 22, 2022. 4 Guidelines for Implementation of the California Environmental Quality Act (CEQA Guidelines), California Code of Regulations (CCR), Title 14 § 15000 et seq. Page 224 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 4 April 17, 2024 II. EXISTING HISTORIC STATUS The following section examines the national, state, and local historic status currently assigned to the commercial building at 901 Hermosa Avenue. National Register of Historic Places The National Register of Historic Places (National Register) is the nation’s most comprehensive inventory of historic resources. The National Register is administered by the National Park Service and includes buildings, structures, sites, objects, and districts that possess historic, architectural, engineering, archaeological, or cultural significance at the national, state, or local level. The subject property is not listed in the National Register of Historic Places individually, or as part of a registered historic district. California Register of Historical Resources The California Register of Historical Resources (California Register) is an inventory of significant architectural, archaeological, and historical resources in the State of California. Resources can be listed in the California Register through a number of methods. State Historical Landmarks and National Register-listed properties are automatically listed in the California Register. Properties can also be nominated to the California Register by local governments, private organizations, or citizens. The evaluative criteria used by the California Register for determining eligibility are closely based on those developed by the National Park Service for the National Register of Historic Places. The subject property is not listed in the California Register of Historical Resources individually, or as part of a registered historic district. California Historical Resource Status Codes Properties listed or under review by the State of California Office of Historic Preservation are listed within the Built Environment Resource Directory (BERD) and are assigned a California Historical Resource Status Code (Status Code) of “1” to “7” to establish their historical significance in relation to the National Register of Historic Places (National Register) or California Register of Historical Resources (California Register).5 Properties with a Status Code of “1” or “2” are either eligible for listing in the California Register or the National Register, or are already listed in one or both of the registers. Properties assigned Status Codes of “3” or “4” appear to be eligible for listing in either 5 California State Office of Historic Preservation, Built Environment Resource Directory (BERD), Los Angeles County, updated September 2022. Page 225 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 5 April 17, 2024 register, but normally require more research to support this rating. Properties assigned a Status Code of “5” have typically been determined to be locally significant or to have contextual importance. Properties with a Status Code of “6” are not eligible for listing in either register. Finally, a Status Code of “7” means that the resource has not been evaluated for the National Register or the California Register or needs reevaluation. 901 Hermosa Avenue is not currently listed in the BERD database for Los Angeles County with a status code. This means the property has not been formally evaluated using California Historical Resource Status Codes and submitted to the California Office of Historic Preservation. The most recent update to the BERD database was in September 2022. 6 Hermosa Beach Landmarks The City of Hermosa Beach adopted a Historical Resources Preservation Ordinance in 1998 (Municipal Code Chapter 17.53). The ordinance is intended to identify and ensure the long-term protection and use of historic resources that reflect special elements of the City’s architectural, artistic, cultural, historical, political, and social heritage. A historic resource must be at least 50 years old, or at least 30 years old if the City Council determines it is exceptional or threatened by demolition, removal, relocation, or inappropriate alteration. Nomination of a historic resource as a landmark is made by the City or by application of the property owners. The ordinance has a Certificate of Appropriateness process for alterations, restorations, demolitions, removal, or relocation of any interior or exterior features for landmark or potential landmark properties. Potential landmark properties are those on a list of historic resources established by City Council being considered for landmark status. Designated landmarks can benefit from certain incentives, such as the Mills Act program, and the State Historic Building Code. As of February 2024, four buildings have been designated or identified for protection under the City’s Historic Resources Preservation Ordinance: • The Bijou Theater, a 1923 theater at 1229-1235 Hermosa Avenue, as a local landmark; • The Hermosa Beach Community Center, a 1939 Art Deco complex at 710 Pier Avenue originally built as a school, as a local landmark; • Bank of America building at 90 Pier Avenue as a potential landmark warranting further study; and 6 California Office of Historic Preservation. Technical Assistance Bulletin No. 8: User’s Guide to the California Historical Resource Status Codes & Historic Resources Inventory Directory (Sacramento: California Office of State Publishing. November 2004). Page 226 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 6 April 17, 2024 • Hermosa Hotel at 710 Pier Avenue as a potential landmark warranting further study.7 901 Hermosa Avenue is not currently listed as a Hermosa Beach Landmark. 2017 City of Hermosa Beach General Plan Update The 2017 Hermosa Beach General Plan Update incorporates the results of a 2014 windshield survey of approximately 3,600 Hermosa Beach properties that were over 45 years old at that time (2014 survey). Based solely on their architecture, the survey identified about 220 potential historic and cultural resources, including residential and commercial buildings, public facilities, and landscape features such as parks and walk streets closed to vehicular traffic. Among the resources were 14 one- to three-story commercial buildings dispersed throughout the city, including several in the area around Pier Plaza and south to 9th Street. These vary in style from brick utilitarian to beach cottage, Mission Revival, Renaissance Revival, Midcentury Modern, New Formalist, and roadside vernacular. They do not comprise a coherent district by location or type. Each potentially eligible resource was documented with a Department of Parks and Recreation (DPR) 523A (Primary Record) form. Each of these resources that was found to be potentially eligible for individual local listing or designation through survey evaluation was given status codes of “5S3.” However, the 2014 windshield survey did not conduct property-specific historic research on the identified properties, and no DPR 532B (Building, Structure, Object) evaluation forms were prepared. As such, the surveyed properties were expected to require additional research and evaluation as historic resources for the purposes of CEQA review. The 2014 windshield survey was not submitted to the California Office of Historic Preservation (OHP) or State Historic Resources Inventory and DPR 523B evaluation forms were not prepared; as such, the survey does not meet the requirements of Public Resources Code (PRC) Section 5024.1(g) as it relates to the thresholds for historical resources for the purposes of CEQA.8 Based on this 2014 windshield survey, the 2017 Hermosa Beach General Plan Update identified 901 Hermosa Avenue as a potential local historic resource with a California Historical Resource Status Code of 5S3 (appears to be individually eligible for local listing or designation through survey evaluation) as a representative example of a 1920s commercial building (Appendix B).9 7 “Historic Resources,” City of Hermosa Beach, accessed February 15, 2024, https://www.hermosabeach.gov/our- government/city-departments/community-development/historic-resources. 8 CEQA Guidelines, 14 CCR § 15064.5. 9 PCR Services, “7.0 Cultural Resources, Technical Background Report,” in 2017 City of Hermosa Beach PLAN Hermosa, August 2017, 7-20, 7-21, 7-29. Page 227 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 7 April 17, 2024 Page 228 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 8 April 17, 2024 III. PROPERTY DESCRIPTION The property at 901 Hermosa Avenue is a rectangular parcel that contains a high-bay one-story, 7,780-square-foot commercial building built in 1922 (Figure 3). The building occupies the majority of its flat site which measures approximately 115 feet in width and 86 feet in depth. The east side of the building faces, and is set back from, Hermosa Avenue behind a pedestrian sidewalk; its north side is built out to the site perimeter at 10th Court; its west side faces a narrow, concrete-paved pedestrian alley and a two-story apartment building at 58 10th Court; its south side is set back approximately twenty feet from 9th Street and faces onto a concrete-paved strip that historically served as a driveway. The property boundary on the south side is defined by a low curb that separates the driveway from the street. Figure 3: Aerial view of 901 Hermosa Avenue, outlined in red. Source Google Earth 2024. Edited by Page & Turnbull. Page 229 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 9 April 17, 2024 Building Description 901 Hermosa Avenue is occupied by a high-bay, one-story wood-frame building with box-like massing and a rectangular footprint except at its southeast corner where the façade is angled at forty-five-degrees (Figure 4). The design of the building is typical of one-part vernacular commercial construction that provides a sizable wall area between windows and cornice for signage, a feature that also makes the façade appear larger.10 The subject property’s stucco finish and arched window openings modestly reference the Mission Revival style popular in 1920s Southern California. Figure 4: Primary (east) façade of 901 Hermosa Avenue, view northwest. The subject property has a combination of flat and projecting truss roof forms, covered with asphalt- coated rolled roofing, which are hidden behind a combination stepped and flat parapet. The stepped section of the parapet wraps the building’s primary (east) façade and continues onto the east ends of the north and south façades. The building’s undecorated stucco walls are painted. Fenestration includes punched arched openings with recessed, wood-framed, multi-light display windows, and rectangular steel-framed garage door openings. Each three-part display window is framed with tall lower panes surmounted by an arched upper transom. The lower panes and their wood frames and thin mullions are non-original in each opening. The transoms are generally original, featuring a centered row of narrow vertical panes flanked by arched corner fanlights; some 10 Richard Longstreth, The Buildings of Main Street (Washington DC: Preservation Press, 1987), 54-65. Page 230 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 10 April 17, 2024 of the central sashes have been replaced. The rectangular garage openings at the side facades have metal roll-up doors. The overall building massing is organized as three bays. A narrow rectangular bay with a flat roof along the east front of the building is oriented north-south and contains the former showroom, which is currently used as retail spaces. Behind the front bay, to the west, are two adjacent rectangular bays; these contain the former auto repair area, which has been retrofitted to serve as storage space. These rear bays have projecting wood truss roofs. The north side of the south bay’s roof is straight rather than sloped; though currently covered, it is likely this face served as a glazed clerestory for natural daylighting. Primary (East) Façade The primary (east) facade consists of two parts: the main storefront parallel to Hermosa Avenue and an angled southeast façade at the corner. The southeast and east-facing façades have stepped parapets (Figure 5). Figure 5: Primary façade (right) and southeast angled corner façade (left), view northwest. The angled southeast corner wall features a triangular wood-framed canopy over a single-panel entry door flanked by square, fixed wood-frame windows (Figure 6 and Figure 7). The long edge of the canopy is attached to the angled wall and its southeast corner is supported by a wood-encased round metal column seated on a round concrete base. The fenestration is situated on the north Page 231 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 11 April 17, 2024 (right) half of the wall, where its perimeter is surrounded with horizontally-layered tree branch segments that form a rustic frame. Figure 6: Southwest corner, view west. Figure 7: Southwest corner, view north. Figure 8: East façade, view northwest Figure 9: East façade, view southwest The storefront portion of the primary façade has three window bays, each with an arched opening and multi-light display window (Figure 8 and Figure 9). The middle section of the south (left) transom has been subdivided to accommodate a new center mullion flanked by metal-frame single- light sliding windows. The center window retains its original configuration except for new paired metal-frame entry doors. The north (right) window retains its original configuration. A small number of transom lites have been replaced with new glass. Sign boards are attached to the wall above the center of each window opening. Page 232 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 12 April 17, 2024 North Façade The north façade is organized in three sections, the east and center of which are located beneath the stepped parapet (Figure 10 and Figure 11). The east (left) section features a typical arched display window; the center section of its transom has been covered with an opaque panel. The middle section of the façade is penetrated by a rectangular garage door opening with concrete wheel guards at its base. The long, west (right) section has an infilled rectangular opening at its center; its proportions suggest that it was formerly a second garage door. A single metal panel door is located at the far west end. Figure 10: North façade, view southwest. Figure 11: North façade, view southeast. Page 233 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 13 April 17, 2024 Rear (West) Façade The west façade currently has no openings. Five recessed stucco panels, evenly arranged across the center of the wall plane, are infilled former window openings (Figure 12). Figure 12: Rear (west) elevation, view south. Page 234 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 14 April 17, 2024 South Façade The south façade is organized in two sections, which are located to the west of the angled southwest corner wall (Figure 13 and Figure 14). The west (left) section of the façade has a large rectangular plaster patch covering an infilled window opening. The center of the wall currently features a metal- framed three-part fixed and sliding window with an interior security grille. The window is framed with a simple painted wood surround (Figure 13). The east section has stepped parapet and is penetrated by a wide garage door opening with concrete wheel guards at its base and a cloth awning above. The opening has been subdivided to accommodate a single panel entry door with a glass-block transom on its west side and a smaller rolling security door on its east side (Figure 14). Figure 13: South façade, view northwest. Figure 14: South façade, east end, view north. Page 235 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 15 April 17, 2024 Site Features The curb between the public sidewalk and Hermosa Avenue at the southwest front of the property features a long curb cut, which formerly allowed vehicle access. The open area along the south property boundary is paved with scored concrete and separated from the adjacent walking street by a raised curb. Both site features indicate that this area was formerly used as a driveway to access the zone under the canopy and the garage door (Figure 15). The area is now used as a seating area with outdoor furniture and potted plants. Figure 15: Streetside curb cut, curb, and driveway, view west. Surrounding Neighborhood The neighborhood surrounding 901 Hermosa Avenue is a mix of property types and uses. Hermosa Avenue to the north and south of the subject property is a Main Street-type commercial thoroughfare that was once a streetcar route (Figure 16 and Figure 17). Properties along Hermosa Avenue are primarily one- and two-story commercial buildings, most of which are from the mid- to early twenty-first century. Two- and three-story commercial buildings are located directly across Hermosa Avenue from the subject property. Several 1920s-era commercial buildings remain on the street, including a former automobile repair building one-half block south of the subject property at 832 Hermosa Avenue, identified as potentially historic in the 2017 General Plan.11 Also nearby, 11 PCR Services, “7.0 Cultural Resources, Technical Background Report,” in 2017 City of Hermosa Beach PLAN Hermosa, August 2017, 7-21. Page 236 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 16 April 17, 2024 around Pier Avenue and Hermosa Avenue, are three of the four buildings receiving protection under the City’s Historic Resources Preservation Ordinance: the former Bijou Theatre that is now a Chase bank and retail store, the Bank of America Building, and the Hermosa Hotel. Figure 16: Typical commercial buildings along Hermosa Avenue, view north. Figure 17: Typical commercial buildings along Hermosa Avenue, view south. The blocks along 9th Street and 10th Court between Hermosa Avenue and Beach Drive are primarily residential with early one-story beach bungalows, mid- and late-twentieth century single-family residences and two-story apartment buildings (Figure 18 and Figure 19). Figure 18: Typical residential buildings along 9th Street, view west. Figure 19: Typical residential buildings along 10th Court, view west. Page 237 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 17 April 17, 2024 IV. HISTORIC CONTEXT Hermosa Beach History Hermosa Beach is one of a string of beach cities in the southwest corner of Los Angeles County. 12 Prior to the founding of Hermosa Beach, the area was part of Rancho Sausal Redondo. Granted to Antonio Ignacio Avila in 1822 during the Mexican era, Rancho Sausal Redondo encompassed over 22,000 acres. It extended along the coast from present-day Marina del Rey south to Redondo Beach and east to Inglewood and Lawndale. Avila’s ownership of the land was upheld in the transition to United States rule after the Mexican-American War ended in 1848, but his heirs sold the rancho lands after Avila’s death in 1858. A Scottish baron, Robert Burnett, purchased Rancho Sausal Redondo and the adjacent Rancho Aguaje de la Centinela in the 1860s.13 In the 1870s, Canadian Daniel Freeman and his wife, Catherine, leased both ranchos where they grew barley and grazed sheep; the Freemans purchased the land in 1885.14 Freeman started to sell parts of the rancho and, in 1900, the Hermosa Land and Water Company purchased 1,500 acres of the former rancho. Railway barons Moses Sherman and Eli Clark started the Hermosa Land and Water Company in anticipation of a resort settlement at the coast and growth from the City of Los Angeles. The land was surveyed in 1901 starting with Santa Fe Avenue (now Pier Avenue) running from the Santa Fe Railroad (at today’s Valley Drive) to the beach. The survey also laid out a boardwalk along the beach (now The Strand), while Hermosa Avenue, the second thoroughfare, ran parallel to the beach. In 1901, the original Hermosa Beach tract was subdivided between the boardwalk and Hermosa Avenue. Numbered streets started with 1st Street at the south and extended north; Santa Fe Avenue corresponded to 12th Street. The “First Addition to Hermosa Beach” was surveyed later in 1901, extending north to 26th Street and east to Loma Drive. The “Second Addition” was surveyed in 1902 and extended east from Loma Drive to the eastern border just beyond present day Prospect Avenue. The rapid pace of surveying and subdividing meant that residential development was sporadic in the first few decades. As a beach resort, Hermosa Beach was initially a seasonal community with a small permanent population that attracted many visitors on the weekends and in the summer.15 In 1904, the first Hermosa Beach Pier was constructed of wood. By 1906, Hermosa Beach had a population of around 300 people and only a few public buildings existed: a post office, schoolhouse, grocery, 12 Unless otherwise cited, this section is summarized from the PCR Services, “7.0 Historic Resources.” Hermosa Beach General Plan Updated, 2014; and Chris Miller, Jerry Roberts, and Hermosa Beach Historical Society, Images of America: Hermosa Beach (Charleston, SC: Arcadia Publishing, 2005). 13 Lorietta Louise Scheerer, “The History of the Sausal Redondo Rancho” (MA Thesis, University of Southern California, 1938), 20. 14 Scheerer, “The History of the Sausal Redondo Rancho,” 22-3. 15 Patricia A. Gazin, Footnotes on the Sand (Hermosa Beach: Myron Gazin, 1991), 10. Page 238 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 18 April 17, 2024 general store, and a few boarding houses.16 In January 1907, Hermosa Beach incorporated as the nineteenth city in Los Angeles County. Figure 20: Late 1910s photograph of the corner of Santa Fe (now Pier) Avenue and Hermosa Avenue, looking northwest. Source: Roger Creighton in Images of America: Hermosa Beach. Greater growth would come with the arrival of the Pacific Electric rail line (Figure 20). By 1910, Hermosa Beach was a stop on the Pacific Electric’s “Balloon Route Excursion” that ran along Hermosa Avenue. The train brought more tourists and potential new residents to the beach community. The Berth family built the first hotel at 10th Street and the Strand in 1907. The new city spent thousands of dollars on street and lighting improvements to attract new residents. Many of the early residences were summer homes for those in Los Angeles and Pasadena.17 Most of the housing stock was the vernacular beach cottages or bungalows that could be built for a modest amount. Development was denser near the coast and toward the southern end of the city, though even in the 1920s, many blocks had several undeveloped lots. In the hills inland, Greek and Japanese farmers grew carnations, chrysanthemums, and other flowers (Figure 21).18 16 Scheerer, “The History of the Sausal Redondo Rancho,” 28. 17 Gazin, Footnotes on the Sand, 17, 26. 18 Gazin, Footnotes on the Sand, 16-17. Page 239 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 19 April 17, 2024 Figure 21: Map of Hermosa Beach in 1915 with concentrated development near the coast and scattered elsewhere. The approximate location of 901 Hermosa Avenue is marked with a red dot. Source: Hermosa Beach Historical Society in Images of America: Hermosa Beach. In 1913, the city approved plans to replace its wood boardwalk with a concrete “Strand.” That same year the extant wooden pier was replaced with a concrete pier. At the entrance of the new pier was a Mission Revival-style building (since demolished) with an archway that had an upper-level viewing deck (Figure 22).19 In 1917, the Hermosa Beach Bathhouse Company announced plans for a bathhouse at The Strand, just south of the pier. The Spanish Colonial Revival-style building provided a private place for beach visitors to change and store their belongings. Figure 22: Mission Revival-style building at entrance to the Hermosa Beach Pier, circa 1940, demolished 1960s. Source: Hermosa Beach Historical Society in Images of America: Hermosa Beach. 19 “Handsome Archway: Hermosa Beach Is Adding Decorative Additions to Its Pleasure Pier, Rest Rooms Provided,” Los Angeles Times, January 4, 1914. Page 240 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 20 April 17, 2024 With the economic boom of the 1920s, Hermosa Beach saw greater residential and commercial development, much of the expansion serving tourists (Figure 23). In 1923, the Surf and Sand Club announced plans for a clubhouse on The Strand located north of the pier, between 14th and 15th streets. Designed by prominent Southern California architect, Myron Hunt, the four-story building had a ballroom, indoor swimming pool, and 124 rooms with private bathrooms. The building became the Hermosa Biltmore Hotel (since demolished) in the 1930s. Also constructed in the 1920s was the Metropolitan (later Bijou) Theatre (extant, Hermosa Beach Landmark). Figure 23: View of storefronts along Pier Plaza, circa 1925. Source: Hermosa Beach Historical Society in Images of America: Hermosa Beach. Development in Hermos aBeach was modest during the Great Depression and World War II. Like much of Southern California, Hermosa Beach boomed in the post-World War II years. The lots near the ocean that had not yet been developed were finally infilled, while previously industrial and argicultural lands further inland were subdivided for new housing. A new civic center with a Modernist style city hall, police station, fire station, and library opened in 1962. Many of Hermosa Beach’s earliest notable buildings and features were demolished in the 1960s, including the arch and pavililon buildings at the pier entrance, the former Surf and Sand Club (Hermosa Biltmore Hotel), and the Pacific Eletric rail line. Page 241 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 21 April 17, 2024 Automotive Retailing and Repair (1915 – 1930) California’s early and rapid embrace of the automobile made it a pioneer in automobile ownership and retailing.20 The earliest automobile sales were conducted through livery stable, carriage dealer, or bicycle shops. Purpose-built auto dealerships emerged just before World War I, typically fitting into central retail districts with conventional storefronts, except for large entry doors and windows. By the late 1910s, sales facilities became more elaborate, and dealers frequently constructed impressive buildings in traditional styles with opulent sales salons to convey a reputable experience. Since most potential customers did not yet own automobiles, dealerships were located close to streetcar lines. Auto manufacturers were often corporate sponsors of the initial buildings; these sales rooms served as examples of the new form and distinctive quality manufacturers encouraged locally owned and built dealerships to emulate.21 In the early 1920s, urban dealerships began to combine auto servicing and repair with sales (Figure 24). This required the construction of larger, often multi-story, facilities with ramps and the volume to accommodate multiple vehicles. Façades continued to feature historicist detailing with the only feature identifying the buildings as auto service facilities being factory sash windows and vehicle- sized openings.22 Figure 24: 1050 Hope Street (Los Angeles) was built as a showroom and service center for the Willys-Overland Company in 1916 and served as such through 1932, photo circa 2015. Source: Survey-LA. 20 This section is adapted using relevant information from the Daniel Prosser and Daniel Herrick, “Commercial Development, 1850-1980: Commercial Development and the Automobile, 1910-1970” in Survey-LA Los Angeles Historic Resources Survey, Los Angeles Citywide Historic Context Statement, prepared for the City of Los Angeles Department of City Planning, August 2016. 21 Prosser and Herrick, “Commercial Development, “ 35-36. 22 Prosser and Herrick, “Commercial Development, “ 35-36. Page 242 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 22 April 17, 2024 Outlying business districts continued to build small single-story outlets on local main streets (Figure 25). The suburban showrooms adopted a common three-bay façade composition consisting of an elaborate center entrance with symmetrically flanking show windows placed directly on the street without setback. These were essentially single-story versions of the more elaborate central business district dealerships, and they maintained a footprint similar to that of an early livery stable. The suburban buildings typically adopted the period revival styles popular at the time.23 Figure 25: Former showroom and repair facility (Hollywood) built in 1925, photo circa 2015. Source: Survey-LA. By the 1930s, as many potential customers owned cars, there was no longer a need to be located close to streetcar lines. Instead, ease of access and adequate parking meant that the few new showrooms constructed during the Great Depression moved to outer arterial roads. The new facilities at these locations were typically designed with a showroom in the front, still positioned directly on the sidewalk without a setback, and service bays to the rear with generous perimeter parking and driveways. These buildings frequently adopted the new Streamline Moderne and Art Deco styles of the decade. After World War II, the showroom typology shrank in size in favor of larger parts and service departments. By the 1960s, automobile retailing shifted again to facilities in the far suburbs with on- site showrooms at the back of the lot used as offices and for display of select models, the buying experience focused instead on vast outdoor sales lots.24 These shifts meant that early automobile 23 Prosser and Herrick, “Commercial Development, “ 36. 24 Prosser and Herrick, “Commercial Development, “ 36-39. Page 243 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 23 April 17, 2024 retail buildings were quickly outdated. Some were repurposed for other uses. Some continued as brand-specific repair facilities, as satellite space for relocated dealerships, or as independent businesses providing a specialized automobile-related service. Many were demolished and early examples are increasingly rare. The Sanborn Map Company fire insurance map of Hermosa Beach (Sheet 15, January 1927 – September 1946) showed four automobile sales and repair businesses on Hermosa Avenue between Pier Avenue and Second Street in this period. Three were located opposite 901 Hermosa Avenue on the east side of the street. These included an auto sales and repair facility at 900-910 Hermosa Avenue (demolished), an auto repair facility at 832-842 Hermosa Avenue (extant and converted to co-working space), and an auto service business between them (demolished). These businesses were likely accessed from the rear alley, Palm Drive, or through the auto service business. The remaining building at 832-842 Hermosa Avenue was built in 1913 and represents the previous decade in automotive history when buildings for both retail and repair were industrial in character without the accommodation for auto circulation and display evident at 901 Hermosa Avenue built in 1922 (Figure 26). Figure 26: 832-842 Hermosa Avenue, built in 1913, circa 2022. Source: Google Street View. Page 244 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 24 April 17, 2024 V. SITE HISTORY Site Development The property at 901 Hermosa Avenue is located within the original Hermosa Beach tract that was surveyed and subdivided in 1901. The tract map for that year shows that lots 25, 26, and 27, which comprise the subject property, at the northwest corner of Ninth Street and Hermosa Avenue were part of the city’s original plan (Figure 27). Figure 27: 1901 Tract Map of Hermosa Beach. Source: Los Angeles County Public Works Land Records Information. Edited by Page & Turnbull. Page 245 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 25 April 17, 2024 According to historic Los Angeles County Assessor map books, the first improvement on 901 Hermosa Avenue occurred around 1922. No original building permit for the subject property is on file at the City of Hermosa Beach, and research has not identified the architect or builder. By late 1922, the parcel was owned by George L. Stiles. A newspaper article announced his construction of a $25,000 Lincoln–Ford–Fordson dealership and repair facility at the corner of Hermosa Avenue and 9th Street, stating it would be built of “brown stucco of the Mission type of architecture so appropriate for western landscapes.” 25 The article further noted that it would provide a larger floor space for Lincoln-Ford-Fordson products and repair than at other nearby dealers, and be open by November 1922. The accompanying rendering portrayed a building that is largely consistent with the appearance of 901 Hermosa Avenue in 2024, with overall massing fenestration, roof form, windows, and parapet intact (Figure 28). Figure 28: Proposed design of 901 Hermosa Avenue, October 1922. Source: “New $25,000 Lincoln – Ford – Fordson Agency at Hermosa Beach,” Redondo Reflex, October 13, 1922, 6. A 1927 Sanborn Map Company fire insurance map showed the footprint of the auto sales and repair building, including the angled façade and canopy. The map indicated that the building had a wood truss roof and concrete floor, and also showed the residential buildings to the west and commercial buildings along Hermosa Avenue (Figure 29). 25 “New $25,000 Lincoln-Ford-Fordson Agency at Hermosa Beach,” Redondo Reflex, October 13, 1922, 6. Page 246 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 26 April 17, 2024 Figure 29: Sanborn Map Company fire insurance map of Hermosa Beach, Sheet 15, January 1927 – September 1946. The location of the subject property is outlined in red. Source: Los Angeles Public Library. Edited by Page & Turnbull. Building permits indicated that, in 1946, the subject property was reroofed and that windows on the north and south of the building were plastered over in 1975. In 1986, the exterior was water blasted (likely meaning pressure washed) and the building was reroofed again in 1991 and in 2010. An interior stair and emergency fire exit were constructed in 1998; this was likely the exit door at the west end of the north façade. Assessor notes dated September 17, 1956 (added to a September 3, 1947 Los Angeles County Assessor Building Description Blank Form) indicate that the rear west wall had been converted to a firewall by that time. It is likely that the windows on the rear wall were infilled as part of this change. A comparison of the building rendering from 1922 with staff observations made during the Page & Turnbull site visit on January 31, 2024, reveals other visible alterations that are not recorded in building permits or assessor documentation. These changes include: replacement glazing in the Page 247 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 27 April 17, 2024 lower sections of the east façade windows and in the southeast façade windows; removal and enclosure of a door on the south half of the southeast façade; substitution of original wood panel doors on the south and north façades with metal rolling doors; and infill of a ribbon of windows at the west end of the south façade. Building permits and assessor records suggest that the building continued to serve automotive uses through the late 1960s before being converted to warehouse and general retail use. CONSTRUCTION CHRONOLOGY The following table provides the building permit information for construction activity at 901 Hermosa Avenue based on applications on file with the City of Hermosa Beach Planning Division. Cancelled and expired permits are not included. TABLE 1. PERMIT HISTORY FOR 901 HERMOSA AVENUE Date Filed Permit App. # Owner Contractor Work 1946 3963 Not listed Not listed Reroofing 1975 16370 John Haworth Not listed Plaster up existing windows on north and south of building 1976 16550 John Haworth Not listed Construct non-bearing partition wall 61’ x 12’ high with 3’ door dividing rear area 1977 Not listed John K. Haworth Not listed Interior partition walls 1980 Not listed Greg Dahle Not listed Remodel existing storage use 1986 20209 Greg Dahle Not listed Water blast building exterior 1987 20913 Greg Dahle Not listed Install awnings 1991 22214 Greg Dahle A-1 All American Roofing Remove roof and install three-ply cap roof 1997 Not listed Not listed Not listed Hermosa Fire Department letter noting no record of any permit for two level storage 1998 Not listed Gregg and Kay J. Dahle Not listed Add stairs and emergency fire exit 2010 Not listed Gregg and Kay J. Dahle Shoreline Roof Co. Apply four-layer built-up roof system over existing one-layer flat roof Page 248 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 28 April 17, 2024 Ownership and Occupant History The following tables provide a summary of the ownership and occupancy history of 901 Hermosa Avenue beginning with the year of construction, compiled from historic newspaper articles, building permits, and data in the Phase 1 Environmental Site Assessment Report (2022) prepared by Partner Engineering and Science, Inc..26 TABLE 2. OWNERSHIP HISTORY FOR 901 HERMOSA AVENUE Date(s) Owner(s) Occupation 1922- 1923 George L. Stiles Owner, Lincoln-Ford-Fordson Dealership and Garage 1923-1943 Unknown Unknown 1943–1980 John Haworth Owner, Haworth Chevrolet Company, auto parts warehouse and auto glass replacement service, other retail 1980-2022 Melvin Greg Dahle TABLE 3. OCCUPANT HISTORY FOR 901 HERMOSA AVENUE Date(s) Occupant(s) 1923 Hufford & Haggett Lincoln and Ford 1927 Haggett Lincoln Autos 1931-1936 Nelson & Stickney Autos 1939 Haworth Jones Chevrolet 1941-1954 Haworth Chevrolet Company Autos 1954 Butler Buick 1960 John Haworth 1968 John Haworth (auto parts warehouse and auto glass replacement service, other retail) 1971 Gene’s Restaurant Equipment, Sedillo Sheet Metal 1978 Cadene Ozzie, The First Time, The Grab Bag, TK & Company 1981 Dar Es Salam, Dial A Sign Inc, The Gazelle, Greenpeace Southern California, Iris Creation, Jamal Farida 1981-1985 Maya 1981-2024 Bay Self Storage 1985 Executive Communique, Intimate Impression, Maya, Murphy’s Graphics, SJ & Company, Studio 9, Tattiahas Original, Things Oriental, West Coast Plants, Word Magic, Write Now Computer 1985-1995 Bradford GM & Associates 1990 Champ Awards, Jim Searcy Glass Etching, South Bay Hng GA FU, Sun International, Treasure House, Universal Cash Register 1995 Inta Sport, Keppler Entertainment, Woods of Holly Glory 26 Partner Engineering and Science, Inc., Phase 1 Environmental Site Assessment Report, 901 Hermosa Avenue, prepared for Powerscourt Partners LLC, July 22, 2022, 8-9, 14. Page 249 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 29 April 17, 2024 Date(s) Occupant(s) 1995-2003 Antique Eddy’s 1995-2020 Grizzly Clothing 2003 Bearsmouth Entertainment, Meg Co 2003-2008 Let There Be Light 2003-2020 Meg Company 2008 Hermosa Hair Studio, Lucinda Messer Lecovin MD, Sol Baby 2008-2016 David Frederickson Law Office 2008-2024 Glow Hair & Skin Therapy, Ogden Photography 2012 Sole Searching 2012-2020 By Hand 2016 Hermosa Beadworks 2020 Lily Pad, Meg Co 2021-2024 Trick E-bikes SELECT OWNER AND OCCUPANT BIOGRAPHIES George Leslie Stiles (1880 – 1935) George Leslie Stiles was born in Buffalo, New York in 1880 and died in Los Angeles in 1935.27 By 1900, his family had relocated to Oklahoma City, Oklahoma, where George and his brother, Charles, worked at the family-run Stiles Floral Company, a wholesale florist and grower business established in 1899.28 George married Katherine Gran Jervey in Oklahoma City in 1912 and continued working at the floral company through early 1922.29 The business filed for bankruptcy in March of that year and, in June, George and Katherine moved to Los Angeles, likely to the community of Redondo Beach where directories placed them in 1925.30 Within months, George became an active member of the Hermosa Beach area Chamber of Commerce, chairing their membership committee and networking to bring new businesses to the city.31 In October 1922, the local newspaper announced Stiles’ construction of a $25,000 Lincoln-Ford- Fordson vehicle dealership and garage in Hermosa Beach, noting that sales were already underway and that the building would be ready for occupancy by mid-November 1922.32 His association with the new business was brief as, in July 1923, Stiles sold the dealership to the Hufford & Haggett 27 California United States Death Index 1880-1935, via Ancestry.com. 28 1900 United States Census, Oklahoma County, Oklahoma, digital image s.v. “George L. Stiles,” via Ancestry.com; and “Oklahoma City Pays $300,000 Annually To Say It With Flowers,” The Daily Oklahoman (Oklahoma City, OK), November 6, 1921, 9. 29 Oklahoma County Marriage Records 1889-1951 Book 19, 460, s.v. “George Leslie Stiles,” via Ancestry.com. 30 “Notice of First Meeting of Creditors,” The Daily Law Journal-Record (Oklahoma City, OK), March 9, 1922, 3; and Sadie Anderson, “Society,” Oklahoma City Times, June 16, 1922, 7. 31 “Agitate for Hotel,” Redondo Reflex, October 20, 1922, 11. 32 “New $25,000 Lincoln-Ford-Fordson Agency at Hermosa Beach,” Redondo Reflex, October 13, 1922, 6. Page 250 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 30 April 17, 2024 Lincoln and Ford company.33 By 1925, George and Charles Stiles, with partner John Zeller, took over an existing Hudson-Essex sales and repair business in Redondo Beach, forming Zeller-Stiles Motors.34 In 1927, Stiles moved to Pasadena and refocused his business interests on real estate. He worked for architect and developer Frank Meline as the manager for his Miramar Sales Corporation’s Miramar Estates in Santa Monica (now Castellammare in Pacific Palisades) and subsequently as a sales representative for a Chandler Improvement Company project to develop a winter resort in Arizona to be designed by architect John Byers.35 33 “Hermosa News,” Redondo Reflex, July 20, 1923, 5. 34 “Locates in Redondo,” Redondo Reflex, Jun12, 1925, 8. 35 “Completion of New Boulevard Lends Impetus,” Los Angeles Times, July 31, 1927,78; and “Winter Resort in Desert Will Be Cooperative,” Los Angeles Times, February 23, 1920, 62. Page 251 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 31 April 17, 2024 VI. EVALUATION National Register of Historic Places The National Register of Historic Places (National Register) is the nation’s most comprehensive inventory of historic resources. The National Register is administered by the National Park Service and includes districts, sites, buildings, structures, and objects significant in American history, architecture, archeology, engineering, and culture. These resources contribute to an understanding of the historical and cultural foundations of the Nation at the national, state, or local level. Typically, properties over fifty years of age may be eligible for listing in the National Register if they meet any one of the four significance criteria and if they retain sufficient historic integrity to convey that significance. However, properties under fifty years of age may be determined eligible if it can be demonstrated that they are of “exceptional importance.” Other criteria considerations apply to cemeteries, birthplaces, graves of historical figures, properties owned by religious institutions or used for religious purposes, structures that have been moved from their original locations, reconstructed buildings, and properties primarily commemorative in nature. National Register criteria are defined in depth in National Register Bulletin Number 15: How to Apply the National Register Criteria for Evaluation. The National Register has four basic criteria under which a property may be considered eligible for listing. It can be found significant under one or more of the following criteria. • Criterion A (Events): Properties associated with events that have made a significant contribution to the broad patterns of our history. • Criterion B (Person): Properties associated with the lives of persons significant in our past. • Criterion C (Architecture): Properties that embody the distinctive characteristics of a type, period, or method of construction, or that represent the work of a master, or that possess high artistic values, or that represent a significant distinguishable entity whose components lack individual distinction. • Criterion D (Information Potential): Properties that have yielded, or may be likely to yield, information important in prehistory or history. A property may be considered significant on a national, state, or local level to American history, architecture, archaeology, engineering, and culture. Page 252 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 32 April 17, 2024 California Register of Historical Resources The California Register of Historical Resources (California Register) is an inventory of significant architectural, archaeological, and historical resources in the State of California. Resources can be listed in the California Register through a number of methods. State Historical Landmarks and National Register-listed properties are automatically listed in the California Register. Properties can also be nominated to the California Register by local governments, private organizations, or citizens. The evaluative criteria used by the California Register for determining eligibility are closely based on those developed by the National Park Service for the National Register of Historic Places. In order for a property to be eligible for listing in the California Register, it must be found significant under one or more of the following criteria. • Criterion 1 (Events): Resources that are associated with events that have made a significant contribution to the broad patterns of local or regional history, or the cultural heritage of California or the United States. • Criterion 2 (Persons): Resources that are associated with the lives of persons important to local, California, or national history. • Criterion 3 (Architecture): Resources that embody the distinctive characteristics of a type, period, region, or method of construction, or represent the work of a master, or possess high artistic values. • Criterion 4 (Information Potential): Resources or sites that have yielded or have the potential to yield information important to the prehistory or history of the local area, California, or the nation.36 The following section examines the eligibility of 901 Hermosa Avenue for individual listing in the National Register and the California Register. CRITERION A/1 (EVENTS) 901 Hermosa Avenue does not appear eligible for listing in the National Register or California Register under Criterion A/1. 36 California Office of Historic Preservation, Technical Assistance Bulletin No. 7: How to Nominate a Resource to the California Register of Historical Resources (Sacramento: California Office of State Publishing, September 4, 2001), 11. Page 253 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 33 April 17, 2024 Research did not associate 901 Hermosa Avenue with any events that have made a significant impact in history. The building was built in 1922 and was among the group of early commercial buildings along Hermosa Avenue that arrived with the introduction of the Pacific Electric streetcar line in 1910 and the rise in automobile ownership. Although the streetcar increased access to Hermosa Beach, it was never a streetcar suburb of Los Angeles and remained a seasonal beach destination until after World War II. 901 Hermosa Beach does not appear to have played a unique or significant role in development of the Hermosa Avenue commercial corridor. CRITERION B/2 (PERSONS) 901 Hermosa Avenue does not appear eligible for listing in the National Register or California Register under Criterion B/2. The subject property was commissioned by George Stiles who owned the building for less than one year before selling. He appears to have been a serial entrepreneur whose next investment in a Redondo Beach automobile dealership was equally brief before he shifted his attention to real estate sales outside the beach cities area. Stiles lived in Hermosa Beach for only five years before moving to Pasadena. Research on his contributions to the city indicate that they did not rise above participation in various Chamber of Commerce activities. Stiles has no history as a leader or innovator in the automotive industry, the construction industry, or as an individual of note in shaping the new Hermosa Beach community. CRITERION C/3 (ARCHITECTURE) 901 Hermosa Avenue does not appear to be eligible for listing in the National Register or California Register under Criterion C/3. 901 Hermosa Avenue is a modest example of an early automobile showroom and repair facility, typical of those located on suburban main streets adjacent to streetcar lines in the 1920s. The subject property illustrates the simplest version of the building typology prevalent in outlying areas in the decade before California’s exploding car culture led to larger showrooms further from downtown areas. It features a characteristic single-story three-bay glazed façade composition. The subject property’s massing, with a stylized streetside showroom fronting a functional rear repair area, illustrates how this early typology complemented and functioned within a typical early twentieth century streetscape. Its siting, which accommodates a driveway, angled corner, and passage through the building for cars, reveals how this early architectural form was manipulated to accommodate automobile circulation. Like other automobile sales and service buildings of the period, its design references a popular local style of the era, Mission Revival; here, it is executed with less elaboration and ornamentation than on more high-style examples. Further, original features Page 254 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 34 April 17, 2024 such as side windows and doors have been replaced or infilled. No builder or architect was identified in the course of research, and the property does not possess high artistic value. The modest design of 901 Hermosa Avenue does not rise to the level of architectural distinction required for state or national eligibility under Criterion C/3. CRITERION D/4 (INFORMATION POTENTIAL) 901 Hermosa Beach does not appear to be eligible under Criterion 4 as a principal source of important construction-related information. The “potential to yield information important to the prehistory or history of California” typically relates to archeological resources, rather than built resources. When California Register Criterion 4 (Information Potential) does relate to built resources, it is relevant for cases when the building itself is the principal source of important construction-related information. Page & Turnbull’s evaluation of this property was limited to age-eligible resources above ground and did not involve survey or evaluation of the subject property for the purposes of archaeological information. Hermosa Beach Landmarks To be listed as a Hermosa Beach Landmark, a property must be at least 50 years old and meet one or more of the following criteria: A. It exemplifies or reflects special elements of the City’s cultural, social, economic, political, aesthetic, engineering, or architectural history; or B. It is identified with persons or events significant in local, state, or national history; or C. It embodies distinctive characteristics of a style, type, period, or method of construction, or is a valuable example of the use of indigenous materials or craftsmanship; or D. It is representative of the notable work of a builder, designer, or architect; or E. Its unique location or singular physical characteristic(s) represents an established and familiar visual feature or landmark of a neighborhood, community, or the City. A property that is at least 30 years old may become a Landmark if the City Council determines it is exceptional or threatened by demolition, removal, relocation, or inappropriate alteration. The following section examines the eligibility of 901 Hermosa Avenue for individual listing as a Hermosa Beach Landmark. Page 255 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 35 April 17, 2024 HERMOSA BEACH CRITERION A (SPECIAL ELEMENTS OF THE CITY’S HISTORY) 901 Hermosa Avenue does not appear to be eligible under Hermosa Beach Criterion A. Research did not show that the building played a role in Hermosa Beach’s cultural, social, political, or engineering history. It was one among many commercial establishments along Hermosa Avenue, including three auto sales and service businesses located directly across the avenue, that served the local community without making automotive services a significant economic generator for the city. The subject property is not an exceptional example of the Mission Revival aesthetic and does not contribute to the overall architectural history of Hermosa Beach. HERMOSA BEACH CRITERION B (PERSONS OR EVENTS) 901 Hermosa Avenue does not appear to be eligible under Hermosa Beach Criterion B. The original owner, George L. Stiles, appears to be a serial entrepreneur whose association with the subject property and Hermosa Beach was brief and uneventful. General research on subsequent owners did not reveal that any made contributions significant to local, state, or national history. Research did not connect the building to events of significance to local, state, or national history. HERMOSA BEACH CRITERION C (ARCHITECTURE) 901 Hermosa Avenue appears to be eligible under Hermosa Beach Criterion C. 901 Hermosa Avenue is one of the few remaining commercial properties that date to the early period of Hermosa Beach development and to the 1920s era of automobile retailing. It is an example of an increasingly rare early main street showroom and repair facility in an outlying town. Further, it exhibits site and architectural characteristics of a modest vernacular automotive building form specific to the 1920s, the transitional decade in which auto retailing discarded its previously industrial aesthetic and before it shifted to larger and more suburban facilities. It is distinct from the other remaining automotive building at 832 Hermosa Avenue that represents the industrial appearance associated with automobile service in the nineteen-teens. 901 Hermosa Avenue illustrates how automotive buildings fit into an early twentieth century commercial and streetcar setting, adjusted their form to meet the needs of automobile circulation, developed a distinctive appearance—single-story three-bay façade composition with an extensively glazed display in the front and service at the rear—to convey their business function, and asserted their status by adopting a current architectural style, here a minimal version of Mission Revival. The building continues to convey its original function, form, and aesthetic to illustrate the history of automobile and main street commercial retailing. While the property does not appear to rise to the level of significance for listing in the National Register or California Register, the property is a rare and Page 256 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 36 April 17, 2024 distinctive example of a former 1920s automobile showroom and repair facility in Hermosa Beach where very few early twentieth century commercial properties remain extant. HERMOSA BEACH CRITERION D (BUILDER OR ARCHITECT) 901 Hermosa Avenue does not appear to be eligible under Hermosa Beach Criterion D. Research did not uncover any information about a particular architect or builder associated with the building. HERMOSA BEACH CRITERION E (UNIQUE LOCATION OR SINGULAR PHYSICAL CHARACTERISTIC) 901 Hermosa Avenue does not appear to be eligible under Hermosa Beach Criterion E. While part of the City’s downtown commercial streetscape near the ocean and pier, the building has a modest scale. Its angled southeast façade, while a unique response to the need for automotive circulation and service, is not a singular physical characteristic that has made the building an established or familiar visual landmark in the neighborhood or city. INTEGRITY In order to qualify for listing in any local, state, or national historic register, a property or landscape must possess significance under at least one evaluative criterion as described above and retain integrity. Integrity is defined by the California Office of Historic Preservation as “the authenticity of an historical resource’s physical identity evidenced by the survival of characteristics that existed during the resource’s period of significance,” or more simply defined by the National Park Service as “the ability of a property to convey its significance.”37 In order to evaluate whether the subject property retains sufficient integrity to convey its historic significance, Page & Turnbull used established integrity standards outlined by the National Register Bulletin 15: How to Apply the National Register Criteria for Evaluation. Seven variables, or aspects, that define integrity are used to evaluate a resource’s integrity—location, setting, design, materials, workmanship, feeling, and association. A property must possess most, or all, of these aspects in 37 California Office of Historic Preservation, Technical Assistance Series No. 7: How to Nominate a Resource to the California Register of Historical Resources (Sacramento: California Office of State Publishing, September 4, 2001), 11; and National Park Service, National Register Bulletin 15: How to Apply the National Register Criteria for Evaluation (Washington, D.C.: U.S. Department of the Interior, National Park Service, 1995), 44. Page 257 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 37 April 17, 2024 order to retain overall integrity. If a property does not retain integrity, it can no longer convey its significance and is therefore not eligible for listing in local, state, or national registers. The seven aspects that define integrity are defined as follows: Location is the place where the historic property was constructed or the place where the historic event occurred; Setting addresses the physical environment of the historic property inclusive of the landscape and spatial relationships of the building(s); Design is the combination of elements that create the form, plan, space, structure, and style of the property; Materials refer to the physical elements that were combined or deposited during a particular period of time and in a particular pattern or configuration to form the historic property; Workmanship is the physical evidence of the crafts of a particular culture or people during any given period in history or prehistory; Feeling is the property’s expression of the aesthetic or historic sense of a particular period of time; and Association is the direct link between an important historic event or person and the historic property. LOCATION 901 Hermosa Avenue retains integrity of location. The subject property has not been moved from its original site. SETTING 901 Hermosa Avenue retains integrity of setting. Hermosa Avenue remains a commercial strip and both 9th Street and 10th Court continue to be residential. Although the scale and design of the surrounding properties has changed and the Pacific Electric streetcar line has been removed, these alterations, which are typical of commercial corridor development, have not dramatically altered the spatial relationship of 901 Hermosa Avenue to its setting. The building retains its spatial relationship with Hermosa Avenue, which was key to its original use for automobile service. Page 258 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 38 April 17, 2024 DESIGN 901 Hermosa Avenue retains integrity of design. The building continues to exhibit the original footprint, massing, roof form, fenestration, and parapet profile illustrated in the 1922 news article announcing its completion. It retains its position on the sidewalk without a setback, division into front and rear sections, three-bay façade composition, arched window openings, unique glazing pattern, and features reflecting automobile circulation such as service doors, driveway, canopy, and curb cut. Some alterations to the subject property were observed at the time of the site visit including the infill of side and rear windows. These changes are reversible and do not diminish the building’s essential qualities as a showroom and repair facility. MATERIALS 901 Hermosa Avenue retains integrity of materials. The original architectural palette of stucco cladding and glazing within arched openings is intact. Some alterations to the subject property were observed at the time of the site visit including the updating of some glazing, window frames, and doors, within original openings. New wood window framing for the lower units replicates the layout of the original; replaced glazing within the new frames replicates the original window pattern. Door replacement has occurred within original frames and does not detract from the original openings. These changes are reversible and do not diminish the building’s essential qualities as a showroom and repair facility. WORKMANSHIP The majority of the building’s original materials and method of assembly are still visible to illustrate construction of a modest retail building in the early twentieth century. The building has a reasonable level of original workmanship, and early twentieth century details such as the arched fanlight transoms remain extant. FEELING 901 Hermosa Avenue retains integrity of feeling. With auto circulation accommodated by an angled corner and extant driveway and an intact front showroom façade, it continues to express the aesthetics and form of an early automobile retail and repair facility in a main street retail district. ASSOCIATION 901 Hermosa Avenue retains integrity of association. It maintains its relationship to the street with its distinctive three-part façade and angled corner continues to convey its original use as an automobile-related business. Page 259 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 39 April 17, 2024 Overall, 901 Hermosa Avenue retains all seven aspects of integrity for local listing. California Environmental Quality Act (CEQA) The California Environmental Quality Act (CEQA) is state legislation (Pub. Res. Code §21000 et seq.) that provides for the development and maintenance of a high-quality environment for the present- day and future through the identification of significant environmental effects.38 CEQA applies to “projects” proposed to be undertaken or requiring approval from state or local government agencies.39 “Projects” are defined as “activities which have the potential to have a physical impact on the environment and may include the enactment of zoning ordinances, the issuance of conditional use permits and the approval of tentative subdivision maps.”40 Historic and cultural resources are considered to be part of the environment. In general, the lead agency must complete the environmental review process as required by CEQA. In the case of a proposed project at 901 Hermosa Avenue, the City of Hermosa Beach will act as the lead agency. STATUS AS A HISTORICAL RESOURCE UNDER CEQA In completing an analysis of a project under CEQA, it must first be determined if the project site possesses a historical resource. A site may qualify as a historical resource if it falls within at least one of four categories listed in California Code of Regulations (CCR), Title 14, Section 15064.5(a). The four categories are: 1. A resource listed in, or determined to be eligible by the State Historical Resources Commission, for listing in the California Register of Historical Resources (Pub. Res. Code SS5024.1, Title 14 CCR, Section 4850 et seq.). 2. A resource included in a local register of historical resources, as defined in Section 5020.1(k) of the Public Resources Code or identified as significant in an historical resource survey meeting the requirements of section 5024.1 (g) of the Public Resources Code, shall be presumed to be historically or culturally significant. Public agencies must treat any such resource as significant unless the preponderance of evidence demonstrates that it is not historically or culturally significant. 3. Any object, building, structure, site, area, place, record, or manuscript which a lead agency determines to be historically significant or significant in the architectural, engineering, 38 Public Resources Code (PRC), Section 21000 et seq. 39 Guidelines for Implementation of the California Environmental Quality Act (CEQA Guidelines), California Code of Regulations (CCR), Title 14, Section 15000 et seq. 40 14 CCR § 15378: Project. Page 260 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 40 April 17, 2024 scientific, economic, agricultural, educational, social, political, military, or cultural annals of California may be considered to be an historical resource, provided the lead agency’s determination is supported by substantial evidence in light of the whole record. Generally, a resource shall be considered by the lead agency to be “historically significant” if the resource meets the criteria for listing on the California Register of Historical Resources (Pub. Res. Code SS5024.1, Title 14 CCR, Section 4852). 4. The fact that a resource is not listed in, or determined to be eligible for listing in the California Register of Historical Resources, not included in a local register of historical resources (pursuant to section 5020.1(k) of the Pub. Resources Code), or identified in an historical resources survey (meeting the criteria in section 5024.1(g) of the Pub. Resources Code) does not preclude a lead agency from determining that the resource may be an historical resource as defined in Pub. Resources Code sections 5020.1(j) or 5024.1. In general, a resource that meets any of the four criteria listed in CEQA Guidelines Section 15064.5(a) is considered to be a historical resource unless “the preponderance of evidence demonstrates” that the resource “is not historically or culturally significant.”41 The subject property at 901 Hermosa Avenue is not currently listed in the California Register and this HRA finds that the property is not eligible for listing in the California Register. The property is not included in a local register of historic resources, nor has it been included in a survey meeting the requirements of PRC § 5024.1(g).42 Therefore, 901 Hermosa Avenue does not appear to meet the thresholds for status as a historical resource under CEQA. 41 14 CCR § 15064.5(a)(2). 42 Refer also to Section II. Existing Historic Status of this report relative to 14 CCR § 15064.5(a)(2) and PRC § 5024.1(g). Page 261 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 41 April 17, 2024 VII. CONCLUSION Constructed in 1922 as a vernacular commercial automobile showroom and repair facility with Mission Revival style features, 901 Hermosa Avenue was previously identified as potentially eligible for local landmark designation in a 2014 windshield survey. This HRA finds that the property remains eligible for local listing. However, the property does not rise to the level of significance require to meet the eligibility criteria for individual listing in the National Register or the California Register. Per California Environmental Quality Act (CEQA) Guidelines (14 CCR § 15064.5(a)), as 901 Hermosa Avenue is not currently listed in a local register of historic resources or in the California Register, and is not eligible for listing in the California Register, the property is not a historic resource for the purposes of the CEQA.43 43 14 CCR § 15064.5(a). Page 262 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 42 April 17, 2024 VIII. REFERENCES Published Works & Reports California Office of Historic Preservation. Technical Assistance Bulletin No. 7: How to Nominate a Resource to the California Register of Historical Resources. Sacramento: California Office of State Publishing, September 4, 2001. California Office of Historic Preservation. Technical Assistance Bulletin No. 8: User’s Guide to the California Historical Resource Status Codes & Historic Resources Inventory Directory. Sacramento: California Office of State Publishing. November 2004. Gazin, Patricia A. Footnotes on the Sand. Hermosa Beach: Myron Gazin, 1991. Longstreth, Richard. The Buildings of Main Street. Washington DC: Preservation Press, 1987. Miller, Chris Ann and Jerry Roberts. Images of America: Hermosa Beach. Charleston, SC: Arcadia Publishing, 2005. National Park Service. National Register Bulletin 15: How to Apply the National Register Criteria for Evaluation. Washington, D.C.: U.S. Department of the Interior, National Park Service, 1995. Partner Engineering and Science, Inc. Phase 1 Environmental Site Assessment Report, 901 Hermosa Avenue. Prepared for Powerscourt Partners LLC, July 2022. PCR Services. “7.0 Cultural Resources, Technical Background Report.” In 2017 City of Hermosa Beach PLAN Hermosa. Prepared for the City of Hermosa Beach, August 2017. Prosser, Daniel, and Daniel Herrick. “Commercial Development, 1850-1980: Commercial Development and the Automobile, 1910-1970.” In Survey LA Los Angeles Historic Resources Survey, Los Angeles Citywide Historic Context Statement, prepared for the City of Los Angeles Department of City Planning, August 2016. Scheerer, Lorietta Louise. “The History of the Sausal Redondo Rancho.” MA thesis, University of Southern California, 1938. Newspapers & Periodicals Anderson, Sadie. “Society,” Oklahoma City Times. June 16, 1922. Daily Law Journal-Record (Oklahoma City, OK). “Notice of First Meeting of Creditors.” March 9, 1922. Daily Oklahoman (Oklahoma City, Oklahoma). “Oklahoma City Pays $300,000 Annually To Say It With Flowers.” November 6, 1921. Los Angeles Times. “Handsome Archway: Hermosa Beach Is Adding Decorative Additions to Its Pleasure Pier, Rest Rooms Provided.” January 4, 1914. _________. “Completion of New Boulevard Lends Impetus.” July 31, 1927. _________. “Winter Resort in Desert Will Be Cooperative” February 23, 1930. Page 263 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 43 April 17, 2024 Redondo Reflex (Redondo, California). “New $25,000 Lincoln-Ford-Fordson Agency at Hermosa Beach.” October 13, 1922. _________. “Agitate for Hotel.” October 20, 1922. _________. “Hermosa News.” July 20, 1923. _________. “Locates in Redondo.” Jun12, 1925. Public Records California Code of Regulations (CCR). Accessed online April 17, 2024, https://casetext.com/regulation/california-code-of-regulations. Public Resources Code (PRC). Accessed online April 17, 2024, https://leginfo.legislature.ca.gov/faces/codesTOCSelected.xhtml?tocCode=PRC&tocTitle=+Pu blic+Resources+Code+-+PRC. California State Office of Historic Preservation. Built Environment Resource Directory (BERD), Los Angeles County. September 2022. Archival Records California United States Death Index, 1880-1995. Accessed through Ancestry.com. Oklahoma County Marriage Records, 1889-1951. Accessed through Ancestry.com. Parcel Maps. Accessed through the Los Angeles County Assessor. Tract Maps. Accessed through the Los Angeles County Public Works. 1900 United States Federal Census. Accessed through Ancestry.com. Internet Sources City of Hermosa Beach. “Historic Resources.” Accessed February 15, 2024. https://www.hermosabeach.gov/our-government/city-departments/community- development/historic-resources. Page 264 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 44 April 17, 2024 IX. APPENDICES Appendix A – Preparer Qualifications This Historic Resource Evaluation was prepared by Page & Turnbull of Los Angeles, California. Page & Turnbull staff responsible for this report include Christina Dikas, Principal-in-charge; Hannah Simonson, Senior Associate, Cultural Resources Planner, project manager; and Stephanie Hodal, Cultural Resources Planner, primary author, all of whom meet the Secretary of the Interior’s Professional Qualification Standards for Architectural History. Page 265 of 324 Historic Resources Assessment (HRA) 901 Hermosa Avenue [24017] Hermosa Beach, CA PAGE & TURNBULL 45 April 17, 2024 Appendix B – 2014 DPR Form for 901 Hermosa Avenue Page 266 of 324 Primary #State of California – The Resources Agency DEPARTMENT OF PARKS AND RECREATION HRI # Trinomial NRHP Status Code 5S3Other Listings Review Code __________ Date _______________Reviewer ____________________________ PRIMARY RECORD c. Address:901 Hermosa Ave City Hermosa Beach Zip 90254 a. County Los Angeles P1. Other Identifier: Not for Publication Unrestricted b. USGS 7.5' Quad Date T R 1/4 of 1/4 of Sec B.M. Zone mE/mN Parcel No.4187-003-028 P3b. Resource Attributes:HP 6. 1-3 story commercial building Building Structure Object Site District Element of District Other (Isolates, etc.) Prehistoric Historic Both 1928 PCR Services 201 Santa Monica Blvd, Ste 500 Santa Monica, CA 90401 P9. Date Recorded:1/1/2014 Windshield Reconnaissance Hermosa Beach General Plan Update, 2014 NONE Location Map Sketch Map Continuation Sheet Building, Structure, and Object Record Archaeological Record District Record Linear Feature Record Milling Station Record Rock Art Record Artifact Record Photograph Record P2. Location: and (P2b and P2c or P2d. Attach a Location Map as necessary.) Attachments: Other: (List) P4. Resources Present: P11. Report Citation:(Cite survey report and other sources, or enter "none.") d. UTM: (Give more than one for large and/or linear resources) P5b Description of Photo: P6. Date Constructed/Age and Sources: e. Other Locational Data (e.g. Parcel #, directions to resource, elevation, etc., as appropriate) (Assigned by recorder) P10. Survey Type:(Describe) P8. Recorded by: (Name, affiliation, and address) P7. Owner Address: ;; ; (Describe resources and its major elements. Include design, materials, condition, alterations, size, and boundaries) (List attributes and codes) (View, date, accession #) ; North West, 12/12/13 P3 Description: This one-story commercial building maintains its integrity and is potentially eligible as a good example of the Art Deco/Moderne style. Page of Resource Name or #: DPR 523B (1/95) PCR Services Corporation Page 267 of 324 Imagining change in historic environments through design, research, and technology 170 MAIDEN LANE, 5TH FLOOR SAN FRANCISCO, CALIFORNIA 94108 TEL 415-362-5154 523 WEST 6TH STREET, SUITE 1013 LOS ANGELES, CALIFORNIA 90014 TEL 213-221-1200 1007 7TH STREET, #404 SACRAMENTO, CALIFORNIA 95814 TEL 916-930-9903 75 EAST SANTA CLARA STREET, SUITE 900 SAN JOSE, CALIFORNIA 95113 TEL 408-320-7911 Page 268 of 324 MARK DATE DESCRIPTION SHEET TITLE CONSULTANTS PROJECT NO: 22007 MODEL FILE: 22007 - 901 Hermosa Ave - Powerscourt DRAWN BY: COPYRIGHT: SHEET 89 OF 136 A-603 CURTAIN WALL SCHEDULE ARCHITECT ANTHONY LANEY AIA LANEY LA, INC. 725 CYPRESS AVE HERMOSA BEACH CA 90254 (310) 870-7175 ANTHONY@LANEY.LA 11-06-23 PLANNING SUBMITTAL PROJECT NAME 901 HERMOSA PROJECT NUMBER 22007 CLIENT 901 HERMOSA PARTNERS LLC PROJECT ADDRESS 901 HERMOSA AVE HERMOSA BEACH, CA 90254 10-09-24 PLANNING SUBMITTAL 12-03-24 PLANNING SUBMITTAL 12-18-24 BID PROGRESS SET 06-27-25 PLANNING SUBMITTAL8 10-08-25 PLANNING COM. HEARING9 CURTAIN WALL SCHEDULE Element ID CW-A CW-B CW-D CW-E CW-F CW-G CW-H CW-I CW-J CW-K CW-L Number of Panels 26 6 14 8 10 2 3 5 9 5 6 MODEL <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> MFG ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA ARCADIA MATERIAL ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS ALUM / GLASS FINISH POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE POWDER COATED - DARK BRONZE SURFACE AREA 581.59 132.45 386.49 221.57 284.70 58.54 89.71 125.76 226.99 147.24 176.10 REMARKS D E 34.67' 45.29'2'-0"8'-7 1/2"5'-6"2"8'-5 1/2"14'-1" ZONE L 36.67' 31.17' CW-K CW-L 2 3 4 45.29'8'-7 1/2"8'-6"2"8'-5 1/2"37'-7" ZONE A 16'-8" ZONE B 3'-0" ZONE C 17'-1 1/2"CW-A CW-B 207.1 206.1 205.1 34.67' 45.29'2'-0"8'-7 1/2"24'-2" ZONE D.1 36.67' CW-D.1 C B 34.67' 45.29'10'-7 1/2"19'-1" ZONE D.2 27'-11" ZONE E 20'-6 1/2" ZONE F.1 36.67'2'-0"8'-7 1/2"CW-D CW-FCW-E 3 24 34.67' 45.29'2'-0"16'-2" ZONE F.2 7'-5" ZONE G 11'-4" ZONE H 16'-0" ZONE I 23'-7" ZONE J.1 36.67' CW-F CW-G CW-H CW-I CW-J B C 34.67' 45.29'2'-0"6'-10" ZONE J.2 36.67' 316.A 316.1 316.B 316.C 320.A 320.1 310.B 308.A 309.A 310.A 308.1310.1309.1318.A 303.A 303.C 312.1 318.B 306.A 306.1305.A305.1323.A 316.1325.1320.B 321.1 322.1 325.2311.B 304.A 303.B 301.A303.1 301.1304.1 311.A 311.C 317.A 317.B 317.1 317.C 314.A 315.A314.1314.2 SK-1 SK-2 SK-3 F DW F 4A-404 1A-405 3A-908 9A-908 9A-908 1A-203 4'-2"3'-1/2"R.O.11'-5 3/4"9'-3 3/4"6'-2"2'-7 1/2"3'-3"R.O.3 3/4"5'-9" 6 1/2" 2'-8 1/2"RO 15'-3 1/4"9'-3"6'-2"7'-1/2"18'-9 3/4"15'-8 1/2"4'-9"2'-1"7'-6 1/4"4'-1 1/2"48'-3 3/4"45" CLR2'-7 1/4"4'-2"RO 2'-1 1/2" 28'-1"5'-0"10'-10 1/2"R.O.16'-11 1/4"12'-11"5'-3"6'-2 1/2"2'-10"3'-7 1/2"5'-6 1/4"5'-5 3/4"3'-0"14'-0"RO F.F. = 18.17'= 34.67' FF =18.25' = 34.75' FF = 18.17'= 34.67' WT07-B WT07-B WT04-A WT07-A WT11 WT07-BWT07-BWT11WT11 WT12 WT12 WT04-A WT07-B WT06ALIGNALIGN WT14-B WT14-BWT14-BWT14-BWT14-BWT14-BWT06WT15-A WT14-AWT14-AWT07-B WT07-AWT04-A WT07-BWT07-BWT07-BWT04-AWT16 WT16 W T16WT16WT16 WT14-B WT14-B WT16WT16WT16WT14-A WT07-B WT07-BWT11WT12WT09-CWT15-BWT14-AWT14-A WT14-AOPEN TOABOVE OPEN TOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOABOVE OPENTOBELOW OPENTOBELOW OPENTOABOVE OPENTOABOVE ELEVATOR 01 STAIR 02324 MECHANICAL PLATFORM312 OFFICE305 GARDEN PATIO 303 OFFICE301 OFFICE 315 OFFICE308 OFFICE310 COURTYARD318 GARDEN 316 CONFERENCE RM 314 OFFICE309 OFFICE304 RSTRM 321 KITCHEN319 ELEVATOR 02 RSTRM322 OUTDOOR ROOM 317 GARDEN 311 GARDEN 320 GARDEN323 VESTIBULE306 STAIRWELL EXIT325 RESTROOM CORRIDOR324 MECH. PLATFORM 302 STAIR 01327 DN DN 3A-907 7'-2 3/4"4'-3 1/2"7'-5"4'-8 1/2"6'-10 3/4"8'-0"4'-6 1/4"8'-0"4'-4 3/4"8'-0"5'-3/4"VIF319.1 308.B 309.B 09 09 09 09 09 0505 06 07 07 07 WT04-A WT14-BWT15-BWT09-COPENTOABOVE 465 SQ FTLID PLANTER GREEN ROOF 307 SCALE: 1' = 1'-0"8 CURTAIN WALL SCHEDULE SCALE: 1/4" = 1'-0"2 CURTAIN WALL ELEVATION - ZONE K & L 0 2'4'8' SCALE: 1/4" = 1'-0"5 CURTAIN WALL ELEVATION - ZONE A, B & C 0 2'4'8' SCALE: 1/4" = 1'-0"4 CURTAIN WALL ELEVATION - ZONE D.1 0 2'4'8' SCALE: 1/4" = 1'-0"6 CURTAIN WALL ELEVATION - ZONE D.2, E, & F.1 0 2'4'8' SCALE: 1/4" = 1'-0"7 CURTAIN WALL ELEVATION - ZONE F.2, G, H, I, & J.1 0 2'4'8' SCALE: 1/4" = 1'-0"1 CURTAIN WALL ELEVATION - ZONE J.2 0 2'4'8' SCALE: 3/32" = 1'-0"3 CURTAIN WALL KEY Page 269 of 324 Public Notification Package- 901 Hermosa Avenue Page 270 of 324 Page 271 of 324 Page 272 of 324                                                                        7KH6 W UDQG WK6W+HUPRVD$YH%HDFK' U WK6W WK6W WK6W WK6W%HDFK'U3DOP'U WK6W WK6W 3LHU $YH 0D Q KDW WDQ $YH6XQVHW'U WK&W WK&W WK&W WK&W WK&W WK&W 0RQWHUH\%OYGWK&W 3LHU3OD]D %D\YLHZ'U                                                             5$',860$3 $''5(66+HUPRVD$YH+HUPRVD%HDFK&$Q Page 273 of 324 Community Development Department Planning Division City of Hermosa Beach 1315 Valley Drive Hermosa Beach, CA 90254 IMPORTANT PUBLIC NOTICE 901 Hermosa Avenue, Hermosa Beach, CA 90254 Assessor Parcel Number 4187-003-028 NOTICE IS HEREBY GIVEN that the Planning Commission of the City of Hermosa Beach will hold a Public Hearing on Tuesday, October 21, 2025, at 6:00 p.m. to consider the request described below. A PRECISE DEVELOPMENT PLAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REMODEL AND ADD TO AN EXISTING TWO-STORY COMMERCIAL BUILDING THAT MEASURES 14,021 SQUARE FEET. THE PROJECT ADDS A THIRD STORY WITH A HEIGHT OF 28 FEET 9.6 INCHES AND RECONFIGURES THE EXISTING BUILDING LAYOUT, RESULTING IN A DECREASE OF 194 SQUARE FEET OF USABLE FLOOR AREA FOR A REMODELED MULTI-TENANT COMMERCIAL BUILDING AT 901 HERMOSA AVENUE IN THE GENERAL COMMERCIAL (C-2) ZONE. THE LOT LINE ADJUSTMENT CONSOLIDATES THREE EXISTING PARCELS INTO A SINGLE LOT. CEQA: THE PROJECT QUALIFIES FOR A CLASS 1 CATEGORICAL EXEMPTION PER SECTION 15301 AND CLASS 5 CATEGORICAL EXEMPTION PER SECTION 15305 OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT GUIDELINES. AMERICANS WITH DISABILITIES ACT OF 1990 To comply with the Americans with Disabilities Act of 1990, Assistive Listening Devices (ALD) are available for check out at the meeting. If you require special assistance to participate in this meeting, you must call or submit your request in writing to the Office of the City Clerk at (310) 318-0204 or at cityclerk@hermosabeach.gov at least 48 hours before the meeting. PARTICIPATION AND VIEWING OPTIONS - Hermosa Beach Planning Commission meetings are open to the public and are being held in person in the City Hall Council Chambers located at 1315 Valley Drive, Hermosa Beach, CA 90254. Public comment is only guaranteed to be taken in person at City Hall during the meeting or prior to the meeting by submitting an eComment for an item on the agenda. As a courtesy only, the public may view and participate on action items listed on the agenda via the following: Zoom - https://us02web.zoom.us/j/82539742028?pwd=ountrdnvd2l6tzbptdljc2x6bgfwdz09 Meeting ID: 825 3974 2028 Password: 207860 Phone - Toll Free: (833) 548-0276 Meeting ID: 825 3974 2028, then #; Passcode: 207860 eComment - Submit an eComment by 3:00 p.m. on the meeting date. Supplemental Email - Supplemental emails are available for agenda items only and must be sent to Community Development at planning@hermosabeach.gov. Supplemental emails should indicate the agenda item plus meeting date in the subject line and must be received by 3:00 p.m. on the meeting date. Emails received after the deadline but before the meeting ends will be posted to the agenda the next business day. Please be advised that while the City will endeavor to ensure remote participation methods are available, the City does not guarantee that they will be technically feasible or work all the time. Further, the City reserves the right to terminate these remote participation methods (subject to Brown Act restrictions) at any time and for whatever reason. Please attend in person or by submitting an eComment to ensure participation. Similarly, as a courtesy, the City will also broadcast the meeting via the following listed mediums. However, these are done as a courtesy only and not guaranteed to be technically feasible. To guarantee live time viewing and/or public participation, members of the public shall attend in Council Chambers. If you experience technical difficulties while viewing a meeting on any of our digital platforms, please try another viewing option. View staff reports and attachments at www.hermosabeach.gov/agenda. Cable TV - Spectrum (channel 8) and Frontier (channel 31) in Hermosa Beach YouTube - https://www.youtube.com/c/cityofhermosabeach90254 Live Stream - www.hermosabeach.gov/agenda Alison Becker Community Development Director Page 274 of 324 Page 275 of 324 Page 276 of 324 Page 277 of 324 Page 278 of 324 Page 279 of 324 Page 280 of 324 Page 281 of 324 Public Notification Package- 901 Hermosa Avenue Page 282 of 324 Page 283 of 324 City of Hermosa Beach PUBLIC HEARING NOTICE NOTICE IS H~~EB'i' GIVEN Iha! !he C,halrperso1rofthe Hermqsa Beach Planning Commission has calle,ra special p11blic hearing 9n Tuesday, Docembor 16, AA25, at 5:00 p.m. lo co~lder an!! take action on only,those-malle$set forth on·lhe-agenda below. 1. A PRECISE DEI/El0P.MENT P.LAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REM0DELAND ADD ro AN EXISTING TWO-STORY COMMERCIAL BUILDING. THE PROJECT ADDS A TI-IIRD STORY WITH A HEIGHT OF 28 FEET 9.6 INCHES AND RECONFlGU~ES THE EXI.STll'/G BUILDING LAYOUT, RESULTING IN A REMODELED•MULTHENANT COMMERCIAL BUILDING, AT 901 HERMOSA AVENUE, IN TI-IE DOWNTOWN COMMEReW..(<:;;2f ioNE. THE LOT'LINEAOJUSTMENT CONSOLIDATES THREE EXISTI,;iG PARCELS INT0 'A SINGLE-LOT. CEOA: THE PROJECT QUALIFIES FOR A CLASS 1 CATEGORICAL EXEMPTION PER SECTION 15301 AND CLASS 5 CATEGORICAL EXEMPTION PER SECTION 5305 OF THE CEOA GUIDELINES. 2. A PRECISE DEVELOPMENT PLAN (PDP 25-01) FORA NEW 6,487-SQUARE-FOOT MULTI-TENANT COMMERCIAL BUILDING WITii A HEIGHT OP 24 FEET AND 11 INCHES AND 25 PARKING SPACES, AT 1054AVIATION BOULEVARD, LOCATED WITI-IIN THE GENERAL COMMERCIAL ZONE (C-3). CEOA: THE PROJECT QUALIFIES FOR CLASS 3 CATEGORICAL EXEMPTION PER SECTION 15303 OF THE CEOA GUIDELINES. 3. A ZONE TEXT AMENDMENT AMENDING VARIOUS SECTIONS OF TITLE 17 OF TI-IE HERMOSA BEACH MUNICIPAL CODE PERTAINING TO APPEAL PERIODS AND TRANSMISSION OF PLANNING COMMISSION'S RECORD TO CITY COUNCIL (CITYWIDE). CEOA: THE PROJECT IS EXEMPT FROM CEOA PER SECTION 15061(b) (3) OF THE CEOA GUIDELINES. 4. A ZONE TEXT AMENDMENT AMENDING HERMOSA BEACH MUNICIPAL CODE SECTION 17.08.Q20.(d) PERTAINING TQ H0M.E'OCCUPATIONS (CITYWIDE). CEOA: THE PR0JECT IS EXEMPT FROM CEOAP.ER SECTION 15061(b)(3) OF 11-IE <;EOAGU.IDELINES. SAID PUBLIC MEETING is open to the public and ls,be1119 '1eld in-person in the City HaK Council Chambers located at 1315 Valley Drive, Hermosa Beacll;'Galifornia,90254. PUBLIC PARTICIPATION. See tho meeting agend~fo< aD pul)~conmlfll delails end oppo~nilies. All written l~timony by a11y lillerested party will be'aooepted prior too, at lhe acheduled,ti~ on the agenda lor•lhe matter. Information regarding lhe ~ns with Disabilities Act of 1990, please.\llsij,tlle meeting age~ or contact the Office of Ille City Clelil el (310} 318-0204 or cjtycierl<@hc{JDQSjlbeach goy. VIEWING OPTIONS are available on Spectrum Channel 8, Frontier Channel 31, YouTube, Zoom, and/or the City's website. IF YOU CHALLENGE the above-lT\3He<:(s) in court, you may be limited to raising only those issues that are raised at or before the publtc hearing: FOR,•,F\JRTHER INFORMATION, P,loa!Hl contac,t th~ C_ommunlty De'Vall>pme11t Oepar!ment at t310)•318-0242 ~r plannJng@h"lllHi5'a!Je•".tl,gqy, A copy,o/ lhe. agen<!_aarid-~ta.lf r:epor1(~) Wlll be viewable on·1he City's websile 72 hours·bero/li tlie'meeling.A$ a courtesy, the he3fiiig,c;arfbe viewed on Sped/um Channel 8, Frontier Channel 31 .. YouTulie, Zoom, and/or,lhe Cif9'-s websllc, Alison Backer, AICP Community Deveiopl)lenl llJ(ector Easy Reader Inc/Redondo Beach News/December 4, 2025/HD25-048 Page 284 of 324 111250 1272 738130117 1128 606872901138 1120 1140 1144 1401130 1125 1111 947226935 925 823 806 235 221 817 1040 1048 1102 1112 1142 1068 1057 1047 1027 1126 1121 1075 1069 1150 1158 1103 1113 1051 10191041 1086 1066 1076 1038 1054 1084 700 18635625294361632 612 600721 707 701 647 629 617 602 610 620 626 704 609 637 601 634646 747222745 722 713 712 738742208 644 702 614 621622 636 638 728 544 218520 526 530 538 534 542 541 533 525The S t rand 10th StHermosa AveBeach D r 9th St 7th St 11th St 8th StBeach DrPalm Dr 6th St 11th St P i e r A v e Ma n hat tanAveSunset Dr 7th Ct 8th Ct 9th Ct 10th Ct 12th Ct 11th Ct Monterey Blvd13th Ct Pier Plaza Bayview Dr 802 808 814 820 830 3642486683725313963801840920 940 202632505864697019283744539015455900 1020 1042 224652243440414759651001101610311101 1033 1106 1110 10451046 1035 1025 1011 131 1021 10141105 150 931 928 915 841 825 821 815 121 119810 822 832 844 906 910 831834934950 924 921 907 845 211207816 836 908 918 926 805 828 902 214 1002 1028 1022 1012 720 730 732 740 733561727333845495771162126 134 734 727 710 719718 726 736 100 500' RADIUS MAP ADDRESS: 901 Hermosa Ave, Hermosa Beach, CA 90254 r Page 285 of 324 Community Development Department Planning Division Attn: KP City of Hermosa Beach 1315 Valley Drive Hermosa Beach, CA 90254 IMPORTANT PUBLIC NOTICE 901 Hermosa Avenue, Hermosa Beach, CA 90254 Assessor Parcel Numbers: 4187-003-028 NOTICE IS HEREBY GIVEN that the Planning Commission of the City of Hermosa Beach will hold a Public Hearing on Tuesday, December 16, 2025, at 5:00 p.m. to consider the request described below. A PRECISE DEVELOPMENT PLAN (PDP 23-04) AND LOT LINE ADJUSTMENT (LLA 23-03) TO REMODEL AND ADD TO AN EXISTING TWO-STORY COMMERCIAL BUILDING. THE PROJECT ADDS A THIRD STORY WITH A HEIGHT OF 28 FEET 9.6 INCHES AND RECONFIGURES THE EXISTING BUILDING LAYOUT, RESULTING IN A REMODELED MULTI-TENANT COMMERCIAL BUILDING, AT 901 HERMOSA AVENUE, IN THE DOWNTOWN COMMERCIAL (C-2) ZONE. THE LOT LINE ADJUSTMENT CONSOLIDATES THREE EXISTING PARCELS INTO A SINGLE LOT. CEQA: THE PROJECT QUALIFIES FOR A CLASS 1 CATEGORICAL EXEMPTION PER SECTION 15301 AND CLASS 5 CATEGORICAL EXEMPTION PER SECTION 5305 OF THE CEQA GUIDELINES. AMERICANS WITH DISABILITIES ACT OF 1990 To comply with the Americans with Disabilities Act of 1990, Assistive Listening Devices (ALD) are available for check out at the meeting. If you require special assistance to participate in this meeting, you must call or submit your request in writing to the Office of the City Clerk at (310) 318-0204 or at cityclerk@hermosabeach.gov at least 48 hours before the meeting. PARTICIPATION AND VIEWING OPTIONS - Hermosa Beach Planning Commission meetings are open to the public and are being held in person in the City Hall Council Chambers located at 1315 Valley Drive, Hermosa Beach, CA 90254. Public comment is only guaranteed to be taken in person at City Hall during the meeting or prior to the meeting by submitting an eComment for an item on the agenda. As a courtesy only, the public may view and participate on action items listed on the agenda via the following: Zoom - https://us02web.zoom.us/j/82539742028?pwd=ountrdnvd2l6tzbptdljc2x6bgfwdz09 Meeting ID: 825 3974 2028 Password: 207860 Phone - Toll Free: (833) 548-0276 Meeting ID: 825 3974 2028, then #; Passcode: 207860 eComment - Submit an eComment by 3:00 p.m. on the meeting date. Supplemental Email - Supplemental emails are available for agenda items only and must be sent to Community Development at planning@hermosabeach.gov. Supplemental emails should indicate the agenda item plus meeting date in the subject line and must be received by 3:00 p.m. on the meeting date. Emails received after the deadline but before the meeting ends will be posted to the agenda the next business day. Please be advised that while the City will endeavor to ensure remote participation methods are available, the City does not guarantee that they will be technically feasible or work all the time. Further, the City reserves the right to terminate these remote participation methods (subject to Brown Act restrictions) at any time and for whatever reason. Please attend in person or by submitting an eComment to ensure participation. Similarly, as a courtesy, the City will also broadcast the meeting via the following listed mediums. However, these are done as a courtesy only and not guaranteed to be technically feasible. To guarantee live time viewing and/or public participation, members of the public shall attend in Council Chambers. If you experience technical difficulties while viewing a meeting on any of our digital platforms, please try another viewing option. View staff reports and attachments at www.hermosabeach.gov/agenda. Cable TV - Spectrum (channel 8) and Frontier (channel 31) in Hermosa Beach YouTube - https://www.youtube.com/c/cityofhermosabeach90254 Live Stream - www.hermosabeach.gov/agenda Alison Becker, AICP, Community Development Director Page 286 of 324 AFFIDAVIT OF MAILING NOTICES I, Denise Kaspar , being duly sworn, deposes and says: that I am a citizen of the United States, over the age of 18 years; that acting for the County of Orange on the 2nd day of December , 2025, that I deposited 694 notices as described below in the United States Post Office, a Public Hearing Notice, a copy of which is attached hereto, with postage thereon prepaid, addressed to the following persons at the addresses shown, to-wit: (See list attached hereto and made part hereof) that said persons are the property owners of said property who are entitled to a Public Hearing Notice: APN: 4187-003-028 Subject: 901 HERMOSA AVE HERMOSA BEACH CA 90254-4457 that on said day there was regular communication by United States Mail to the addresses shown above. Page 287 of 324 Palm DrManhattan AveBeach D r 9th S t 7th S t 11th S t 10th S t Hermosa AveBeach D r 8th S t 6th S t P i e r A v e The St rand 7th C t 8th C t Sunset Dr 9th C t 10th C t 12th C t 11th C t Monterey B lvd Pier P l a z a Bayview DrProject Zoning Map Planning CommissionDecember 16, 2025 Description 901 Hermosa Avenue APN: 4187-003-028 Zone: C-2 Downtown Commercial Precise Development Plan Legend R-1 Single Family Residential R-1A Limited Single-Family Residential R-2 Two Family Residential R-2B Limited Multiple Family Residential R-3 Multiple Family Residential R-P Residential-Professional RPD Residential Planned Development R-3PD Multiple Family Planned Development C-1 Neighborhood Commercial C-2 Downtown Commercial C-3 General Commercial M-1 Light Manufacturing OS Open Space OS-1 Restricted Open Space OS-2 Restricted Open Space OS-O Open Space Overlay MHP Mobile Home Park SPA Specific Plan Area (Residential) SPA Specific Plan Area (Commercial) 500' Notification Radius Page 288 of 324 Page 289 of 324 Page 290 of 324 City of Hermosa Beach | Page 1 of 3 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-168 Honorable Chair and Members of the Hermosa Beach Planning Commission LOCATION: CITYWIDE A ZONE TEXT AMENDMENT (TA25-03) AMENDING VARIOUS SECTIONS OF TITLE 17 OF THE HERMOSA BEACH MUNICIPAL CODE SECTION PERTAINING TO APPEAL PERIODS AND THE TRANSMISSION OF PLANNING COMMISSION DECISIONS TO CITY COUNCIL CEQA: The project qualified for a Categorical Exemption per Section 15061(b)(3) of the California Environmental Quality Act Guidelines. (Planning Manager Alexis Oropeza) Recommended Action: Staff recommends the Planning Commission: 1. Find the adoption of the proposed ordinance exempt from review under the California Environmental Quality Act (“CEQA”) and 2. Adopt a Resolution (Attachment 1) recommending that the City Council adopt the proposed ordinance approving Zone Text Amendment 25-03. Executive Summary: The City Council amended the process for reviewing Planning Commission decisions under Title 2 of the Hermosa Beach Municipal Code (HBMC). The Council review period now starts following the Planning Commission’s decision. To allow for public appeal and City Council review simultaneously, Title 17 also needs to be amended. Staff recommends these updates to make the process more clear and more efficient. Background: At the October 14, 2025, meeting of the City Council, the City Council amended Title 2 of the HBMC to eliminate the sequential process of the City Council’s review of Planning Commission actions and the public appeal process. Under the prior procedures, applicants typically waited at least three weeks for the review and then the appeal process to expire. However, the timeframe could be extended by up to six to eight weeks, particularly if there are five weeks in a month, holidays, or both. Ordinance No. 25-1491 adopted by the City Council, established new procedures that would allow for a concurrent timeframe for public appeal and City Council review. In addition, the call-up period was revised to a fixed 15 days following the Planning Commission’s decision. Page 291 of 324 City of Hermosa Beach | Page 2 of 3 To facilitate this concurrent process, the Planning Commission action report will no longer be presented at a City Council meeting. Instead, action minutes from the Planning Commission meeting will be posted within 24 hours of the meeting, and City Staff will send a courtesy notice to Councilmembers. The City Council could then review and submit a form requesting to schedule a future review of the application with the City Clerk. Upon receipt of two requests for the same item the matter would be scheduled for a review at future City Council meeting. Past Board, Commission, and Council Actions Meeting Date Description October 14, 2025 City Council adopted an Ordinance amending Section 2.52.040, establishing that the CC review timeline should commence following the Planning Commission’s action and run concurrently with the public appeal process The Planning Commission serves as the advisor to the City Council on all land-use matters, and the Planning Commission must review the Zone Text Amendment and make a recommendation to the City Council. Discussion: The City must amend HBMC Title 17-Zoning for consistency with recent Title 2 amendments. City Council call-up procedures for Variances and Conditional Use Permits are cited in the appeals section for these entitlements and have a 10-day appeal period. To align the public appeal period and City Council review timeframes, appeal periods are proposed to change from ten (10) days to fifteen (15) days, starting after the Planning Commission’s decision. Similarly, the appeal periods for Conditional Use Permits for residential condominium conversions and Development Agreements are proposed change from ten (10) days to fifteen (15) days. The proposed amendment also updates the decision-making body for variances to reflect that the Planning Commission, not the defunct Board of Zoning Adjustments, is responsible for this role. The recommended changes would create consistency in appeal and review timeframes, making the process more transparent to the public, more straightforward for staff, and more predictable for applicants. General Plan Consistency: PLAN Hermosa, the City’s General Plan, was adopted by the City Council in August 2017. The proposed zone text code amendment regarding appeal periods and City Council review of Planning Commission actions has been reviewed with PLAN Hermosa and is consistent with the goals and policies listed below. Governance Element Goal 1. The community is active and engaged in decision-making processes. Page 292 of 324 City of Hermosa Beach | Page 3 of 3 Policies:  2.9 Evaluation and feedback. Periodically solicit service evaluations from the community and utilize feedback to improve and develop the City’s policies, ordinances, programs, and funding priorities. Goal 5. Small beach town character is reflected throughout Hermosa Beach. Policies:  5.2 Development Decisions. Strive to conduct the development review process in a consistent and predictable manner.  5.3 Clear regulations. Establish clear, unambiguous regulations and policies to clearly communicate the City’s expectations for new development. Environmental Determination: The proposed zone text amendment is a project subject to the California Environmental Quality Act (CEQA) and qualifies for an exemption from CEQA pursuant to Section 15061(b)(3) (Common Sense Exemption) of the State CEQA Guidelines (Chapter 3 of Division 6 of Title 14 of the California Code of Regulations). The activity is covered by the Common Sense Exemption, which states that CEQA applies only to projects that have the potential for causing a significant effect on the environment. There is no possibility that the proposed change to the zoning code may have a significant effect on the environment; therefore, the activity is not subject to CEQA. No special circumstances exist that the proposed change would create a significant adverse effect on the environment (i.e. no sensitive species or habitats, no hazardous sites, no scenic highways, no historic resources, etc.). Public Notification: For the December 16, 2025, Planning Commission hearing, a legal ad was published on December 4, 2025, in the Easy Reader, a newspaper of general circulation, and posted in three locations. Attachments: 1. Draft Resolution #25-XX (redlined) 2. City Council Ordinance No. 25-1491 Respectfully Submitted by: Alexis Oropeza, Planning Manager Legal Review: Sarah Locklin, Interim Assistant City Attorney Approved: Alison Becker, Community Development Director Page 293 of 324 Page 1 of 9 RES NO. 25-XX CITY OF HERMOSA BEACH PC RESOLUTION NO. 25- xx A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA RECOMMENDING CITY COUNCIL APPROVE ZONE TEXT AMENDMENT 25-03 PERTAINING TO APPEAL PERIODS AND THE TRANSMISSION OF PLANNING COMMISSION DECISIONS TO CITY COUNCIL (CITYWIDE) AND DETERMINE THE PROJECT IS EXEMPT UNDER THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) PURSUANT TO SECTION 15061 (B)(3) OF THE CALIFORNIA PUBLIC RESOURCES CODE. THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: WHEREAS, on October 14, 2025, the City Council adopted Ordinance No. 25-1491, which amended Hermosa Beach Municipal Code Chapter 2.52 pertaining to City Council review of Planning Commission Decisions. Pursuant to Ordinance No. 25-1491, the City Council will conduct a review of Planning Commission actions if two councilmembers file a City Council review form with the City Clerk within 15 days of the action; and WHEREAS, Hermosa Beach Municipal Code Section 17.22.170 establishes the public appeal period for conditional use permits for residential condominium conversions; and WHEREAS, Hermosa Beach Municipal Code Section 17.38.330 establishes the public appeal period for Precise Development Plans in Specific Plan Area 8; and WHEREAS, Hermosa Beach Municipal Code Section 17.54.060 establishes the public appeal period for variances and references Chapter 2.52 of the Hermosa Beach Municipal Code; and WHEREAS, Hermosa Beach Municipal Code Section 17.56.100 establishes the public appeal period for Conditional Use Permits and references Chapter 2.52 of the Hermosa Beach Municipal Code; and WHEREAS, Hermosa Beach Municipal Code Section 17.64.020 establishes the Page 294 of 324 Page 2 of 9 RES NO. 25-XX public appeal period for development agreements; and WHEREAS, the Planning Commission held a duly noticed public hearing on December 16, 2025, to consider amending subsection 17.22.170, 17.38.330, 17.54.060, 17.56.100, and 17.64.010 of the Hermosa Beach Municipal Code (TA25-03) to establish public appeal periods consistent with the City Council review periods and procedures in Chapter 2.52 established by Ordinance No. 25-1491, as described in the draft ordinance attached as Exhibit A; and WHEREAS, the proposed zone text amendment is not a project subject to the California Environmental Quality Act (CEQA) pursuant to Sections 15060(c)(2) (the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c)(3) (the activity is not a project as defined in Section 15378) of the CEQA Guidelines (Chapter 3 to Title 14 of the California Code of Regulations) because it has no potential for resulting in physical change to the environment, directly or indirectly. Further, even if the amendment is a project, the project is covered by the Common Sense Exemption that CEQA applies only to projects which have the potential for causing a significant effect on the environment. There is no possibility that the proposed change to the zoning code may have a significant effect on the environment, therefore the activity is not subject to CEQA. This amendment is aimed at updating the appeal period and City Council’s review of Planning Commission actions, but it does not authorize any new physical development or alter the intensity of land use in the area and will not cause any physical changes to the environment. No special circumstances exist that the proposed change would create a significant adverse effect on the environment (i.e. no sensitive species or habitats, no hazardous sites, no scenic highways, no historic resources, etc.). NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. The Planning Commission of the City of Hermosa Beach hereby recommends that the City Council approve Zone Text Amendment 25-03, as included in Exhibit A. PASSED, APPROVED and ADOPTED on this 16th day of December 2025. VOTE: AYES: NOE: ABSTAIN: ABSENT: Page 295 of 324 Page 3 of 9 RES NO. 25-XX CERTIFICATION I hereby certify the foregoing PC Resolution 25-xx is a true and complete record of the action taken by the Planning Commission of the City of Hermosa Beach, California, at its regular meeting of December 16, 2025. Kate Hirsh Alison Becker Chair Secretary Date Page 296 of 324 Page 4 of 9 RES NO. 25-XX Exhibit A to Resolution PC 25-XX – Draft Ordinance Page 297 of 324 CITY OF HERMOSA BEACH ORDINANCE NO. 25- AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA, AMENDING HERMOSA BEACH MUNICIPAL CODE TITLE 17 PERTAINING TO APPEAL PERIODS AND THE TRANSMISSION OF PLANNING COMMISSION DECISIONS TO CITY COUNCIL (CITYWIDE); AND FINDING THE ACTION TO BE EXEMPT FROM CEQA RECITALS WHEREAS, on October 14, 2025, the City Council amended Hermosa Beach Municipal Code Chapter 2.52 pertaining to City Council review of Planning Commission Decisions. The City will conduct a review of Planning Commission actions if two councilmembers file a City Council review form with the City Clerk within 15 days of the decision; and WHEREAS, Hermosa Beach Municipal Code Section 17.22.170 establishes the public appeal period for conditional use permits for residential condominium conversions; and WHEREAS, Hermosa Beach Municipal Code Section 17.38.330 establishes the public appeal period for Precise Development Plans in Specific Plan Area 8; and WHEREAS, Hermosa Beach Municipal Code Section 17.54.060 establishes the public appeal period for variances and references Chapter 2.52 of the Hermosa Beach Municipal Code; and WHEREAS, Hermosa Beach Municipal Code Section 17.56.100 establishes the public appeal period for Conditional Use Permits and references Chapter 2.52 of the Hermosa Beach Municipal Code; and WHEREAS, Hermosa Beach Municipal Code Section 17.64.020 establishes the public appeal period for development agreements; and WHEREAS, the City Council desires to amend subsection 17.22.170, 17.38.330, 17.54.060, 17.56.100, and 17.64.010 of the Hermosa Beach Municipal Code to establish public appeal periods consistent with the City Council review periods and procedures in Chapter 2.52 established by Ordinance No. 25-1491; and Page 298 of 324 WHEREAS, the Planning Commission held a duly noticed public hearing on December 16, 2025, to consider amending subsection 17.22.170, 17.38.330, 17.54.060, 17.56.100, and 17.64.010 of the Hermosa Beach Municipal Code (TA25- 03) as described in the draft ordinance attached as Exhibit A. THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA DOES HEREBY ORDAIN AS FOLLOWS: SECTION 1. Recitals. The recitals above are true and correct, and are hereby incorporated herein by this reference. SECTION 2. Amendment. Subsection 17.22.170 of Chapter 17.22, “Condominiums, Stock Cooperatives and Community Apartments,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “17.22.170 Conversions to residential–conditional use permit required–public hearing–appeal. Condominium conversions, community apartments and stock cooperatives shall require a conditional use permit from the planning commission. Said permit if approved by the commission in a public hearing shall be subject to approval or denial by the city council. The actions of the planning commission in regard to a request for condominium conversion, community apartment or stock cooperative may be appealed in writing to the city council within fifteen (15)ten days of the formal action by the commission.” SECTION 3. Amendment. Subsection 17.54.060(B) of Chapter 17.54, “Variances,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “Variances. Appeals shall be in writing, including the specific areas of disagreement with the board of zoning adjustments’ Planning Commission’s decision. Fees for appeals will be established by resolution of the city council. Appeals shall be filed with the city clerk’s office in writing ten days from the date of the succeeding regular city council meeting at which it is determined whether or not to review the decision of the planning commission pursuant to Section 2.52.040 within fifteen (15) days of the planning commission’s issuance of a report of decision and findings. The filing of an appeal or a City Council Review initiated pursuant to Section 2.52.040 with the city clerk shall stay the planning commission’s decision on a variance. When an appeal is filed, the planning Page 299 of 324 commission shall transmit the record of the case to the city council. The city council shall conduct a public hearing in accordance with Chapter 17.68. Such hearing shall be held within forty (40) days of the council’s receipt of the written appeal. The city council shall announce its findings within sixty (60) days of the hearing, unless good cause is found for an extension. The council may incorporate by reference the findings of the board of zoning adjustment. The council’s action shall be final. Within thirty (30) days of its final decision on a variance, the city clerk shall mail notice to the applicant and appellant. A copy of this notice shall be included in the planning commission’s permanent files.” SECTION 4. Amendment. Subsection 17.56.100 of Chapter 17.56, “Conditional Use Permits,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “17.56.100 Effective date – Time limitation of appeal The orderdecision of the planning commission in granting or denying a conditional use permit shall become final and effective fifteen (15) ten days from the date of the succeeding city council meeting at which it is determined whether or not to review the decision of the from the planning commission decision unless the matter is called up for City Council review pursuant to Section 2.52.040 of this code until within such ten-day period or an appeal in writing is filed with the council by any person dissatisfied with the decision of the planning commission. The filing of such an appeal within such time shall stay the effective date of the order of the planning commission until such time as the council has acted on the appeal as hereinafter set forth in this title.” SECTION 5. Amendment. Subsection 17.64.020 of Chapter 17.64, “Development Agreements,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “17.64.020 Periodic review of development agreements Any approved development agreement shall be reviewed by the planning commission (whose decision may be appealed to the city council in writing within fifteen (15) ten days after the planning commission decision on review) at least every twelve (12) months after the approval of the agreement. The review shall be preceded by reasonable notice to the other party of the time of review and of any evidence that the agreement is not being complied with.” Page 300 of 324 SECTION 6. Severability. If any part of this ordinance or its application is deemed invalid by a court of competent jurisdiction, the City Council intends that such invalidity will not affect the effectiveness of the remaining provisions or applications and, to this end, the provisions of this Ordinance are severable. SECTION 7. California Environmental Quality Act (“CEQA”). The City Council finds that this not a project subject to the California Environmental Quality Act (CEQA) pursuant to Sections 15060(c)(2) (the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c)(3) (the activity is not a project as defined in Section 15378) of the CEQA Guidelines (Chapter 3 to Title 14 of the California Code of Regulations) because it has no potential for resulting in physical change to the environment, directly or indirectly. Further, even if the amendment is a project, the project is covered by the Common Sense Exemption that CEQA applies only to projects which have the potential for causing a significant effect on the environment. There is no possibility that the proposed change to the zoning code may have a significant effect on the environment, therefore the activity is not subject to CEQA. This amendment is aimed at updating the appeal period and City Council’s review, but it does not authorize any new physical development or alter the intensity of land use in the area and will not cause any physical changes to the environment. No special circumstances exist that the proposed change would create a significant adverse effect on the environment (i.e. no sensitive species or habitats, no hazardous sites, no scenic highways, no historic resources, etc.). SECTION 8. Effective Date. This Ordinance shall become effective and be in full force and effect from and after thirty (30) days of its final passage and adoption. SECTION 9. Certification. The City Clerk is directed to certify the passage and adoption of this Ordinance; cause it to be entered into the City’s book of original ordinances; make a note of the passage and adoption in the records of this meeting; and, within fifteen (15) days after the passage and adoption of this Ordinance, cause it to be published or posted in accordance with California law. PASSED, APPROVED and ADOPTED on this ___th day of _______, 2026. AYES: NOES: ABSTAIN: ABSENT: ______________________________________________________________________________ Page 301 of 324 Mayor Rob Saemann PRESIDENT of the City Council and MAYOR of the City of Hermosa Beach, CA ATTEST: APPROVED AS TO FORM: _________________________________ _________________________________ Myra Maravilla Jason Baltimore City Clerk Interim City Attorney Page 302 of 324 Page 303 of 324 Page 304 of 324 Page 305 of 324 Page 306 of 324 Page 307 of 324 City of Hermosa Beach | Page 1 of 3 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-175 Honorable Chair and Members of the Hermosa Beach Planning Commission LOCATION: CITYWIDE A ZONE TEXT AMENDMENT (TA 25-04) AMENDING HERMOSA BEACH MUNICIPAL CODE SECTION 17.08.020(D) PERTAINING TO HOME OCCUPATIONS CEQA: The project is exempt from the CEQA per section 15061(b)(3) of the California Environmental Quality Act Guidelines. (Community Development Director Alison Becker) Recommended Action: Staff recommends that the Planning Commission: 1. Find that the adoption of the proposed ordinance exempt from review under the California Environmental Quality Act (“CEQA”); and 2. Adopt a Resolution (Attachment 1) recommending that the City Council adopt the proposed ordinance approving Zone Text Amendment 25-04 amending Section 17.08.020(D) pertaining to Home Occupations (Citywide). Executive Summary: This item proposes amendments to the Hermosa Beach Municipal Code (HBMC) Section17.08.020(D) to simplify and expedite the business license process for home- based businesses. The amendments are intended to enhance customer service, reduce processing time, and improve consistency and transparency in the City’s business licensing practices. The proposed changes align with the City Council’s goals of supporting local economic vitality, improving efficiency in City operations, and fostering a business-friendly environment while maintaining compliance with applicable regulations. Background: The City currently regulates business licensing under Hermosa Beach Municipal Code Chapters 5.04 and Section 17.08.020. While the existing procedures provide necessary regulatory oversight, they were developed prior to the implementation of the City’s current digital permitting systems and do not fully reflect best practices for online, streamlined, and customer-centered processes. Staff conducted a review of the City’s business license processes in coordination with Administrative Services, Community Development, and the City Manager’s Office. The Page 308 of 324 City of Hermosa Beach | Page 2 of 3 review identified several opportunities to modernize and clarify existing requirements for both commercial business and home occupation licenses and were presented as an information item at its December 9, 2025, meeting. Discussion: To modernize and streamline the City’s business licensing process, the proposed amendments refine and clarify application requirements, ensuring consistency and transparency in documentation standards for both commercial and home-based businesses. Staff recommends the following amendments to HBMC Section 17.08.020(D) – Home Occupations: 1. Combine Subsections (1) and (2): Merge the current subsections (1) and (2) to streamline standards related to permitted floor area and storage of inventory or materials. This amendment would allow one room within a dwelling unit to be used for the home occupation, including the storage of related inventory and supplies. 2. Update Subsection (7): Replace the reference to “Planning Department” with “Community Development Department” to reflect the current department title. 3. Update Subsection (11): Updating the title from “Planning Director” to current title, “Community Development Director.” This change would ensure our code reflects the current organizational structure. 4. Delete Subsection (17): Remove subsection (17), which requires a physical inspection of the premises prior to permit approval. Inspections for home occupations are no longer necessary given the limited, low-impact nature of most home-based businesses. Removing this requirement would reduce staff workload and expedite permit issuance without compromising code compliance or public safety. Additionally, inspections of home offices are no longer common practice in neighboring jurisdictions. Next Steps: Tentatively, this Zone Text Amendment is scheduled for the City Council meeting in January of 2026. General Plan Consistency: PLAN Hermosa, the City’s General Plan, was adopted by the City Council in August 2017. The proposed Zone Text Amendments pertaining to home occupations supports several goals and policies within the Governance Element that are listed below. Goal 1. The community is active and engaged in decision-making processes. Policies:  2.9 Evaluation and feedback. Periodically solicit service evaluations from the community and utilize feedback to improve and develop the City’s policies, ordinances, programs, and funding priorities. Page 309 of 324 City of Hermosa Beach | Page 3 of 3 Goal 3. Excellent customer service through the use of emerging technologies. Policies:  3.1 Increased access to services. Strive to provide access to facilities, programs, and services at times and locations that are convenient for residents and businesses.  3.3 Online materials. As feasible, continue to expand the City’s website with data and materials for residents and people doing business with the City, including City Council and Commission agenda packets, permit application forms, web-based geographic information systems (GIS), and use of new technologies as appropriate. Goal 5. Small beach town character is reflected throughout Hermosa Beach. Policies:  5.1 Residential and commercial compatibility. Provide a balance between residential and commercial uses and strive to ensure their compatibility.  5.3 Clear regulations. Establish clear, unambiguous regulations and policies to clearly communicate the City’s expectations for new development. Environmental Determination: The proposed zone text amendment is a project subject to the California Environmental Quality Act (CEQA) and qualifies for an exemption from CEQA pursuant to Section 15061(b)(3) (Common Sense Exemption) of the State CEQA Guidelines (Chapter 3 of Division 6 of Title 14 of the California Code of Regulations). The activity is covered by the Common Sense Exemption that CEQA applies only to projects which have the potential to have a significant effect on the environment. There is no possibility that the proposed change to the zoning code may have a significant effect on the environment, therefore the activity is not subject to CEQA. No special circumstances exist that the proposed change would create a significant adverse effect on the environment (i.e. no sensitive species or habitats, no hazardous sites, no scenic highways, no historic resources, etc.). Public Notification: For the current agenda item, a notice was published in the Easy Reader on December 4, 2025, and notices posted at City Hall, the Library, and Community Resources Building. Attachments: 1. Draft Planning Commission Resolution 2. Draft Ordinance Amending HBMC 17.08.020 Respectfully Submitted by: Leo Zalyan, Management Analyst Concur: Alexis Oropeza, Planning Manager Legal Review: Sarah Lockin, Interim Assistant City Attorney Approved: Alison Becker, Community Development Director Page 310 of 324 Page 1 of 77 RES NO. 25-XX CITY OF HERMOSA BEACH PC RESOLUTION NO. 25-xx A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA RECOMMENDING CITY COUNCIL APPROVE ZONE TEXT AMENDMENT 25-xx PERTAINING TO HOME OCCUPATIONS (CITYWIDE) AND DETERMINE THE PROJECT IS EXEMPT UNDER THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) PURSUANT TO SECTION 15061 (B)(3) OF THE OF THE CALIFORNIA PUBLIC RESOURCES CODE. THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: WHEREAS, on December 9, 2025, the City Council directed staff to amend subsection 17.08.020(D) to update and streamline the requirements for home occupations in the R-1 Zone; and WHEREAS, Hermosa Beach Municipal Code Chapter 17.08, “R-1 Single-Family Residential Zone,” provides development standards for single-family dwellings in the City to assure adequate access to schools, parks, and facilities, prohibit negative impacts from nonresidential uses, protect the residential character of neighborhoods, and encourage a high quality environment for family life; and WHEREAS, Hermosa Beach Municipal Code Section 17.08.020 defines the permitted uses in the R-1 Zone, which includes home occupations pursuant to subsection 17.08.020(D); and WHEREAS, the Planning Commission held a duly noticed public hearing on December 16, 2025, to consider amending subsection 17.08.020 (D) of the Hermosa Beach Municipal Code (TA25-xx) as described in the draft ordinance attached as Exhibit A; and WHEREAS, the proposed zone text amendment is not a project subject to the California Environmental Quality Act (CEQA) pursuant to Sections 15060(c)(2) (the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c)(3) (the activity is not a project as defined in Section 15378) of the CEQA Guidelines (Chapter 3 to Title 14 of the California Code of Regulations) because it has no potential for resulting in physical change to the environment, directly or indirectly. Further, even if the amendment is a project, the project is covered by the Common Sense Exemption that CEQA applies only to projects which have the potential for causing a significant effect on the environment. There is no possibility that the proposed change to the zoning code may have a significant effect on the environment, therefore the activity is not subject to CEQA. This amendment is aimed at updating the permitted uses in the R-1 Zone to reflect current needs, but it does not authorize any new physical development or alter the intensity of land use in the area and will not cause any physical changes to Page 311 of 324 Page 2 of 77 RES NO. 25-XX the environment. No special circumstances exist that the proposed change would create a significant adverse effect on the environment (i.e. no sensitive species or habitats, no hazardous sites, no scenic highways, no historic resources, etc.). NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF HERMOSA BEACH, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1. The Planning Commission of the City of Hermosa Beach hereby recommends City Council approve Zone Text Amendment 25-xx, as included in Exhibit A. PASSED, APPROVED and ADOPTED on this 16th day of December 2025. VOTE: AYES: NOES: ABSTAIN: ABSENT: CERTIFICATION I hereby certify the foregoing PC Resolution 25-xx is a true and complete record of the action taken by the Planning Commission of the City of Hermosa Beach, California, at its regular meeting of December 16, 2025. Kate Hirsh Alison Becker Chair Secretary Date Page 312 of 324 Page 3 of 77 RES NO. 25-XX Exhibit A to Resolution PC 25-XX – Draft Ordinance Page 313 of 324 CITY OF HERMOSA BEACH ORDINANCE NO. 25- AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA, AMENDING SUBSECTION 17.08.020(D) OF THE HERMOSA BEACH MUNICIPAL CODE RELATING TO HOME OCCUPATIONS; AND FINDING THE ACTION TO BE EXEMPT FROM CEQA RECITALS WHEREAS, Hermosa Beach Municipal Code Chapter 17.08, “R-1 Single-Family Residential Zone,” provides development standards for single-family dwellings in the City to assure adequate access to schools, parks, and facilities, prohibit negative impacts from nonresidential uses, protect the residential character of neighborhoods, and encourage a high quality environment for family life; and WHEREAS, Hermosa Beach Municipal Code Section 17.08.020 defines the permitted uses in the R-1 Zone, which includes home occupations pursuant to subsection 17.08.020(D); and WHEREAS, the City desires to amend subsection 17.08.020(D) to update and streamline the requirements for home occupations in the R-1 Zone; and WHEREAS, the Hermosa Beach Planning Commission conducted a duly noticed public hearing on the proposed ordinance at its meeting on December 16, 2025, and considered all public comment and testimony. The Planning Commission adopted Resolution No. 25-XX recommending the adoption of the proposed ordinance. THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA DOES HEREBY ORDAIN AS FOLLOWS: SECTION 1. Recitals. The recitals above are true and correct, and are hereby incorporated herein by this reference. SECTION 2. Amendment. Subsection 17.08.020(D) of Chapter 17.08, “R-1 Single-Family Residential Zone,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “17.08.020 Permitted Uses. Subject to the restrictions hereinafter specified, only the following uses are permitted in an R-1 zone: … D. Home Occupations. When conducted in accordance with the following requirements, and when a permit therefor, containing any conditions deemed necessary to ensure compliance with the requirements of this chapter and with its purpose and intent, has been issued by the business license department; provided however, that any occupation may be excluded from certain or all zones, or portions thereof, if determined by the planning commission to be incompatible with neighboring residential uses. The following requirements are severally and jointly stated as absolute requirements, and any home occupation not conforming to the following requirements shall not be permitted: Page 314 of 324 1. Such occupation shall be carried on only by occupants of a dwelling, and shall be restricted to only one room in the dwelling, and all materials, equipment, or facilities shall be kept therein. involve the use of not more than four hundred (400) square feet, not to exceed twenty-five (25) percent of the total area of the permitted buildings on the premises. 2. Inventory and supplies for such home occupation shall occupy not more than twenty-five (25) percent of the permitted area and shall be stored entirely within an enclosure or building. 3. 2. No sale of goods is permitted on the premises. 4. 3. No employees are allowed. 5. 4. No signs are permitted. 6. 5. No display of any kind shall be visible from the exterior of the premises. 7. 6. Light, but not medium or heavy, business machines are allowed. The classification by the planning department shall be final. 8. 7. No presses, data processing equipment, or any electrical or other equipment requiring specialized electrical installation, or requiring over one hundred twenty (120) volts of power to operate are allowed, nor shall any mechanical shop or electrical tools be permitted except those which are customary to home crafts. 9. 8. No tools or equipment may be operated which make a sound audible from without the premises at a distance of twenty (20) feet from the property line, between the hours of 6:00 p.m. and 9:00 a.m. No activity or equipment which makes any loud or whining noise discernible from without the premises is permitted at any time. 10. 9. No garaging or storing of vehicles bearing any advertising related to the home occupation is allowed upon the premises or in the street in the vicinity. 11. 10. No foot or vehicle traffic may be generated to or from the premises except for traditional uses such as tutors and day care centers as approved by the Community Development Director. planning director. 12. 11. There shall be complete conformity to fire, building, plumbing, electrical, zoning and health codes and to all state and city laws and ordinances; except, where required parking spaces are not available, the planning commission may temporarily waive such requirements if they find: a. The garage, carport or space is not available solely because of temporary storage, and not because of construction and/or building improvement or modifications; and Page 315 of 324 b. The temporary storage is not related to products, materials, etc., used for the conduct of the home occupation; and c. Such waiver to be effective only if no detrimental effects are caused to adjacent properties and no valid complaints were filed due to storage. 13. 12. No structural alterations of the premises are permitted solely for the benefit of the business. 14. 13. No listing or advertising of the address of such home occupation for business purposes is permitted including display ads in telephone, business and city directories and in newspapers and magazines. The telephone number and address may be listed on business cards. 15. 14. The term of any permit shall be for one (1) year, or for such other period as shall be authorized by the city council. 16. 15. It shall be a condition of any permit hereunder that the applicant shall agree that, in the event of amendment of this section to prohibit such or any home occupation in a zone in which the same is situated, that such home occupation shall not have the status of nonconforming use, and may be eliminated forthwith without provision for extended liquidation or amortization. 17. Prior to permit approval, the premises shall be inspected to determine compliance with all limitations and requirements, particularly subsection (D)(12) of this section. …” SECTION 3. Severability. If any part of this ordinance or its application is deemed invalid by a court of competent jurisdiction, the City Council intends that such invalidity will not affect the effectiveness of the remaining provisions or applications and, to this end, the provisions of this Ordinance are severable. SECTION 4. California Environmental Quality Act (“CEQA”). The City Council finds that this Ordinance is not subject to CEQA pursuant to Sections 15060(c)(2) (the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c)(3) (the activity is not a project as defined in Section 15378) of the CEQA Guidelines (Chapter 3 to Title 14 of the California Code of Regulations) because it has no potential for resulting in physical change to the environment, directly or indirectly. SECTION 5. Effective Date. This Ordinance shall become effective and be in full force and effect from and after thirty (30) days of its final passage and adoption. SECTION 6. Certification. The City Clerk is directed to certify the passage and adoption of this Ordinance; cause it to be entered into the City’s book of original ordinances; make a note of the passage and adoption in the records of this meeting; and, within fifteen (15) days after the passage and adoption of this Ordinance, cause it to be published or posted in accordance with California law. Page 316 of 324 PASSED, APPROVED and ADOPTED on this ___th day of _______, 2026. AYES: NOES: ABSTAIN: ABSENT: ______________________________________________________________________________ Mayor Rob Saemann PRESIDENT of the City Council and MAYOR of the City of Hermosa Beach, CA ATTEST: APPROVED AS TO FORM: _________________________________ _________________________________ Myra Maravilla Jason Baltimore City Clerk Interim City Attorney Page 317 of 324 CITY OF HERMOSA BEACH ORDINANCE NO. 25- AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA, AMENDING SUBSECTION 17.08.020(D) OF THE HERMOSA BEACH MUNICIPAL CODE RELATING TO HOME OCCUPATIONS; AND FINDING THE ACTION TO BE EXEMPT FROM CEQA RECITALS WHEREAS, Hermosa Beach Municipal Code Chapter 17.08, “R-1 Single-Family Residential Zone,” provides development standards for single-family dwellings in the City to assure adequate access to schools, parks, and facilities, prohibit negative impacts from nonresidential uses, protect the residential character of neighborhoods, and encourage a high quality environment for family life; and WHEREAS, Hermosa Beach Municipal Code Section 17.08.020 defines the permitted uses in the R-1 Zone, which includes home occupations pursuant to subsection 17.08.020(D); and WHEREAS, the City desires to amend subsection 17.08.020(D) to update and streamline the requirements for home occupations in the R-1 Zone; and WHEREAS, the Hermosa Beach Planning Commission conducted a duly noticed public hearing on the proposed ordinance at its meeting on December 16, 2025, and considered all public comment and testimony. The Planning Commission adopted Resolution No. 25-XX recommending the adoption of the proposed ordinance. THE CITY COUNCIL OF THE CITY OF HERMOSA BEACH, CALIFORNIA DOES HEREBY ORDAIN AS FOLLOWS: SECTION 1. Recitals. The recitals above are true and correct, and are hereby incorporated herein by this reference. SECTION 2. Amendment. Subsection 17.08.020(D) of Chapter 17.08, “R-1 Single- Family Residential Zone,” of Title 17, “Zoning,” of the Hermosa Beach Municipal Code is hereby amended to read in its entirety as follows, with deletions shown in strikethrough and additions shown in bold italics: “17.08.020 Permitted Uses. Subject to the restrictions hereinafter specified, only the following uses are permitted in an R-1 zone: … D. Home Occupations. When conducted in accordance with the following requirements, and when a permit therefor, containing any conditions deemed necessary to ensure compliance with the Page 318 of 324 requirements of this chapter and with its purpose and intent, has been issued by the business license department; provided however, that any occupation may be excluded from certain or all zones, or portions thereof, if determined by the planning commission to be incompatible with neighboring residential uses. The following requirements are severally and jointly stated as absolute requirements, and any home occupation not conforming to the following requirements shall not be permitted: 1. Such occupation shall be carried on only by occupants of a dwelling, and shall be restricted to only one room in the dwelling, and all materials, equipment, or facilities shall be kept therein. involve the use of not more than four hundred (400) square feet, not to exceed twenty-five (25) percent of the total area of the permitted buildings on the premises. 2. Inventory and supplies for such home occupation shall occupy not more than twenty-five (25) percent of the permitted area and shall be stored entirely within an enclosure or building. 3. 2. No sale of goods is permitted on the premises. 4. 3. No employees are allowed. 5. 4. No signs are permitted. 6. 5. No display of any kind shall be visible from the exterior of the premises. 7. 6. Light, but not medium or heavy, business machines are allowed. The classification by the planning department Community Development Department shall be final. 8. 7. No presses, data processing equipment, or any electrical or other equipment requiring specialized electrical installation, or requiring over one hundred twenty (120) volts of power to operate are allowed, nor shall any mechanical shop or electrical tools be permitted except those which are customary to home crafts. 9. 8. No tools or equipment may be operated which make a sound audible from without the premises at a distance of twenty (20) feet from the property line, between the hours of 6:00 p.m. and 9:00 a.m. No activity or equipment which makes any loud or whining noise discernible from without the premises is permitted at any time. 10. 9. No garaging or storing of vehicles bearing any advertising related to the home occupation is allowed upon the premises or in the street in the vicinity. Page 319 of 324 11. 10. No foot or vehicle traffic may be generated to or from the premises except for traditional uses such as tutors and day care centers as approved by the Community Development Director. planning director. 12. 11. There shall be complete conformity to fire, building, plumbing, electrical, zoning and health codes and to all state and city laws and ordinances; except, where required parking spaces are not available, the planning commission may temporarily waive such requirements if they find: a. The garage, carport or space is not available solely because of temporary storage, and not because of construction and/or building improvement or modifications; and b. The temporary storage is not related to products, materials, etc., used for the conduct of the home occupation; and c. Such waiver to be effective only if no detrimental effects are caused to adjacent properties and no valid complaints were filed due to storage. 13. 12. No structural alterations of the premises are permitted solely for the benefit of the business. 14. 13. No listing or advertising of the address of such home occupation for business purposes is permitted including display ads in telephone, business and city directories and in newspapers and magazines. The telephone number and address may be listed on business cards. 15. 14. The term of any permit shall be for one (1) year, or for such other period as shall be authorized by the city council. 16. 15. It shall be a condition of any permit hereunder that the applicant shall agree that, in the event of amendment of this section to prohibit such or any home occupation in a zone in which the same is situated, that such home occupation shall not have the status of nonconforming use, and may be eliminated forthwith without provision for extended liquidation or amortization. 17. Prior to permit approval, the premises shall be inspected to determine compliance with all limitations and requirements, particularly subsection (D)(12) of this section. …” SECTION 3. Severability. If any part of this ordinance or its application is deemed invalid by a court of competent jurisdiction, the City Council intends that such invalidity will not affect the effectiveness of the remaining provisions or applications and, to this end, the provisions of this Ordinance are severable. SECTION 4. California Environmental Quality Act (“CEQA”). The City Council finds that this Ordinance is not subject to CEQA pursuant to Sections 15060(c)(2) (the activity will not Page 320 of 324 result in a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c)(3) (the activity is not a project as defined in Section 15378) of the CEQA Guidelines (Chapter 3 to Title 14 of the California Code of Regulations) because it has no potential for resulting in physical change to the environment, directly or indirectly. SECTION 5. Effective Date. This Ordinance shall become effective and be in full force and effect from and after thirty (30) days of its final passage and adoption. SECTION 6. Certification. The City Clerk is directed to certify the passage and adoption of this Ordinance; cause it to be entered into the City’s book of original ordinances; make a note of the passage and adoption in the records of this meeting; and, within fifteen (15) days after the passage and adoption of this Ordinance, cause it to be published or posted in accordance with California law. PASSED, APPROVED and ADOPTED on this ___th day of _______, 2026. AYES: NOES: ABSTAIN: ABSENT: ______________________________________________________________________________ Mayor Rob Saemann PRESIDENT of the City Council and MAYOR of the City of Hermosa Beach, CA ATTEST: APPROVED AS TO FORM: _________________________________ _________________________________ Myra Maravilla Jason Baltimore City Clerk Interim City Attorney Page 321 of 324 Revision: 12/2/2025 F:\B95\CD\PC\2025\Planning Commission 2026 Meeting Schedule.docx Planning Commission 2026 Meeting Schedule Planning Commission meetings are on the third Tuesday of the month at 5:00pm. • Tuesday, January 20, 2026 • Tuesday, February 17, 2026 • Tuesday, March 17, 2026 • Tuesday, April 21, 2026 • Tuesday, May 19, 2026 • Tuesday, June 16, 2026 • Tuesday, July 21, 2026 • Tuesday, August 18, 2026 • Tuesday, September 15, 2026 • Tuesday, October 20, 2026 • Tuesday, November 17, 2026 • Tuesday, December 15, 2026 CITY OF HERMOSA BEACH COMMUNITY DEVELOPMENT DEPARTMENT | PLANNING DIVISION 1315 VALLEY DRIVE | HERMOSA BEACH | CA 90254 FOR QUESTIONS PLEASE CONTACT PLANNING@HERMOSABEACH.GOV OR CALL (310) 318-0242 OFFICE HOURS: MONDAY TO THURSDAY, 7:00 AM TO 6:00 PM Page 322 of 324 City of Hermosa Beach | Page 1 of 1 Meeting Date: December 16, 2025 Staff Report No. 25-CDD-179 Honorable Chair and Members of the Hermosa Beach Planning Commission PLANNING COMMISSION TENTATIVE FUTURE AGENDA (Planning Manager Alexis Oropeza) Recommended Action: Staff recommend Planning Commission receive and file the tentative future agenda for the Planning Commission regular meeting of January 20, 2026. Attachment: 1. Planning Commission Tentative Agenda for January 2026 Respectfully Submitted by: Alexis Oropeza, Planning Manager Approved: Alison Becker, Community Development Director Page 323 of 324 C:\Program Files\eSCRIBE\TEMP\18553698128\18553698128,,,Attachment 1. Planning Commission Tentative Agenda January.docx Tentative Future Agendas PLANNING COMMISSION City of Hermosa Beach Tuesday, January 20, 2026 Regular Meeting Project Title Public Notice Meeting Date Zone Text Amendment – Hermosa Beach Municipal Code Title 17 pertaining to Accessory Dwelling Units (ADUs) and Junior ADUs. (Public Hearing) 12/23/25 1/20/26 Upcoming and Pending Zoning Code More Study Sessions upcoming 3201 Pacific Coast Highway – Precise Development Plan and Parking Plan for new commercial building (Skechers) Page 324 of 324